Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 88
Filtrar
1.
Crit Care ; 28(1): 174, 2024 05 23.
Artigo em Inglês | MEDLINE | ID: mdl-38783367

RESUMO

BACKGROUND: Dyspnea is a key symptom of de novo acute hypoxemic respiratory failure. This study explores dyspnea and its association with intubation and mortality in this population. METHODS: This was a secondary analysis of a multicenter, randomized, controlled trial. Dyspnea was quantified by a visual analog scale (dyspnea-VAS) from zero to 100 mm. Dyspnea was measured in 259 of the 310 patients included. Factors associated with intubation were assessed with a competing risks model taking into account ICU discharge. The Cox model was used to evaluate factors associated with 90-day mortality. RESULTS: At baseline (randomization in the parent trial), median dyspnea-VAS was 46 (interquartile range, 16-65) mm and was ≥ 40 mm in 146 patients (56%). The intubation rate was 45%. Baseline variables independently associated with intubation were moderate (dyspnea-VAS 40-64 mm) and severe (dyspnea-VAS ≥ 65 mm) dyspnea at baseline (sHR 1.96 and 2.61, p = 0.023), systolic arterial pressure (sHR 2.56, p < 0.001), heart rate (sHR 1.94, p = 0.02) and PaO2/FiO2 (sHR 0.34, p = 0.028). 90-day mortality was 20%. The cumulative probability of survival was lower in patients with baseline dyspnea-VAS ≥ 40 mm (logrank test, p = 0.049). Variables independently associated with mortality were SAPS 2 ≥ 25 (p < 0.001), moderate-to-severe dyspnea at baseline (p = 0.073), PaO2/FiO2 (p = 0.118), and treatment arm (p = 0.046). CONCLUSIONS: In patients admitted to the ICU for de novo acute hypoxemic respiratory failure, dyspnea is associated with a higher risk of intubation and with a higher mortality. TRIAL REGISTRATION: clinicaltrials.gov Identifier # NCT01320384.


Assuntos
Dispneia , Insuficiência Respiratória , Humanos , Dispneia/etiologia , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Insuficiência Respiratória/terapia , Insuficiência Respiratória/mortalidade , Insuficiência Respiratória/etiologia , Insuficiência Respiratória/fisiopatologia , Intubação Intratraqueal/estatística & dados numéricos , Intubação Intratraqueal/métodos , Hipóxia/terapia , Hipóxia/fisiopatologia , Hipóxia/complicações , Unidades de Terapia Intensiva/estatística & dados numéricos , Unidades de Terapia Intensiva/organização & administração , Modelos de Riscos Proporcionais
2.
PLoS One ; 19(4): e0302298, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38635540

RESUMO

OBJECTIVE: Underdosing of antibiotics is common in patients with sickle cell disease (SCD). We hypothesized that in critically-ill patients with SCD receiving cefotaxime during acute chest syndrome, the continuous infusion may outperform the intermittent administration in achieving pharmacokinetic/pharmacodynamic targets. DESIGN: Prospective before-after study. SETTINGS: Intensive-care unit of a French teaching hospital and sickle cell disease referral center. PATIENTS: Sixty consecutive episodes of severe acute chest syndrome in 58 adult patients with sickle cell disease. INTERVENTIONS: Patients were treated with intermittent administration during the first period (April 2016 -April 2018) and with continuous infusion during the second period (May 2018 -August 2019). MEASUREMENTS AND MAIN RESULTS: We included 60 episodes of acute chest syndrome in 58 patients (29 [25-34] years, 37/58 (64%) males). Daily dose of cefotaxime was similar between groups (59 [48-88] vs. 61 [57-64] mg/kg/day, p = 0.84). Most patients (>75%) presented a glomerular hyperfiltration with no difference between groups (p = 0.25). More patients had a cefotaxime trough level ≥2 mg/L with continuous infusion than intermittent administration: 28 (93%) vs. 5 (16%), p<0.001. The median residual concentration was higher in the continuous infusion than intermittent administration group: 10.5 [7.4-13.3] vs. 0 [0-0] mg/L, p<0.001. No infection relapse was observed in the entire cohort. Hospital length of stay was similar between groups. CONCLUSION: As compared to intermittent administration, continuous infusion of cefotaxime maximizes the pharmacokinetic/pharmacodynamic parameters in patients with SCD. The clinical outcome did not differ between the two administration methods; however, the study was underpowered to detect such a difference.


Assuntos
Síndrome Torácica Aguda , Anemia Falciforme , Masculino , Adulto , Humanos , Feminino , Cefotaxima/uso terapêutico , Síndrome Torácica Aguda/tratamento farmacológico , Estudos Prospectivos , Antibacterianos/farmacologia , Anemia Falciforme/tratamento farmacológico , Infusões Intravenosas , Estado Terminal/terapia
3.
Am J Respir Crit Care Med ; 209(5): 517-528, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38259196

RESUMO

Rationale: Sepsis management relies on fluid resuscitation avoiding fluid overload and its related organ congestion. Objectives: To explore the influence of country income group on risk-benefit balance of fluid management strategies in sepsis. Methods: We searched e-databases for all randomized controlled trials on fluid resuscitation in patients with sepsis or septic shock up to January 2023, excluding studies on hypertonic fluids, colloids, and depletion-based interventions. The effect of fluid strategies (higher versus lower volumes) on mortality was analyzed per income group (i.e., low- and middle-income countries [LMICs] or high-income countries [HICs]). Measurements and Main Results: Twenty-nine studies (11,798 patients) were included in the meta-analysis. There was a numerically higher mortality in studies of LMICs as compared with those of HICs: median, 37% (interquartile range [IQR]: 26-41) versus 29% (IQR: 17-38; P = 0.06). Income group significantly interacted with the effect of fluid volume on mortality: Higher fluid volume was associated with higher mortality in LMICs but not in HICs: odds ratio (OR), 1.47; 95% confidence interval (95% CI): 1.14-1.90 versus 1.00 (95% CI: 0.87-1.16), P = 0.01 for subgroup differences. Higher fluid volume was associated with increased need for mechanical ventilation in LMICs (OR, 1.24 [95% CI: 1.08-1.43]) but not in HICs (OR, 1.02 [95% CI: 0.80-1.29]). Self-reported access to mechanical ventilation also significantly influenced the effect of fluid volume on mortality, which increased with higher volumes only in settings with limited access to mechanical ventilation (OR: 1.45 [95% CI: 1.09-1.93] vs. 1.09 [95% CI: 0.93-1.28], P = 0.02 for subgroup differences). Conclusions: In sepsis trials, the effect of fluid resuscitation approach differed by setting, with higher volume of fluid resuscitation associated with increased mortality in LMICs and in settings with restricted access to mechanical ventilation. The precise reason for these differences is unclear and may be attributable in part to resource constraints, participant variation between trials, or other unmeasured factors.


Assuntos
Sepse , Choque Séptico , Humanos , Bases de Dados Factuais , Hidratação , Renda , Sepse/terapia , Ensaios Clínicos Controlados Aleatórios como Assunto
4.
Aust Crit Care ; 37(4): 600-605, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38267269

RESUMO

BACKGROUND: Tidal volume (Vt) delivery during mechanical ventilation is influenced by gas compression, humidity, and temperature. OBJECTIVES: This bench study aimed at assessing the accuracy of Vt delivery by paediatric intensive care ventilators according to the humidification system. Secondary objectives were to assess the following: (i) the accuracy of Vt delivery in ventilators with an integrated Y-piece pneumotachograph and (ii) the ability of ventilators to deliver and maintain a preset positive end-expiratory pressure. METHODS: Six latest-generation intensive care ventilators equipped with a paediatric mode were tested on the ASL5000 test lung in four simulated paediatric bench models (full-term neonate, infant, preschool-age chile, and school-age child), under volume-controlled mode with a heated humidifier (HH) or a heat moisture exchanger, with various loading conditions. Three ventilators equipped with a Y-piece pneumotachograph were tested with or without the pneumotachograph in the neonatal and infant models. "Accurate Vt" delivery was defined as a volume error (percentage of the preset Vt under body temperature and pressure and saturated water vapour conditions) being ≤10 % of the absolute preset value. RESULTS: Vt accuracy varied significantly across ventilators but was acceptable in almost all the ventilators and all the models, except the neonatal model. The humidification system had an impact on Vt delivery in the majority of the tested conditions (p < 0.05). The use of an HH was associated with a better Vt accuracy in four ventilators (V500, V800, R860, and ServoU) and allowed to achieve an acceptable level of volume error in the neonatal model as compared to the use of heat moisture exchanger. The use of an integrated pneumotachograph was associated with lower volume error in only one ventilator (p < 0.01). All the tested ventilators were able to maintain adequate positive end-expiratory pressure levels. CONCLUSION: The humidification system affects Vt accuracy of paediatric intensive care ventilators, especially in the youngest patients for whom the HH should be preferred.


Assuntos
Volume de Ventilação Pulmonar , Ventiladores Mecânicos , Humanos , Recém-Nascido , Lactente , Desenho de Equipamento , Respiração Artificial , Criança , Unidades de Terapia Intensiva Pediátrica , Pré-Escolar , Umidade
6.
Ann Intensive Care ; 13(1): 116, 2023 Nov 25.
Artigo em Inglês | MEDLINE | ID: mdl-38006434

RESUMO

BACKGROUND: Multiple devices are available for noninvasive oxygenation support, including non-rebreather oxygen mask (O2-mask), high-flow oxygen through nasal cannula (HFNC), continuous positive airway pressure (CPAP), mask noninvasive ventilation (Mask-NIV) and helmet NIV (Helmet-NIV). As tidal volume is a key determinant of efficacy and safety during ventilatory support, we assessed whether it was influenced by the type of noninvasive oxygenation device. METHODS: A bench study using a manikin with a realistic face connected to a lung simulator was performed. Six conditions were assessed: no device, O2-mask, HFNC, CPAP, Mask-NIV and Helmet-NIV. Three respiratory mechanics were simulated (normal, obstructive, restrictive), at three simulated efforts (low, moderate, respiratory distress). Flow was recorded at the lung simulator inlet and mouth pressure into the manikin mouth. The same devices were evaluated on healthy volunteers with tidal volume assessed by electrical impedance tomography (EIT). RESULTS: Tidal volume was significantly influenced by oxygenation devices in bench model. As compared to O2-mask, HFNC and CPAP delivered significantly lower tidal volumes (440 ± 352 mL, 414 ± 333 mL and 377 ± 297 mL, respectively), while Mask-NIV or Helmet-NIV were associated with significantly higher tidal volumes (690 ± 321 mL and 652 ± 366 mL, respectively). Tidal volume was strongly correlated with the specific effect of each device on mouth pressure during inspiration: HFNC and CPAP were characterized by a negative PTPmouth (- 0.3 [- 0.8 to - 0.2] and - 0.7 [- 2.2 to - 0.5] cmH2O.sec/cycle, respectively), while Helmet-NIV and Mask-NIV were associated with a positive PTPmouth (4.5 [4.1-4.6] and 6.1 [5.9-7.1] cmH2O.sec/cycle, respectively). Tidal volume was also significantly influenced by oxygenation devices in healthy volunteers, with similar tidal volumes between O2-mask and CPAP (644 [571-764] and 648 [586-770] mL) but higher with HFNC, Mask-NIV and Helmet-NIV (819 [609-918], 1110 [661-1305] and 1086 [833-1243] mL). CONCLUSIONS: Tidal volume is significantly influenced by noninvasive oxygenation support devices, with a strong correlation with the pressure variation generated into the mouth during inspiration. NIV was associated with the highest tidal volumes and CPAP with the lowest ones. Clinical studies are needed to clarify the clinical implications of these effects.

7.
Crit Care ; 27(1): 273, 2023 07 07.
Artigo em Inglês | MEDLINE | ID: mdl-37420282

RESUMO

BACKGROUND: Airway opening pressure (AOP) detection and measurement are essential for assessing respiratory mechanics and adapting ventilation. We propose a novel approach for AOP assessment during volume assist control ventilation at a usual constant-flow rate of 60 L/min. OBJECTIVES: To validate the conductive pressure (Pcond) method, which compare the Pcond-defined on the airway pressure waveform as the difference between the airway pressure level at which an abrupt change in slope occurs at the beginning of insufflation and PEEP-to resistive pressure for AOP detection and measurement, and to compare its respiratory and hemodynamic tolerance to the standard low-flow insufflation method. METHODS: The proof-of-concept of the Pcond method was assessed on mechanical (lung simulator) and physiological (cadavers) bench models. Its diagnostic performance was evaluated in 213 patients, using the standard low-flow insufflation method as a reference. In 45 patients, the respiratory and hemodynamic tolerance of the Pcond method was compared with the standard low-flow method. MEASUREMENTS AND MAIN RESULTS: Bench assessments validated the Pcond method proof-of-concept. Sensitivity and specificity of the Pcond method for AOP detection were 93% and 91%, respectively. AOP obtained by Pcond and standard low-flow methods strongly correlated (r = 0.84, p < 0.001). Changes in SpO2 were significantly lower during Pcond than during standard method (p < 0.001). CONCLUSION: Determination of Pcond during constant-flow assist control ventilation may permit to easily and safely detect and measure AOP.


