Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 124
Filtrar
1.
Radiologia (Engl Ed) ; 63(6): 495-504, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34801182

RESUMO

OBJECTIVE: Initial COVID-19 reports described a variety of clinical presentations, but lower respiratory abnormalities are most common and chest CT findings differ between adult and pediatric patients. We aim to summarize early CT findings to inform healthcare providers on the frequency of COVID-19 manifestations specific to adult or pediatric patients, and to determine if the sensitivity of CT justifies its use in these populations. METHODS: PubMed was searched for the presence of the words "CT, imaging, COVID-19" in the title or abstract, and 17 large-scale PubMed and/or Scopus studies and case reports published between January 1, 2020 and April 15, 2020 were selected for data synthesis. RESULTS: Initial CT scans identified ground-glass opacities and bilateral abnormalities as more frequent in adults (74%, n = 698, and 89%, n = 378, respectively) than children (60%, n = 25, and 37%, n = 46). At 14+ days, CT scans evidenced varied degrees of improvement in adults but no resolution until at least 26 days after the onset of flu-like symptoms. In pediatric patients, a third (n = 9) showed additional small nodular GGOs limited to a single lobe 3-5 days after an initial CT scan. CONCLUSION: Early adult CT findings suggest the limited use of CT as a supplemental tool in diagnosing COVID-19 in symptomatic adult patients, with a particular focus on identifying right and left lower lobe abnormalities, GGOs, and interlobular septal thickening. Early pediatric CT findings suggest against the use of CT if RT-PCR is available given its significantly lower sensitivity in this population and radiation exposure.


Assuntos
COVID-19 , SARS-CoV-2 , Adulto , Criança , Testes Diagnósticos de Rotina , Humanos , Pulmão , Tomografia Computadorizada por Raios X
2.
Radiologia ; 63(6): 495-504, 2021.
Artigo em Espanhol | MEDLINE | ID: mdl-35368367

RESUMO

Objective: Initial COVID-19 reports described a variety of clinical presentations, but lower respiratory abnormalities are most common and chest CT findings differ between adult and pediatric patients. We aim to summarize early CT findings to inform healthcare providers on the frequency of COVID-19 manifestations specific to adult or pediatric patients, and to determine if the sensitivity of CT justifies its use in these populations. Methods: PubMed was searched for the presence of the words "CT, imaging, COVID-19" in the title or abstract, and 17 large-scale PubMed and/or Scopus studies and case reports published between January 1, 2020 and April 15, 2020 were selected for data synthesis. Results: Initial CT scans identified ground-glass opacities and bilateral abnormalities as more frequent in adults (74%, n = 698, and 89%, n = 378, respectively) than children (60%, n = 25, and 37%, n = 46). At 14+ days, CT scans evidenced varied degrees of improvement in adults but no resolution until at least 26 days after the onset of flu-like symptoms. In pediatric patients, a third (n = 9) showed additional small nodular GGOs limited to a single lobe 3-5 days after an initial CT scan. Conclusión: Early adult CT findings suggest the limited use of CT as a supplemental tool in diagnosing COVID-19 in symptomatic adult patients, with a particular focus on identifying right and left lower lobe abnormalities, GGOs, and interlobular septal thickening. Early pediatric CT findings suggest against the use of CT if RT-PCR is available given its significantly lower sensitivity in this population and radiation exposure.

3.
Clin Radiol ; 75(9): 713.e1-713.e9, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32560907

RESUMO

AIM: To determine if there is a difference in the detection of labral tears and cartilage lesions using the T2-weighted sequences of magnetic resonance arthrography (MRA) only, which simulate MRA with saline alone, compared with the full examination including T1-weighted sequences. MATERIALS AND METHODS: One hundred hip MRA examinations performed at 3 T were identified retrospectively. Each study was reviewed by a musculoskeletal radiologist using either the T2-weighted sequences only (without gadolinium-based contrast agent [GBCA] effect) or the entire examination, including T1-weighted sequences (with GBCA effect). Receiver operating characteristic (ROC) curves were calculated for both groups and compared within a non-inferiority framework, using - 0.10 as the limit of non-inferiority. RESULTS: For labral tears, the difference area under the curve (AUC) was -0.004 (95% confidence interval [CI]: -0.064-0.056, p=0.90). For acetabular cartilage lesions, the difference AUC was 0.011 (95% CI: -0.073-0.096, p=0.79). For femoral cartilage lesions, the difference AUC was -0.059 (95% CI: -0.206-0.087, p=0.43). CONCLUSION: T2-weighted sequences alone were not inferior in diagnostic accuracy compared with the full examination (including T1-weighted sequences with intra-articular GBCA) in detecting acetabular cartilage lesions and labral tears. Further study with prospective comparison of saline injectate to GBCA-containing injectate may help clarify the necessity of continued GBCA use in MRA of the hip.


Assuntos
Cartilagem Articular/patologia , Gadolínio/farmacologia , Articulação do Quadril/diagnóstico por imagem , Angiografia por Ressonância Magnética/métodos , Adolescente , Adulto , Meios de Contraste/farmacologia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Curva ROC , Estudos Retrospectivos , Adulto Jovem
4.
AJNR Am J Neuroradiol ; 40(11): 1855-1863, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-31649155

RESUMO

BACKGROUND AND PURPOSE: Despite the frequent use of unenhanced head CT for the detection of acute neurologic deficit, the radiation dose for this exam varies widely. Our aim was to evaluate the performance of lower-dose head CT for detection of intracranial findings resulting in acute neurologic deficit. MATERIALS AND METHODS: Projection data from 83 patients undergoing unenhanced spiral head CT for suspected neurologic deficits were collected. Cases positive for infarction, intra-axial hemorrhage, mass, or extra-axial hemorrhage required confirmation by histopathology, surgery, progression of findings, or corresponding neurologic deficit; cases negative for these target diagnoses required negative assessments by two neuroradiologists and a clinical neurologist. A routine dose head CT was obtained using 250 effective mAs and iterative reconstruction. Lower-dose configurations were reconstructed (25-effective mAs iterative reconstruction, 50-effective mAs filtered back-projection and iterative reconstruction, 100-effective mAs filtered back-projection and iterative reconstruction, 200-effective mAs filtered back-projection). Three neuroradiologists circled findings, indicating diagnosis, confidence (0-100), and image quality. The difference between the jackknife alternative free-response receiver operating characteristic figure of merit at routine and lower-dose configurations was estimated. A lower 95% CI estimate of the difference greater than -0.10 indicated noninferiority. RESULTS: Forty-two of 83 patients had 70 intracranial findings (29 infarcts, 25 masses, 10 extra- and 6 intra-axial hemorrhages) at routine head CT (CT dose index = 38.3 mGy). The routine-dose jackknife alternative free-response receiver operating characteristic figure of merit was 0.87 (95% CI, 0.81-0.93). Noninferiority was shown for 100-effective mAs iterative reconstruction (figure of merit difference, -0.04; 95% CI, -0.08 to 0.004) and 200-effective mAs filtered back-projection (-0.02; 95% CI, -0.06 to 0.02) but not for 100-effective mAs filtered back-projection (-0.06; 95% CI, -0.10 to -0.02) or lower-dose levels. Image quality was better at higher-dose levels and with iterative reconstruction (P < .05). CONCLUSIONS: Observer performance for dose levels using 100-200 eff mAs was noninferior to that observed at 250 effective mAs with iterative reconstruction, with iterative reconstruction preserving noninferiority at a mean CT dose index of 15.2 mGy.


Assuntos
Encefalopatias/diagnóstico por imagem , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada Espiral/métodos , Algoritmos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Curva ROC , Adulto Jovem
5.
AJNR Am J Neuroradiol ; 39(9): 1733-1738, 2018 09.
Artigo em Inglês | MEDLINE | ID: mdl-30093479

RESUMO

BACKGROUND AND PURPOSE: Evaluating abnormalities of the temporal bone requires high-spatial-resolution CT imaging. Our aim was to assess the performance of photon-counting-detector ultra-high-resolution acquisitions for temporal bone imaging and compare the results with those of energy-integrating-detector ultra-high-resolution acquisitions. MATERIALS AND METHODS: Phantom studies were conducted to quantify spatial resolution of the ultra-high-resolution mode on a prototype photon-counting-detector CT scanner and an energy-integrating-detector CT scanner that uses a comb filter. Ten cadaveric temporal bones were scanned on both systems with the radiation dose matched to that of the clinical examinations. Images were reconstructed using a sharp kernel, 0.6-mm (minimum) thickness for energy-integrating-detector CT, and 0.6- and 0.25-mm (minimum) thicknesses for photon-counting-detector CT. Image noise was measured and compared using adjusted 1-way ANOVA. Images were reviewed blindly by 3 neuroradiologists to assess the incudomallear joint, stapes footplate, modiolus, and overall image quality. The ranking results for each specimen and protocol were compared using the Friedman test. The Krippendorff α was used for interreader agreement. RESULTS: Photon-counting-detector CT showed an increase of in-plane resolution compared with energy-integrating-detector CT. At the same thickness (0.6 mm), images from photon-counting-detector CT had significantly lower (P < .001) image noise compared with energy-integrating-detector CT. Readers preferred the photon-counting-detector CT images to the energy-integrating-detector images for all 3 temporal bone structures. A moderate interreader agreement was observed with the Krippendorff α = 0.50. For overall image quality, photon-counting-detector CT image sets were ranked significantly higher than images from energy-integrating-detector CT (P < .001). CONCLUSIONS: This study demonstrated substantially better delineation of fine anatomy for the temporal bones scanned with the ultra-high-resolution mode of photon-counting-detector CT compared with the ultra-high-resolution mode of a commercial energy-integrating-detector CT scanner.


Assuntos
Osso Temporal/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Cadáver , Humanos , Imagens de Fantasmas , Fótons
6.
AJNR Am J Neuroradiol ; 38(4): 672-677, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28183836

RESUMO

BACKGROUND AND PURPOSE: Given the positive impact of early intervention for craniosynostosis, CT is often performed for evaluation but radiation dosage remains a concern. We evaluated the potential for substantial radiation dose reduction in pediatric patients with suspected craniosynostosis. MATERIALS AND METHODS: CT projection data from pediatric patients undergoing head CT for suspected craniosynostosis were archived. Simulated lower-dose CT images corresponding to 25%, 10%, and 2% of the applied dose were created using a validated method. Three neuroradiologists independently interpreted images in a blinded, randomized fashion. All sutures were evaluated by using 3D volume-rendered images alone, and subsequently with 2D and 3D images together. Reference standards were defined by reader agreement by using routine dose and 2D and 3D images. Performance figures of merit were calculated based on reader response and confidence. RESULTS: Of 33 pediatric patients, 21 had craniosynostosis (39 positive sutures and 225 negative sutures). The mean volume CT dose index was 15.5 ± 2.3 mGy (range, 9.69-19.38 mGy) for the routine dose examination. Average figures of merit for multireader analysis ranged from 0.92 (95% CI, 0.90-0.95) at routine pediatric dose to 0.86 (95% CI, 0.79-0.94) at 2% dose using 3D images alone. Similarly, pooled reader figures of merit ranged from 0.91 (95% CI, 0.89-0.95) at routine pediatric dose to 0.85 (95% CI, 0.76-0.95) at 2% dose using 2D and 3D images together. At 25% and 10% dose, 95% CI of the difference in figures of merit from routine dose included 0, suggesting similar or noninferior performance. CONCLUSIONS: For pediatric head CT for evaluation of craniosynostosis, dose reductions of 75%-90% were possible without compromising observer performance.


Assuntos
Craniossinostoses/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Feminino , Humanos , Imageamento Tridimensional/métodos , Masculino , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador/métodos
7.
AJNR Am J Neuroradiol ; 36(9): 1599-603, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25999413

RESUMO

BACKGROUND AND PURPOSE: Radiation dose in temporal bone CT imaging can be high due to the requirement of high spatial resolution. In this study, we assessed whether CT imaging of the temporal bone by using an ultra-high-resolution scan mode combined with iterative reconstruction provides higher spatial resolution and lower image noise than a z-axis ultra-high-resolution mode. MATERIALS AND METHODS: Patients with baseline temporal bone CT scans acquired by using a z-axis ultra-high-resolution protocol and a follow-up scan by using the ultra-high-resolution-iterative reconstruction technique were identified. Images of left and right temporal bones were reconstructed in the axial, coronal, and Poschl planes. Three neuroradiologists assessed the spatial resolution of the following structures: round and oval windows, incudomallear and incudostapedial joints, basal turn spiral lamina, and scutum. The paired z-axis ultra-high-resolution and ultra-high-resolution-iterative reconstruction images were displayed side by side in random order, with readers blinded to the imaging protocol. Image noise was compared in ROIs over the posterior fossa. RESULTS: We identified 8 patients, yielding 16 sets of temporal bone images (left and right). Three sets were excluded because the patient underwent surgery between the 2 examinations. Spatial resolution was comparable (Poschl) or slightly better (axial and coronal planes) with ultra-high-resolution-iterative reconstruction than with z-axis ultra-high-resolution. A paired t test indicated that noise was significantly lower with ultra-high-resolution-iterative reconstruction than with z-axis ultra-high-resolution (P < .001), with a mean noise reduction of 37% (range, 18%-49%). CONCLUSIONS: The ultra-high-resolution-iterative reconstruction scan mode has similar or slightly better resolution relative to the z-axis ultra-high-resolution mode for CT of the temporal bone but significantly (P < .01) lower image noise, which may enable the dose to be reduced by approximately 50%.


Assuntos
Algoritmos , Osso Temporal/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Doses de Radiação
8.
AJNR Am J Neuroradiol ; 36(3): 594-9, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25614474

RESUMO

BACKGROUND AND PURPOSE: The Patient Reported Outcomes Measurement Information System is a newly developed outcomes measure promulgated by the National Institutes of Health. This study compares changes in pain and physical function-related measures of this system with changes on the Numeric Rating Pain Scale, Roland Morris Disability Index, and the European Quality of Life scale 5D questionnaire in patients undergoing transformational epidural steroid injections for radicular pain. MATERIALS AND METHODS: One hundred ninety-nine patients undergoing transforaminal epidural steroid injections for radicular pain were enrolled in the study. Before the procedure, they rated the intensity of their pain by using the 0-10 Numeric Rating Pain Scale, Roland Morris Disability Index, and European Quality of Life scale 5D questionnaire. Patients completed the Patient Reported Outcomes Measurement Information System Physical Function, Pain Behavior, and Pain Interference short forms before transforaminal epidural steroid injections and at 3 and 6 months. Seventy and 43 subjects replied at 3- and 6-month follow-up. Spearman rank correlations were used to assess the correlation between the instruments. The minimally important differences were calculated for each measurement tool as an indicator of meaningful change. RESULTS: All instruments were responsive in detecting changes at 3- and 6-month follow-up (P < .0001). There was significant correlation between changes in Patient Reported Outcomes Measurement Information System scores and legacy questionnaires from baseline to 3 months (P < .05). There were, however, no significant correlations in changes from 3 to 6 months with any of the instruments. CONCLUSIONS: The studied Patient Reported Outcomes Measurement Information System domains offered responsive and correlative psychometric properties compared with legacy instruments in a population of patients undergoing transforaminal epidural steroid injections for radicular pain.


Assuntos
Avaliação de Resultados da Assistência ao Paciente , Radiculopatia/tratamento farmacológico , Adulto , Idoso , Avaliação da Deficiência , Feminino , Humanos , Injeções Epidurais/métodos , Masculino , Pessoa de Meia-Idade , Medição da Dor , Psicometria , Qualidade de Vida , Autocuidado , Resultado do Tratamento , Estados Unidos
9.
Water Res ; 72: 331-9, 2015 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-25448766

RESUMO

Epoxy coatings are commonly used to protect the interior (and exterior) surfaces of water mains and storage tanks and can be used on the interior surfaces of water pipes in homes, hospitals, hotels, and other buildings. Common major components of epoxies include bisphenols, such as bisphenol A (BPA) or bisphenol F (BPF), and their reactive prepolymers, bisphenol A diglycidyl ether (BADGE) and bisphenol F diglycidyl ether (BFDGE), respectively. There currently are health concerns about the safety of BPA and BPF due to known estrogenic effects. Determination of key bisphenol leachates, development of a hydrolysis model, and identification of stable hydrolysis products will aid in assessment of human bisphenol exposure through ingestion of drinking water. Liquid chromatography/mass spectrometry (LC/MS/MS) was used for quantitation of key analytes, and a pseudo-first order kinetic approach was used for modeling. In fill-and-dump studies on epoxy-coated pipe specimens, BADGE and a BPA-like compound were identified as leachates. The BADGE hydrolysis model predicts BADGE half-lives at pH 7 and 15, 25, 35, and 40 °C to be 11, 4.6, 2.0, and 1.4 days respectively; the BFDGE half-life was 5 days at pH 7 and 25 °C. The two identified BADGE hydrolysis products are BADGE-H2O and BADGE 2H2O, with BADGE 2H2O being the final end product under the conditions studied.


Assuntos
Compostos Benzidrílicos/química , Água Potável/química , Compostos de Epóxi/química , Fenóis/química , Cromatografia Líquida , Cromatografia Gasosa-Espectrometria de Massas , Meia-Vida , Hidrólise , Cinética , Limite de Detecção
10.
AJNR Am J Neuroradiol ; 36(3): 587-93, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25395656

RESUMO

BACKGROUND AND PURPOSE: In patients with intramedullary spinal cord metastases, the impact of MR imaging and clinical characteristics on survival has not been elucidated. Our aim was to identify MR imaging and clinical features with prognostic value among patients with intramedullary spinal cord metastases from a large retrospective series. MATERIALS AND METHODS: The relevant MR imaging examination and baseline clinical data for each patient from a consecutive group of patients with intramedullary spinal cord metastases had previously been reviewed by 2 neuroradiologists. Additional relevant clinical data were extracted. The influence of clinical and imaging characteristics on survival was assessed by Kaplan-Meier survival curves and log-rank tests for categoric characteristics. RESULTS: Forty-nine patients had 70 intramedullary spinal cord metastases; 10 (20%) of these patients had multiple metastases. From the date of diagnosis, median survival for all patients was 104 days (95% CI, 48-156 days). One clinical feature was associated with decreased median survival: lung or breast primary malignancy (57 days) compared with all other malignancy types (308 days; P < .001). Three MR imaging features were associated with decreased median survival: multiple intramedullary spinal cord metastases (53 versus 121 days, P = .022), greater longitudinal extent of cord T2 hyperintensity (if ≥3 segments, 111 days; if ≤2, 184 days; P = .018), and ancillary visualization of the primary tumor and/or non-CNS metastases (96 versus 316 days, P = .012). CONCLUSIONS: Spinal cord edema spanning multiple segments, the presence of multifocal intramedullary spinal cord metastases, and ancillary evidence for non-CNS metastases and/or the primary tumor are MR imaging features associated with decreased survival and should be specifically sought. Patients with either a lung or breast primary malignancy are expected to have decreased survival compared with other primary tumor types.


Assuntos
Neoplasias da Medula Espinal/mortalidade , Neoplasias da Medula Espinal/secundário , Idoso , Neoplasias da Mama/patologia , Feminino , Humanos , Estimativa de Kaplan-Meier , Neoplasias Pulmonares/patologia , Imageamento por Ressonância Magnética/métodos , Pessoa de Meia-Idade , Prognóstico , Estudos Retrospectivos , Neoplasias da Medula Espinal/diagnóstico
11.
Clin Neuroradiol ; 24(2): 121-7, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23817770

RESUMO

PURPOSE: Internal jugular vein (IJV) narrowing superiorly is likely relatively frequent. IJV narrowing has been proposed as a potential pathophysiologic component for multiple sclerosis (MS). Our purpose was to investigate the prevalence of incidental superior IJV narrowing in patients imaged with neck computed tomography angiography (CTA) for reasons unrelated to IJV pathology or MS. METHODS: We retrospectively identified 164 consecutive adult patients who had undergone neck CTA in which at least one IJV superior segment was opacified (158 right, 155 left IJVs). At the narrowest point of the upper IJV, each IJV was assessed for dominance, graded (shape and narrowing), measured (diameter and area), and located (axially and craniocaudally). Associations were analyzed using Spearman rank correlations (p < 0.05 significant). Medical records were reviewed for MS. RESULTS: Among 164 patients, at least one IJV was: absent/pinpoint in 15 % (25/164), occluded/nearly occluded in 26 % (43/164). Shape, narrowing, and the three measurements all correlated with each other (all p < 0.01). Lateral location with respect to C1 transverse foramen correlated with subjectively and objectively smaller IJVs (p < 0.01). The most common craniocaudal location was at the C1 transverse process (79 % (125/158) of right and 81 % (126/155) of left IJVs). No patient had a diagnosis of MS. CONCLUSIONS: The appearance of the superior IJV is variable, with an occlusive/near-occlusive appearance present in approximately one-quarter of patients without known MS undergoing CTA. Radiologists should be aware of and cautious to report or ascribe clinical significance to this frequent anatomic variant.


Assuntos
Veias Jugulares/diagnóstico por imagem , Trombose Venosa/diagnóstico por imagem , Trombose Venosa/epidemiologia , Causalidade , Comorbidade , Feminino , Humanos , Achados Incidentais , Veias Jugulares/anormalidades , Masculino , Pessoa de Meia-Idade , Esclerose Múltipla/diagnóstico , Esclerose Múltipla/epidemiologia , Flebografia/estatística & dados numéricos , Prevalência , Reprodutibilidade dos Testes , Fatores de Risco , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X/estatística & dados numéricos
12.
AJNR Am J Neuroradiol ; 34(10): 2043-9, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23620071

RESUMO

BACKGROUND AND PURPOSE: Because intramedullary spinal cord metastasis is often a difficult diagnosis to make, our purpose was to perform a systematic review of the MR imaging and relevant baseline clinical features of intramedullary spinal cord metastases in a large series. MATERIALS AND METHODS: Consecutive patients with intramedullary spinal cord metastasis with available pretreatment digital MR imaging examinations were identified. The MR imaging examination(s) for each patient was reviewed by 2 neuroradiologists for various imaging characteristics. Relevant clinical data were obtained. RESULTS: Forty-nine patients had 70 intramedullary spinal cord metastases, with 10 (20%) having multiple intramedullary spinal cord metastases; 8% (4/49) were asymptomatic. Primary tumor diagnosis was preceded by intramedullary spinal cord metastasis presentation in 20% (10/49) and by intramedullary spinal cord metastasis diagnosis in 10% (5/49); 98% (63/64) of intramedullary spinal cord metastases enhanced. Cord edema was extensive: mean, 4.5 segments, 3.6-fold larger than enhancing lesion, and ≥3 segments in 54% (37/69). Intratumoral cystic change was seen in 3% (2/70) and hemorrhage in 1% (1/70); 59% (29/49) of reference MR imaging examinations displayed other CNS or spinal (non-spinal cord) metastases, and 59% (29/49) exhibited the primary tumor/non-CNS metastases, with 88% (43/49) displaying ≥1 finding and 31% (15/49) displaying both findings. Patients with solitary intramedullary spinal cord metastasis were less likely than those with multiple intramedullary spinal cord metastases to have other CNS or spinal (non-spinal cord) metastases on the reference MR imaging (20/39 [51%] versus 9/10 [90%], respectively; P = .0263). CONCLUSIONS: Lack of known primary malignancy or spinal cord symptoms should not discourage consideration of intramedullary spinal cord metastasis. Enhancement and extensive edema for lesion size (often ≥3 segments) are typical for intramedullary spinal cord metastasis. Presence of cystic change/hemorrhage makes intramedullary spinal cord metastasis unlikely. Evidence for other CNS or spinal (non-spinal cord) metastases and the primary tumor/non-CNS metastases are common. The prevalence of other CNS or spinal (non-spinal cord) metastases in those with multiple intramedullary spinal cord metastases is especially high.


Assuntos
Carcinoma Neuroendócrino/secundário , Imageamento por Ressonância Magnética , Neoplasias das Glândulas Salivares/patologia , Neoplasias da Medula Espinal/secundário , Neoplasias da Glândula Tireoide/patologia , Adenocarcinoma/secundário , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Neoplasias da Mama/patologia , Criança , Feminino , Humanos , Neoplasias Pulmonares/patologia , Linfoma/patologia , Masculino , Pessoa de Meia-Idade , Neoplasias Ovarianas/patologia , Neoplasias da Próstata/patologia , Estudos Retrospectivos , Carcinoma Anaplásico da Tireoide , Adulto Jovem
13.
AJNR Am J Neuroradiol ; 34(7): 1468-73, 2013 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-23449650

RESUMO

BACKGROUND AND PURPOSE: The prevalence of facet joint signal change in acute/subacute lumbar vertebral body compression fractures is unknown. We hypothesized that facet joint signal change on MR imaging is more common in facet joints associated with an acute/subacute lumbar compression fracture than those associated with normal vertebral bodies or ones that have a chronic compression fracture. MATERIALS AND METHODS: Three neuroradiologists and a neuroradiology fellow retrospectively graded facet joint inflammatory change on MR imaging in 900 facet joints in 75 patients with at least 1 painful osteoporotic lumbar compression fracture. Facet joint signal change was assessed on T2-weighted images with chemical fat-saturation, STIR images, and/or gadolinium-enhanced T1-weighted images with chemical fat-saturation. Each facet joint from the T12/L1 to L5/S1 level was assessed individually. An overall facet joint signal-change score, which is a composite measure of the grade of signal change for all 4 facet joints associated with a given lumbar vertebral level, was devised, and statistical significance was assessed via Wilcoxon rank sum tests. RESULTS: The overall facet joint signal-change scores were significantly higher at vertebral body levels affected by an acute/subacute compression fracture compared with control levels, which were associated with either normal bodies or chronic compression fractures. CONCLUSIONS: Our findings suggest an association between facet joint signal change on MR imaging and acute/subacute lumbar vertebral body compression fractures.


Assuntos
Fraturas por Compressão/diagnóstico , Vértebras Lombares/lesões , Imageamento por Ressonância Magnética/métodos , Fraturas da Coluna Vertebral/diagnóstico , Articulação Zigapofisária/patologia , Doença Aguda , Idoso , Doença Crônica , Meios de Contraste , Feminino , Fraturas por Compressão/patologia , Gadolínio , Humanos , Aumento da Imagem/métodos , Vértebras Lombares/patologia , Masculino , Osteoporose/complicações , Estudos Retrospectivos , Doenças da Coluna Vertebral/complicações , Fraturas da Coluna Vertebral/patologia , Espondilite/diagnóstico , Espondilite/patologia
14.
AJNR Am J Neuroradiol ; 34(2): 451-6, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22878010

RESUMO

BACKGROUND AND PURPOSE: Most studies of HD have been conducted in Asia, particularly Japan. To characterize the MR imaging findings of North American patients with HD, we reviewed neutral and flexion cervical MR imaging examinations performed for possible HD at 3 academic medical centers located in the Southeastern, Southwestern, and Midwestern regions of the United States. MATERIALS AND METHODS: Three neuroradiologists assessed the MR imaging examinations in a blinded fashion and reached a consensus rating for LOA of the posterior dura to the spine, lower spinal cord atrophy, spinal cord T2 hyperintensity, loss of cervical lordosis, anterior dural shift with flexion, and confidence of imaging diagnosis. Final reference diagnosis was established separately with a retrospective chart review by a neurologist. RESULTS: Twenty-one patients met the criteria for HD, all were North American males and all who reported their race were white. Seventeen patients did not meet the criteria and served as controls. Four imaging attributes, LOA, dural shift with flexion, consensus diagnosis of neutral images, and consensus diagnosis of combined neutral and flexion images were all able to discriminate the group with HD from the group without HD (P < .05 for each). Findings of HD were often present on neutral images, but the addition of flexion images increased diagnostic confidence. CONCLUSIONS: MR imaging findings in white North American patients with HD include LOA on neutral images and forward displacement of the dura with flexion. Findings are often present on neutral MR images and, in the appropriate clinical scenario, should prompt flexion MR imaging to evaluate anterior dural shift.


Assuntos
Vértebras Cervicais , Imageamento por Ressonância Magnética/métodos , Medula Espinal/patologia , Atrofias Musculares Espinais da Infância/patologia , Adolescente , Adulto , Atrofia , Reações Falso-Negativas , Humanos , Lordose/patologia , Imageamento por Ressonância Magnética/normas , Imageamento por Ressonância Magnética/estatística & dados numéricos , Masculino , Pessoa de Meia-Idade , Meio-Oeste dos Estados Unidos , Variações Dependentes do Observador , Estudos Retrospectivos , Sensibilidade e Especificidade , Sudeste dos Estados Unidos , Sudoeste dos Estados Unidos , Adulto Jovem
15.
AJNR Am J Neuroradiol ; 34(5): 1035-9, 2013 May.
Artigo em Inglês | MEDLINE | ID: mdl-23099500

RESUMO

BACKGROUND AND PURPOSE: The degree of variation in retreatment decisions for residual or recurrent aneurysms among endovascular therapists remains poorly defined. We performed a multireader study to determine what reader and patient variables contribute to this variation. MATERIALS AND METHODS: Seven endovascular therapists (4 neuroradiologists, 3 neurosurgeons) independently reviewed 66 cases of patients treated with endovascular coil embolization for ruptured or unruptured aneurysm. Cases were rated on a 5-point scale recommending for whether to retreat and a recommended retreatment type. Reader agreement was assessed by intraclass correlation coefficient and by identifying cases with a "clinically meaningful difference" (a difference in score that would result in a difference in treatment). Variables that affect reader agreement and retreatment decisions were examined by using the Wilcoxon signed-rank test, Pearson χ(2) test, and linear regression. RESULTS: Overall interobserver variability for decision to retreat was moderate (ICC = 0.50; 95% CI, 0.40-0.61). Clinically meaningful differences between at least 2 readers were present in 61% of cases and were significantly more common among neuroradiologists than neurosurgeons (P = .0007). Neurosurgeons were more likely to recommend "definitely retreat" than neuroradiologists (P < .0001). Previously ruptured aneurysms, larger remnant size, and younger patients were associated with more retreat recommendations. Interobserver variability regarding retreatment type was fair overall 0.25 (95% CI, 0.14-0.41) but poor for experienced readers 0.14 (95% CI, 0-0.34). CONCLUSIONS: There is a large amount of interobserver variability regarding the decision to retreat an aneurysm and the type of retreatment. This variability must be reduced to increase consistency in these subjective outcome measurements.


Assuntos
Angiografia Cerebral/estatística & dados numéricos , Tomada de Decisões , Procedimentos Endovasculares/estatística & dados numéricos , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/cirurgia , Idoso , Feminino , Humanos , Aneurisma Intracraniano/epidemiologia , Masculino , Pessoa de Meia-Idade , Minnesota/epidemiologia , Variações Dependentes do Observador , Prevalência , Prognóstico , Recidiva , Reoperação/estatística & dados numéricos , Reprodutibilidade dos Testes , Medição de Risco/métodos , Fatores de Risco , Sensibilidade e Especificidade
17.
AJNR Am J Neuroradiol ; 33(4): 690-4, 2012 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-22194380

