Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Simul Healthc ; 17(5): 351-352, 2022 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-35260543

RESUMO

SUMMARY STATEMENT: The global pandemic of COVID-19 had strong repercussions in healthcare simulation-based education around the world. Different adaptations to imposed restraints such as social distancing have been developed to address the educational needs of healthcare professionals. However, the lack of access to simulators in low-income countries or rural areas may restrict the access to distance simulation-based training.


Assuntos
COVID-19 , Pessoal de Saúde , Humanos , Pandemias
2.
Data Brief ; 37: 107258, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34277905

RESUMO

Aneurysm clipping requires the proficiency of several skills, yet the traditional way of practicing them has been recently challenged. The use of simulators could be an alternative educational tool. The aim of this data analysis is to provide further evaluation of a reusable low-cost 3D printed training model we developed for aneurysm clipping [1]. The simulator was designed to replicate the bone structure, arteries and targeted aneurysms. Thirty-two neurosurgery residents performed a craniotomy and aneurysm clipping using the model and then filled out a survey. The survey was designed in two parts: a 5-point Likert scale questionnaire and three questions requiring written responses [1]. Two dimensions of the model were evaluated by the questionnaire: the face validity, assessed by 5 questions about the realism of the model, and the content validity, assessed by 6 questions regarding the usefulness of the model during the different steps of the training procedure. The three questions requiring written responses referred to the strengths and weaknesses of the simulator and a global yes/no question as to whether or not they would repeat the experience. Demographic data, experience level and survey responses of the residents were grouped in a dataset [2]. A descriptive analysis was performed for each dimension. Then, the groups were compared according to their level of expertise (Junior and Senior groups) with an independent sample t-test. A Confirmatory Factor Analysis (CFA) was estimated, using a Weighted Least Squares Mean Variance adjusted (WLSMV) which works best for the ordinal data [3]. Fitness was calculated using chi-square (χ2) test, Comparative Fit Index (CFI), Tucker-Lewis Index (TLI), and the Root Mean Square Error of Approximation (RMSEA). A non-significant χ2, CFI and TLI greater than 0.90 and RMSEA < 0.08 were considered an acceptable fit [4]. All data analysis was performed using IBM SPSS 23.0 statistical software. Data are reported as mean + standard deviation (SD). A probability p < 0.05 was considered significant. Exploratory Factor Analysis was done to explore the factorial structure of the 11-items scale in the sample, first we performed a principal components analysis. The Kaiser-Meyer-Olkin measure verified the sampling adequacy for the analysis (KMO = 0.784; Bartlett's Test of Sphericity χ2 (55) = 243.44, p < .001), indicating correlation is adequate for factor analysis. Considering Eigen values greater than 1, a two-factor solution explained 73.1% of the variance but left one item in factor 2 (Q 11). The results of this factor analysis are presented in Table 1. Confirmatory Factor Analysis, considering only the 10 items in the first factor (removing question 11 of our model), was performed. This model reached the following fit: χ2 (35) = 38.821, p > .05; CFI = 0.997; TLI = 0.996; RMSEA 0.058, without any error terms to exhibit covariance. Regarding the reliability of the questionnaire, the internal consistency was explored in the 10 items selected in the confirmatory factor analysis with an alpha coefficient (α = 0.941).

3.
Rev. cir. (Impr.) ; 73(3): 280-286, jun. 2021. ilus
Artigo em Espanhol | LILACS | ID: biblio-1388837

RESUMO

Resumen Objetivo: Presentar la elaboración de un simulador de trauma torácico de alta fidelidad elaborado mediante modelamiento e impresión 3D a partir de un torso humano cadavérico. Materiales y Método: Estudio descriptivo del desarrollo de un simulador de trauma torácico utilizando metodología centrada en el prototipado y la iteración basada en testeos. Resultados: Se elaboró un simulador reutilizable mediante la digitalización de un torso cadavérico utilizando tomografía computada. Se realizó una reconstrucción digital del torso diseñando los planos subcutáneos, muscular y óseo en base a las imágenes del paciente pre y postoracotomía anterolateral. Utilizando impresión 3D y materiales sintéticos, se elaboró la caja torácica para luego instalar un corazón y pulmón porcino ventilado y perfundido. Los parches de la toracotomía son reemplazables y de bajo costo. En conjunto, este simulador permite el entrenamiento en manejo de lesiones traumáticas cardiacas y pulmonares de alta fidelidad. Conclusión: La metodología presentada permite la creación de un modelo para el entrenamiento y evaluación de habilidades quirúrgicas en trauma torácico. Los elementos principales del simulador son reutilizables y permiten mantener bajos los costos del entrenamiento.


