Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Life Sci ; 206: 29-34, 2018 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-29778807

RESUMO

Noninvasive imaging using positron emission tomography/computed tomography (PET/CT) and single photon emission computed tomography/computed tomography (SPECT/CT) are considered revolutionized approaches to detect bone cancer. Both PET/CT and SPECT/CT technologies have advanced to permit miniaturization, which has provided the advantage of including animals as their own controls in longitudinal studies. The present study was designed to evaluate the potential of PET/CT and SPECT/CT as research tools to detect bone cancer in rats. We used a rat model of bone cancer induced by injecting Walker 256 tumor cells into the femoral cavity. Computed tomography demonstrated that rats presented a solid tumor at 15 days post injection (dpi). However, CT was not an effective method for identifying tumors at an earlier time point (8 dpi), when mechanical hyperalgesia (the most common symptom during bone cancer progression) had already initiated. At this early stage, PET/CT and SPECT/CT analysis detected higher uptake in the injected femur of the tracers 18F-Fluoride and 99mTc-Methyl diphosphonate (99mTc-MDP), respectively. These findings demonstrated for the first time that both 18F-Fluoride PET/CT and 99mTc-MDP SPECT/CT can detect cancer at early stages in rats and advocates for the PET/SPECT/CT as research tools to evaluate bone cancer in further longitudinal studies involving small animals.


Assuntos
Neoplasias Ósseas/diagnóstico por imagem , Osteossarcoma/diagnóstico por imagem , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Tomografia Computadorizada por Raios X/métodos , Animais , Carcinoma 256 de Walker/diagnóstico por imagem , Diagnóstico Precoce , Fêmur/diagnóstico por imagem , Radioisótopos de Flúor , Hiperalgesia/tratamento farmacológico , Processamento de Imagem Assistida por Computador , Masculino , Compostos Radiofarmacêuticos , Ratos , Ratos Wistar , Medronato de Tecnécio Tc 99m
2.
Life Sci, v. 206, p. 29-34, ago. 2018
Artigo em Inglês | Sec. Est. Saúde SP, SESSP-IBPROD, Sec. Est. Saúde SP | ID: bud-2475

RESUMO

Noninvasive imaging using positron emission tomography/computed tomography (PET/CT) and single photon emission computed tomography/computed tomography (SPECT/CT) are considered revolutionized approaches to detect bone cancer. Both PET/CT and SPECT/CT technologies have advanced to permit miniaturization, which has provided the advantage of including animals as their own controls in longitudinal studies. The present study was designed to evaluate the potential of PET/CT and SPECT/CT as research tools to detect bone cancer in rats. We used a rat model of bone cancer induced by injecting Walker 256 tumor cells into the femoral cavity. Computed tomography demonstrated that rats presented a solid tumor at 15 days post injection (dpi). However, CT was not an effective method for identifying tumors at an earlier time point (8 dpi), when mechanical hyperalgesia (the most common symptom during bone cancer progression) had already initiated. At this early stage, PET/CT and SPECT/CT analysis detected higher uptake in the injected femur of the tracers F-18-Fluoride and Tc-99m-Methyl diphosphonate (Tc-99m-MDP), respectively. These findings demonstrated for the first time that both F-18-Fluoride PET/CT and Tc-99m-MDP SPECT/CT can detect cancer at early stages in rats and advocates for the PET/SPECT/CT as research tools to evaluate bone cancer in further longitudinal studies involving small animals.

3.
Life Sci. ; 206: p. 29-34, 2018.
Artigo em Inglês | Sec. Est. Saúde SP, SESSP-IBPROD, Sec. Est. Saúde SP | ID: but-ib15135

RESUMO

Noninvasive imaging using positron emission tomography/computed tomography (PET/CT) and single photon emission computed tomography/computed tomography (SPECT/CT) are considered revolutionized approaches to detect bone cancer. Both PET/CT and SPECT/CT technologies have advanced to permit miniaturization, which has provided the advantage of including animals as their own controls in longitudinal studies. The present study was designed to evaluate the potential of PET/CT and SPECT/CT as research tools to detect bone cancer in rats. We used a rat model of bone cancer induced by injecting Walker 256 tumor cells into the femoral cavity. Computed tomography demonstrated that rats presented a solid tumor at 15 days post injection (dpi). However, CT was not an effective method for identifying tumors at an earlier time point (8 dpi), when mechanical hyperalgesia (the most common symptom during bone cancer progression) had already initiated. At this early stage, PET/CT and SPECT/CT analysis detected higher uptake in the injected femur of the tracers F-18-Fluoride and Tc-99m-Methyl diphosphonate (Tc-99m-MDP), respectively. These findings demonstrated for the first time that both F-18-Fluoride PET/CT and Tc-99m-MDP SPECT/CT can detect cancer at early stages in rats and advocates for the PET/SPECT/CT as research tools to evaluate bone cancer in further longitudinal studies involving small animals.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...