Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 173
Filtrar
3.
CLAO J ; 27(4): 221-4, 2001 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-11725986

RESUMO

PURPOSE: To further study the immunological localization of Bcl-2 protein in human corneal epithelium. METHODS: Three anti-human Bcl-2 antibodies, generated against amino acid residues (aa) 4-21 (polyclonal), 1-205 (monoclonal), and 41-54 (monoclonal), were used to localize Bcl-2 protein immunocytochemically in fresh eye bank donor human corneas. RESULTS: In the central corneal epithelium, two anti-Bcl-2 antibodies (aa 4-21 and aa 1-205) showed intense cytoplasmic staining of basal epithelial cells. These antibodies produced similar staining in the limbal epithelium, with gradually less intense staining of wing and superficial cells. By contrast, as previously reported, a monoclonal antibody to aa 41-54 stained nuclei of all epithelial cell layers with the exception of some surface corneal epithelial cells; this antibody also demonstrated very bright anti-Bcl-2 staining of Langerhans cells localized in the peripheral corneal epithelium. CONCLUSION: In our previous study, Bcl-2 protein was immunocytochemically localized to the nuclear compartment of all corneal epithelial cell layers with the use of antibodies specific for the regulatory flexible loop domain of Bcl-2. However, Bcl-2 can also be uniquely localized to the cytoplasm of the corneal epithelium with the use of antibodies generated against aa 4-21 and aa 1-205. Taken together, these results using epitope specific antibodies indicate that different epitopes on the Bcl-2 protein are available for antibody binding within different cells and cellular compartments, suggesting that proliferation and differentiation may lead to changes in the Bcl-2 structure and conformation within different compartments of the epithelial cells themselves.


Assuntos
Anticorpos Monoclonais/imunologia , Epitélio Corneano/imunologia , Epitopos/imunologia , Fragmentos de Peptídeos/imunologia , Proteínas Proto-Oncogênicas c-bcl-2/imunologia , Idoso , Western Blotting , Técnica Indireta de Fluorescência para Anticorpo , Humanos , Pessoa de Meia-Idade
4.
Invest Ophthalmol Vis Sci ; 42(12): 2804-12, 2001 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-11687521

RESUMO

PURPOSE: To examine cell proliferation of the normal corneal epithelium and during extended rigid gas-permeable (RGP) lens wear. METHODS: Twenty-three New Zealand White rabbits were fitted unilaterally with either a low oxygen transmissible (Dk/t) or hyper-Dk/t RGP lens, with the other eye serving as a control. The rabbits were injected with 5-bromo-2-deoxyuridine (BrdU) 24-hours later and killed at three time points: 1, 3, and 7 days after injection. Corneas were processed for immunocytochemistry, and sequential digital images were taken from the superior limbus to the central epithelium with an epifluorescence microscope. The total number of BrdU-labeled cell pairs was quantified. RESULTS: The limbus in normal corneas was significantly less populated with BrdU-labeled cells than the central and peripheral epithelium (P < 0.05). The peripheral epithelium adjacent to the limbus was marked by a peak of labeled cells (P < 0.05). Both types of RGP lenses produced an increase in BrdU labeling in the limbus and a dramatic decrease in the central epithelium (80% for low Dk/t, 37% for hyper Dk/t). At day 3 and 7 after BrdU injection, the low-Dk/t lens continued to show decreased BrdU labeling centrally, whereas the limbus remained increased. Hyper-Dk/t lens wear however, showed persistent limbal elevation but equivalent numbers of BrdU-labeled cells centrally at days 3 and 7, compared with control corneas. Keratocytes unexpectedly showed BrdU labeling during RGP lens wear. CONCLUSIONS: Limbus, peripheral, and central epithelium were characterized by different proliferation rates in the normal rabbit cornea. RGP lens wear significantly altered the homeostatic proliferation pattern of the epithelium with the low-Dk/t lens having the most dramatic effect. RGP contact lens wear appears to stimulate proliferation of keratocytes.


Assuntos
Divisão Celular , Lentes de Contato , Epitélio Corneano/citologia , Animais , Bromodesoxiuridina/metabolismo , Divisão Celular/fisiologia , DNA/biossíntese , Replicação do DNA , Epitélio Corneano/metabolismo , Técnica Indireta de Fluorescência para Anticorpo , Microscopia de Fluorescência , Oxigênio/metabolismo , Coelhos
6.
CLAO J ; 27(3): 137-43, 2001 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-11506438