Aim: To describe the design and creation of a high-fidelity thoracic trauma surgery simulation model incorporating 3D printing technology using a cadaveric human torso as a model. Materials and Method: This is a descriptive study that aims to illustrate the creation process of a thoracic trauma surgery simulation model throughout the incorporation of prototypes and dynamic iteration technologies. Results: A high-fidelity reusable thoracic trauma surgery simulation model was created from the digitalization of a cadaveric torso using a computed tomography scan. Throughout digital reconstruction tools, the subcutaneous, muscular, and skeletal structures were modeled from images obtained before and after an anterolateral thoracotomy. Using 3D printing and synthetic materials, a high-fidelity thoracic cavity was built so that perfused and ventilated porcine heart and lungs could be placed. A thoracotomy patch for the anterolateral thoracotomy was designed in a reusable and low-cost fashion. This simulation model is suitable for high fidelity training in the surgical management of cardiopulmonary traumatic injuries. Conclusion: The described methodology allowed the creation of a simulation model for training and assessment of surgical skills in thoracic trauma. The main components of the simulation model are made from reusable materials, broadening access to low-cost, high fidelity training.


Assuntos
Humanos , Traumatismos Torácicos , Impressão Tridimensional , Treinamento por Simulação/métodos , Educação Médica/métodos , Cirurgiões/educação , Treinamento por Simulação/tendências
4.
World Neurosurg ; 147: 29-36, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33276179

RESUMO

BACKGROUND: Aneurysm clipping requires the proficiency of several skills, yet the traditional way of practicing them has been recently challenged, especially by the growth of endovascular techniques. The use of simulators could be an alternative educational tool, but some of them are cumbersome, expensive to implement, or lacking in realism. The aim of this study is to evaluate a reusable low-cost 3-dimensional printed training model we developed for aneurysm clipping. METHODS: The simulator was designed to replicate the bone structure, arteries, and targeted aneurysms. Thirty-two neurosurgery residents performed a craniotomy and aneurysm clipping using the model and then filled out a survey. They were divided into Junior and Senior groups. Descriptive, exploratory, and confirmatory factor analysis was performed using IBM SPSS statistical software. RESULTS: The overall residents' response was positive, with high scores to face validity and content validity questions. There was no significant statistical difference between the Junior and Senior groups. The confirmatory factor and internal consistency analysis confirmed that the evaluation was highly reliable. Globally, 97% of the residents found the model was useful and would repeat the simulator experience. The financial cost is $2500 USD for implementation and only $180 USD if further training sessions are required. CONCLUSIONS: The main strengths of our training model are its highlighted realism, adaptability to trainees of different levels of expertise, sustainability, and low cost. Our data support the concept that it can be incorporated as a new training opportunity during professional specialty meetings and/or within residency academic programs.


Assuntos
Aneurisma Intracraniano/cirurgia , Neurocirurgia/educação , Procedimentos Neurocirúrgicos/educação , Impressão Tridimensional , Treinamento por Simulação/métodos , Adulto , Análise Fatorial , Feminino , Humanos , Internato e Residência , Masculino , Treinamento por Simulação/economia
5.
Int. j. morphol ; 38(3): 578-584, June 2020. tab, graf
Artigo em Espanhol | LILACS | ID: biblio-1098290

RESUMO

Los cursos de anatomía constituyen un componente esencial del currículo de medicina, aportando las bases morfológicas para el examen clínico, la interpretación de imágenes médicas y la práctica segura de intervenciones quirúrgicas y procedimientos. Recientemente, la tecnología de impresión 3D ha permitido generar réplicas de disecciones de segmentos corporales a escala real que se utilizan como recursos docentes para el estudio de la anatomía humana, generando así modelos docentes de alta verosimilitud que sirven como alternativa al uso de preparaciones cadavéricas para la docencia anatómica. En este trabajo presentamos los resultados obtenidos al utilizar nuestro kit KAN3D que incluye réplicas físicas de secciones transversales del tronco y de las extremidades y una plataforma que aloja los modelos digitales debidamente rotulados, producto financiado con el proyecto FONDEF IT16I10073. La aplicación de estos productos en docencia señalan que las réplicas de secciones transversales de segmentos corporales presentan una alta verosimilitud en términos de forma, color, topografía y texturas, características que las validan como un excelente recurso docente para la docencia y el aprendizaje de la anatomía seccional humana. El kit KAN3D pone a disposición de los estudiantes de las carreras de la salud recursos de alta verosimilitud, disponibles a libre demanda, que les permita reproducir la experiencia de la actividad práctica de Morfología en el momento y lugar en que ellos se encuentren dispuestos, superando así las limitaciones de acceso a los pabellones de Anatomía y a material cadavérico de calidad.


Anatomy courses constitute an essential component of the medical curriculum, providing the morphological basis for the clinical examination, the interpretation of medical images and the safe practice of surgical interventions and procedures. Recently, 3D printing technology has allowed to generate replicas of dissections of body segments on a real scale that are used as teaching resources for the study of human anatomy, thus generating high-likelihood teaching models that serve as an alternative to the use of cadaveric preparations for Anatomical teaching. In this paper we present the results obtained by using our KAN3D kit that includes physical replicas of cross sections of the trunk and extremities and a platform that houses properly labeled digital models, a product financed with the FONDEF IT16I10073 project. The application of these products in teaching indicate that replicas of cross sections of body segments have a high likelihood in terms of shape, color, topography and textures, characteristics that validate them as an excellent teaching resource for teaching and learning the human sectional anatomy. The KAN3D kit makes available to students of health careers a high-likelihood resources, accesible on demand, that allows them to reproduce the experience of the practical activity of Morphology at the time and place where they are willing, exceeding thus the limitations of access to the Anatomy pavilions and quality cadaveric material.


Assuntos
Humanos , Software , Anatomia Transversal/educação , Educação Médica/métodos , Impressão Tridimensional , Anatomia/educação
6.
ARS med. (Santiago, En línea) ; 42(2): 34-41, 2017. Tab, ilus
Artigo em Espanhol | LILACS | ID: biblio-1016581

RESUMO

Resumen: El aprendizaje de los estudiantes de Medicina de Pregrado en ambiente simulado constituye una alternativa en la obtención de competencias técnicas y no técnicas. Objetivo: Desarrollar un fantoma e implementar un taller modular de entrenamiento de paracentesis abdominal en ambiente simulado para estudiantes de Medicina. Métodos: Se diseñaron y desarrollaron modelos para la realización de paracentesis abdominal en la Escuela de Diseño de la Pontificia Universidad Católica de Chile (PUC) y se implementó un taller para alumnos de 4to año de Medicina de la PUC, utilizando un enfoque constructivista, sesiones de entrenamiento simulado con debriefing basadas en el modelo plus-delta y evaluación pre y post-procedimiento siguiendo los principios de evaluación para el aprendizaje. Resultados: Se desarrollaron 3 prototipos hasta llegar a un modelo definitivo de alta fidelidad basado en la percepción de 20 expertos. 237 alumnos asistieron a un taller de paracentesis abdominal en el Centro de Cirugía Experimental y Simulación Universidad Católica (UC). Este consistió en una actividad práctica grupal (7-8 alumnos por sesión) que incluyó: una evaluación pre-sesión, un vídeo instruccional, una demostración en tiempo real en el fantoma por parte de un docente, la realización guiada del procedimiento por parte de los alumnos, debriefing y cierre de la sesión. Conclusiones: Un modelo de enseñanza en ambiente simulado es posible de ser diseñado e implementado exitosamente en un centro educacional para estudiantes de Medicina de Pregrado. Este taller de paracentesis permite entrenar a los alumnos en la realización de paracentesis abdominal en un ambiente seguro para los alumnos y pacientes y puede ser implementado a bajo costo en otros centros o instituciones. (AU)


Abstract: Simulated environments are an option in the learning process of undergraduate medical students in order to obtain technical and non-technical. Aim: To develop a mannequin for abdominal paracentesis and the implementation of a training workshop to perform abdominal paracentesis in a simulated environment for undergraduate medical students. Methods: The prototypes were designed and developed to perform abdominal paracentesis at the School of Design at the Pontificia Universidad Católica de Chile (PUC) and a workshop was implemented in a course with 4-year medical students at the PUC, using a constructivist approach and simulated training sessions and providing debriefing (based on plus-delta model) and pre-post training assessment following the principles of Assessment for Learning. Results: Three prototypes were developed until the final high-fidelity-mannequin was achieved. The abdominal paracentesis workshop was attended by 237 students at the Universidad Católica (UC) Experimental Surgery and Simulation Center. This was a hands-on group activity (7-8 students per session) including pre-session assessment, instructional video-tape, real-time demonstration of abdominal paracentesis procedure by the clinical teacher, followed by abdominal paracentesis performed by the students, debriefing and closing session. Conclusions: A teaching model in a simulated environment is feasible to be successfully designed and implemented in an educational center for undergraduate medical students. This workshop allows students training process to perform abdominal paracentesis in a safe environment for students and patients and it can be implemented in other centers or institutions with low cost.(AU)


Assuntos
Humanos , Masculino , Feminino , Ensaios Clínicos Adaptados como Assunto , Estudantes de Medicina , Paracentese , Educação Médica , Abdome
7.
Int. j. morphol ; 33(3): 1176-1182, Sept. 2015. ilus
Artigo em Espanhol | LILACS | ID: lil-762605

