Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Am J Cardiol ; 216: 35-42, 2024 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-38185437

RESUMO

Outcomes of robotic-assisted reverse hybrid coronary revascularization (HCR) remain hindered. We aimed to analyze midterm clinical outcomes of robotic-assisted reverse HCR. All consecutive 285 patients who underwent reverse robotic-assisted HCR between September 2005 and July 2021 were included. Reverse HCR comprises percutaneous coronary intervention with stent implantation in non-left anterior descending (LAD) coronary arteries was performed within 30 days before robotic-assisted left internal thoracic artery (LITA) harvesting and LITA-to-LAD manual anastomosis through a 4-cm left minithoracotomy. Dual antiplatelet therapy was not interrupted in any patient. Preoperatively, mean age was 70.2 years (±11.2). Before surgery, 168 patients received 1 stent, 112 patients 2 stents, and 5 patients 3 stents. Intraoperatively, mean operating room time was 5.9 hours (±1); no case was converted to full sternotomy, whereas 9 patients (3.1%) received intraoperative blood product transfusions. Postoperatively, a small incidence of stroke, 1 (0.3%), reoperation for bleeding, 7 (2.4%), blood product transfusions, 48 (16.8%), and hospital stay (4.8 days) was observed. At 30-day follow-up, 1 patient (0.3%) underwent percutaneous coronary intervention with stent on a surgical LITA-LAD anastomosis owing to graft failure. Mean follow-up was 4.2 years. Reported midterm outcomes included all-cause death in 31 patients (10.9%), major adverse cardiovascular and cerebrovascular events in 102 of 285 (35.9%), nonfatal stroke in 2 of 285 (0.7%), myocardial infarction in 17 of 285 (5.9%), and repeat intervention in 50 of 285 patients (17.5%). This single-center study reports effective and safe clinical outcomes at midterm follow-up of reverse HCR procedures for treating multivessel coronary artery disease.


Assuntos
Doença da Artéria Coronariana , Intervenção Coronária Percutânea , Procedimentos Cirúrgicos Robóticos , Acidente Vascular Cerebral , Humanos , Idoso , Resultado do Tratamento , Doença da Artéria Coronariana/cirurgia , Doença da Artéria Coronariana/etiologia , Ponte de Artéria Coronária/métodos , Intervenção Coronária Percutânea/métodos , Acidente Vascular Cerebral/etiologia
2.
EuroIntervention ; 20(1): 45-55, 2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-37994042

RESUMO

BACKGROUND: Patients who are not candidates for traditional coronary artery bypass grafting (CABG) and amenable only for percutaneous coronary intervention (PCI) with stents can receive the "gold standard" left internal thoracic artery (LITA) to left anterior descending artery (LAD) anastomosis through robotic-assisted CABG and PCI to non-LAD coronary targets. AIMS: We aimed to analyse clinical outcomes of robotic-assisted CABG. METHODS: A total of 2,280 consecutive patients who had undergone robotic-assisted CABG between May 2005 and June 2021 were included in our study. Robotic-assisted LITA harvest was followed by LITA-LAD manual anastomosis through a 4 cm left thoracotomy. Hybrid coronary intervention (HCR) consists of stent implantation in a non-LAD coronary artery performed within 7 days after robotic-assisted LITA-LAD. We performed a propensity-adjusted analysis comparison after dividing all robotic-assisted CABG patients into three time periods: 2005-2010, 615 patients; 2011-2016, 904 patients; and 2017-2021, 761 patients. RESULTS: The mean age increased from 64.5 years in the first time period to 65.8 years in the second time period to 68.1 years in the third (p<0.0001). Operative time was progressively reduced in the three periods (6.4; 6.2; 5.5 hours; p<0.001). The incidence of conversion to sternotomy remained similar for each period (1.8%; 1.7%; 1.5%; p=0.53). Thirty-day mortality in the three periods included 9 (1.4%), 9 (1.0%), and 7 (0.9%) patients, respectively (p=0.91), while 8 (0.3%) patients had PCI with stents in the entire group. The mean follow-up for the entire population was 4.2 years. At follow-up, the rates of all-cause death, major adverse cardiac and cerebrovascular events, non-fatal stroke, and repeat revascularisation with stents were significantly decreased from the first to the last period (pË0.0001). CONCLUSIONS: Robotic-assisted CABG and HCR provide good long-term outcomes in patients who are not candidates for conventional CABG.