RESUMO

BACKGROUND AND PURPOSE: Some patients with SIH have fast CSF leaks requiring dynamic CTM for localization; however, patients generally undergo conventional CTM before a dynamic study. Our aim was to determine whether findings on head MR imaging, spine MR imaging, or opening pressure measurements can predict fast spinal CSF leaks. MATERIALS AND METHODS: A retrospective review was performed on 151 consecutive patients referred for CTM to evaluate for spinal CSF leak. Head MR imaging was evaluated for diffuse dural enhancement and "brain sag," and spine MR imaging for presence of an extradural fluid collection. The opening pressure was recorded. The CTM was scored as no leak, slow leak localized on conventional CTM, or fast leak that required dynamic CTM. RESULTS: Fast CSF leaks were identified in 32 (21%), slow leaks in 36 (24%), and no leak in 83 (55%) of 151 patients on initial CTM. There was significant association between spinal extra-arachnoid fluid on MR imaging and the presence of a fast leak (sensitivity 85%, specificity 79%, P < .0001). There was not significant association between fast leak and findings on head MR imaging (P = .27) or opening pressure (P = .30). CONCLUSIONS: If all patients with spinal extra-arachnoid CSF on MR imaging had been sent directly to dynamic CTM, repeat myelography would have been avoided in most patients with fast leaks (23 of 27; 85%). However, a minority of patients with slow or no leaks would have been converted from conventional to dynamic CTM (16 of 77; 21%). Spinal MR imaging is helpful in premyelographic evaluation of SIH.


Assuntos
Hipertensão Intracraniana/diagnóstico por imagem , Hipertensão Intracraniana/epidemiologia , Mielografia/estatística & dados numéricos , Derrame Subdural/diagnóstico por imagem , Derrame Subdural/epidemiologia , Tomografia Computadorizada por Raios X/estatística & dados numéricos , Adulto , Idoso , Comorbidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Minnesota/epidemiologia , Prevalência , Reprodutibilidade dos Testes , Medição de Risco , Fatores de Risco , Sensibilidade e Especificidade
18.
AJNR Am J Neuroradiol ; 33(3): 415-9, 2012 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22207298

RESUMO

BACKGROUND AND PURPOSE: Image-guided cervical transforaminal epidural injections play an important role in the management of cervical radicular pain syndromes. The safety and efficacy of these injections via an anterolateral approach has been well-studied. The goal of this retrospective review was to determine the safety and efficacy of CT-guided transforaminal epidural injections by using a posterior approach. MATERIALS AND METHODS: Retrospective review of patient records was used to define VNPS and RMDI of patients undergoing CT-guided transforaminal cervical epidural injections between 2006 and 2010. Pain scores were recorded preprocedure, immediately postprocedure, at 2 weeks, and at 2 months. The RMDI was recorded preprocedure, at 2 weeks, and at 2 months. Data analysis of 247 patients was completed. Differences in VNPS scores and the RMDI were then compared on the basis of a CT-guided approach (anterolateral versus posterior). RESULTS: There was no statistical difference in the degree of pain relief and improvement in the RMDI between the CT-guided transforaminal anterolateral approach and the posterior approach at 2 weeks and at 2 months. Both groups demonstrated a statistically significant improvement in pain scores and the RMDI. Approximately 35% of patients in both groups demonstrated >50% pain relief at 2 months. There were no serious complications in either group. CONCLUSIONS: CT-guided transforaminal cervical epidural injections by using a posterior approach are safe and effective.


Assuntos
Injeções Epidurais/estatística & dados numéricos , Cervicalgia/tratamento farmacológico , Cervicalgia/epidemiologia , Radiculopatia/tratamento farmacológico , Radiculopatia/epidemiologia , Esteroides/efeitos adversos , Tomografia Computadorizada por Raios X/estatística & dados numéricos , Comorbidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Minnesota/epidemiologia , Medição da Dor/efeitos dos fármacos , Medição da Dor/estatística & dados numéricos , Radiografia Intervencionista/estatística & dados numéricos , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Resultado do Tratamento
19.
Spinal Cord ; 47(8): 592-6, 2009 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-19255586

RESUMO

STUDY DESIGN: Prospective cohort study. OBJECTIVE: To identify the association of social support and socioeconomic factors with risk of early mortality among persons with spinal cord injury. SETTING: Participants were identified from a large specialty hospital in the Southeastern United States. METHODS: Data were collected by mailed survey, and mortality status was ascertained approximately 8 years later. The outcome was time from survey to mortality or censoring. Mortality status was determined using the National Death Index and the Social Security Death Index. There were 224 observed deaths (16.2%) in the full sample (n=1386). Because of missing data, the number of deaths used in the final analysis was 188 (out of 1249 participants). RESULTS: Cox proportional hazards modeling was used to build a comprehensive predictive model. After controlling for biographic and injury-related factors, two of four environmental predictors were retained in the final model including low income and general social support. Years of education and the upsets scale, another aspect of social support, were not retained in the final model. Inclusion of these variables resulted in only modest improvement in the prediction of survival compared with biographic and injury variables alone, as the pseudo-R(2) increased from 0.121 to 0.134 and the concordance from 0.730 to 0.751. CONCLUSION: Environmental factors are important predictors of mortality after spinal cord injury.


Assuntos
Renda , Apoio Social , Traumatismos da Medula Espinal/mortalidade , Adulto , Escolaridade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Modelos de Riscos Proporcionais , Fatores de Risco
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...