Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
2.
Circ Arrhythm Electrophysiol ; 17(2): e012473, 2024 02.
Artigo em Inglês | MEDLINE | ID: mdl-38284238

RESUMO

BACKGROUND: Right ventricular apical pacing (RVAP) can produce left ventricle dysfunction. Conduction system pacing (CSP) has been used successfully to reverse left ventricle dysfunction in patients with left bundle branch block. To date, data about CSP prevention of left ventricle dysfunction in patients with preserved left ventricular ejection fraction (LVEF) are scarce and limited mostly to nonrandomized studies. Our aim is to demonstrate that CSP can preserve normal ventricular function compared with RVAP in the setting of a high burden of ventricular pacing. METHODS: Consecutive patients with a high-degree atrioventricular block and preserved or mildly deteriorated LVEF (>40%) were included in this prospective, randomized, parallel, controlled study, comparing conventional RVAP versus CSP. RESULTS: Seventy-five patients were randomized, with no differences between basal characteristics in both groups. The stimulated QRS duration was significantly longer in the RVAP group compared with the CSP group (160.4±18.1 versus 124.2±20.2 ms; p<0.01). Seventy patients were included in the intention-to-treat analyses. LVEF showed a significant decrease in the RVAP group at 6 months compared with the CSP group (mean difference, -5.8% [95% CI, -9.6% to -2%]; P<0.01). Left ventricular end-diastolic diameter showed an increase in the RVAP group compared with the CSP group (mean difference, 3.2 [95% CI, 0.1-6.2] mm; P=0.04). Heart failure-related admissions were higher in the RVAP group (22.6% versus 5.1%; P=0.03). CONCLUSIONS: Conduction system stimulation prevents LVEF deterioration and heart failure-related admissions in patients with normal or mildly deteriorated LVEF requiring a high burden of ventricular pacing. These results are only short term and need to be confirmed by further larger studies. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: NCT06026683.


Assuntos
Terapia de Ressincronização Cardíaca , Cardiomiopatias , Insuficiência Cardíaca , Humanos , Volume Sistólico , Função Ventricular Esquerda/fisiologia , Ventrículos do Coração , Estudos Prospectivos , Estimulação Cardíaca Artificial/efeitos adversos , Estimulação Cardíaca Artificial/métodos , Doença do Sistema de Condução Cardíaco , Resultado do Tratamento
4.
J Clin Med ; 11(8)2022 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-35456193

RESUMO

Background: Pulmonary veins isolation (PVI) is a standard treatment for recurrent atrial fibrillation (AF). Uninterrupted anticoagulation for a minimum of 3 weeks before ablation and exclusion of left atrial (LA) thrombus with transesophageal echography (TEE) immediately before or during the procedure minimize peri-procedural risk. We aimed to demonstrate the utility of cardiac tomography (CT) and cardiac magnetic resonance (CMR) to rule out LA thrombus prior to PVI. Methods: Patients undergoing PVI for recurrent AF were retrospectively evaluated. Only patients that started anticoagulation at least 3 weeks prior to the CT/CMR and subsequently uninterrupted until the ablation procedure were selected. An intracardiac echo (ICE) catheter was used in all patients to evaluate LA thrombus. The results of CT/CMR were compared to ICE imaging. Results: We included 272 consecutive patients averaging 54.5 years (71% male; 30% persistent AF). Average CHA2DS2VASC score was 0.9 ± 0.83 and mean LA diameter was 42 ± 5.7 mm, 111 (41%) patients were on Acenocumarol and 161 (59%) were on direct oral anticoagulants. Anticoagulation was started 227 ± 392 days before the CT/CMR, and 291 ± 416 days before the ablation procedure. CT/CMR diagnosed intracardiac thrombus in two cases, both in the LA appendage. A new CT/CMR revealed resolution of thrombus after six additional months of uninterrupted anticoagulation. No macroscopic thrombus was observed in any patients with ICE (negative predictive value of 100%; p < 0.01). Conclusions: CT and MRI are excellent surrogates to TEE and ICE to rule out intracardiac thrombus in patients adequately anticoagulated prior AF ablation. This is true even for delayed procedures as long as anticoagulation is uninterrupted.

5.
J Interv Card Electrophysiol ; 63(3): 591-599, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-34595692

RESUMO

BACKGROUND: Catheter ablation of accessory pathways (AP) with bidirectional conduction may be challenging due to issues related to anatomical course or location. OBJECTIVE: We describe an alternative electro-anatomical mapping technique which aims at depicting the entire anatomic course of the AP from the atrial toward the ventricular insertion in order to guide catheter ablation. METHODS: Twenty consecutive patients with confirmed bidirectional AP conduction and at least one previous ablation procedure or para-Hisian location were included. 3-D electro-anatomical mapping was used to depict the merged 10-ms isochrone area of maximum early activation of both the ventricular and atrial signals during sinus rhythm and ventricular pacing/orthodromic tachycardia, respectively. Catheter ablation was performed within the depicted earliest isochrone area. RESULTS: Acute bidirectional AP conduction block was achieved in all patients 4.2 ± 1.7 s after the first radiofrequency energy pulse was delivered, without reconnection during a 30 ± 10 min post-ablation observation time. No procedural complications were seen. After a mean follow-up period of 9 ± 7 months (range 3 to 16), no recurrences were documented. CONCLUSION: This merged two-way mapping technique is a safe, efficient, and effective technique for ablation of APs with bidirectional conduction.


Assuntos
Feixe Acessório Atrioventricular , Ablação por Cateter , Feixe Acessório Atrioventricular/cirurgia , Ablação por Cateter/métodos , Eletrocardiografia , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/cirurgia , Frequência Cardíaca , Humanos
6.
J Cardiol ; 79(3): 417-422, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-34774385

RESUMO

PURPOSE: Patients undergoing cavotricuspid isthmus (CTI) ablation for typical flutter (AFL) have a high incidence of new onset atrial fibrillation (AF). We aimed to analyze the influence of PACE score to predict new onset AF in this subset of patients to stratify thromboembolic risk. METHODS: Between 2017 and 2019, patients undergoing CTI ablation for AFL and without history of AF were prospectively included. All patients were monitored continuously by implantable loop recorder and followed by remote monitoring. RESULTS: Overall 48 patients were included. New onset AF rate at 12 months was 56.3%. We observed two very strong independent predictors for new onset AF: a PACE score ≥ 30 (HR:6.9; 95% CI:1.71-27.91; p = 0.007) and an HV interval ≥ 55 (HR:11.86; 95% CI:2.57-54.8; p = 0.002). CONCLUSIONS: The incidence of newly diagnosed AF is high in patients with AFL after CTI ablation, and can occur early. A high PACE score and/or long HV interval predict even higher risk, and may be useful in the decision for empiric long-term anticoagulation.


Assuntos
Fibrilação Atrial , Flutter Atrial , Ablação por Cateter , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/etiologia , Fibrilação Atrial/cirurgia , Flutter Atrial/epidemiologia , Flutter Atrial/etiologia , Ablação por Cateter/efeitos adversos , Humanos , Incidência , Resultado do Tratamento
7.
Curr Cardiol Rep ; 23(3): 20, 2021 02 20.
Artigo em Inglês | MEDLINE | ID: mdl-33611699

RESUMO

PURPOSE OF REVIEW: Obstructive sleep apnea syndrome (OSAS) has a high prevalence in western countries. Many papers have been published with the purpose of demonstrating that OSAS acts as an arrhythmia trigger and is responsible for an increase in cardiovascular morbidity and mortality. The aim of this study was to review our knowledge on this topic. RECENT FINDINGS: There is a lot of evidence demonstrating the relationship between OSAS and arrhythmias, but there remains a lack of an interventional randomized trial to demonstrate that by treating OSAS we can reduce arrhythmia burden. OSAS is a highly prevalent illness in western countries and is clearly related to an increase in cardiovascular mortality and morbidity. Cardiac arrhythmias are triggered by a repetitive hypoxemia, hypercapnia, acidosis, intrathoracic pressure fluctuations, reoxygenation, and arousals during apnea and hypopnea episodes. Early diagnosis and treatment of these patients can reduce further cardiovascular morbidity and mortality.


