Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Crit Care ; 24(1): 33, 2020 02 03.
Artigo em Inglês | MEDLINE | ID: mdl-32014041

RESUMO

BACKGROUND: Post-traumatic cerebral infarction (PTCI) is common after traumatic brain injury (TBI). It is unclear what the occurrence of a PTCI is, how it impacts the long-term outcome, and whether it adds incremental prognostic value to established outcome predictors. METHODS: This was a prospective multicenter cohort study of moderate and severe TBI patients. The primary objective was to evaluate if PTCI was an independent risk factor for the 6-month outcome assessed with the Glasgow Outcome Scale (GOS). We also assessed the PTCI occurrence and if it adds incremental value to the International Mission for Prognosis and Clinical Trial design in TBI (IMPACT) core and extended models. RESULTS: We enrolled 143 patients, of whom 47 (32.9%) developed a PTCI. In the multiple ordered logistic regression, PTCI was retained in both the core and extended IMPACT models as an independent predictor of the GOS. The predictive performances increased significantly when PTCI was added to the IMPACT core model (AUC = 0.73, 95% C.I. 0.66-0.82; increased to AUC = 0.79, 95% CI 0.71-0.83, p = 0.0007) and extended model (AUC = 0.74, 95% C.I. 0.65-0.81 increased to AUC = 0.80, 95% C.I. 0.69-0.85; p = 0.00008). Patients with PTCI showed higher ICU mortality and 6-month mortality, whereas hospital mortality did not differ between the two groups. CONCLUSIONS: PTCI is a common complication in patients suffering from a moderate or severe TBI and is an independent risk factor for long-term disability. The addition of PTCI to the IMPACT core and extended predictive models significantly increased their performance in predicting the GOS. TRIAL REGISTRATION: The present study was registered in ClinicalTrial.gov with the ID number NCT02430324.


Assuntos
Lesões Encefálicas Traumáticas/complicações , Infarto Cerebral/etiologia , Avaliação de Resultados em Cuidados de Saúde/normas , Adulto , Área Sob a Curva , Lesões Encefálicas Traumáticas/epidemiologia , Infarto Cerebral/epidemiologia , Estudos de Coortes , Feminino , Escala de Resultado de Glasgow/estatística & dados numéricos , Humanos , Itália/epidemiologia , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Avaliação de Resultados em Cuidados de Saúde/estatística & dados numéricos , Estudos Prospectivos , Curva ROC , Estatísticas não Paramétricas
2.
Eur J Anaesthesiol ; 35(8): 605-612, 2018 08.
Artigo em Inglês | MEDLINE | ID: mdl-29889671

RESUMO

BACKGROUND: Unpredictable difficult laryngoscopy remains a challenge for anaesthesiologists, especially if difficult ventilation occurs during standard laryngoscopy. Accurate airway assessment should always be performed, but the common clinical screening tests have shown low sensitivity and specificity with a limited predictive value. Ultrasound-based airway assessment has been proposed recently as a useful, simple, noninvasive bedside tool as an adjunct to clinical methods, but to date, few studies are available about the potential role of ultrasound in difficult airway evaluation, and these are mostly limited to specific groups of patients. OBJECTIVES: The aim of this study was to determine the correlation between the sonographic measurements of anterior cervical soft tissues thickness and Cormack-Lehane grade view at direct laryngoscopy in patients with normal clinical screening tests. DESIGN: Prospective, single blinded, observational study. SETTING: Operating theatre of a teaching hospital from May 2017 to September 2017. PATIENTS: A total of 301 patients at least 18 years of age undergoing elective surgery under general anaesthesia with tracheal intubation were included in the study. OUTCOME MEASURES: Pre-operative evaluation was performed before surgery, demographic variables were collected and clinical screening tests to predict a difficult airway were performed. Patients with predicted difficult intubation were excluded. A 10 to 13-MHz linear ultrasound transducer was placed in the transverse plane and the thickness of the anterior cervical soft tissues was measured at two levels [thyrohyoid membrane (pre-epiglottic space) and vocal cords (laryngeal inlet)] with the patient's head in a neutral position. At each level, the distance from the skin in the median axis and the surrounding area was measured. The laryngoscopic view was graded by a different anaesthetist with more than 5 years of experience with direct laryngoscopy, blinded to the ultrasound assessments. RESULTS: The 'pre-epiglottic space thickness' at the level of thyrohyoid membrane was measured as the median distance from skin to epiglottis (mDSE) and the pre-epiglottic area was calculated; the mDSE cut-off value of 2.54 cm (sensitivity 82%, specificity 91%) and the pre-epiglottic area cut-off value of 5.04 cm (sensitivity 85%, specificity 88%) were the best predictors of a Cormack-Lehane grade at least 2b at direct laryngoscopy and of difficult intubation. The cut-off value of mDSE showed greater sensitivity in female patients (94 vs. 86%) and greater specificity in male patients (92 vs. 83%). No correlation was found between difficult laryngoscopy and ultrasound assessments at the level of the vocal cords. CONCLUSION: Airways ultrasounds might be considered as a predictor of restricted/difficult laryngoscopy and unpredicted difficult intubation. TRIAL REGISTRATION: ClinicalTrials.gov: NCT03547193.