RESUMO

PURPOSE: To study Bcl-2 expression and apoptotic cell shedding of the rabbit corneal epithelium during extended wear of low and hyper Dk rigid gas permeable (RGP) contact lenses. METHODS: Rabbits were fit with either a low or a hyper Dk RGP lens (Dk/Ltotal= 10 and 97). The rabbits wore the lenses for either 24 hours, 3 days, or 1 week at which point they were humanely sacrificed. Immunocytochemistry and western blot analyses were performed to detect Bcl-2 in the corneal epithelium; TUNEL assay (TdT-mediated dUTP nick-end labeling) was used to identify apoptotic epithelial cells. RESULTS: 1) Immunocytochemistry: In the normal cornea, antibodies to Bcl-2 uniformly stained nuclei of all epithelial cell layers. Occasional surface epithelial cells, however, showed no anti-Bcl-2 nuclear staining; concomitant TUNEL assay revealed that all TUNEL-labeled-surface cells were Bcl-2 negative. By contrast, RGP contact lens wear, regardless of test lens oxygen transmissibility or lens wearing interval, significantly decreased both the total number of Bcl-2 negative and TUNEL-labeled cells on the epithelial surface (P < 0.05). In addition, contact lens wear was associated with labeling of keratocytes with TUNEL assay in the anterior stroma. 2) Western blot analysis: Total epithelial layer Bcl-2 expression was markedly decreased in the low Dk lens test group but was similar to control values in the hyper Dk lens test group. CONCLUSION: Bcl-2 protein seems to play an important role in the regulation of apoptotic cell shedding in the normal rabbit corneal epithelium. The identical staining pattern was seen in previous studies of the normal human cornea. RGP contact lens wear, however, appears to block the changes in Bcl-2 protein prior to apoptotic surface cell shedding, suggesting a lens-related anti-apoptotic effect. Taken together, these findings may explain why contact lens wear reduces surface cell exfoliation as previously reported in human studies.


Assuntos
Apoptose , Lentes de Contato , Epitélio Corneano/metabolismo , Proteínas Proto-Oncogênicas c-bcl-2/metabolismo , Animais , Western Blotting , Epitélio Corneano/patologia , Técnica Indireta de Fluorescência para Anticorpo , Marcação In Situ das Extremidades Cortadas , Oxigênio/metabolismo , Permeabilidade , Coelhos
7.
Cornea ; 20(6): 622-7, 2001 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-11473164

RESUMO

PURPOSE: Exposure to Acanthamoebaspecies appears to be ubiquitous, as 50% to 100% of healthy human subjects display anti-Acanthamoebaantibodies. However, the presence of specific anti-Acanthamoebaantibodies in the serum and tears of patients has not been investigated. The prevalence of serum immunoglobulin G (IgG) and tear IgA against three species of Acanthamoebawas assessed in healthy subjects and patients with Acanthamoebakeratitis. METHODS: The level of specific serum IgG and tear IgA against A. castellanii, A. astronyxis, and A. culbertsoniin the sera of 23 patients and 25 healthy subjects was tested by enzyme-linked immunosorbent assays. Total serum IgM, IgG, and IgA concentrations were measured by nephelometry. Acanthamoebakeratitis was diagnosed clinically and confirmed by in vivo confocal microscopy. In some patients, corneal biopsies were also performed and trophozoites were cultured on lawns of Escherichia colion non-nutrient agar. RESULTS: All healthy subjects and patients with Acanthamoebakeratitis had detectable serum IgG antibodies against all Acanthamoebaantigens. However, patients with Acanthamoebakeratitis had significantly higher anti-AcanthamoebaIgG antibody titers than healthy subjects. In contrast, Acanthamoeba-specific tear IgA was significantly lower in patients with Acanthamoebakeratitis in comparison with healthy subjects. Total serum immunoglobulins did not differ significantly between healthy subjects and patients with Acanthamoebakeratitis. CONCLUSIONS: The results suggest that a low level of anti-AcanthamoebaIgA antibody in the tears appears to be associated with Acanthamoebakeratitis.


Assuntos
Ceratite por Acanthamoeba/imunologia , Acanthamoeba/imunologia , Anticorpos Antiprotozoários/análise , Imunoglobulina A Secretora/análise , Imunoglobulina G/sangue , Lágrimas/imunologia , Ceratite por Acanthamoeba/diagnóstico , Animais , Antígenos de Protozoários/imunologia , Ensaio de Imunoadsorção Enzimática , Feminino , Humanos , Imunoglobulina M/sangue , Masculino , Microscopia Confocal
8.
Toxicol Pathol ; 29(3): 308-19, 2001.
Artigo em Inglês | MEDLINE | ID: mdl-11442017

