Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Ci. Rural ; 40(12)2010.
Artigo em Português | VETINDEX | ID: vti-706872

RESUMO

The study aimed to identify the effects of time, temperature of storage and excess of anticoagulant on hematological parameters of dogs. Blood samples of ten, clinically healthy dogs, of different breeds were utilized. Aliquots were stored with 1.8mg, 3.6mg, 7.2mg and 14.4mg of ethylenediaminetetraacetic acid (EDTA) per mL of blood, divided into two groups: 2°C to 8°C and room temperature. Right after collection, they were evaluated in four times: 0h, 12h, 24h and 48h. White blood cells, red blood cells, hemoglobin, packed cell volume (PCV), mean corpuscular volume (MCV), red cell distribution width (RDW), platelet and thrombocrit (PCT) were evaluated in the automatic cell counter. In the automatic cell counter analysis, the MCV increased significantly with higher concentrations of EDTA (7.2mg mL-1 and 14.4mg mL-1) peaking at 2.36%, in the highest concentration. Temperature and time also influenced the MCV, which showed a decrease in time 12 under temperature of 2°C to 8°C and an increase in time 24 and 48 at room temperature. Storage temperature influenced leukocytes and erythrocytes counts, which showed lower values at room temperature. Hemoglobin, PCV, platelet and PCT did not change significantly. The changes observed did not compromise the results obtained by automatic cell counter, showing that blood samples stored for two days remained in good condition for processing, especially when stored under refrigeration.


O estudo teve como objetivo identificar os efeitos do tempo de estocagem, da temperatura de armazenamento e da quantidade de anticoagulante sobre parâmetros hematológicos de cães. Foram utilizadas amostras do sangue de dez cães de raças variadas, clinicamente hígidos. As alíquotas foram colhidas com 1,8mg; 3,6mg; 7,2mg e 14,4mg de ácido etilenodiaminotetracético (EDTA) por mL de sangue, distribuídas em dois grupos: de 2°C a 8°C e temperatura ambiente. Após a coleta, foram avaliadas em quatro tempos: 0, 12, 24 e 48 horas. Usando um contador automático de células, foram avaliados leucócitos, eritrócitos, hemoglobina, hematócrito, volume corpuscular médio (VCM), índice de anisocitose eritrocitária (RDW), plaquetas e plaquetócrito (PCT). O valor do VCM diminuiu nas maiores concentrações de EDTA (7,2mg mL-1 e 14,4mg mL-1), com decréscimo de 2,36% na maior concentração. A temperatura e o tempo de armazenagem também ocasionaram alteração nesse parâmetro, ou seja, houve decréscimo no tempo 12 horas à temperatura de 2 a 8°C e aumento nos tempos 24 e 48 horas à temperatura ambiente (P 0,05). A temperatura de conservação influenciou discretamente a contagem de leucócitos e eritrócitos, que apresentaram valores menores na temperatura ambiente. Hemoglobina, hematócrito, plaquetas e PCT não apresentaram alteração significativa. As alterações observadas não comprometeram os resultados obtidos no contador automático, mostrando que as amostras sanguíneas, conservadas por 48 horas, mantiveram-se em boas condições para análise, principalmente quando armazenadas à temperatura de 2 a 8°C.

2.
Artigo em Português | LILACS-Express | VETINDEX | ID: biblio-1478004

RESUMO

The study aimed to identify the effects of time, temperature of storage and excess of anticoagulant on hematological parameters of dogs. Blood samples of ten, clinically healthy dogs, of different breeds were utilized. Aliquots were stored with 1.8mg, 3.6mg, 7.2mg and 14.4mg of ethylenediaminetetraacetic acid (EDTA) per mL of blood, divided into two groups: 2°C to 8°C and room temperature. Right after collection, they were evaluated in four times: 0h, 12h, 24h and 48h. White blood cells, red blood cells, hemoglobin, packed cell volume (PCV), mean corpuscular volume (MCV), red cell distribution width (RDW), platelet and thrombocrit (PCT) were evaluated in the automatic cell counter. In the automatic cell counter analysis, the MCV increased significantly with higher concentrations of EDTA (7.2mg mL-1 and 14.4mg mL-1) peaking at 2.36%, in the highest concentration. Temperature and time also influenced the MCV, which showed a decrease in time 12 under temperature of 2°C to 8°C and an increase in time 24 and 48 at room temperature. Storage temperature influenced leukocytes and erythrocytes counts, which showed lower values at room temperature. Hemoglobin, PCV, platelet and PCT did not change significantly. The changes observed did not compromise the results obtained by automatic cell counter, showing that blood samples stored for two days remained in good condition for processing, especially when stored under refrigeration.


O estudo teve como objetivo identificar os efeitos do tempo de estocagem, da temperatura de armazenamento e da quantidade de anticoagulante sobre parâmetros hematológicos de cães. Foram utilizadas amostras do sangue de dez cães de raças variadas, clinicamente hígidos. As alíquotas foram colhidas com 1,8mg; 3,6mg; 7,2mg e 14,4mg de ácido etilenodiaminotetracético (EDTA) por mL de sangue, distribuídas em dois grupos: de 2°C a 8°C e temperatura ambiente. Após a coleta, foram avaliadas em quatro tempos: 0, 12, 24 e 48 horas. Usando um contador automático de células, foram avaliados leucócitos, eritrócitos, hemoglobina, hematócrito, volume corpuscular médio (VCM), índice de anisocitose eritrocitária (RDW), plaquetas e plaquetócrito (PCT). O valor do VCM diminuiu nas maiores concentrações de EDTA (7,2mg mL-1 e 14,4mg mL-1), com decréscimo de 2,36% na maior concentração. A temperatura e o tempo de armazenagem também ocasionaram alteração nesse parâmetro, ou seja, houve decréscimo no tempo 12 horas à temperatura de 2 a 8°C e aumento nos tempos 24 e 48 horas à temperatura ambiente (P 0,05). A temperatura de conservação influenciou discretamente a contagem de leucócitos e eritrócitos, que apresentaram valores menores na temperatura ambiente. Hemoglobina, hematócrito, plaquetas e PCT não apresentaram alteração significativa. As alterações observadas não comprometeram os resultados obtidos no contador automático, mostrando que as amostras sanguíneas, conservadas por 48 horas, mantiveram-se em boas condições para análise, principalmente quando armazenadas à temperatura de 2 a 8°C.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA