Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Arch Orthop Trauma Surg ; 144(6): 2665-2671, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38801533

RESUMO

INTRODUCTION: Open book injuries are challenging injuries that oftentimes require surgical treatment. Currently, treatment is performed with symphyseal plating requiring extensive surgery and entirely limiting physiological movement of the symphyseal joint, frequently resulting in implant failure. Therefore, we investigated the biomechanical properties of a minimally invasive tape suture construct (modified SpeedBridge™) as an alternative stabilization technique for the treatment of open book injuries in human cadaver pelvic rings. MATERIALS AND METHODS: The symphysis of 9 human cadaver pelvises was dissected and dilated to 3 cm creating an open book injury. Next, the two osteosynthesis methods (plating, modified SpeedBridge™) were applied. All specimens then underwent cyclic horizontal and vertical loading, simulating biomechanical forces while sitting, standing and walking. For statistical analysis, 3D dislocation (mm) was calculated. RESULTS: Total displacement (mm) of the pubic symphysis displayed the following means and standard deviations: native group 1.34 ± 0.62 mm, open book group 3.01 ± 1.26 mm, tape group 1.94 ± 0.59 mm and plate group 1.37 ± 0.41 mm. Comparison between native and open book (p = 0.029), open book and plate (p = 0.004), open book and tape (p = 0.031), as well as tape and plate group (p = 0.002) showed significant differences. No significant differences were found when comparing the native and tape (p = 0.059), as well as the native and plate (p = 0.999) group. CONCLUSION: While both osteosynthesis techniques sufficiently stabilized the injury, symphyseal plating displayed the highest rigidity. The modified SpeedBridge™ as a tape suture construct provided statistically sufficient biomechanical stability while maintaining symphyseal micro mobility, consequently allowing ligamental healing of the injured joint without iatrogenic arthrodesis.


Assuntos
Cadáver , Sínfise Pubiana , Humanos , Sínfise Pubiana/lesões , Sínfise Pubiana/cirurgia , Fenômenos Biomecânicos , Fixação Interna de Fraturas/métodos , Fixação Interna de Fraturas/instrumentação , Masculino , Placas Ósseas , Feminino , Fraturas Ósseas/cirurgia
2.
Dtsch Arztebl Int ; 120(50): 855-862, 2023 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-37963039

RESUMO

BACKGROUND: Fractures of the fingers and metacarpal bones are the most common fracture type in the upper limb, with an incidence of 114 to 1483 per 100 000 persons per year. The clinical importance of closed finger and metacarpal fractures is often underestimated; inadequate diagnostic and therapeutic measures may result in serious harm. This review concerns the basic elements of the diagnosis and treatment of finger and metacarpal fractures. METHODS: This review of the incidence, diagnosis and treatment of finger and metacarpal fractures is based on pertinent publications retrieved by a selective search of the literature. RESULTS: The main focus of treatment lies on restoration of hand function in consideration of the requirements of the individual patient. The currently available evidence provides little guidance to optimal treatment (level II evidence). Although most closed fractures can be managed conservatively, individualized surgical treatment is advisable in comminuted fractures and fractures with a relevant degree of torsional malposition, axis deviation, or shortening, as well as in intra-articular fractures. Minimally invasive techniques are, in principle, to be performed wherever possible, yet open surgery is sometimes needed because of fracture morphology. Postsurgical complication rates are in the range of 32-36%, with joint fusion accounting for 67-76% of the complications. 15% involve delayed fracture healing and pseudarthrosis. CONCLUSION: Individualized treatment for finger and metacarpal fractures can improve patients' outcomes, with major socioeconomic and societal benefits. Further high-quality studies evaluating the relative merits of the available treatments are needed as a guide to optimized therapy.