Assuntos
Apneia Obstrutiva do Sono , Arritmias Cardíacas/etiologia , Humanos , Hipóxia , Prevalência , Apneia Obstrutiva do Sono/complicações
8.
Heart Rhythm ; 18(5): 793-800, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-32961334

RESUMO

BACKGROUND: Atrial arrhythmias (ie, intra-atrial reentrant tachycardia and atrial fibrillation) are a leading cause of morbidity and hospitalization in adults with congenital heart disease (CHD). Little is known about their effect on quality of life and other patient-reported outcomes (PROs) in adults with CHD. OBJECTIVE: The purpose of this study was to assess the impact of atrial arrhythmias on PROs in adults with CHD and explore geographic variations. METHODS: Associations between atrial arrhythmias and PROs were assessed in a cross-sectional study of adults with CHD from 15 countries spanning 5 continents. A propensity-based matching weight analysis was performed to compare quality of life, perceived health status, psychological distress, sense of coherence, and illness perception in patients with and those without atrial arrhythmias. RESULTS: A total of 4028 adults with CHD were enrolled, 707 (17.6%) of whom had atrial arrhythmias. After applying matching weights, patients with and those without atrial arrhythmias were comparable with regard to age (mean 40.1 vs 40.2 years), demographic variables (52.5% vs 52.2% women), and complexity of CHD (15.9% simple, 44.8% moderate, and 39.2% complex in both groups). Patients with atrial arrhythmias had significantly worse PRO scores with respect to quality of life, perceived health status, psychological distress (ie, depression), and illness perception. A summary score that combines all PRO measures was significantly lower in patients with atrial arrhythmias (-3.3%; P = .0006). Differences in PROs were consistent across geographic regions. CONCLUSION: Atrial arrhythmias in adults with CHD are associated with an adverse impact on a broad range of PROs consistently across various geographic regions.


Assuntos
Fibrilação Atrial/etiologia , Cardiopatias Congênitas/complicações , Medidas de Resultados Relatados pelo Paciente , Qualidade de Vida , Adulto , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/fisiopatologia , Estudos Transversais , Feminino , Saúde Global , Cardiopatias Congênitas/epidemiologia , Cardiopatias Congênitas/fisiopatologia , Humanos , Masculino , Morbidade/tendências
9.
Heart Rhythm ; 17(5 Pt A): 768-776, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-31790832

RESUMO

BACKGROUND: Implantable cardioverter-defibrillators (ICDs) are increasingly being used to prevent sudden death in the growing population of adults with congenital heart disease (CHD). However, little is known about their impact on patient-reported outcomes (PROs). OBJECTIVE: The purpose of this study was to assess and compare PROs in adults with CHD with and without ICDs. METHODS: A propensity-based matching weight analysis was conducted to evaluate PROs in an international cross-sectional study of adults with CHD from 15 countries across 5 continents. RESULTS: A total of 3188 patients were included: 107 with ICDs and 3081 weight-matched controls without ICDs. ICD recipients were an average age of 40.1 ± 12.4 years, and >95% had moderate or complex CHD. Defibrillators were implanted for primary and secondary prevention in 38.3% and 61.7%, respectively. Perceived health status, psychological distress, sense of coherence, and health behaviors did not differ significantly among patients with and without ICDs. However, ICD recipients had a more threatening view of their illness (relative % difference 8.56; P = .011). Those with secondary compared to primary prevention indications had a significantly lower quality-of-life score (Linear Analogue Scale 72.0 ± 23.1 vs 79.2 ± 13.0; P = .047). Marked geographic variations were observed. Overall sense of well-being, assessed by a summary score that combines various PROs, was significantly lower in ICD recipients (vs controls) from Switzerland, Argentina, Taiwan, and the United States. CONCLUSION: In an international cohort of adults with CHD, ICDs were associated with a more threatening illness perception, with a lower quality of life in those with secondary compared to primary prevention indications. However, marked geographic variability in PROs was observed.


Assuntos
Desfibriladores Implantáveis , Cardiopatias Congênitas , Adulto , Estudos Transversais , Morte Súbita Cardíaca/epidemiologia , Morte Súbita Cardíaca/etiologia , Morte Súbita Cardíaca/prevenção & controle , Cardiopatias Congênitas/complicações , Cardiopatias Congênitas/epidemiologia , Cardiopatias Congênitas/terapia , Humanos , Pessoa de Meia-Idade , Medidas de Resultados Relatados pelo Paciente , Qualidade de Vida , Estados Unidos/epidemiologia
10.
JACC Clin Electrophysiol ; 5(6): 671-680, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-31221353

