Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Environ Radioact ; 247: 106868, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35305306

RESUMO

The Metropolitan Region of Recife and its surroundings are heavily exploited to capture water for public supply through tubular wells. However, a survey of the levels of natural radionuclides from these sources had never been carried out, even though part of this region contains a phosphate deposit that has a high concentration of natural uranium. In this context, this research aimed to identify 228Ra and 226Ra levels in groundwater in the coastal region of Pernambuco, Brazil. About 110 points (wells) of drinking water for public supply were identified and studies were carried out to estimate the level of ingestion and subsequent risk due to the presence of this radionuclide. The average concentration of combined radium was 104 mBq.L-1. For 228Ra an effective dose of 0.46, 0.11, 0.12 and 0.0276 mSv.y-1 for infants, children aged 1 and 10 and adults, respectively, were obtained. Although doses above those recommended by WHO were found, the equivalent dose and the induction of bone sarcoma did not indicate a risk to the population. Groundwater with higher dose values is influenced by local geology.


Assuntos
Água Subterrânea , Monitoramento de Radiação , Rádio (Elemento) , Urânio , Poluentes Radioativos da Água , Adulto , Criança , Pré-Escolar , Cidades , Humanos , Lactente , Rádio (Elemento)/análise , Urânio/análise , Poluentes Radioativos da Água/análise , Abastecimento de Água
2.
Appl Radiat Isot ; 178: 109948, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34536831

RESUMO

Radon is important in indoor radiometry, where radiological impact is relevant. The improvement of low-cost methods makes it possible to maximize the monitored areas. Thus, a simple and robust monitoring device based on SSNTD CR-39 was designed. Detector conditions were standardized to reduce operational errors and increase productivity. The calibration factor by the slope method allowed efficiency greater than 93%. The monitoring system is satisfactory in terms of operation and performance, suitable for a wide range of radon monitoring situations.


Assuntos
Desenho de Equipamento , Monitoramento de Radiação/instrumentação , Radônio/análise , Calibragem , Difusão , Limite de Detecção , Reprodutibilidade dos Testes
3.
Radiat Prot Dosimetry ; 187(3): 310-320, 2019 Dec 31.
Artigo em Inglês | MEDLINE | ID: mdl-31268527

RESUMO

The radiometric monitoring carried out in the present study allowed the discovery of anomalous granite outcrops in natural radionuclides in the rural area of São Mamede in the state of Paraíba, Brazil. The characterisation study made it possible to determine maximum specific concentrations of approximately 199 kBq kg-1 of 238U, 85 kBq kg-1 of 226Ra, 26 kBq kg-1 of 232Th and 24 kBq kg-1 of 40K. Models for environmental dosimetry were applied, which resulted in obtaining the following quantities: radium equivalent (Raeq), indices of external (Hex), internal (Hin) and representative (Iyr) damage, and the effective outdoor dose (HE). The maximum results presented were approximately 123 kBq kg-1, 332, 562, 832, and 68 mSv y-1, respectively. Consequently, it was possible to define the region as of high radioactive background due to isolated rocky outcrops located in the rural area of the mentioned municipality.


Assuntos
Radiação de Fundo , Radioisótopos de Potássio/análise , Monitoramento de Radiação/métodos , Rádio (Elemento)/análise , Poluentes Radioativos do Solo/análise , Tório/análise , Urânio/análise , Brasil
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...