RESUMO

La dificultades de acceso al material cadavérico han forzado a los anatomistas a reemplazar la disección por el uso de preparaciones tratadas con diversos métodos de conservación y la utilización cada vez más frecuente de modelos anatómicos, elementos de alto costo que pretenden imitar, no siempre con éxito, a las preparaciones cadavéricas. En el último tiempo se han desarrollado métodos de impresión 3D de modelos de segmentos corporales utilizando imágenes de Tomografía Computadorizada o escáner de superficie, de modo que existe la tecnología para poder realizar réplicas de secciones corporales o de disecciones humanas para aplicarlas con fines docentes. En este trabajo presentamos nuestra experiencia en la tecnología de impresión 3D aplicada a la creación de réplicas de secciones corporales humanas, lo que nos ha permitido generar un símil de la sección corporal, real y tangible, que conserva exactamente las proporciones, las relaciones topográficas, la veracidad morfológica y el color, sin posibilidad de descomposición ni contaminación.


The difficulties of access to cadavers have forced anatomists to replace dissections with the use of preparations treated with various methods of conservation and/or anatomical models; high-cost items that intended to imitate - not always successfully - the cadaveric preparations. Recently, new methods have been developed for 3D printing of models of body segments using computed tomography images or scanner surface, so that the technology exists to create replicas of body sections or cadaver dissections to apply for teaching purposes. We present our experience in 3D printing technology applied to create replicas of human body sections, allowing us to generate an accurate reproduction, with real and tangible sections which retain the proportions exactly as well as topographic relations, morphological and color accuracy, without the possibility of decomposition or contamination.


Assuntos
Humanos , Anatomia/educação , Educação Médica/métodos , Modelos Anatômicos , Impressão Tridimensional , Cadáver
8.
J Dermatolog Treat ; 16(3): 142-8, 2005 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-16096179

RESUMO

BACKGROUND: Pimecrolimus cream 1% (Elidel), a non-steroid inhibitor of inflammatory cytokines, is effective in the treatment of atopic dermatitis, without corticosteroid-related side effects such as skin atrophy. It is indicated for twice-daily application. More frequent applications might be expected either to enhance efficacy or increase toxicity. This study compared the safety, efficacy and systemic absorption of pimecrolimus administered twice daily (recommended dose) and four times daily early in the treatment of patients with moderate to severe atopic dermatitis. METHODS: Adolescent and adult patients with moderate to severe atopic dermatitis were randomly assigned to a twice daily (BID) treatment group (n = 24) or a four times daily (QID) group (n = 25). During days 1-7, patients in the QID group applied pimecrolimus four times daily, and patients in the BID group applied pimecrolimus twice daily plus vehicle equivalent twice daily. During days 8-21, all patients were required to use pimecrolimus twice daily and had the option to use up to two further daily treatments (pimecrolimus in the QID group and vehicle equivalent in the BID group). Blood sampling occurred 2, 4, and 6 hours after the first morning application on days 1 and 5 and then prior to the first morning application on days 8 and 15, and any time on day 22. RESULTS: Only 3 (12%) QID patients and 4 (17%) BID patients reported adverse events (primarily mild, transient application-site burning) with no significant difference between treatment groups in the frequency, type, or severity of adverse events. The median daily number of applications in the QID group during days 8-21 when two additional doses were optional remained at four. Pimecrolimus blood levels from a subgroup of 22 patients showed no difference in systemic exposure between the two dosing regimens. All but three (one in the QID group, two in the BID group) patients had blood levels below the limit of quantification; the highest single blood level of pimecrolimus measured in any patient was 1.37 ng/ml (QID group). Both the QID and BID regimens improved the signs and symptoms of atopic dermatitis similarly as measured by improvements in pruritus severity score, Investigator's Global Assessment, Eczema Area and Severity Index, percentage of body surface area affected, and patient's self-assessment of disease control. CONCLUSIONS: The data suggest that increasing pimecrolimus application from twice daily to four times daily to treat moderate to severe atopic dermatitis for up to 3 weeks does not alter the safety profile nor does it increase the efficacy of treatment. Systemic absorption of pimecrolimus applied BID and QID is minimal and is not different between dosing regimens. Patients and physicians familiar with the potential hazards of overuse of topical corticosteroids should be reassured that if pimecrolimus is applied at twice the recommended BID dose for short periods of time, there is no effect on safety, tolerability, or systemic absorption.


Assuntos
Dermatite Atópica/tratamento farmacológico , Fármacos Dermatológicos/administração & dosagem , Tacrolimo/análogos & derivados , Administração Tópica , Adolescente , Adulto , Análise de Variância , Área Sob a Curva , Fármacos Dermatológicos/farmacocinética , Método Duplo-Cego , Feminino , Humanos , Masculino , Pomadas , Estudos Prospectivos , Segurança , Estatísticas não Paramétricas , Tacrolimo/administração & dosagem , Tacrolimo/farmacocinética , Resultado do Tratamento , Estados Unidos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...