Assuntos
Insuflação , Humanos , Insuflação/métodos , Pulmão , Fenômenos Fisiológicos Respiratórios , Mecânica Respiratória , Respiração Artificial/métodos
8.
Crit Care ; 27(1): 262, 2023 07 04.
Artigo em Inglês | MEDLINE | ID: mdl-37403149

RESUMO

BACKGROUND: Several noninvasive ventilatory supports rely in their design on high oxygen consumption which may precipitate oxygen shortage, as experienced during the COVID-19 pandemic. In this bench-to-bedside study, we assessed the performance of a new continuous positive airway pressure (CPAP) device integrating a large reservoir ("Bag-CPAP") designed to minimize oxygen consumption, and compared it with other CPAP devices. METHODS: First, a bench study compared the performances of Bag-CPAP and four CPAP devices with an intensive care unit ventilator. Two FiO2 targets (40-60% and 80-100%) at a predefined positive end expiratory pressure (PEEP) level between 5 and 10 cm H2O were tested and fraction of inspired oxygen (FiO2) and oxygen consumption were measured. Device-imposed work of breathing (WOB) was also evaluated. Second, an observational clinical study evaluated the new CPAP in 20 adult patients with acute respiratory failure in two hospitals in France. Actual FiO2, PEEP, peripheral oxygen saturation, respiratory rate, and dyspnea score were assessed. RESULTS: All six systems tested in the bench study reached the minimal FiO2 target of 40% and four reached at least 80% FiO2 while maintaining PEEP in the predefined range. Device-delivered FiO2/consumed oxygen ratio was the highest with the new reservoir-based CPAP irrespective of FiO2 target. WOB induced by the device was higher with Bag-CPAP. In the clinical study, Bag-CPAP was well tolerated and could reach high (> 90%) and moderate (> 50%) FiO2 with an oxygen flow rate of 15 [15-16] and 8 [7-9] L/min, respectively. Dyspnea score improved significantly after introduction of Bag-CPAP, and SpO2 increased. CONCLUSIONS: In vitro, Bag-CPAP exhibited the highest oxygen saving properties albeit had increased WOB. It was well accepted clinically and reduced dyspnea. Bag-CPAP may be useful to treat patients with acute respiratory failure in the field, especially when facing constraints in oxygen delivery.


Assuntos
COVID-19 , Insuficiência Respiratória , Adulto , Humanos , Pressão Positiva Contínua nas Vias Aéreas , COVID-19/terapia , Dispneia , Oxigênio , Consumo de Oxigênio , Pandemias , Insuficiência Respiratória/terapia
9.
Ann Intensive Care ; 13(1): 45, 2023 May 25.
Artigo em Inglês | MEDLINE | ID: mdl-37225933

RESUMO

BACKGROUND: The implantation of venovenous extracorporeal membrane oxygenation (VV-ECMO) support to manage severe acute respiratory distress syndrome generates large variations in carbon dioxide partial pressure (PaCO2) that are associated with intracranial bleeding. We assessed the feasibility and efficacy of a pragmatic protocol for progressive dual titration of sweep gas flow and minute ventilation after VV-ECMO implantation in order to limit significant PaCO2 variations. PATIENTS AND METHODS: A protocol for dual titration of sweep gas flow and minute ventilation following VV-ECMO implantation was implemented in our unit in September 2020. In this single-centre retrospective before-after study, we included patients who required VV-ECMO from March, 2020 to May, 2021, which corresponds to two time periods: from March to August, 2020 (control group) and from September, 2020 to May, 2021 (protocol group). The primary endpoint was the mean absolute change in PaCO2 in consecutive arterial blood gases samples drawn over the first 12 h following VV-ECMO implantation. Secondary endpoints included large (> 25 mmHg) initial variations in PaCO2, intracranial bleedings and mortality in both groups. RESULTS: Fifty-one patients required VV-ECMO in our unit during the study period, including 24 in the control group and 27 in the protocol group. The protocol was proved feasible. The 12-h mean absolute change in PaCO2 was significantly lower in patients of the protocol group as compared with their counterparts (7 mmHg [6-12] vs. 12 mmHg [6-24], p = 0.007). Patients of the protocol group experienced less large initial variations in PaCO2 immediately after ECMO implantation (7% vs. 29%, p = 0.04) and less intracranial bleeding (4% vs. 25%, p = 0.04). Mortality was similar in both groups (35% vs. 46%, p = 0.42). CONCLUSION: Implementation of our protocol for dual titration of minute ventilation and sweep gas flow was feasible and associated with less initial PaCO2 variation than usual care. It was also associated with less intracranial bleeding.

