1.
Optom Vis Sci ; 97(2): 101-103, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-32011582

RESUMO

SIGNIFICANCE: Use of anterior segment optical coherence tomography (OCT) is reported, exploring its advantages over other examination techniques. PURPOSE: The purpose of this study was to report a case in which anterior segment OCT was used to evaluate the presence of intraocular bodies after corneal perforation. CASE REPORT: A 33-year-old man was referred to our ophthalmology department after traumatic ocular injury. Swept-source anterior segment was carried out showing corneal perforation and anterior lens capsule rupture. CONCLUSIONS: Evaluating the integrity of posterior capsule and iris after traumatic ocular injury with corneal perforation using anterior segment OCT is a valuable tool to rule out the presence of intraocular foreign bodies without contact and without using radiating imaging techniques.


Assuntos
Segmento Anterior do Olho/diagnóstico por imagem , Perfuração da Córnea/diagnóstico por imagem , Corpos Estranhos no Olho/diagnóstico por imagem , Adulto , Humanos , Masculino , Tomografia de Coerência Óptica/métodos
SELEÇÃO DE REFERÊNCIAS