Assuntos
Manuseio das Vias Aéreas/normas , Laringoscopia/normas , Pescoço/diagnóstico por imagem , Ultrassonografia de Intervenção/normas , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Manuseio das Vias Aéreas/métodos , Procedimentos Cirúrgicos Eletivos/métodos , Procedimentos Cirúrgicos Eletivos/normas , Epiglote/diagnóstico por imagem , Feminino , Humanos , Intubação Intratraqueal/métodos , Intubação Intratraqueal/normas , Laringoscopia/métodos , Laringe/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Método Simples-Cego , Ultrassonografia de Intervenção/métodos , Prega Vocal/diagnóstico por imagem , Adulto Jovem
3.
J Cardiovasc Med (Hagerstown) ; 12(2): 116-21, 2011 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-21135588

RESUMO

BACKGROUND: Radial arterial access is becoming increasingly popular for coronary angiography and angioplasty. The technique is, however, more demanding than femoral arterial access, and hemostasis is not care-free. A quality assurance program was run by our nursing staff, with patient follow-up, to monitor radial arterial access implementation in our laboratory. METHOD: In 973 consecutive patients, both a hydrophilic sheath and an inflatable bandage for hemostasis were used. Bandage inflation volume and time were both reduced through subsequent data audit and protocol changes (A = 175 patients; B = 297; C = 501). RESULTS: An increase was achieved in the percentage of patients with neither loss of radial pulse nor hematoma of any size (A = 81.3%, B = 90.9%, C = 92.2%, P < 0.001), and no discomfort at all (A = 44.2%, B = 75.1%, C = 89.3%, P < 0.001). Follow-up was available for 965 patients (99%), and in 956, the access site could be re-inspected at least once. There were no vascular complications. Overall, the radial artery pulse was absent at latest follow-up in 0.6% of cases (95% confidence interval 0.21-1.05%). In 460 consecutive patients with complete assessment in protocol C, a palpable arterial pulse was absent in 5% of cases at about 20 h after hemostasis. Barbeau's test was positive in 26.5% of patients (95% confidence interval 22.5-30.6%). They had a significantly lower body weight, a lower systolic blood pressure at hemostasis, and a higher bandage inflation volume; a hematoma of any size and the report of any discomfort were also more frequent. Barbeau's test returned to normal in 30% of them 3-60 days later. CONCLUSION: Our nurse-led quality assurance program helped us in reducing minor vascular sequelae and improving patient comfort after radial access. Early occlusion of the radial artery as detected by pulse oxymeter is frequent, often reversible, and may be mostly related to trauma/occlusion of the artery during hemostasis.


Assuntos
Cateterismo Cardíaco/enfermagem , Hemorragia/prevenção & controle , Técnicas Hemostáticas/enfermagem , Recursos Humanos de Enfermagem Hospitalar/normas , Garantia da Qualidade dos Cuidados de Saúde/normas , Artéria Radial , Idoso , Arteriopatias Oclusivas/etiologia , Arteriopatias Oclusivas/prevenção & controle , Cateterismo Cardíaco/efeitos adversos , Distribuição de Qui-Quadrado , Auditoria Clínica , Feminino , Hematoma/etiologia , Hematoma/prevenção & controle , Hemorragia/etiologia , Humanos , Itália , Masculino , Pessoa de Meia-Idade , Oximetria/enfermagem , Punções , Medição de Risco , Fatores de Risco
4.
Eur J Cardiovasc Nurs ; 5(1): 31-6, 2006 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-15993648

RESUMO

BACKGROUND: Vascular access complications may be a cause of discomfort, prolonged hospital stay, and impaired outcomes in patients undergoing cardiac catheterisation. AIMS: To assess vascular access complication in our patients with/without the use of closure devices as a first local benchmark for subsequent quality improvement. METHODS: A nurse-led single-centre prospective survey of all vascular access complications in consecutive patients submitted to cardiac catheterisation during 4 months. RESULTS: The radial and femoral access were used in 78 (14%) and 470 (83%), respectively, of 564 procedures, and a closure device was used in 136 of the latter. A haematoma (any size) was isolated and uneventful in 9.6% of cases. More severe complications (haemoglobin loss >2 g, need for blood transfusion or vascular repair) occurred in 1.2% of cases, namely: in none of the procedures with radial access, and in 0.4% and 2.4% of femoral diagnostic and interventional coronary procedures, respectively. During complicated (n=40) vs uncomplicated (n=172) transfemoral interventions, the activated coagulation time was 309+/-83 vs 271+/-71 s (p=0.004), but the use of closure devices was similar. CONCLUSION: Severe vascular access complications in our patients were fewer than in most reports, and virtually absent in radial procedures. Vigorous anticoagulation was associated with increased complications in our patients, but closure devices were not. A new policy including both the use of the radial access whenever possible, and a less aggressive anticoagulation regimen during transfemoral interventions will be tested.


Assuntos
Angioplastia Coronária com Balão/efeitos adversos , Cateterismo Cardíaco/efeitos adversos , Hematoma/prevenção & controle , Cuidados Pós-Operatórios/enfermagem , Garantia da Qualidade dos Cuidados de Saúde/organização & administração , Idoso , Anemia/sangue , Anemia/etiologia , Anemia/terapia , Angioplastia Coronária com Balão/métodos , Angioplastia Coronária com Balão/enfermagem , Anticoagulantes/efeitos adversos , Benchmarking/organização & administração , Transfusão de Sangue , Cateterismo Cardíaco/métodos , Cateterismo Cardíaco/enfermagem , Protocolos Clínicos/normas , Angiografia Coronária , Feminino , Artéria Femoral/lesões , Necessidades e Demandas de Serviços de Saúde , Hematoma/etiologia , Técnicas Hemostáticas/enfermagem , Técnicas Hemostáticas/normas , Humanos , Masculino , Pessoa de Meia-Idade , Pesquisa em Avaliação de Enfermagem , Cuidados Pós-Operatórios/normas , Estudos Prospectivos , Artéria Radial/lesões , Fatores de Risco , Gestão da Qualidade Total/organização & administração
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...