11.
Crit Care ; 27(1): 176, 2023 05 08.
Artigo em Inglês | MEDLINE | ID: mdl-37158963

RESUMO

INTRODUCTION: Electrical impedance tomography (EIT) can be used to assess ventilation/perfusion (V/Q) mismatch within the lungs. Several methods have been proposed, some of them neglecting the absolute value of alveolar ventilation (VA) and cardiac output (QC). Whether this omission results in acceptable bias is unknown. METHODS: Pixel-level V/Q maps of 25 ARDS patients were computed once considering (absolute V/Q map) and once neglecting (relative V/Q map) the value of QC and VA. Previously published indices of V/Q mismatch were computed using absolute V/Q maps and relative V/Q maps. Indices computed with relative V/Q maps were compared to their counterparts computed using absolute V/Q maps. RESULTS: Among 21 patients with ratio of alveolar ventilation to cardiac output (VA/QC) > 1, relative shunt fraction was significantly higher than absolute shunt fraction [37% (24-66) vs 19% (11-46), respectively, p < 0.001], while relative dead space fraction was significantly lower than absolute dead space fraction [40% (22-49) vs 58% (46-84), respectively, p < 0.001]. Relative wasted ventilation was significantly lower than the absolute wasted ventilation [16% (11-27) vs 29% (19-35), respectively, p < 0.001], while relative wasted perfusion was significantly higher than absolute wasted perfusion [18% (11-23) vs 11% (7-19), respectively, p < 0.001]. The opposite findings were retrieved in the four patients with VA/QC < 1. CONCLUSION: Neglecting cardiac output and alveolar ventilation when assessing V/Q mismatch indices using EIT in ARDS patients results in significant bias, whose direction depends on the VA/QC ratio value.


Assuntos
Respiração , Síndrome do Desconforto Respiratório , Humanos , Impedância Elétrica , Perfusão , Tomografia Computadorizada por Raios X , Débito Cardíaco , Pulmão
13.
Trials ; 24(1): 232, 2023 Mar 27.
Artigo em Inglês | MEDLINE | ID: mdl-36973743

RESUMO

BACKGROUND: Proportional assist ventilation with load-adjustable gain factors (PAV+) is a mechanical ventilation mode that delivers assistance to breathe in proportion to the patient's effort. The proportional assistance, called the gain, can be adjusted by the clinician to maintain the patient's respiratory effort or workload within a normal range. Short-term and physiological benefits of this mode compared to pressure support ventilation (PSV) include better patient-ventilator synchrony and a more physiological response to changes in ventilatory demand. METHODS: The objective of this multi-centre randomized controlled trial (RCT) is to determine if, for patients with acute respiratory failure, ventilation with PAV+ will result in a shorter time to successful extubation than with PSV. This multi-centre open-label clinical trial plans to involve approximately 20 sites in several continents. Once eligibility is determined, patients must tolerate a short-term PSV trial and either (1) not meet general weaning criteria or (2) fail a 2-min Zero Continuous Positive Airway Pressure (CPAP) Trial using the rapid shallow breathing index, or (3) fail a spontaneous breathing trial (SBT), in this sequence. Then, participants in this study will be randomized to either PSV or PAV+ in a 1:1 ratio. PAV+ will be set according to a target of muscular pressure. The weaning process will be identical in the two arms. Time to liberation will be the primary outcome; ventilator-free days and other outcomes will be measured. DISCUSSION: Meta-analyses comparing PAV+ to PSV suggest PAV+ may benefit patients and decrease healthcare costs but no powered study to date has targeted the difficult to wean patient population most likely to benefit from the intervention, or used consistent timing for the implementation of PAV+. Our enrolment strategy, primary outcome measure, and liberation approaches may be useful for studying mechanical ventilation and weaning and can offer important results for patients. TRIAL REGISTRATION: ClinicalTrials.gov NCT02447692 . Prospectively registered on May 19, 2015.


Assuntos
Suporte Ventilatório Interativo , Respiração Artificial , Humanos , Respiração Artificial/efeitos adversos , Respiração Artificial/métodos , Suporte Ventilatório Interativo/efeitos adversos , Desmame do Respirador/métodos , Respiração com Pressão Positiva/métodos , Respiração , Ensaios Clínicos Controlados Aleatórios como Assunto , Estudos Multicêntricos como Assunto
14.
Am J Respir Crit Care Med ; 207(9): 1126-1133, 2023 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-36716353

RESUMO

The COVID-19 crisis was characterized by a massive need for respiratory support, which has unfortunately not been met globally. This situation mimicked those which gave rise to critical care in the past. Since the polio epidemic in the 50's, the technological evolution of respiratory support has enabled health professionals to save the lives of critically-ill patients worldwide every year. However, much of the current innovation work has turned around developing sophisticated, complex, and high-cost standards and approaches whose resilience is still questionable upon facing constrained environments or contexts, as seen in resuscitation work outside intensive care units, during pandemics, or in low-income countries. Ventilatory support is an essential life-saving tool for patients with respiratory distress. It requires an oxygen source combined to a ventilatory assistance device, an adequate monitoring system, and properly trained caregivers to operate it. Each of these elements can be subject to critical constraints, which we can no longer ignore. The innovation process should incorporate them as a prima materia, whilst focusing on the core need of the field using the concept of frugal innovation. Having a universal access to oxygen and respiratory support, irrespective of the context and constraints, necessitates: i) developing cost-effective, energy-efficient, and maintenance-free oxygen generation devices; ii) improving the design of non-invasive respiratory devices (for example, with oxygen saving properties); iii) conceiving fully frugal ventilators and universal monitoring systems; iv) broadening ventilation expertise by developing end-user training programs in ventilator assistance. The frugal innovation approach may give rise to a more resilient and inclusive critical care system. This paradigm shift is essential for the current and future challenges.