Assuntos
Doença da Artéria Coronariana , Intervenção Coronária Percutânea , Procedimentos Cirúrgicos Robóticos , Humanos , Pessoa de Meia-Idade , Procedimentos Cirúrgicos Robóticos/efeitos adversos , Intervenção Coronária Percutânea/efeitos adversos , Resultado do Tratamento
3.
Am Heart J Plus ; 34: 100320, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-38510955

RESUMO

Background: Early data on use of catheter-directed therapies (CDT) for treatment of Intermediate or High-Risk pulmonary embolism (PE) show improvement in pulmonary artery systolic pressures (PAsP) and RV/LV ratios. Occasionally a paradoxical rise in PAsP was observed with CDT utilizing ultrasound-assisted thrombolysis (USAT). It is unclear whether this pattern is seen with CDT utilizing mechanical aspiration. Objectives: To investigate and compare the changes in PAsP between those who underwent CDT with USAT to those with mechanical aspiration. Methods: A retrospective analysis of those diagnosed with Intermediate or High-Risk PE who underwent CDT using USAT or mechanical aspiration from 7/2013 to 3/2023. The primary outcome was comparison of PAsP changes between the two modalities. Secondary outcomes include length of stay, mortality, and bleeding complications. Results: A total of 142 patients were analyzed, of which 93 underwent USAT and 49 underwent mechanical thrombectomy. The mechanical thrombectomy group had significantly lower post-intervention PAsP than the USAT group (42.2 ± 13.4 mmHg vs 54.5 ± 15.2 mmHg, p < 0.0001) and a greater adjusted mean reduction (-16.5 ± 2.7 vs. -7.7 ± 3.2 mmHg. p < 0.0001). A higher frequency of a paradoxical rise in PAsP was observed in the USAT group (22 % vs 4.1 %, p < 0.001). Conclusions: CDT utilizing mechanical thrombectomy was associated with lower post-interventional PAsP and greater mean negative change compared to USAT. Occasional paradoxical rises in PAsP were observed with both types of CDT, but they were more frequent with USAT. Hemodynamic monitoring should be considered after CDT. Condensed unstructured abstract: We report a retrospective comparison of changes to pulmonary artery systolic pressures (PAsPs) between catheter-directed ultrasound-assisted thrombolysis (USAT) and catheter-directed mechanical thrombectomy in Intermediate and High-Risk pulmonary embolism. Those treated with mechanical thrombectomy compared to USAT had significantly lower post-interventional PAsP (42.2 ± 13.4 mmHg vs 54.5 ± 15.2 mmHg, p < 0.0001) and a greater adjusted mean reduction (-16.2 ± 2.7 vs. -7.5 ± 3.2 mmHg, p < 0.0001). A paradoxical rise in PAsP was observed more frequently in the USAT group than the mechanical thrombectomy group (22 % vs 4.1 %, p < 0.001).

4.
Perfusion ; : 2676591221137760, 2022 Nov 12.
Artigo em Inglês | MEDLINE | ID: mdl-36373765

RESUMO

INTRODUCTION: Femoral-femoral Veno-Venous ExtraCorporeal Life Support (V-V ECLS) has been associated with higher infections rates, vascular site bleeding complications, and restricted patient mobility. Jugular or bicaval dual lumen V-V ECLS conceptually overcomes some of these adverse factors, but experience has shown that jugular vein cannulation still limits mobility and has increased bleeding complications. Technique and outcomes of subclavian vein single-cannulation with Crescent jugular dual-lumen V-V ECLS is described. METHOD: five patients with COVID-19 related acute respiratory distress syndrome (ARDS) underwent right subclavian vein V-V ECLS placement with the Crescent 32 French jugular dual-lumen V-V ECLS catheter. A standardized percutaneous technique was developed that allowed efficient insertion without need for any specialized imaging (i.e. transesophageal echocardiogram) and outcomes assessed. RESULTS: Mean age of the five patients was 41.2 years, all obese with an average basal mass index of 45.2 kg/m2 and mean days to decannulation of 24.2 days. Outcomes discovered included; improved patient mobility allowing physical rehabilitation, no vascular access site related complications requiring surgery or endovascular intervention, and none had evidence of superior vena cava syndrome. One patient had subclavian/axillary vein thrombosis with resolution after 3 months of direct-acting oral anticoagulants, and one patient had blood cultures positive at day 37, nearing decannulation. CONCLUSION: Subclavian vein access for crescent jugular dual lumen V-V ECLS catheter appears to be safe and feasible with added benefits of decreased bleeding and increased mobility over jugular or femoral-femoral access site for long term V-V ECLS support in COVID-19 related ARDS patients.

