Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Dose Response ; 19(2): 1559325820984938, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33958978

RESUMO

INTRODUCTION: Oncologic patients who develop chemotherapy-associated liver injury (CALI) secondary to chemotherapy treatment tend to have worse outcomes. Biopsy remains the gold standard for the diagnosis of hepatic steatosis. The purpose of this article is to compare 2 alternatives: Proton-Density-Fat-Fraction (PDFF) MRI and MultiMaterial-Decomposition (MMD) DECT. MATERIALS AND METHODS: 49 consecutive oncologic patients treated with Chemotherapy underwent abdominal DECT and abdominal MRI within 2 weeks of each other. Two radiologists tracked Regions of Interest independently both in the PDFF fat maps and in the MMD DECT fat maps. Non-parametric exact Wilcoxon signed rank test and Cohen's K were used to compare the 2 sequences and to evaluate the agreement. RESULTS: There was no statistically significant difference in the fat fraction measured as a continuous value between PDFF and DECT between 2 readers. Within the same imaging method (PDFF) the degree of agreement based on the k coefficient between reader 1 and reader 2 is 0.88 (p-value < 0.05). Similarly, for single-source DECT(ssDECT) the degree of agreement based on the k coefficient between reader 1 and reader 2 is 0.97 (p-value < 0.05). CONCLUSIONS: The results of this study demonstrate that the hepatic fat fraction of ssDECT with MMD are not significantly different from PDFF. This could be an advantage in an oncological population that undergoes serial CT scans for follow up of chemotherapy response.

2.
Eur J Radiol ; 102: 102-108, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-29685522

RESUMO

PURPOSE: Clinical applications of dual energy computed tomography (DECT) have been widely reported; however, the importance of the different image reconstructions and radiation organ dose remains a relevant area of investigation, particularly considering the different commercially available DECT equipment. Therefore, the purpose of this study was to assess the image reliability and compare the information content between several image reconstructions in a rapid-switching DECT (rsDECT), and assess radiation organ dose between rsDECT and conventional single-energy computed tomography (SECT) exams. MATERIALS AND METHODS: This Institutional Review Board-approved retrospective study included 98 consecutive patients who had a history of liver cancer and underwent multiphasic liver CT exams with rsDECT applied during the late arterial phase between June 2015 and December 2015. Virtual monochromatic 70 keV, material density images (MDI) iodine (-water) and virtual unenhanced (VUE) images were generated. Radiation dose analysis was performed in a subset of 44 patients who had also undergone a multiphasic SECT examination within 6 months of the rsDECT. Four board-certified abdominal radiologists reviewed 24-25 patients each, and a fifth radiologist re-evaluated all the scans to reach a consensus. The following imaging aspects were assessed by the radiologists: (a) attenuation measurements were made in the liver and spleen in VUE and true unenhanced (TUE) images; (b) subjective evaluation for lesion detection and conspicuity on MDI iodine (-water)/VUE images compared with the virtual monochromatic images/TUE images; and (c) overall image quality using a five-point Likert scale. The radiation dose analyses were evaluated in the subset of 44 patients regarding the following parameters: CTDIvol, dose length product, patient's effective diameter and organ dose using a Monte Carlo-based software, VirtualDose™ (Virtual Phantoms, Inc.) to 21 organs. RESULTS: On average, image noise on the TUE images was 49% higher within the liver (p < 0.0001) and 48% higher within the spleen (p < 0.0001). CT numbers for the spleen were significantly higher on VUE images (p < 0.0001). Twenty-eight lesions in 24/98 (24.5%) patients were not observed on the VUE images. The conspicuity of vascular anatomy was considered better on MDI iodine (-water) Images 26.5% of patients. Using the Likert scale, the rsDECT image quality was considered to be satisfactory. Considering the subset of 44 patients with recent SECT, the organ dose was, on average, 37.4% less with rsDECT. As the patient's effective diameter decreased, the differences in dose between the rsDECT and SECT increased, with the total average organ dose being less by 65.1% when rsDECT was used. CONCLUSION: VUE images in the population had lower image noise than TUE images; however, a few small and hyperdense findings were not characterized on VUE images. Delineation of vascular anatomy was considered better in around a quarter of patients on MDI iodine (-water) images. Finally, radiation dose, particularly organ dose, was found to be lower with rsDECT, especially in smaller patients.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Neoplasias Hepáticas/diagnóstico por imagem , Doses de Radiação , Tomografia Computadorizada por Raios X/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Iodo , Fígado/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Reprodutibilidade dos Testes , Estudos Retrospectivos , Adulto Jovem
3.
Acad Radiol ; 25(7): 825-832, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-29373213