Assuntos
COVID-19 , Humanos , COVID-19/epidemiologia , Pandemias , Cuidados Críticos , Unidades de Terapia Intensiva , Oxigênio
15.
Crit Care ; 26(1): 350, 2022 11 12.
Artigo em Inglês | MEDLINE | ID: mdl-36371306

RESUMO

Spontaneous pneumomediastinum (SP) has been described early during the COVID-19 pandemic in large series of patients with severe pneumonia, but most patients were receiving invasive mechanical ventilation (IMV) at the time of SP diagnosis. In this retrospective multicenter observational study, we aimed at describing the prevalence and outcomes of SP during severe COVID-19 with pneumonia before any IMV, to rule out mechanisms induced by IMV in the development of pneumomediastinum.Among 549 patients, 21 patients (4%) developed a SP while receiving non-invasive respiratory support, after a median of 6 days [4-12] from ICU admission. The proportion of patients requiring IMV was similar. However, the time to tracheal intubation was longer in patients with SP (6 days [5-13] vs. 2 days [1-4]; P = 0.00002), with a higher first-line use of non-invasive ventilation (n = 11; 52% vs. n = 150; 28%; P = 0.02). The 21 patients who developed a SP had persisting signs of severe lung disease and respiratory failure with lower ROX index between ICU admission and occurrence of SP (3.94 [3.15-5.55] at admission vs. 3.25 [2.73-4.02] the day preceding SP; P = 0.1), which may underline potential indirect signals of Patient-self inflicted lung injury (P-SILI).In this series of critically ill COVID-19 patients, the prevalence of SP without IMV was not uncommon, affecting 4% of patients. They received more often vasopressors and had a longer ICU length of stay, as compared with their counterparts. One pathophysiological mechanism may potentially be carried out by P-SILI related to a prolonged respiratory failure, as underlined by a delayed use of IMV and the evolution of the ROX index between ICU admission and the day preceding SP.


Assuntos
COVID-19 , Enfisema Mediastínico , Insuficiência Respiratória , Humanos , COVID-19/complicações , COVID-19/terapia , Pandemias , Estado Terminal/epidemiologia , Estado Terminal/terapia , SARS-CoV-2 , Enfisema Mediastínico/epidemiologia , Enfisema Mediastínico/terapia , Respiração Artificial , Estudos Retrospectivos
16.
Front Cardiovasc Med ; 9: 948231, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36225952

RESUMO

Background: Low-dose steroids are known to increase arterial pressure during septic shock through restoration of vasopressor response to norepinephrine. However, their effects on cardiac performance and ventriculo-arterial coupling (VAC) have never been scrutinized during human septic shock. The aim of this study was to perform a comprehensive description of the cardiovascular effects of low-dose steroids using modern echocardiographic tools (including speckle tracking imaging). Methods: This prospective study was conducted in the intensive care unit (ICU) of a university hospital in France. Consecutive adult patients admitted for septic shock and requiring low-dose steroid therapy were prospectively enrolled within 24 h of septic shock onset. We recorded hemodynamic and echocardiographic data to explore left ventricle (LV) contractility, loading conditions and VAC just before the initiation of low-dose steroids (50 mg intravenous hydrocortisone plus 50 µg enteral fludrocortisone) and 2-4 h after. Results: Fifty patients [65 (55-73) years; 33 men] were enrolled. Arterial pressure, heart rate, almost all LV afterload parameters, and most cardiac contractility parameters significantly improved after steroids. VAC improved with steroid therapy and less patients had uncoupled VAC (> 1.36) after (24%) than before (44%) treatment. Conclusion: In this comprehensive echocardiographic study, we confirmed an improvement of LV afterload after initiation of low-dose steroids. We also observed an increase in LV contractility with improved cardiovascular efficiency (less uncoupling with decreased VAC).