RESUMO

Despite differences in the processes leading to tissue damage, the ocular irritation response to various surfactants, two concentrations of an acid and an alkali, and an acetone, alcohol, aromatic amine, and aldehyde has been shown to depend on the extent of initial injury. The purpose of this study was to assess the extent to which this fundamental relationship exists for bleaching agents in the rabbit low-volume eye test. Ten microl of sodium perborate monohydrate (NaBO3), sodium hypochlorite (NaOCl), 10% hydrogen peroxide (H2O2), and 15% H2O2 was applied directly to the cornea of the right eye of each rabbit. Macroscopic assessments for irritation were made 3 hours after dosing and periodically until 35 days. Light microscopic examinations were conducted on tissues obtained at 3 hr and on 1, 3, and 35 days. In vivo confocal microscopy (CM) and measurements of dead corneal epithelial cells and keratocytes at 3 hours and 1 day were used to characterize quantitatively initial corneal injury, while in vivo CM performed at 3 hours and 1, 3, 7, 14, and 35 days was used to characterize quantitatively the corneal changes over time. The changes with NaBO3 and NaOCl were consistent with mild irritancy. For both, corneal injury was limited to the epithelium and superficial stroma. The changes with 10% H202 and 15% H2O2 were consistent with severe irritation. Both concentrations affected the epithelium and deep stroma, with 15% H2O2 also at times affecting the endothelium. However, unlike other irritants previously studied, with 10% H2O2 and 15% H2O2 there was an incongruity between the extent of epithelial and stromal injury, with stromal injury being more extensive than epithelial injury. A similar, although less dramatic, effect was observed with NaBO3. Additionally, there was still significant keratocyte loss at 35 days with 10% H2O2 and 15% H2O2 even though the eyes at times were considered to be macroscopically normal. These observations highlight the need to include both epithelial and stromal components in an ex vivo or in vitro alternative assay. In conclusion, these results continue to support and extend our hypothesis that ocular irritation is principally defined by the extent of initial injury despite clear differences in the means by which irritants cause tissue damage. Importantly, we have identified unique differences in the ocular injury and responses occurring with bleaching agents that are important to consider in the development and validation of alternative ocular irritation tests to characterize a broad range of materials differing in type and irritancy.


Assuntos
Boratos/toxicidade , Córnea/efeitos dos fármacos , Doenças da Córnea/patologia , Peróxido de Hidrogênio/toxicidade , Irritantes/toxicidade , Hipoclorito de Sódio/toxicidade , Animais , Túnica Conjuntiva/efeitos dos fármacos , Túnica Conjuntiva/patologia , Córnea/patologia , Doenças da Córnea/induzido quimicamente , Relação Dose-Resposta a Droga , Iris/efeitos dos fármacos , Iris/patologia , Masculino , Microscopia Confocal , Coelhos , Fatores de Tempo
9.
Exp Eye Res ; 73(2): 247-55, 2001 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-11446775

RESUMO

The purpose of this study was to determine the localization of Bcl-2 protein in the human cornea. Anti-human Bcl-2 monoclonal antibodies (MAbs) against selective Bcl-2 peptide sequences were used to localize Bcl-2 protein immunocytochemically in fresh eye bank donor human corneas (n = 4). Specificity of each MAb was determined by Western blot analysis of pooled protein extracted from human corneal epithelium (n = 3). Expression of Bcl-2 protein in apoptotic surface epithelial cells was detected by co-labeling with TUNEL assay and anti-Bcl-2 antibody staining. Two MAbs specific for amino acids residues (aa) 41-54 within the loop domain of Bcl-2 protein stained nuclei of all corneal epithelial cell layers. MAb specific for aa 61-76, also within the loop domain, produced faint nuclei and nuclear envelope staining. Occasional corneal surface epithelial cells however, consistently lacked anti-Bcl-2 nuclear staining with these three MAbs; concomitant TUNEL assay revealed that all TUNEL positive-surface cells were Bcl-2 negative. In the stroma, keratocytes showed similar but weak anti-Bcl-2 staining. All corneal endothelial cells showed intense nuclear staining with MAbs, with no gradient or absence of staining. In summary, Bcl-2 protein can be localized to the nuclei and nuclear envelope of corneal epithelial cells, keratocytes and endothelial cells with the use of MAbs specific for the loop domain of Bcl-2. TUNEL-labeled surface epithelial cells did not stain with MAbs to Bcl-2, suggesting degradation or epitope masking perhaps by specific phosphorylation of the loop domain during apoptosis. Taken together, these findings suggest that Bcl-2 protein may play a critical role in modulating apoptotic cell desquamation in the human corneal epithelium.


