Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Eur Radiol ; 2024 Jan 06.
Artigo em Inglês | MEDLINE | ID: mdl-38183450

RESUMO

OBJECTIVES: Partial thrombosis of the false lumen (FL) in patients with chronic aortic dissection (AD) of the descending aorta has been associated with poor outcomes. Meanwhile, the fluid dynamic and biomechanical characteristics associated with partial thrombosis remain to be elucidated. This retrospective, single-center study tested the association between FL fluid dynamics and biomechanics and the presence and extent of FL thrombus. METHODS: Patients with chronic non-thrombosed or partially thrombosed FLs in the descending aorta after an aortic dissection underwent computed tomography angiography, cardiovascular magnetic resonance (CMR) angiography, and a 4D flow CMR study. A comprehensive quantitative analysis was performed to test the association between FL thrombus presence and extent (percentage of FL with thrombus) and FL anatomy (diameter, entry tear location and size), fluid dynamics (inflow, rotational flow, wall shear stress, kinetic energy, and flow acceleration and stasis), and biomechanics (pulse wave velocity). RESULTS: Sixty-eight patients were included. In multivariate logistic regression FL kinetic energy (p = 0.038) discriminated the 33 patients with partial FL thrombosis from the 35 patients with no thrombosis. Similarly, in separated multivariate linear correlations kinetic energy (p = 0.006) and FL inflow (p = 0.002) were independently related to the extent of the thrombus. FL vortexes, flow acceleration and stasis, wall shear stress, and pulse wave velocity showed limited associations with thrombus presence and extent. CONCLUSION: In patients with chronic descending aorta dissection, false lumen kinetic energy is related to the presence and extent of false lumen thrombus. CLINICAL RELEVANCE STATEMENT: In patients with chronic aortic dissection of the descending aorta, false lumen hemodynamic parameters are closely linked with the presence and extent of false lumen thrombosis, and these non-invasive measures might be important in patient management. KEY POINTS: • Partial false lumen thrombosis has been associated with aortic growth in patients with chronic descending aortic dissection; therefore, the identification of prothrombotic flow conditions is desirable. • The presence of partial false lumen thrombosis as well as its extent was related with false lumen kinetic energy. • The assessment of false lumen hemodynamics may be important in the management of patients with chronic aortic dissection of the descending aorta.

2.
JACC Cardiovasc Imaging ; 15(1): 46-56, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34801463

RESUMO

OBJECTIVES: This study sought to assess the predictive value of wall shear stress (WSS) for colocalized ascending aorta (AAo) growth rate (GR) in patients with bicuspid aortic valve (BAV). BACKGROUND: BAV is associated with AAo dilation, but there is limited knowledge about possible predictors of aortic dilation in patients with BAV. An increased WSS has been related to aortic wall damage in patients with BAV, but no previous prospective study tested its predictive value for dilation rate. Recently, a registration-based technique for the semiautomatic mapping of aortic GR has been presented and validated. METHODS: Forty-seven patients with BAV free from valvular dysfunction prospectively underwent 4-dimensional flow cardiac magnetic resonance to compute WSS and subsequent follow-up with 2 electrocardiogram-gated high-resolution contrast-enhanced computed tomography angiograms for GR assessment. RESULTS: During a median follow-up duration of 43 months, mid AAo GR was 0.24 mm/year. WSS and its circumferential component showed statistically significant association with mid AAo GR in bivariate (P = 0.049 and P = 0.014, respectively) and in multivariate analysis corrected for stroke volume and either baseline AAo diameter (P = 0.046 and P = 0.014, respectively) or z-score (P = 0.036 and P = 0.012, respectively). GR mapping further detailed that GR was heterogeneous in the AAo and that circumferential WSS, but not WSS magnitude, showed statistically significant positive associations with GR in the regions with the fastest growth. CONCLUSIONS: 4D flow cardiac magnetic resonance-derived WSS and, in particular, its circumferential component predict progressive dilation of the ascending aorta in patients with BAV. Thus, the assessment of WSS may be considered in the follow-up of these patients.


Assuntos
Doença da Válvula Aórtica Bicúspide , Doenças das Valvas Cardíacas , Valva Aórtica/diagnóstico por imagem , Dilatação , Hemodinâmica , Humanos , Valor Preditivo dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...