Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Acta Chim Slov ; 69(1): 49-59, 2022 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-35298022

RESUMO

An HPLC-UV/FLD method for simultaneous detection of ten antibiotics in surface waters was developed. Antibiotics were extracted from water using solid phase extraction. An Atlantis T3 column was used with acetonitrile and 0.05% trifluoroacetic acid as a mobile phase for separation, with a total running time of 45 min. Signal detection was performed at 280 nm; fluoroquinolones were additionally quantified by fluorescence detection. Validation parameters such as linearity, recovery and precision were evaluated. The limits of detection (LOD) in river waters were in the range 0.1-1.3 µg/L for antibiotics detected by UV, and 0.039 and 0.073 µg/Lfor fluoroquinolones detected by FLD. LOD are sufficiently low to consider this method as a first alternative for HPLC-MS methods that will allow alerting for the presence of antibiotics in surface waters. This screening method is rapid, sensitive, reproducible and economical.


Assuntos
Antibacterianos , Poluentes Químicos da Água , Cromatografia Líquida de Alta Pressão/métodos , Espectrometria de Massas , Extração em Fase Sólida/métodos
2.
J Chromatogr Sci ; 52(10): 1281-7, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24596421

RESUMO

A chromatographic method was implemented and validated for the simultaneous determination of antimicrobials proposed for the treatment of mycetoma: three fluoroquinolones: ciprofloxacin, moxifloxacin and sparfloxacin; two oxazolidinones: DA-7157 (DA2; torezolid) and its prodrug DA-7218 (DA1). Separation of analytes was achieved on an Atlantis dC18 column (150 × 4.6 mm i.d., 5 µm particle size) with a mobile phase composed of acetonitrile and trifluoroacetic acid 0.1% (v/v) using a gradient program. Total running time was 30 min. Quantification of sparfloxacin was carried out using a DAD at 278 nm; the oxazolidinones DA1 and DA2 and the quinolones ciprofloxacin and moxifloxacin were analyzed by fluorescence with an excitation wavelength of 292 nm and an emission wavelength of 525 nm. Intraday precision was in the range of 3.2 and 14.1%. Linearity range was from 0.3 to 10 µg/mL for sparfloxacin using DAD detector, and from 0.2 to 10 µg/mL for ciprofloxacin, 0.3 to 10 µg/mL for DA2, 0.4 to 10 µg/mL for DA1 and 0.04 to 10 µg/mL for moxifloxacin with fluorescence detector. Acetonitrile was used to precipitate proteins from plasma. Recoveries at low, medium and high concentration were between 80 and 120%. Limits of quantification were between 0.04 and 0.4 µg/mL in plasma. The method can be applied for individual or simultaneous determination of the antimicrobials in plasma.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Fluoroquinolonas/sangue , Oxazolidinonas/sangue , Animais , Estabilidade de Medicamentos , Limite de Detecção , Modelos Lineares , Camundongos , Camundongos Endogâmicos BALB C , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...