Assuntos
Fraturas Ósseas , Traumatismos da Mão , Ossos Metacarpais , Humanos , Ossos Metacarpais/diagnóstico por imagem , Ossos Metacarpais/cirurgia , Ossos Metacarpais/lesões , Fraturas Ósseas/epidemiologia , Fraturas Ósseas/terapia , Fixação Interna de Fraturas/métodos , Extremidade Superior , Resultado do Tratamento
3.
J Clin Med ; 12(16)2023 Aug 10.
Artigo em Inglês | MEDLINE | ID: mdl-37629241

RESUMO

The incidence of fragility fractures of the pelvis (FFPs) is currently rising. Surgical treatment, which is performed using sacroiliac screws, is complicated by compromised bone quality, oftentimes resulting in implant failure. The iFuse implant system aims to improve attachment and durability with promising results for sacroiliac dysfunction, though data for its feasibility on FFPs are rare. Consequently, this study aims to evaluate the feasibility of the iFuse for FFPs. A total of 10 patients with FFPs were treated with the iFuse in this study. Pre- and postoperatively, both mobility using an established insole force sensor for an inpatient gait analysis and general well-being and pain using questionnaires were evaluated. When comparing pre- and postoperative findings, this study demonstrated a significant increase in the average (8.14%) and maximum (9.4%) loading (p < 0.001), a reduction in pain, as measured by the visual analog scale (VAS), from 4.60 to 2.80 at rest (p = 0.011) and from 7.00 to 4.40 during movement (p = 0.008), an increase in the Barthel Index by 20 points (p < 0.001) and an increase in the Parker Mobility Score by 2.00 points (p = 0.011). All this contributes to the possibility of early postoperative mobilization and improved general well-being, ultimately preventing the late consequences of postoperative immobilization and maintaining patients autonomy and contentment.

4.
Arch Orthop Trauma Surg ; 143(6): 3111-3117, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35831608

RESUMO

INTRODUCTION: Current gold standard for the treatment of symphyseal disruptions includes anterior plating, almost entirely prohibiting symphyseal mobility and resulting in an iatrogenic arthrodesis followed by high rates of implant failure. Minimally invasive tape suture constructs have been found to maintain the micro mobility of ligamentous injuries, yet still providing sufficient biomechanical stability. Recently, this technique has been primarily investigated for symphyseal disruptions on synthetic pelvic models. Therefore, the aim of this study was to examine the feasibility of this novel flexible osteosynthesis on cadaveric pelvic models based on the following hypothesis: tape suture constructs ensure sufficient biomechanical stability without inhibiting micro mobility of the pubic symphysis for the treatment of symphyseal disruptions and maintain stability during long-term loading. MATERIALS AND METHODS: 9 cadaveric anterior pelvic rings were used in this study and a symphyseal disruption was created in every specimen. The specimens were then exposed to short- and long-term vertical and horizontal cyclic loading after treatment with a tape suture construct in criss-cross technique. The mean maximum displacement (mm) during cyclic loading and the corresponding stiffness (N/mm) were measured and compared. RESULTS: Regarding both displacement (mm) and corresponding stiffness (N/mm), the tape sutures displayed a significant difference between short- and long-term loading for cranial and caudal vertical loading (p < 0.01) but differences remained non-significant for horizontal loading (p > 0.05). No tape suture suffered from implant failure during long-term loading. CONCLUSIONS: The tape suture construct displayed sufficient biomechanical stability without exceeding the physiological mobility of 2 mm of the pubic symphysis; however, also maintained the desired micro mobility of the affected joint necessary to prevent an iatrogenic arthrodesis. Further, all tape sutures maintained stability throughout long-term loading.


Assuntos
Sínfise Pubiana , Humanos , Sínfise Pubiana/cirurgia , Sínfise Pubiana/lesões , Fenômenos Biomecânicos , Cadáver , Suturas , Doença Iatrogênica , Técnicas de Sutura
5.
Eur J Orthop Surg Traumatol ; 33(6): 2497-2503, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-36544078

