RESUMO

A new flooring system has been developed to reduce peak impact forces to the hips when humans fall. The new safety floor is designed to remain relatively rigid under normal walking conditions, but to deform elastically when impacted during a fall. Design objectives included minimizing peak force experienced by the femur during a fall-induced impact, while maintaining a maximum of 2 mm of floor deflection during walking. Finite Element Models (FEMs) were developed to capture the complex dynamics of impact response between two deformable bodies. Validation of the finite element models included analytical calculations of theoretical buckling column response, experimental quasi-static loading of full-scale flooring prototypes, and flooring response during walking trials. Finite Element Method results compared well with theoretical and experimental data. Both finite element and experimental data suggest that the proposed safety floor can effectively meet the design goal of 2 mm maximum deflection during walking, while effectively reducing impact forces during a fall.


Assuntos
Acidentes por Quedas , Ergonomia/métodos , Análise de Elementos Finitos , Pisos e Cobertura de Pisos/métodos , Gestão da Segurança/métodos , Caminhada , Força Compressiva , Elasticidade , Desenho de Equipamento , Testes de Dureza , Humanos , Dinâmica não Linear , Poliuretanos/química , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Suporte de Carga
2.
J Biomech Eng ; 120(4): 527-32, 1998 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-10412424

RESUMO

The goal of this study was to develop and validate a finite element model (FEM) for use in the design of a flooring system that would provide a stable walking surface during normal locomotion but would also deform elastically under higher loads, such as those resulting from falls. The new flooring system is designed to reduce the peak force on the femoral neck during a lateral fall onto the hip. The new flooring system is passive in nature and exhibits two distinct stiffnesses. During normal activities, the floor remains essentially rigid. Upon impact, the floor collapses and becomes significantly softer. The flooring system consists of a multitude of columns supporting a continuous walking surface. The columns were designed to remain stiff up to a specific load and, after exceeding this load, to deform elastically. The flooring returns to its original shape after impact. Part I of this study presented finite element and experimental results demonstrating that the floor deflection during normal walking remained less than 2 mm. To facilitate the floor's development further, a nonlinear finite element model simulating the transient-impact response of a human hip against various floor configurations was developed. Nonlinearities included in the finite element models were: changing topology of deformable-body-to-deformable-body contact, snap-through buckling, soft tissue stiffness and damping, and large deformations. Experimental models developed for validating the finite element model included an anthropomorphic hip, an impact delivery mechanism, a data collection system, and four hand-fabricated floor tiles. The finite element model discussed in this study is shown to capture experimentally observed trends in peak femoral neck force reduction as a function of flooring design parameters. This study also indicates that a floor can be designed that deflects minimally during walking and reduces the peak force on the femoral neck during a fall-related impact by 15.2 percent.


Assuntos
Acidentes por Quedas , Ergonomia/métodos , Fraturas do Colo Femoral/etiologia , Fraturas do Colo Femoral/prevenção & controle , Análise de Elementos Finitos , Pisos e Cobertura de Pisos/métodos , Dinâmica não Linear , Análise Numérica Assistida por Computador , Gestão da Segurança/métodos , Elasticidade , Desenho de Equipamento , Humanos , Reprodutibilidade dos Testes , Caminhada