Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Diagn Microbiol Infect Dis ; 107(4): 116085, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37801888

RESUMO

BACKGROUND: We evaluated pre- and postimplementation of Virtuo on outcome in patients with gram-negative bacteremia using a quasiexperimental time-in-motion design. METHODS: Becton Dickinson BACTEC™ 9000 series (Bactec) (2018) and Virtuo system (2020) were utilized in a decentralized and centralized process, respectively. Data collected in August-December in 2018 and 2020 were analyzed with SPSS (ver 28). RESULTS: For 185 patients in each time period, patient age, gender, length of hospitalization were not different. However, blood culture (BC) volume was significantly lower in 2020 (7.1 ± 2.6 mL) compared to 2018 (8.9 ± 1.9 mL). Time from BC draw and time from pathogen identification (ID) to treatment change were both significantly faster in 2020 (52.9 ± 38.3 hours; 15.1 ± 27.4 hours), compared to 2018 (65.0 ± 46.3 hours; 23.8 ± 33.8), respectively. CONCLUSIONS: Replacement of decentralized Bactec with centralized Virtuo, resulted in significant improvement in management of patients gram-negative bacteremia.


Assuntos
Bacteriemia , Hemocultura , Humanos , Hemocultura/métodos , Fatores de Tempo , Bacteriemia/diagnóstico , Bacteriemia/tratamento farmacológico , Meios de Cultura , Técnicas Bacteriológicas/métodos
3.
Diagn Microbiol Infect Dis ; 95(2): 208-211, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31279585

RESUMO

We sought to evaluate time for bacterial culture and initiation of appropriate therapy for patients, from 2017 (without rapid diagnostic test (RDT) and Antimicrobial Stewardship Program (ASP)) and 2018 (with RDT and ASP). Time to identification (ID) was significantly faster in 2018 (2018 24.9 ±â€¯14.4, 2017 33.8 ±â€¯17 h, P = 0.001). Time to antimicrobial susceptibility test (AST) results was significantly faster for patients in 2018 compared to 2017 (18.2 ±â€¯14 h compared to 28.5 ±â€¯14.9 h, P < 0.001). Length of hospital stay for enrolled patients was significantly shorter in 2018 compared to 2017 (2018 10.7 ±â€¯11.1 days and 2017 15.5 ±â€¯18.1 days, P = 0.05). Length of antimicrobial therapy for enrolled patients was significantly shorter for 2018 (2018 6.7 ±â€¯3.8 d vs. 2017 8.8 ±â€¯7.8 d, P = 0.036). These results demonstrate MALDI-TOF/Vitek 2 leads to an average 21.5 h faster ID and AST results that can be acted upon by ASP for antimicrobial recommendations.


Assuntos
Antibacterianos/uso terapêutico , Gestão de Antimicrobianos , Infecções/diagnóstico , Infecções/tratamento farmacológico , Idoso , Idoso de 80 Anos ou mais , Antibacterianos/farmacologia , Feminino , Hospitalização , Humanos , Infecções/microbiologia , Tempo de Internação , Masculino , Testes de Sensibilidade Microbiana , Pessoa de Meia-Idade , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz , Fatores de Tempo , Resultado do Tratamento
4.
Diagn Microbiol Infect Dis ; 79(3): 384-6, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24813687

RESUMO

Three ertapenem-resistant Klebsiella pneumoniae carrying bla(KPC-2) were isolated from a single patient in Nebraska over a span of 5 months. A comparative analysis of the genetic relatedness of these isolates was investigated using pulsed-field gel electrophoresis, multilocus sequence typing, and whole genome mapping.


Assuntos
Mapeamento Cromossômico , Infecções por Klebsiella/microbiologia , Klebsiella pneumoniae/enzimologia , Klebsiella pneumoniae/genética , beta-Lactamases/metabolismo , Antibacterianos/farmacologia , Eletroforese em Gel de Campo Pulsado , Genótipo , Humanos , Klebsiella pneumoniae/classificação , Klebsiella pneumoniae/isolamento & purificação , Masculino , Testes de Sensibilidade Microbiana , Pessoa de Meia-Idade , Tipagem de Sequências Multilocus , Nebraska , beta-Lactamases/genética
6.
Am J Clin Pathol ; 133(1): 110-3, 2010 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-20023266

RESUMO

The new MONOLISA Bio-Rad kits were compared to DiaSorin kits for the detection of hepatitis B virus (HBV) total core (HBcTAb) and surface (HBsAb) antibodies on the Bio-Rad Evolis immunoanalyzer. The resolved sensitivities, specificities, positive and negative predictive values, and overall accuracy were 91%, 100%, 100%, 96%, and 97%, respectively, for HBcTAb and 99%, 95%, 96%, 99%, and 97%, respectively, for HBsAb. Whereas accuracy and reagent cost were comparable between the kits, Bio-Rad kits required less specimen volume and less instrument processing time to results than the DiaSorin kits.


Assuntos
Anticorpos Anti-Hepatite B/sangue , Antígenos do Núcleo do Vírus da Hepatite B/imunologia , Antígenos de Superfície da Hepatite B/imunologia , Vírus da Hepatite B/imunologia , Hepatite B/imunologia , Kit de Reagentes para Diagnóstico , Reações Falso-Positivas , Humanos , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Fatores de Tempo
7.
Antimicrob Agents Chemother ; 52(10): 3814-6, 2008 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-18663030
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...