RESUMO

PURPOSE: The incidence of atlanto-axial injuries is continuously increasing and often requires surgical treatment. Recently, Harati developed a new procedure combining polyaxial transarticular screws with polyaxial atlas massae lateralis screws via a rod system with promising clinical results, yet biomechanical data is lacking. This biomechanical study consequently aims to evaluate the properties of the Harati technique. METHODS: Two groups, each consisting of 7 cervical vertebral segments (C1/2), were formed and provided with a dens axis type 2 fracture according to Alonzo. One group was treated with the Harms and the other with the Harati technique. The specimen was loaded via a lever arm to simulate extension, flexion, lateral flexion and rotation. For statistical analysis, dislocation (°) was measured and compared. RESULTS: For extension and flexion, the Harati technique displayed a mean dislocation of 4.12° ± 2.36° and the Harms technique of 8.48° ± 1.49° (p < 0.01). For lateral flexion, the dislocation was 0.57° ± 0.30° for the Harati and 1.19° ± 0.25° for the Harms group (p < 0.01). The mean dislocation for rotation was 1.09° ± 0.48° for the Harati and 2.10° ± 0.31° for the Harms group (p < 0.01). No implant failure occurred. CONCLUSION: This study found a significant increase in biomechanical stability of the Harati technique when compared to the technique by Harms et al. Consequently, this novel technique can be regarded as a promising alternative for the treatment of atlanto-axial instabilities.


Assuntos
Articulação Atlantoaxial , Instabilidade Articular , Fusão Vertebral , Humanos , Fusão Vertebral/métodos , Vértebras Cervicais/cirurgia , Articulação Atlantoaxial/cirurgia , Amplitude de Movimento Articular , Fenômenos Biomecânicos , Instabilidade Articular/etiologia , Instabilidade Articular/cirurgia
6.
Artigo em Inglês | MEDLINE | ID: mdl-35879618

RESUMO

PURPOSE: Three-dimensional (3D) printed patient-specific instruments (PSI) have been introduced to increase precision and simplify surgical procedures. Initial results in femoral and tibial osteotomies are promising, but validation studies on 3D planning, manufacturing of patient-specific cutting blocks and 3D evaluation of the attained results are lacking. METHODS: In this study, patient-specific cutting blocks and spacers were designed, fabricated, and used to perform a high tibial osteotomy (HTO). After segmentation of CT data sets from 13 human tibiae, 3D digital planning of the HTO was performed with a medial opening of 8 mm. These 3D models were used to fabricate patient-specific cutting blocks and spacers. After the surgical procedure, accuracy was evaluated measuring 3D joint angles and surface deviations. RESULTS: The lowest mean deviation was found to be 0.57° (SD ± 0.27) for the MPTA. Medial and lateral tibial slope deviated from the 3D planning by an average of 0.98° (SD ± 0.53) and 1.26° (SD ± 0.79), respectively, while tibial torsion deviated by an average of 5.74° (SD ± 3.24). Color analysis of surface deviations showed excellent and good agreement in 7 tibiae. CONCLUSION: With 3D cutting blocks and spacers, the 3D planning of the HTO can be translated into reality with small deviations of the resulting joint angles. Within this study, the results of the individual steps are examined for errors and thus a critical evaluation of this new and promising method for performing patient-specific HTOs is presented.

7.
Eur J Trauma Emerg Surg ; 48(5): 4215-4221, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35364692

RESUMO

PURPOSE: Open reduction and internal fixation using anterior plate osteosynthesis currently represents the gold standard for the treatment of symphyseal disruptions. Since postoperative screw loosening with consequent implant failure is frequently observed, this study aims to evaluate if and to what extent augmentation can increase the pull-out force of symphyseal screws to improve the constructs stability. METHODS: Twelve human cadaveric anterior pelvic rings were separated at the symphyseal joint for bilateral testing, consequently achieving comparable sites. First, one non-augmented screw was drilled into the superior pubic ramus, whereas the contralateral side was primarily augmented. The screws were then withdrawn with a constant speed of 10 mm/min and the fixation strengths determined by the force (N) displacement (mm) curve. Finally, the primary non-augmented site was secondary augmented, representing revision surgery after initial implant failure, and the corresponding fixation strength was measured again. RESULTS: Augmentation compared to non-augmented screws displayed significantly higher pull-out forces with an increase in pull-out force by 377% for primary and 353% for secondary augmentation (p < 0.01). There was no significant difference in the pull-out force comparing primary and secondary augmentation (p = 0.74). CONCLUSIONS: Primary and secondary augmentation significantly increases the stability of symphyseal screws and, therefore, potentially decreases rates of implant failure.


