Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Assunto principal
Intervalo de ano de publicação
1.
Sensors (Basel) ; 24(12)2024 Jun 18.
Artigo em Inglês | MEDLINE | ID: mdl-38931730

RESUMO

Two low-cost (LC) monitoring networks, PurpleAir (instrumented by Plantower PMS5003 sensors) and AirQino (Novasense SDS011), were assessed in monitoring PM2.5 and PM10 daily concentrations in the Padana Plain (Northern Italy). A total of 19 LC stations for PM2.5 and 20 for PM10 concentrations were compared vs. regulatory-grade stations during a full "heating season" (15 October 2022-15 April 2023). Both LC sensor networks showed higher accuracy in fitting the magnitude of PM10 than PM2.5 reference observations, while lower accuracy was shown in terms of RMSE, MAE and R2. AirQino stations under-estimated both PM2.5 and PM10 reference concentrations (MB = -4.8 and -2.9 µg/m3, respectively), while PurpleAir stations over-estimated PM2.5 concentrations (MB = +5.4 µg/m3) and slightly under-estimated PM10 concentrations (MB = -0.4 µg/m3). PurpleAir stations were finer than AirQino at capturing the time variation of both PM2.5 and PM10 daily concentrations (R2 = 0.68-0.75 vs. 0.59-0.61). LC sensors from both monitoring networks failed to capture the magnitude and dynamics of the PM2.5/PM10 ratio, confirming their well-known issues in correctly discriminating the size of individual particles. These findings suggest the need for further efforts in the implementation of mass conversion algorithms within LC units to improve the tuning of PM2.5 vs. PM10 outputs.

2.
Sensors (Basel) ; 22(12)2022 Jun 14.
Artigo em Inglês | MEDLINE | ID: mdl-35746261

RESUMO

An innovative low-cost device based on hyperspectral spectroscopy in the near infrared (NIR) spectral region is proposed for the non-invasive detection of moldy core (MC) in apples. The system, based on light collection by an integrating sphere, was tested on 70 apples cultivar (cv) Golden Delicious infected by Alternaria alternata, one of the main pathogens responsible for MC disease. Apples were sampled in vertical and horizontal positions during five measurement rounds in 13 days' time, and 700 spectral signatures were collected. Spectral correlation together with transmittance temporal patterns and ANOVA showed that the spectral region from 863.38 to 877.69 nm was most linked to MC presence. Then, two binary classification models based on Artificial Neural Network Pattern Recognition (ANN-AP) and Bagging Classifier (BC) with decision trees were developed, revealing a better detection capability by ANN-AP, especially in the early stage of infection, where the predictive accuracy was 100% at round 1 and 97.15% at round 2. In subsequent rounds, the classification results were similar in ANN-AP and BC models. The system proposed surpassed previous MC detection methods, needing only one measurement per fruit, while further research is needed to extend it to different cultivars or fruits.


Assuntos
Malus , Frutas/química , Malus/química , Redes Neurais de Computação
3.
Sensors (Basel) ; 18(9)2018 Aug 28.
Artigo em Inglês | MEDLINE | ID: mdl-30154366

RESUMO

A low-cost air quality station has been developed for real-time monitoring of main atmospheric pollutants. Sensors for CO, CO2, NO2, O3, VOC, PM2.5 and PM10 were integrated on an Arduino Shield compatible board. As concerns PM2.5 and PM10 sensors, the station underwent a laboratory calibration and later a field validation. Laboratory calibration has been carried out at the headquarters of CNR-IBIMET in Florence (Italy) against a TSI DustTrak reference instrument. A MATLAB procedure, implementing advanced mathematical techniques to detect possible complex non-linear relationships between sensor signals and reference data, has been developed and implemented to accomplish the laboratory calibration. Field validation has been performed across a full "heating season" (1 November 2016 to 15 April 2017) by co-locating the station at a road site in Florence where an official fixed air quality station was in operation. Both calibration and validation processes returned fine scores, in most cases better than those achieved for similar systems in the literature. During field validation, in particular, for PM2.5 and PM10 mean biases of 0.036 and 0.598 µg/m³, RMSE of 4.056 and 6.084 µg/m³, and R² of 0.909 and 0.957 were achieved, respectively. Robustness of the developed station, seamless deployed through a five and a half month outdoor campaign without registering sensor failures or drifts, is a further key point.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...