Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
J Invest Surg ; 35(4): 776-782, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-34278920

RESUMO

INTRODUCTION: several pancreatectomy techniques in rats have been described and utilized for research concerning the pancreas endocrine and exocrine functions. However, we did not find a description of any kind of laparoscopic pancreatectomy in rats in the consulted databases. The objective of this study is to describe a laparoscopic splenic lobe pancreatectomy in rats. METHODS: ten Wistars rats weighting more then 300 g were operated for standardizing the laparoscopic pancreatosplenectomy technique, aided by previous descriptions of laparoscopic splenectomy and open pancreatectomy in rats. Adjustments have been progressively adopted for technical refinement. RESULTS: In five animals a low-cost rat laparoscopic set was used. In other five animals we used a standard laparoscopic set. Three rats died early due to different causes: transection of the gastroesophageal junction, hemorrhagic shock and inadvertent colonic injury. The postoperative period of the other seven rats was uneventful until the seventh postoperative day. DISCUSSION: laparoscopic distal pancreatectomy and splenectomy in rats is feasible and safe, even with a low-cost set, in which the results were alike the standard laparoscopic set.


Assuntos
Laparoscopia , Neoplasias Pancreáticas , Animais , Laparoscopia/efeitos adversos , Laparoscopia/métodos , Modelos Teóricos , Pancreatectomia/efeitos adversos , Pancreatectomia/métodos , Neoplasias Pancreáticas/cirurgia , Ratos , Ratos Wistar , Esplenectomia/efeitos adversos , Esplenectomia/métodos
2.
Acta Cir Bras ; 33(9): 853-861, 2018 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-30328918

RESUMO

PURPOSE: To evaluate a novel and adapted low-cost set model for laparoscopic surgery in rats. METHODS: Nine Wistar rats underwent two different laparoscopic procedures, splenectomy (n=3) and distal pancreatectomy with splenectomy (n = 6), after assembling a low-cost set replacing the conventional one (monitor, micro camera, image processor, light source, laparoscope and insufflator). The new set included an Android Tablet 10.5 ", a 5mm USB Endoscope and semiautomatic sphygmomanometer monitor. RESULTS: The same surgeon performed the laparoscopic procedures. Total surgical time ranged from 36 to 60 minutes with a mean of 45.8 minutes. Three rats died during the distal pancreatic and splenectomy procedure (33.3%), due to respiratory failure (n = 1), uncontrolled abdominal hemorrhage (n=1) and iatrogenic gastric perforation (n = 1). We followed the other six rats (66.6%) for seven days with no further evidence of complications. CONCLUSIONS: The laparoscopic partial pancreatectomy and splenectomy can be performed with the novel low-cost set assembled in the present experimental study. Both specific training and skills development are required to validate more advanced laparoscopic procedures and achieve a desirable outcome.


Assuntos
Laparoscopia/educação , Pancreatectomia/educação , Esplenectomia/educação , Animais , Custos e Análise de Custo , Laparoscopia/economia , Laparoscopia/métodos , Modelos Animais , Pancreatectomia/economia , Pancreatectomia/métodos , Ratos , Ratos Wistar , Esplenectomia/economia , Esplenectomia/métodos
3.
Acta cir. bras ; 33(9): 853-861, Sept. 2018. tab, graf
Artigo em Inglês | LILACS | ID: biblio-973494

RESUMO

Abstract Purpose: To evaluate a novel and adapted low-cost set model for laparoscopic surgery in rats. Methods: Nine Wistar rats underwent two different laparoscopic procedures, splenectomy (n=3) and distal pancreatectomy with splenectomy (n = 6), after assembling a low-cost set replacing the conventional one (monitor, micro camera, image processor, light source, laparoscope and insufflator). The new set included an Android Tablet 10.5 ", a 5mm USB Endoscope and semiautomatic sphygmomanometer monitor. Results: The same surgeon performed the laparoscopic procedures. Total surgical time ranged from 36 to 60 minutes with a mean of 45.8 minutes. Three rats died during the distal pancreatic and splenectomy procedure (33.3%), due to respiratory failure (n = 1), uncontrolled abdominal hemorrhage (n=1) and iatrogenic gastric perforation (n = 1). We followed the other six rats (66.6%) for seven days with no further evidence of complications. Conclusions: The laparoscopic partial pancreatectomy and splenectomy can be performed with the novel low-cost set assembled in the present experimental study. Both specific training and skills development are required to validate more advanced laparoscopic procedures and achieve a desirable outcome.


Assuntos
Animais , Ratos , Pancreatectomia/educação , Esplenectomia/educação , Laparoscopia/educação , Pancreatectomia/economia , Pancreatectomia/métodos , Esplenectomia/economia , Esplenectomia/métodos , Ratos Wistar , Laparoscopia/economia , Laparoscopia/métodos , Custos e Análise de Custo , Modelos Animais
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...