Assuntos
Cimentos Ósseos , Parafusos Ósseos , Fenômenos Biomecânicos , Cadáver , Fixação Interna de Fraturas , Humanos
8.
Arch Orthop Trauma Surg ; 142(9): 2235-2243, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34052913

RESUMO

INTRODUCTION: Open book fractures are challenging injuries oftentimes requiring surgical treatment. The current treatment of choice is symphyseal plating, which requires extensive surgery and entirely limits physiological movement of the symphyseal joint, frequently resulting in implant failure. Therefore, we investigated the biomechanical properties of a semi-rigid implant (modified SpeedBridge™) as a minimally invasive tape suture construct for the treatment of open book fractures and evaluated the superiority of two techniques of implementation: criss-cross vs. triangle technique. MATERIALS AND METHODS: Nine synthetic symphyseal joints were dissected creating an open book fracture. The different osteosynthesis methods (plating, modified SpeedBridge™ in criss-cross/triangle technique) were then applied. All constructs underwent horizontal and vertical loading, simulating biomechanical forces while sitting, standing and walking. For statistical analysis, dislocation (mm) and stiffness (N/mm) were calculated. RESULTS: Symphyseal plating for the treatment of open book fractures proved to be a rigid osteosynthesis significantly limiting the physiological mobility of the symphyseal joint (dislocation: 0.08 ± 0.01 mm) compared to the tape sutures (dislocation: triangle technique 0.27 ± 0.07 mm, criss-cross technique 0.23 ± 0.05 mm) regarding horizontal tension (p < 0.01). Both modified SpeedBridge™ techniques showed sufficient biomechanical stability without one being superior to the other (p > 0.05 in all directions). Considering vertical loading, no statistical difference was found between all osteosynthesis methods (caudal: p = 0.41; cranial: p = 0.61). CONCLUSIONS: Symphyseal plating proved to be the osteosynthesis method with the highest rigidity. The modified SpeedBridge™ as a semi-rigid suture construct provided statistically sufficient biomechanical stability while maintaining a minimum of symphyseal movement, consequently allowing ligamental healing of the injured joint without iatrogenic arthrodesis. Furthermore, both the criss-cross and the triangle technique displayed significant biomechanical stability without one method being superior.


Assuntos
Fraturas Ósseas , Sínfise Pubiana , Fenômenos Biomecânicos , Placas Ósseas , Parafusos Ósseos , Fixação Interna de Fraturas/métodos , Fraturas Ósseas/cirurgia , Humanos , Sínfise Pubiana/lesões , Suturas
9.
Eur J Trauma Emerg Surg ; 48(4): 3101-3108, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34881391

RESUMO

PURPOSE: Osteoporotic bone tissue appears to be an important risk factor for implant loosening, compromising the stability of surgical implants. However, it is unclear whether lumbar measured bone mineral density (BMD) is of any predictive value for stability of surgical implants at the pubic symphysis. This study examines the fixation strength of cortical screws in human cadaver specimens with different BMDs. METHODS: The lumbar BMD of ten human specimens was measured using quantitative computed tomography (qCT). A cut-off BMD was set at 120 mg Ca-Ha/mL, dividing the specimens into two groups. One cortical screw was drilled into each superior pubic ramus. The screw was withdrawn in an axial direction with a steady speed and considered failed when a force decrease was detected. Required force (N) and pull-out distance (mm) were constantly tracked. RESULTS: The median peak force of group 1 was 231.88 N and 228.08 N in group 2. While BMD values differed significantly (p < 0.01), a comparison of peak forces between both groups showed no significant difference (p = 0.481). CONCLUSION: Higher lumbar BMD did not result in significantly higher pull-out forces at the symphysis. The high proportion of cortical bone near the symphyseal joint allows an increased contact of pubic screws and could explain sufficient fixation. This condition is not reflected by a compromised lumbar BMD in a qCT scan. Therefore, site-specific BMD measurement could improve individual fracture management.