RESUMO

OBJECTIVES: This study sought to assess the feasibility, safety, and outcomes of a stepwise combined percutaneous approach that includes transvenous lead extraction (TLE) followed by baffle stenting and device reimplantation in patients with D-transposition of the great arteries (D-TGA) and atrial baffle dysfunction. BACKGROUND: Management of baffle leak or stenosis in patients with D-TGA and atrial switch surgery is challenging in the presence of transvenous cardiac implantable electronic devices. Baffle complications hinder device-related interventions and addressing baffle dysfunction often requires TLE. METHODS: All consecutive patients with D-TGA and TLE followed by a percutaneous baffle intervention at the Montreal Heart Institute between 2009 and 2018 were enrolled. RESULTS: Ten patients, median 38.6 years of age (range 15.2 to 50.6 years), 5 males (50.0%) were included. Procedures were performed for a device-related indication in 5 patients (50.0%) and for baffle dysfunction in 5 patients (50.0%). A total of 19 leads (17 pacing, 2 defibrillation) were targeted, with a median time from implantation of 8.7 (range 4.3 to 22.1) years. A laser sheath was most frequently required for successful TLE, which was achieved in all patients. Immediate baffle stenting was performed in 9 patients (90.0%) and immediate device reimplantation in 6 (60.0%). During a median follow-up of 3.0 (range 0.1 to 8.2) years, the only complication was subpulmonary atrioventricular valve damage requiring surgery in 1 patient, 8 months after the procedure. CONCLUSIONS: A combined approach with TLE followed by baffle stenting and reimplantation appears to be safe and feasible in D-TGA patients with atrial switch, baffle dysfunction, and transvenous leads.


Assuntos
Transposição das Grandes Artérias , Remoção de Dispositivo/métodos , Eletrodos Implantados , Oclusão de Enxerto Vascular/cirurgia , Stents , Transposição dos Grandes Vasos/cirurgia , Adolescente , Adulto , Dispositivos de Terapia de Ressincronização Cardíaca , Desfibriladores Implantáveis , Estudos de Viabilidade , Feminino , Oclusão de Enxerto Vascular/complicações , Humanos , Masculino , Pessoa de Meia-Idade , Marca-Passo Artificial , Implantação de Prótese , Transposição dos Grandes Vasos/complicações , Adulto Jovem
11.
Europace ; 21(4): 645-654, 2019 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-30624715

RESUMO

AIMS: The decision to abandon or extract superfluous leads remains controversial. We sought to compare procedural outcome of patients with and without abandoned leads undergoing transvenous lead extraction (TLE). METHODS AND RESULTS: An analysis of the ESC-EHRA European Lead Extraction ConTRolled ELECTRa registry was conducted. Patients were stratified into two groups based on the presence (Group 1) or absence (Group 2) of abandoned leads at the time for extraction. Out of 3508 TLE procedures, 422 patients (12.0%) had abandoned leads (Group 1). Group 1 patients were older and more likely to have implantable cardioverter-defibrillator devices, infection indication (78.8% vs. 49.8%), and vegetations (24.6% vs. 15.3%). Oldest lead dwelling time was longer in Group 1 (10.9 vs. 6.3 years) as was the number of extracted leads per patient (3.2 vs. 1.7). Manual traction failure (94.5% vs. 78.8%), powered sheath use (50.7% vs. 28.4%), and femoral approach were higher in Group 1 (P < 0.0001). Procedural success rate and clinical success (89.8% vs. 96.6%, P < 0.0001) were lower in Group 1. Major complication including deaths (5.5% vs. 2.3%, P = 0.0007) and procedure related major complications (3.3% vs. 1.4%, P = 0.0123) were higher in Group 1. The presence of abandoned leads at the time of TLE was an independent predictor of clinical failure [odds ratio (OR) 2.31, confidence interval (CI) 1.57-3.40] and complications [OR 1.69, CI 1.22-2.35]. receiver-operating characteristic curve analysis showed a dwell time threshold of 9 years for radiological failure and major complications. CONCLUSIONS: Previously abandoned leads at the time of TLE were associated with increased procedural complexity, clinical failure, and major complication, which may have important implications for future studies regarding managing of lead failures.