17.
Front Cardiovasc Med ; 9: 951016, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36158835

RESUMO

Background: The role of dobutamine during septic shock resuscitation is still controversial. Methods: The aim of this prospective multicentre study was to comprehensively characterize the hemodynamic response of septic shock patients with systolic myocardial dysfunction to incremental doses of dobutamine (0, 5, 10, and 15 µg/kg/min). Results: Thirty two patients were included in three centers. Dobutamine significantly increased contractility indices of both ventricles [crude and afterload-adjusted left ventricular (LV) ejection fraction, global LV longitudinal peak systolic strain, tissue Doppler peak systolic wave at mitral and tricuspid lateral annulus, and tricuspid annular plane excursion) as well as global function indices (stroke volume and cardiac index) and diastolic function (increased e' and decreased E/e' ratio at lateral mitral annulus). Dobutamine also induced a significant decrease in arterial pressure and cardiac afterload indices (effective arterial elastance, systemic vascular resistance and diastolic shock index). Oxygen transport, oxygen consumption and carbon dioxide production all increased with dobutamine, without change in the respiratory quotient or lactate. Dobutamine was discontinued for poor tolerance in a majority of patients (n = 21, 66%) at any dose and half of patients (n = 15, 47%) at low-dose (5 µg/kg/min). Poor tolerance to low-dose dobutamine was more frequent in case of acidosis, was associated with lower vasopressor-free days and survival at day-14. Conclusion: In patients with septic myocardial dysfunction, dobutamine induced an overall improvement of echocardiographic parameters of diastolic and systolic function, but was poorly tolerated in nearly two thirds of patients, with worsening vasoplegia. Patients with severe acidosis seemed to have a worse response to dobutamine.

18.
JAMA ; 328(12): 1212-1222, 2022 09 27.
Artigo em Inglês | MEDLINE | ID: mdl-36166027

RESUMO

Importance: The benefit of high-flow nasal cannula oxygen (high-flow oxygen) in terms of intubation and mortality in patients with respiratory failure due to COVID-19 is controversial. Objective: To determine whether the use of high-flow oxygen, compared with standard oxygen, could reduce the rate of mortality at day 28 in patients with respiratory failure due to COVID-19 admitted in intensive care units (ICUs). Design, Setting, and Participants: The SOHO-COVID randomized clinical trial was conducted in 34 ICUs in France and included 711 patients with respiratory failure due to COVID-19 and a ratio of partial pressure of arterial oxygen to fraction of inspired oxygen equal to or below 200 mm Hg. It was an ancillary trial of the ongoing original SOHO randomized clinical trial, which was designed to include patients with acute hypoxemic respiratory failure from all causes. Patients were enrolled from January to December 2021; final follow-up occurred on March 5, 2022. Interventions: Patients were randomly assigned to receive high-flow oxygen (n = 357) or standard oxygen delivered through a nonrebreathing mask initially set at a 10-L/min minimum (n = 354). Main Outcomes and Measures: The primary outcome was mortality at day 28. There were 13 secondary outcomes, including the proportion of patients requiring intubation, number of ventilator-free days at day 28, mortality at day 90, mortality and length of stay in the ICU, and adverse events. Results: Among the 782 randomized patients, 711 patients with respiratory failure due to COVID-19 were included in the analysis (mean [SD] age, 61 [12] years; 214 women [30%]). The mortality rate at day 28 was 10% (36/357) with high-flow oxygen and 11% (40/354) with standard oxygen (absolute difference, -1.2% [95% CI, -5.8% to 3.4%]; P = .60). Of 13 prespecified secondary outcomes, 12 showed no significant difference including in length of stay and mortality in the ICU and in mortality up until day 90. The intubation rate was significantly lower with high-flow oxygen than with standard oxygen (45% [160/357] vs 53% [186/354]; absolute difference, -7.7% [95% CI, -14.9% to -0.4%]; P = .04). The number of ventilator-free days at day 28 was not significantly different between groups (median, 28 [IQR, 11-28] vs 23 [IQR, 10-28] days; absolute difference, 0.5 days [95% CI, -7.7 to 9.1]; P = .07). The most common adverse events were ventilator-associated pneumonia, occurring in 58% (93/160) in the high-flow oxygen group and 53% (99/186) in the standard oxygen group. Conclusions and Relevance: Among patients with respiratory failure due to COVID-19, high-flow nasal cannula oxygen, compared with standard oxygen therapy, did not significantly reduce 28-day mortality. Trial Registration: ClinicalTrials.gov Identifier: NCT04468126.