Assuntos
Densidade Óssea , Fraturas Ósseas , Fenômenos Biomecânicos , Parafusos Ósseos , Cadáver , Fraturas Ósseas/cirurgia , Humanos , Vértebras Lombares/diagnóstico por imagem , Vértebras Lombares/cirurgia
10.
Orthop Traumatol Surg Res ; 107(1): 102745, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33333281

RESUMO

BACKGROUND: Elderly patients suffering from hip fractures are usually not able to fulfil postoperative weight-bearing restrictions. Therefore, the operative fixation construct has to be as stable as possible. Aim of the present study was to determine (1) whether a therapeutic advantage could be achieved when using hip arthroplasty to treat acetabular fractures in geriatric patients; (2) whether an acetabular revision cup would be suitable for achieving fast postoperative mobilization and full weight-bearing; and (3) when a treatment with an uncemented hip revision cup for the primary fixation of osteoporotic acetabular fractures in geriatric patients is indicated. MATERIALS AND METHODS: The functional outcome of THA using a reconstruction cup for an acetabular fracture was evaluated in ten patients using standardized scoring instruments. In addition, an analysis of the preexisting literature referring to total hip replacement in geriatric acetabular fractures was conducted and an algorithm for standardizing the treatment approach for geriatric patients with acetabular fractures was developed. RESULTS: The mean EQ-5D-3L quality of life score 0.7. The mean VAS Score was 58.2. The average Barthel Index was 80.0 points [range: 0-100]. The mean HHS was 72.0 points, while the MHH Score yielded an average of 63.4 points. The average AP Score was 7.5. The literature analysis showed that total hip arthroplasty could be a feasible option for geriatric acetabular fractures. CONCLUSION: Primary hip arthroplasty using uncemented revision cup fixed with angular stable screws showed good results and is a feasible treatment option of acetabular fractures in geriatric patients. The approach is especially beneficial in patients with poor bone stock and allows postoperative full weight-bearing. The presented treatment algorithm could be a useful tool for identifying the most appropriate treatment option. LEVEL OF EVIDENCE: IIb.


Assuntos
Artroplastia de Quadril , Fraturas do Quadril , Prótese de Quadril , Acetábulo/diagnóstico por imagem , Acetábulo/cirurgia , Idoso , Fraturas do Quadril/diagnóstico por imagem , Fraturas do Quadril/cirurgia , Humanos , Falha de Prótese , Qualidade de Vida , Reoperação
11.
Injury ; 52(10): 2707-2711, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32033807

RESUMO

BACKGROUND: Percutaneous sacroiliac (SI) screw fixation is the standard operative treatment of traumatic disruptions to the posterior pelvic ring. The technique offers good outcomes and early postoperative mobilization, which is vital in elderly patients with fragility fractures of the pelvis. While a double-screw technique has been shown to provide optimal biomechanical stability compared to a single-screw construct, anatomic variations and patient-specific characteristics may prevent the safe insertion of two SI screws. We aimed to determine whether cement augmentation of a single SI screw would provide biomechanical stability comparable to that of the double-screw technique. METHODS: Three sacroiliac screw osteosynthesis configurations were tested on 10 human cadaveric pelvis specimens: a single cannulated screw; two cannulated screws; and a single, cement-augmented cannulated screw. Displacement and stiffness of the anterior and posterior pelvic ring after fixation with each technique were measured under axial load. Results where compared using linear regression and paired t-tests. RESULTS: A single uncemented screw offered significantly worse stability in the anterior pelvis compared to a double-screw technique (P < 0.05) and to a single cement-augmented screw technique (P < 0.05). There was no significant difference in anterior pelvic ring stability between the single cement-augmented screw technique and the double-screw technique (P > 0.05). There was no significant difference in the stability of the posterior pelvic ring between the three techniques (P > 0.05). CONCLUSIONS: A single cement-augmented cannulated sacroiliac screw provides biomechanical stability similar to that of a non-augmented double-screw technique in the treatment of posterior pelvic ring fractures.