Assuntos
Remoção de Dispositivo/métodos , Falha de Equipamento , Marca-Passo Artificial , Complicações Pós-Operatórias/epidemiologia , Infecções Relacionadas à Prótese/cirurgia , Idoso , Cateterismo Cardíaco/métodos , Dispositivos de Terapia de Ressincronização Cardíaca/efeitos adversos , Desfibriladores Implantáveis , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino , Recall de Dispositivo Médico , Pessoa de Meia-Idade , Marca-Passo Artificial/efeitos adversos , Curva ROC , Sistema de Registros , Fatores de Tempo , Trombose Venosa/etiologia , Trombose Venosa/cirurgia
13.
Heart ; 100(4): 324-35, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23878175

RESUMO

BACKGROUND: Dabigatran etexilate, a new thrombin inhibitor, has been shown to be comparable to warfarin in patients with atrial fibrillation (AF). However, there is a limited body of evidence on the efficacy and safety of using dabigatran among patients undergoing AF catheter ablation. OBJECTIVE: A random effects meta-analysis was performed of controlled trials comparing dabigatran and warfarin in paroxysmal/persistent AF patients undergoing catheter ablation. METHODS: Data sources included Medline, Embase, and Cochrane (from inception to April 2013). Three independent reviewers selected studies comparing warfarin to dabigatran. Descriptive and quantitative information was extracted from each selected study, regarding periprocedural all cause mortality, thromboembolic events and major bleeding, as well as modalities of periprocedural anticoagulation bridging. RESULTS: After a detailed screening of 228 search results, 14 studies were identified enrolling a total of 4782 patients (1823 treated with dabigatran and 2959 with warfarin). No deaths were reported. No significant differences were found between patients treated with dabigatran and warfarin as regards thromboembolic events (0.55% dabigatran vs 0.17% warfarin; risk ratios (RR)=1.78, 95% CI 0.66 to 4.80; p=0.26) and major bleeding (1.48% dabigatran vs 1.35% warfarin; RR=1.07, 95% CI 0.51 to 2.26; p=0.86). No difference was found between the 110 mg twice daily and 150 mg twice daily dabigatran dosages concerning major bleeding (0% vs 1.62%, respectively; RR=0.19, 95% CI 0.01 to 3.18; p=0.25) and thromboembolism (0% vs 0.40%, respectively; RR=0.72, 95% CI 0.04 to 12.98; p=0.82). CONCLUSIONS: In the specific setting of AF catheter ablation, this first pooled analysis suggests that patients treated with dabigatran have a similar incidence of thromboembolic events and major bleeding compared to warfarin, with low event rates overall.


Assuntos
Fibrilação Atrial/cirurgia , Benzimidazóis/uso terapêutico , Ablação por Cateter , Cuidados Pré-Operatórios/métodos , Tromboembolia/prevenção & controle , Varfarina/uso terapêutico , beta-Alanina/análogos & derivados , Anticoagulantes/uso terapêutico , Antitrombinas/uso terapêutico , Fibrilação Atrial/complicações , Dabigatrana , Humanos , Tromboembolia/etiologia , Resultado do Tratamento , beta-Alanina/uso terapêutico
14.
Europace ; 16(6): 826-33, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24351882

RESUMO

AIM: Real-time assessment of pulmonary vein (PV) disconnection is possible using an inner circular mapping catheter during cryoablation of atrial fibrillation (AF). However, it has been recently demonstrated that such continuous monitoring may only be possible in <50% of PVs. We hypothesized that a stepwise mapping approach, including pacing manoeuvres, could optimize monitoring of real-time PV disconnection during ablation. METHODS AND RESULTS: Single-centre, prospective observational study (NCT01843465) including 34 consecutive eligible patients (128 PVs) undergoing a first procedure of cryoballoon ablation of AF using the Artic Front Advance(®) 28 mm catheter and a 20 mm diameter Achieve(®) catheter (AC) in all cases. Monitoring of real-time entrance block was possible, when AC was maintained in the standard position (distal to the tip of the Artic Front Advance(®) catheter) in 47 (36.7%) PVs. In an additional 63 cases (49.2%), such monitoring was possible after moving AC to a more proximal position and using different torqueing movements. Finally, using supplemental systematic pacing manoeuvres to test exit block, real-time assessment of PV disconnection was possible in 15 (11.7%) more PVs. Overall, real-time assessment of PV disconnection was possible in 97.7% of cases, after a mean duration of 48.6 ± 33.0 s. CONCLUSION: Our results suggest that optimal use of the AC, with a systematic stepwise mapping approach, may dramatically improve the real-time monitoring of PV disconnection during AF cryoablation.


Assuntos
Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Mapeamento Potencial de Superfície Corporal/métodos , Criocirurgia/métodos , Sistema de Condução Cardíaco/cirurgia , Veias Pulmonares/cirurgia , Cirurgia Assistida por Computador/métodos , Sistemas Computacionais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...