1.
Phys Med ; 94: 35-42, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34995976

RESUMO

PURPOSE: The aim of this work is to present a ready to industrialize low-cost and easy-to-install bleeding detector for use in intraoperative electron radiation therapy (IOERT). The detector works in stand-alone mode and is embedded into a translucent polymethylmethacrylate (PMMA) applicator avoiding any contact with the patient, which represent a novelty compared to previous designs. The use of this detector will prevent dose misadministration during irradiation in the event of accumulation of fluids in the applicator. METHODS: The detector is based on capacitive sensor and wireless power-supply electronics. Both sensor and electronics have been embedded in the applicator, so that any contact with the patient would be avoided. Since access to the tumor can be done through different trajectories, the detector has been calibrated for different tilting angles. RESULTS: The result of the calibration provides us with a fit curve that allows the interpolation of the results at any angle. Comparison of estimated fluid height vs real height gives an error of 1 mm for tilting angles less than 10° and 2 mm for tilting angles greater than 15°. This accuracy is better than the one required by clinic. CONCLUSIONS: The performance of the bleeding detector was evaluated in situ. No interference was observed between the detector and the beam. In addition, a user-friendly mobile application has been developed to help the surgical team making decisions before and during irradiation. The measurement provided by the mobile application was stable during the irradiation process.


Assuntos
Elétrons , Aceleradores de Partículas , Calibragem , Humanos , Período Intraoperatório , Polimetil Metacrilato , Radioterapia , Dosagem Radioterapêutica
2.
Sensors (Basel) ; 21(2)2021 Jan 12.
Artigo em Inglês | MEDLINE | ID: mdl-33445620

RESUMO

This paper proposes an IoT system based on wireless BLE connectivity to monitor the moisture content of wood, using a compact and low-cost moisture device that relies on a resistance measurement method valid for an ultra-wide range of resistance values. This device is digitally controlled with a BLE-incorporated micro-controller characterized by its small size and low power consumption, providing long-life battery. The proposed system consists of two main parts: first, the BLE moisture device including the moisture content measurement and wireless capability (BLE); second, the cloud-based monitoring platform, providing remote visualization and control for all the sensor nodes of the network. The complete infrastructure shows how multiple nodes can read and transmit moisture content of timber in buildings using small and unattended devices, with data saved in a central database and monitored by multiple commercial devices such as PC, smartphone, tablet, etc. The proposed system is innovative, scalable and low cost, and it can be deployed in wooden buildings and the wood industry, providing a practical solution that will help to avoid rot and other damaging effects caused by the moisture content.

3.
Phys Med ; 65: 150-156, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-31473502

RESUMO

PURPOSE: The aim of this work is to improve the potential bleeding detection during intraoperative radiotherapy with linac polymethyl methacrylate applicators (PMMA), based on one previously developed. The improvements carried out have been focused on: i) minimizing the impact of the detector on the visual through the plastic applicators and ii) avoiding the asymmetry in the detection capability when the applicator is tilted. METHODS: Simulations have been made to select the geometry that provides a reduced visual impact on the applicator as well as allowing an independent response with the tilting angle of the applicator. A low-noise circuit for signal conditioning has been developed. Measurements have been made on three setups: 10 cm, 7 cm and 4 cm applicator diameters, 0° and 45° tilted. RESULTS: The detector has a visibility through the applicator greater than 50%. Due to the geometry, optimal detection is ensured regardless of its orientation when the applicator is tilted. It is possible to detect the presence of fluid well below the typical perturbing fluid depth established by the clinic (1-1.5 cm). CONCLUSIONS: The detector can distinguish the presence of around 0.5 cm of fluid depth while showing a high visual field through the PMMA applicators and providing a measure that does not depend on the detector orientation when the applicator is tilted. The prototype is ready for its industrialization by embedding it into the applicator for clinical use. The detector would have a significant impact on both the quality assurance and the outcome of the treatment.


Assuntos
Elétrons/uso terapêutico , Hemorragia/diagnóstico , Radioterapia , Hemorragia/etiologia , Período Intraoperatório , Aceleradores de Partículas
4.
Phys Med ; 57: 95-99, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-30738538

RESUMO

PURPOSE: The aim of this work is to develop a bleeding detector integrated into the acrylic circular applicators for specific mobile linacs. Thus, a bleeding detector has been developed based on a capacitive sensor to be used with plastic applicators, as in the case of LIAC HWL from Sordina IORT Technologies SpA. According to the clinical impact, we have selected 0.5 cm as the minimum depth of fluid that should be detected. METHODS: An experiment was developed using water-simulating blood. Two setups were considered: non-beveled applicators with 7 cm and 10 cm diameter. Measurements were done for applicators 0° and 45° tilted, both with respect to the horizontal surface, in order to mimic the worst clinical scenario according to the irradiation gantry and applicator bevel angle. The behavior of the detector under irradiation was analyzed and the impact of the stray radiation on the detector was also evaluated. RESULTS: The detector was able to distinguish the presence of liquid at a minimum height of 0.5 cm. A linear behavior was obtained for both setups. We have also verified that the LIAC HWL radiation does not affect the measurements nor does the detector interfere with the stray radiation. The bleeding detector is a quasi-digital capacitive sensor with low-cost, high linearity, and easy to install. CONCLUSIONS: With this detector it is possible to perform a continuous monitoring of the liquid measurements even during the irradiation phase. Thus, it can operate not only as a pre-treatment detector but also as a continuous one.


Assuntos
Elétrons , Hemorragia/diagnóstico , Aceleradores de Partículas , Lesões por Radiação/diagnóstico , Radioterapia/efeitos adversos , Período Intraoperatório
5.
Sensors (Basel) ; 16(12)2016 Dec 14.
Artigo em Inglês | MEDLINE | ID: mdl-27983652

RESUMO

Material resistance is important since different physicochemical properties can be extracted from it. This work describes a novel resistance measurement method valid for a wide range of resistance values up to 100 GΩ at a low powered, small sized, digitally controlled and wireless communicated device. The analog and digital circuits of the design are described, analysing the main error sources affecting the accuracy. Accuracy and extended uncertainty are obtained for a pattern decade box, showing a maximum of 1 % accuracy for temperatures below 30 ∘ C in the range from 1 MΩ to 100 GΩ. Thermal analysis showed stability up to 50 ∘ C for values below 10 GΩ and systematic deviations for higher values. Power supply V i applied to the measurement probes is also analysed, showing no differences in case of the pattern decade box, except for resistance values above 10 GΩ and temperatures above 35 ∘ C. To evaluate the circuit behaviour under fiber materials, an 11-day drying process in timber from four species (Oregon pine-Pseudotsuga menziesii, cedar-Cedrus atlantica, ash-Fraxinus excelsior, chestnut-Castanea sativa) was monitored. Results show that the circuit, as expected, provides different resistance values (they need individual conversion curves) for different species and the same ambient conditions. Additionally, it was found that, contrary to the decade box analysis, V i affects the resistance value due to material properties. In summary, the proposed circuit is able to accurately measure material resistance that can be further related to material properties.

SELEÇÃO DE REFERÊNCIAS