Assuntos
COVID-19 , Oxigenoterapia , Insuficiência Respiratória , COVID-19/complicações , COVID-19/mortalidade , COVID-19/terapia , Cânula/efeitos adversos , Feminino , Humanos , Masculino , Máscaras , Pessoa de Meia-Idade , Oxigênio/administração & dosagem , Oxigenoterapia/efeitos adversos , Insuficiência Respiratória/etiologia , Insuficiência Respiratória/mortalidade , Insuficiência Respiratória/terapia
19.
J Clin Med ; 11(15)2022 Jul 27.
Artigo em Inglês | MEDLINE | ID: mdl-35955983

RESUMO

BACKGROUND: Diagnosis of co/superinfection in patients with Acute Respiratory Distress Syndrome (ARDS) is challenging. The FilmArray Pneumonia plus Panel (bioMérieux, France), a new rapid multiplex Polymerase Chain Reaction (mPCR), has never been assessed on a blinded protected telescope catheter (PTC) samples, a very common diagnostic tool in patients under mechanical ventilation. We evaluated the performance of mPCR on PTC samples compared with conventional culture and its impact on antibiotic stewardship. METHODS: Observational study in two intensive care units, conducted between March and July 2020, during the first wave of the COVID-19 pandemic in France. RESULTS: We performed 125 mPCR on blinded PTC samples of 95 ARDS patients, including 73 (77%) SARS-CoV-2 cases and 28 (29%) requiring extracorporeal membrane oxygenation. Respiratory samples were drawn from mechanically ventilated patients either just after intubation (n = 48; 38%) or later for suspected ventilator-associated pneumonia (VAP) (n = 77; 62%). The sensitivity, specificity, positive, and negative predictive values of mPCR were 93% (95% CI 84-100), 99% (95% CI 99-100), 68% (95% CI 54-83), and 100% (95% CI 100-100), respectively. The overall coefficient of agreement between mPCR and standard culture was 0.80 (95% CI 0.68-0.89). Intensivists changed empirical antimicrobial therapy in only 14% (18/125) of cases. No new antibiotic was initiated in more than half of the CAP/HAP pneumonia-suspected cases (n = 29; 60%) and in more than one-third of those suspected to have VAP without affecting or delaying their antimicrobial therapy. CONCLUSIONS: Rapid mPCR was feasible on blinded PTC with good sensitivity and specificity. New antibiotics were not initiated in more than half of patients and more than one-third of VAP-suspected cases. Further studies are needed to assess mPCR potential in improving antibiotic stewardship.

20.
Crit Care ; 26(1): 185, 2022 06 20.
Artigo em Inglês | MEDLINE | ID: mdl-35725498

RESUMO

BACKGROUND: Whether targeting the driving pressure (∆P) when adjusting the tidal volume in mechanically ventilated patients with the acute respiratory distress syndrome (ARDS) may decrease the risk of ventilator-induced lung injury remains a matter of research. In this study, we assessed the effect of a ∆P-guided ventilation on the mechanical power. METHODS: We prospectively included adult patients with moderate-to-severe ARDS. Positive end expiratory pressure was set by the attending physician and kept constant during the study. Tidal volume was first adjusted to target 6 ml/kg of predicted body weight (PBW-guided ventilation) and subsequently modified within a range from 4 to 10 ml/kg PBW to target a ∆P between 12 and 14 cm H2O. The respiratory rate was then re-adjusted within a range from 12 to 40 breaths/min until EtCO2 returned to its baseline value (∆P-guided ventilation). Mechanical power was computed at each step. RESULTS: Fifty-one patients were included between December 2019 and May 2021. ∆P-guided ventilation was feasible in all but one patient. The ∆P during PBW-guided ventilation was already within the target range of ∆P-guided ventilation in five (10%) patients, above in nine (18%) and below in 36 (72%). The change from PBW- to ∆P-guided ventilation was thus accompanied by an overall increase in tidal volume from 6.1 mL/kg PBW [5.9-6.2] to 7.7 ml/kg PBW [6.2-8.7], while respiratory rate was decreased from 29 breaths/min [26-32] to 21 breaths/min [16-28] (p < 0.001 for all comparisons). ∆P-guided ventilation was accompanied by a significant decrease in mechanical power from 31.5 J/min [28-35.7] to 28.8 J/min [24.6-32.6] (p < 0.001), representing a relative decrease of 7% [0-16]. With ∆P-guided ventilation, the PaO2/FiO2 ratio increased and the ventilatory ratio decreased. CONCLUSION: As compared to a conventional PBW-guided ventilation, a ∆P-guided ventilation strategy targeting a ∆P between 12 and 14 cm H2O required to change the tidal volume in 90% of the patients. Such ∆P-guided ventilation significantly reduced the mechanical power. Whether this physiological observation could be associated with clinical benefit should be assessed in clinical trials.


Assuntos
Síndrome do Desconforto Respiratório , Adulto , Peso Corporal , Humanos , Pulmão , Respiração com Pressão Positiva , Respiração Artificial , Síndrome do Desconforto Respiratório/terapia , Volume de Ventilação Pulmonar/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...