Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Chemistry ; 29(1): e202202729, 2023 Jan 02.
Artigo em Inglês | MEDLINE | ID: mdl-36194105

RESUMO

The protonation of commercially available porphyrin ligands yields a class of bifunctional catalysts able to promote the synthesis of N-alkyl oxazolidinones by CO2 cycloaddition to corresponding aziridines. The catalytic system does not require the presence of any Lewis base or additive, and shows interesting features both in terms of cost effectiveness and eco-compatibility. The metal-free methodology is active even with a low catalytic loading of 1 % mol, and the chemical stability of the protonated porphyrin allowed it to be recycled three times without any decrease in performance. In addition, a DFT study was performed in order to suggest how a simple protonated porphyrin can mediate CO2 cycloaddition to aziridines to yield oxazolidinones.


Assuntos
Aziridinas , Oxazolidinonas , Porfirinas , Dióxido de Carbono , Metais
2.
Ann Biomed Eng ; 42(10): 2106-16, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25069973

RESUMO

Congenital Central Hypoventilation Syndrome is a genetic disease characterized by alveolar hypoventilation and autonomic dysregulation. Patients have hypoventilations, especially during sleep, conditioning hypercapnia which can lead to neurological damage and death. They therefore need mechanical ventilators, that provide sufficient gas exchange, and pulse-oximeters that monitor oxy-hemoglobin blood concentration. Due to the restrictions regarding domiciliary assistive devices, the presence of a caregiver is required all night long. Currently, the only alarm systems available are the ones integrated in the ventilators and monitoring systems. During the night, multiple false alarms may occur, interrupting the sleep and causing anxiety. In this work we describe an assistive device that acquires real-time data from a pulse-oximeter, provides a multisensory stimulation if oxygen saturation falls under a certain threshold, and wakes up the patient if the hypoxia is severe. Tests on healthy subjects have shown that the device guarantees rapid awakenings, with a stimulator-dependent efficacy, and that it does not affect sleep efficiency. The purpose of the device is to determine a gentle awakening if mild hypoxia conditions persist, and to assure rapid awakening when a severe hypoxia occurs, reducing false alarms, improving the quality of sleep and increasing the self-sufficiency of the patients.


Assuntos
Hipoventilação/congênito , Hipóxia/diagnóstico , Monitorização Fisiológica/instrumentação , Apneia do Sono Tipo Central/fisiopatologia , Sono/fisiologia , Adolescente , Adulto , Feminino , Humanos , Hipoventilação/sangue , Hipoventilação/fisiopatologia , Hipóxia/fisiopatologia , Lactente , Masculino , Oximetria , Oxigênio/sangue , Qualidade de Vida , Apneia do Sono Tipo Central/sangue , Adulto Jovem
3.
Bioinformatics ; 27(9): 1313-5, 2011 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-21398667

RESUMO

UNLABELLED: We propose a C++ class library developed to the purpose of making the implementation of sequence analysis algorithms easier and faster when genomic annotations and variations need to be considered. The library provides a class hierarchy to seamlessly bind together annotations of genomic elements to sequences and to algorithm results; it allows to evaluate the effect of mutations/variations in terms of both element position shifts and of algorithm results, limiting recalculation to the minimum. Particular care has been posed to keep memory and time overhead into acceptable limits. AVAILABILITY AND IMPLEMENTATION: A complete tutorial as well as a detailed doxygen generated documentation and source code is freely available at http://bioinformatics.emedea.it/geco, under the GPL license. The library was written in standard ISO C++, and does not depend on external libraries.


Assuntos
Algoritmos , Genômica/métodos , Linguagens de Programação , Análise de Sequência de DNA/métodos , Software , Sequência de Bases , Biblioteca Gênica , Alinhamento de Sequência
4.
J Chem Phys ; 124(19): 194508, 2006 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-16729826

RESUMO

We present a combined x-ray absorption spectroscopy/computational study of water in hydrochloric acid (HCl) solutions of varying concentration to address the structure and bonding of excess protons and their effect on the hydrogen bonding network in liquid water. Intensity variations and energy shifts indicate changes in the hydrogen bonding structure in water as well as the local structure of the protonated complex as a function of the concentration of protons. In particular, in highly acidic solutions we find a dominance of the Eigen form, H(3)O(+), while the proton is less localized to a specific water under less acidic conditions.