5.
Am J Case Rep ; 23: e936584, 2022 Jun 11.
Artigo em Inglês | MEDLINE | ID: mdl-35689374

RESUMO

BACKGROUND Management of atrial fibrillation (AF) with rapid ventricular rate in the setting of submassive pulmonary emboli (PE) has not been well defined in the literature. It is challenging as the hemodynamics caused by a PE can change the management of AF. We report a case of bilateral PE masked by new-onset AF with rapid ventricular rate that was treated pharmaceutically and mechanically, with thrombectomy. CASE REPORT An 85-year-old man presented with gradual dyspnea and was found to be in AF with rapid ventricular rate (~160-180 bpm). The patient had tachypnea and hypoxia requiring oxygen administration. On physical examination, he had euvolemia. Chest X-ray did not reveal pulmonary vascular congestion. He was started on standard AF management with atrioventricular nodal blockers. Laboratory tests revealed a normal troponin level but mildly elevated B-type natriuretic peptide and lactate. Because his dyspnea was out of proportion to the physical examination, radiographic, and laboratory findings, a D-dimer level was obtained and was elevated. Computed tomography with pulmonary angiogram showed extensive bilateral PE. An echocardiogram (TTE) showed evidence of right ventricular failure. The patient underwent mechanical thrombectomy with clot retrieval, deterring the risk of hemodynamic collapse that would have ensued with atrioventricular nodal blockers monotherapy. On repeat TTE, right ventricular dysfunction was completely resolved and the remaining hospitalization was uneventful. CONCLUSIONS In patients with concomitant AF with rapid ventricular rate and submassive PE, the use of mechanical thrombectomy, in addition to the standard AF management, could be beneficial in deterring the risk of hemodynamic collapse.


Assuntos
Fibrilação Atrial , Embolia Pulmonar , Choque , Disfunção Ventricular Direita , Idoso de 80 Anos ou mais , Fibrilação Atrial/complicações , Dispneia , Humanos , Masculino , Embolia Pulmonar/complicações , Embolia Pulmonar/diagnóstico , Embolia Pulmonar/terapia , Trombectomia/métodos , Disfunção Ventricular Direita/etiologia
6.
CES odontol ; 34(2): 188-199, jul.-dic. 2021. graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1374788

RESUMO

Abstract Ameloblastoma is a benign neoplasm, originated from the odontogenic epithelium. It preferentially affects the mandible and due to its infiltrative growth pattern, it has a tendency to local recurrence. Treatment varies based on clinical, histological and radiographic characteristics. The aggressive treatment, such as marginal resection, has shown good results, however, it also has greater morbidity. Conservative treatments, such as decompression, enucleation and curettage, can also be used, with specific indications, and when carefully performed, it has a good prognosis. Thus, the objective of this work is to describe a case of mandibular ameloblastoma, treated in a more conservative way. Male patient, 53 years old, presented an increase in volume in the anterior region of the mandible. The clinical and radiographic characteristics suggested that it was a cystic lesion, so decompression and incisional biopsy were performed, the diagnosis of which was cystic ameloblastoma. The decompression device was maintained until bone neoformation was no longer observed, with conservative marginal resection being performed, followed by peripheral ostectomy.


Resumo O ameloblastoma é uma neoplasia benigna, originada no epitélio odontogênico. Afeta preferencialmente a mandíbula e, devido ao seu padrão de crescimento infiltrativo, tem tendência à recorrência local. O tratamento varia com base nas características clínicas, histológicas e radiográficas. O tratamento agressivo, como a ressecção marginal, tem mostrado bons resultados, porém também apresenta maior morbidade. Tratamentos conservadores, como descompressão, enucleação e curetagem, também podem ser utilizados, com indicações específicas e, quando realizados com cuidado, apresentam bom prognóstico. Assim, o objetivo deste trabalho é descrever um caso de ameloblastoma mandibular, tratado de maneira mais conservadora. Paciente do sexo masculino, 53 anos, apresentou aumento de volume na região anterior da mandíbula. As características clínicas e radiográficas sugeriram que se tratava de uma lesão cística, pelo que foram realizadas descompressão e biópsia incisional, cujo diagnóstico era ameloblastoma cístico. O dispositivo de descompressão foi mantido até que a neoformação óssea não fosse mais observada, com ressecção marginal conservadora sendo realizada, seguida de ostectomia periférica.