RESUMO

RATIONALE AND OBJECTIVES: To determine the impact of second-opinion assessment on cancer staging and patient management in patients with pancreatic ductal adenocarcinoma. METHODS AND MATERIALS: This retrospective study was approved by our institutional review board with a waiver of informed consent. Second-opinion reports between January 1, 2009 and December 31, 2013, alongside outside reports for 65 consecutive cases of biopsy-proven pancreatic adenocarcinomas, were presented in random order to two experienced abdominal surgeons who independently reviewed them blinded to the origin of the report, images of the examinations, and patient identifier. Each surgeon filled in a questionnaire for each report recommending cancer staging and patient management. Recommended patient management and staging were evaluated against reference standards (actual patient management at 6 months following second-opinion assessment, and pathology or other clinical and imaging reference standards at 6 months or longer, respectively) using Cohen kappa. RESULTS: Cancer staging differed in 13% (9 of 65) of cases for surgeon 1 and in 18.4% (12 of 65) for surgeon 2. Patient management changed in 38.4% (25 of 65) of cases for surgeon 1 and in 20% (13 of 65) for surgeon 2. When compared to the pathologic staging gold standard, second opinion was correct in 85.7% (six of seven) of the time for both surgeons. Recommended patient management from second-opinion reports showed good agreement with the reference standard (weighted k = 0.6467 [0.4014-0.892] and weighted k = 0.6262 [0.3954-0.857] for surgeon 2). CONCLUSION: Second-opinion review by subspecialized oncologic radiologists can impact patient care, specifically in terms of management decision.


Assuntos
Carcinoma Ductal Pancreático/diagnóstico por imagem , Carcinoma Ductal Pancreático/terapia , Neoplasias Pancreáticas/diagnóstico por imagem , Neoplasias Pancreáticas/terapia , Encaminhamento e Consulta , Adulto , Idoso , Idoso de 80 Anos ou mais , Carcinoma Ductal Pancreático/patologia , Tomada de Decisão Clínica , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Estadiamento de Neoplasias , Variações Dependentes do Observador , Neoplasias Pancreáticas/patologia , Estudos Retrospectivos , Tomografia Computadorizada por Raios X
4.
Clin Nucl Med ; 41(1): e68-9, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26462043

RESUMO

A 72-year-old man with history of lung cancer and melanoma was referred for routine follow-up with 18F-FDG PET/CT. CT images showed a new mass in the right groin associated with mild FDG activity on 18F-FDG PET images. Subsequent ultrasound obtained the same day demonstrated flow within the lesion to be a pseudoaneurysm of the right femoral artery.


Assuntos
Falso Aneurisma/diagnóstico por imagem , Artéria Femoral , Fluordesoxiglucose F18 , Achados Incidentais , Tomografia por Emissão de Pósitrons , Tomografia Computadorizada por Raios X , Idoso , Humanos , Neoplasias Pulmonares/diagnóstico por imagem , Masculino , Melanoma/diagnóstico por imagem , Imagem Multimodal , Tomografia por Emissão de Pósitrons/métodos , Compostos Radiofarmacêuticos , Tomografia Computadorizada por Raios X/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...