Assuntos
Parafusos Ósseos , Ossos Pélvicos , Idoso , Fenômenos Biomecânicos , Cimentos Ósseos , Fixação Interna de Fraturas , Humanos , Ossos Pélvicos/cirurgia
12.
Eur J Med Res ; 25(1): 26, 2020 Jul 18.
Artigo em Inglês | MEDLINE | ID: mdl-32682448

RESUMO

INTRODUCTION: Unstable fractures of the pelvis remain the predominant cause of severe hemorrhage, shock and early death in severely injured patients. The use of pelvic binders has become increasingly popular, particularly in the preclinical setting. There is currently insufficient evidence available about the stability of the pelvic binder versus supraacetabular fixation using 1 or 2 Schanz screws. We aimed to analyze the stability of the pelvic binder and supraacetabular fixateurs using either 1 or 2 Schanz screws in a cadaver model of an induced pelvic B-type fracture. MATERIALS AND METHODS: The study was undertaken in 7 human fresh-frozen cadaveric pelvises with induced AO-type B fractures. Three stabilization techniques were compared: T-POD (pelvic bandage), supraacetabular external fixator with 1 pin on each side and external fixator with 2 pins on each side. Stability and stiffness were analyzed in a biomechanical testing machine using a 5-step protocol with static and dynamic loading, dislocation data were retrieved by ultrasound sensors at the fracture sites. RESULTS: No significant differences in fracture fragment displacement were detected when using either the T-POD, a 1-pin external fixator or a 2-pin external fixator (P > 0.05). The average difference in displacement between the three methods was < 1 mm. CONCLUSIONS: Pelvic binders are suitable for reduction of pelvic B-type fractures. They provide stability comparable to that of supraacetabular fixators, independently of whether 1 or 2 Schanz screws per side are used. Pelvic binders provide sufficient biomechanical stability for transferring patients without the need to first replace them with surgically applied external fixators. However, soft tissue irritation has to be taken into consideration and prolonged wear should be avoided. LEVEL OF EVIDENCE: Level III.


Assuntos
Parafusos Ósseos , Fixadores Externos , Fixação de Fratura/instrumentação , Fixação de Fratura/métodos , Fraturas Ósseas/cirurgia , Ossos Pélvicos/lesões , Ossos Pélvicos/cirurgia , Acetábulo/lesões , Acetábulo/cirurgia , Adulto , Idoso , Fenômenos Biomecânicos , Feminino , Seguimentos , Fraturas Ósseas/patologia , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Estudos Retrospectivos
13.
Orthop Traumatol Surg Res ; 106(1): 127-133, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31864961

RESUMO

BACKGROUND: The definite treatment of pelvic C fractures presents a widely discussed issue and undergoes continuous evolution. While the stabilization of the posterior ring has been studied extensively, the fixation of the anterior pelvic ring continuous to be rarely investigated. The importance of the simultaneous stabilization however lays in the earlier mobilization and prevention of long-term damage to the pelvis. Therefore we investigated four combinations of minimally invasive fixation techniques for unstable type C1-3 pelvic injuries and aimed to answer the following research questions: (1) what combination of fixation methods yields the highest stiffness and the least displacement? (2) Is the combination of a single sacroiliac screw (SI-screw) with a transiliac internal fixator (TIFI) a reasonable alternative to two SI-screws? (3) Is a modified unilateral anterior fixation comparable to a retrograde transpubic screw? HYPOTHESIS: Minimally invasive fixation techniques provide sufficient biomechanical stability for type C pelvic fractures. METHODS: Thirty synthetic full pelvises were divided into 5 groups, of which 4 groups were assigned a different osteosynthesis method and one was an intact pelvis used as reference (group 1: internal fixator+2 sacroiliac screws, group 2: internal fixator+transiliac internal fixator+1 sacroiliac screw, group 3: retrograde transpubic screw+2 sacroiliac screws, group 4: retrograde transpubic screw+transiliac internal fixator+1 sacroiliac screw). The pelvises underwent a protocol of cyclic loading between 100N and 200N, during which they were subjected to compression loads while the position of the fracture fragments was measured every 30 milliseconds. Displacement and stiffness were calculated for statistical analysis. RESULTS: The minimally invasive fixation methods investigated in this study all provide sufficient biomechanical stability without one method being superior to the others (p [anterior displacement]=0.61 and p [posterior displacement]=0.88). Group 3 was allowed the least displacement (1.8±0.2mm for anterior and posterior fracture) for the treatment of a C1.3 fracture. The other fixation methods displayed the following dislocations (mm) of the anterior pelvic ring: group 1: 1.9±0.3, group 2: 2.1±0.4, group 4: 2.0±0.5. Posteriorly, the displacements (mm) were the following: group 1: 1.8±0.6, group 2: 1.9±0.2, group 4: 2.0±0.5. DISCUSSION: The minimally invasive fixation methods investigated in this study all provide sufficient biomechanical stability without one method being superior to the others since differences were not significant regarding anterior and posterior displacements. Even if not significantly, we could reveal that out of all the methods tested the combination of 2 SI-screws with a retrograde transpubic screw (group 3) displayed the least displacement and highest stiffness. These techniques could therefore potentially improve patient's clinical outcome by reducing the surgical invasiveness and procedure time while providing sufficient biomechanical stability. LEVEL OF EVIDENCE: III, comparative in vitro study.