Resumen El ameloblastoma es una neoplasia benigna, originada del epitelio odontogénico. Afecta preferentemente a la mandíbula y, debido a su patrón de crecimiento infiltrativo, tiene tendencia a la recurrencia local. El tratamiento varía según las características clínicas, histológicas y radiográficas. El tratamiento agresivo, como la resección marginal, ha mostrado buenos resultados, sin embargo, también tiene una mayor morbilidad. Los tratamientos conservadores, como la descompresión, la enucleación y el legrado, también se pueden utilizar, con indicaciones específicas, y cuando se realiza con cuidado, tiene un buen pronóstico. Por lo tanto, el objetivo de este trabajo es describir un caso de ameloblastoma mandibular, tratado de una manera más conservadora. Paciente masculino, de 53 años, presentó un aumento de volumen en la región anterior de la mandíbula. Las características clínicas y radiográficas sugirieron que se trataba de una lesión quística, por lo que se realizó descompresión y biopsia incisional, cuyo diagnóstico fue ameloblastoma quístico. El dispositivo de descompresión se mantuvo hasta que ya no se observó neoformación ósea, realizándose una resección marginal conservadora, seguida de ostectomía periférica.

7.
JACC Case Rep ; 2(7): 1036-1041, 2020 Jun 17.
Artigo em Inglês | MEDLINE | ID: mdl-34317410

RESUMO

We discuss a patient who presented with cardiogenic shock secondary to massive pulmonary embolism and right ventricular failure. She was managed by a multidisciplinary heart team and treated with catheter-directed thrombectomy, followed by ProtekDuo (Tandem [Liva Nova], London, United Kingdom) heart percutaneous right ventricular support leading to complete recovery from this often fatal condition. (Level of Difficulty: Intermediate.).

8.
J Am Heart Assoc ; 7(9)2018 04 23.
Artigo em Inglês | MEDLINE | ID: mdl-29686029

RESUMO

BACKGROUND: Outcomes in peripartum cardiomyopathy (PPCM) vary. We sought to determine whether severity of left or right ventricular dysfunction (RVD) at PPCM diagnosis differentially associates with adverse outcomes. METHODS AND RESULTS: We conducted a single-center retrospective cohort study of 53 patients with PPCM. The primary outcome was a composite of left ventricular assist device implantation, cardiac transplantation, or death. We used Kaplan-Meier curves to examine event-free survival and Cox proportional hazards models to examine associations of left ventricular (LV) ejection fraction <30%, LV end-diastolic diameter ≥60 mm, and moderate-to-severe RVD at PPCM diagnosis with the primary outcome. Median (interquartile range) follow-up time was 3.6 (1.4-7.3) years. Seventeen patients (32%) experienced the primary outcome, of whom 11 had moderate-to-severe RVD at time of PPCM diagnosis. Overall event-free survival differed by initial RVD severity and LV ejection fraction <30%, but not by LV end-diastolic diameter ≥60 mm. In univariable analyses, LV ejection fraction <30% and moderate-to-severe RVD were associated with the outcome (hazard ratios [95% confidence intervals] of 4.85 [1.11-21.3] and 4.26 [1.47-11.6], respectively). In a multivariable model with LV ejection fraction <30%, LV end-diastolic diameter ≥60 mm, and moderate-to-severe RVD, only moderate-to-severe RVD was independently associated with the outcome (hazard ratio [95% confidence interval], 3.21 [1.13-9.10]). Although most outcomes occurred within the first year, nearly a third occurred years after PPCM diagnosis. CONCLUSIONS: Initial moderate-to-severe RVD is associated with a more advanced cardiomyopathy phenotype and increased risk of adverse outcomes in PPCM, within and beyond the first year of diagnosis. By identifying a worse PPCM phenotype, initial moderate-to-severe RVD may prompt earlier consideration of advanced heart replacement therapies.


Assuntos
Cardiomiopatias/fisiopatologia , Disfunção Ventricular Direita/fisiopatologia , Função Ventricular Direita , Adulto , Cardiomiopatias/diagnóstico por imagem , Cardiomiopatias/mortalidade , Cardiomiopatias/terapia , Feminino , Transplante de Coração , Coração Auxiliar , Humanos , Período Periparto , Fenótipo , Gravidez , Intervalo Livre de Progressão , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Índice de Gravidade de Doença , Fatores de Tempo , Disfunção Ventricular Direita/diagnóstico por imagem , Disfunção Ventricular Direita/mortalidade , Disfunção Ventricular Direita/terapia , Função Ventricular Esquerda , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...