5.
Conf Proc IEEE Eng Med Biol Soc ; 2006: 6076-9, 2006.
Artigo em Inglês | MEDLINE | ID: mdl-17945934

RESUMO

In otoneurology the analysis of subjective vertical perception is a useful tool to investigate macular function and central otolithic pathways. The Subjective Vertical is perceived using visual, vestibular and proprioceptive subsystems. In this work we propose a new device that can assess just the tactile/somatosensory subsystem contribution compared to other commercial devices that investigate the other subsystems. The developed instrumentation is made by a bar equipped with two orthogonally oriented Micro Electro Mechanical System accelerometers that transmit data to a remote visualization apparatus. During the examination, the patient handles the bar and must align it along the direction perceived as "vertical"


Assuntos
Monitorização Fisiológica/métodos , Neurologia/instrumentação , Percepção Espacial , Percepção Visual , Redes de Comunicação de Computadores , Eletrofisiologia , Desenho de Equipamento , Humanos , Microcomputadores , Modelos Estatísticos , Modelos Teóricos , Neurologia/métodos , Orientação , Testes de Função Vestibular , Visão Ocular
6.
Phys Chem Chem Phys ; 7(15): 2854-8, 2005 Aug 07.
Artigo em Inglês | MEDLINE | ID: mdl-16189603

RESUMO

We analyze the performance of two different core-hole potentials in the theoretical modeling of XAS of ice, liquid and gas phase water; the use of a full core-hole (FCH) in the calculations, as suggested by Hetenyi et al. [B. Hetenyi, F. De Angelis, P. Giamozzi and R. Car, J. Chem. Phys., 2004, 120(18), 8632], gives poor agreement with experiment in terms of intensity distribution as well as transition energies, while the half core hole (HCH) potential, in the case of water, provides a better compromise between initial and final state effects, leading to good agreement with the experimental data.


Assuntos
Análise Espectral/métodos , Água/química , Gases , Ligação de Hidrogênio , Gelo , Modelos Teóricos , Fótons , Análise Espectral Raman/métodos , Termodinâmica , Raios X
7.
J Phys Chem B ; 109(20): 10194-203, 2005 May 26.
Artigo em Inglês | MEDLINE | ID: mdl-16852236

RESUMO

We have measured the X-ray absorption (XA) spectrum of liquid (298 K) methanol at the oxygen and carbon K edges. The 4a(1) orbital at the O K edge exhibits a pronounced sensitivity to the formation of intermolecular hydrogen bonds, with significant differences observed between the vapor and bulk spectra, whereas the C K edge reveals only subtle corresponding spectral changes. Comparison with DFT computed spectra of model methanol clusters indicates that the bulk liquid comprises long chains (n > 6) and rings of hydrogen-bonded monomers.

8.
J Chem Phys ; 121(20): 10065-75, 2004 Nov 22.
Artigo em Inglês | MEDLINE | ID: mdl-15549881

RESUMO

We describe the implementation of a simple technique to simulate core-level spectra within the Car-Parrinello plane-waves molecular dynamics framework. The x-ray absorption (XA) spectra are generated using the transition potential technique with the effect of the core hole included through a specifically developed pseudopotential for the core-excited atom. Despite the lack of 1s core orbitals in the pseudopotential treatment, the required transition moments are accurately calculated without reconstruction of the all-electron orbitals. The method is applied to the oxygen XA spectra of water in its various aggregation states, but it is transferable to any first-row element. The computed spectra are compared favorably with the results from all-electron cluster calculations, as well as with experimental data. The periodicity of the plane-wave technique improves the description of condensed phases. The molecular dynamics simulation enables in principle a proper treatment of thermal effects and dynamical averaging in complex systems.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...