Assuntos
Fraturas Ósseas , Ossos Pélvicos , Fenômenos Biomecânicos , Parafusos Ósseos , Fixação Interna de Fraturas , Fraturas Ósseas/diagnóstico por imagem , Fraturas Ósseas/cirurgia , Humanos , Ossos Pélvicos/diagnóstico por imagem , Ossos Pélvicos/cirurgia , Pelve
14.
Orthop Traumatol Surg Res ; 104(7): 1055-1061, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-30179721

RESUMO

INTRODUCTION: Operative treatments of T-type acetabular fractures are challenging surgical procedures. Open reduction and internal fixation is the standard method for the operative management of these fractures, however this is associated with high blood loss, long hospital stay and longer rehabilitation. Anterior subcutaneous pelvic fixation (internal fixation=INFIX) and retrograde pubic screw fixation have shown promising results in minimally invasive treatment of pelvic ring fractures. For T-type acetabular fractures, however, minimally invasive treatment concepts are still rare. Therefore we performed a mechanical in vitro study to: - investigate the potential favorability of minimally invasive treatment options over the already established open anterior locking plate osteosynthesis of acetabular T-fractures regarding biomechanical stability and post-surgical stiffness; - explore the biomechanical feasibility of the INFIX; - assess its potential ability to reduce the anterior acetabular column. HYPOTHESIS: A minimally invasive treatment of acetabular T-type fractures is biomechanically equivalent to an open anterior plate osteosynthesis. METHODS: Twenty-four synthetic hemipelvis specimens with a T-type acetabular fracture were divided in four groups. A posterior column screw was placed in every pelvis of every group. The anterior column was fixed with: - anterior column screw; - anterior column screw incl. INFIX; - INFIX alone; - 14-hole angular stable locking plate (standard fixation method). Displacement of the anterior column was reduced in group 2+3 using the INFIX. All specimens were cyclically loaded with 200N until a maximum of 600N. Movement/displacement of the fracture fragments were detected with a 3D-ultrasound measuring system. Displacement (mm) and Stiffness (N/mm) of the construction were analyzed. RESULTS: Statistical assessment showed no significant differences between the four fixation types (p>0.05). The 14-whole locking plate (group 4) displayed the overall highest stability with a displacement of 1.3±0.04mm and stiffness of 76.3±2.4N/mm. Anterior screw fixation (group 1) proved to be the minimally invasive fixation method with the least displacement and highest stiffness (1.5±0.2mm, 68.3±6.8N/mm). The combination of an INFIX and an anterior column screw (group 2), showed a mean stiffness of 62.1±6.0N/mm and a mean displacement of 1.7±0.2mm. INFIX only (group 3) presented a displacement of 1.6±0.1mm and a stiffness of 64.5±4.5N/mm. DISCUSSION: Minimally invasive fixation techniques for T-type acetabular fractures show promising biomechanical stability in non- or slightly displaced fractures. Furthermore, INFIX could be a feasible tool for the reduction of the anterior acetabular column. LEVEL OF EVIDENCE: III, case control prospective experimental study.


Assuntos
Acetábulo/lesões , Acetábulo/cirurgia , Parafusos Ósseos , Fixação Interna de Fraturas/instrumentação , Fixação Interna de Fraturas/métodos , Fraturas Ósseas/cirurgia , Fenômenos Biomecânicos , Placas Ósseas , Humanos , Procedimentos Cirúrgicos Minimamente Invasivos/instrumentação , Estudos Prospectivos , Osso Púbico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...