Assuntos
Proteínas de Transporte/metabolismo , Córnea/metabolismo , Proteínas de Membrana , Proteínas Proto-Oncogênicas , Idoso , Análise de Variância , Apoptose/fisiologia , Proteínas Reguladoras de Apoptose , Proteína 11 Semelhante a Bcl-2 , Western Blotting , Substância Própria/metabolismo , Endotélio Corneano/metabolismo , Epitélio Corneano/metabolismo , Humanos , Imuno-Histoquímica/métodos , Marcação In Situ das Extremidades Cortadas , Pessoa de Meia-Idade
10.
Ophthalmology ; 108(7): 1279-88, 2001 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-11425688

RESUMO

OBJECTIVE: To determine the effects of lens type and oxygen transmissibility on human corneal epithelium during daily lens wear (DW). DESIGN: Prospective, randomized, double-masked, single-center, parallel treatment groups clinical trial. PARTICIPANTS: Two hundred forty-six patients fitted with: (1) high oxygen-transmissible soft lenses (n = 36), (2) hyper oxygen-transmissible soft lenses (n = 135), and (3) hyper oxygen-transmissible rigid gas-permeable (RGP) lenses (n = 75). INTERVENTION: Irrigation chamber to collect exfoliated epithelial surface cells, confocal microscopy, and tear collection at baseline, 2 weeks, and 4 weeks of DW. MAIN OUTCOME MEASURES: (1) Pseudomonas aeruginosa (PA) binding to exfoliated corneal epithelial surface cells, (2) central epithelial thickness, (3) superficial epithelial cell area, (4) epithelial surface cell exfoliation, and (5) tear lactate dehydrogenase (LDH). RESULTS: Four weeks of DW with the high oxygen-transmissible soft lens significantly increased PA binding from baseline 6.55 +/- 3.01 to 8.75 +/- 3.05 bacteria per epithelial cell (P < 0.01). By contrast, hyper oxygen-transmissible soft lens wear increased binding significantly less (6.13 +/- 2.45 to 7.62 +/- 3.06; P < 0.01), whereas hyper oxygen-transmissible RGP lens wear demonstrated no significant changes (5.91 +/- 2.40 to 6.13 +/- 2.17; P = 0.533). No significant change in central epithelial thickness was found after 4 weeks of DW in either soft lens; however, the epithelial thickness decreased by 9.8% (P < 0.001) with RGP lens wear. Epithelial cell surface area increased 3.3% and 4.1% with the high and hyper oxygen-transmissible soft lenses, respectively, and 10.5% with the hyper oxygen-transmissible RGP lens (P < 0.001). Epithelial desquamation significantly decreased in all groups (P < 0.001). Tear LDH levels increased for all test lenses (P < 0.001). CONCLUSIONS: Increased PA binding induced by wear of a conventional soft lens material is significantly greater than that induced by the new hyper oxygen-transmissible soft silicone hydrogel lens during DW. However, both soft materials showed significant increases in PA binding as compared with baseline controls. By contrast, hyper oxygen-transmissible RGP lens DW did not increase PA binding significantly. Taken together, these findings suggest for the first time both an oxygen effect as well as a difference between soft and rigid lens types on PA binding in DW.


Assuntos
Aderência Bacteriana , Lentes de Contato Hidrofílicas , Células Epiteliais/microbiologia , Epitélio Corneano/fisiologia , L-Lactato Desidrogenase/metabolismo , Pseudomonas aeruginosa/fisiologia , Lágrimas/enzimologia , Adulto , Córnea/citologia , Método Duplo-Cego , Feminino , Humanos , Masculino , Microscopia Confocal , Pessoa de Meia-Idade , Oxigênio/metabolismo , Estudos Prospectivos , Ajuste de Prótese
11.
Toxicol Pathol ; 29(2): 187-99, 2001.
Artigo em Inglês | MEDLINE | ID: mdl-11421486

RESUMO

The ocular irritation responses to 11 different surfactants and two concentrations of acetic acid and sodium hydroxide have been shown to depend on the extent of initial injury, despite marked differences in the processes leading to tissue damage. The purpose of these studies was to determine the extent to which this fundamental relationship applies to other nonsurfactants. Ten microl of acetone (ACT). cyclohexanol (CY), parafluoroaniline (PF), or 37% formaldehyde (FA) was directly applied to the cornea of the right eye of each rabbit. Eyes and eyelids were macroscopically scored for signs of irritation beginning 3 hours after dosing and periodically until recovery or 35 days. Tissues were obtained for light microscopic examination after 3 hours and on days 1, 3, and 35. Initial corneal injury was characterized quantitatively at 3 hours and I day using in vivo confocal microscopy (CM) and by postmortem quantitation of dead corneal epithelial cells and keratocytes using a Live Dead Assay (L/D, Molecular Probes) and scanning laser CM. Corneal changes over time were characterized quantitatively using in vivo CM performed at 3 hours and 1, 3, 7, 14, and 35 days. The changes with ACT were consistent with mild irritation. Corneal injury was limited to the epithelium and superficial stroma, with the mean normalized depth of injury (NDI) being less than 10% with the majority of regions showing no stromal injury. Changes with CY and PF were consistent with moderate to severe irritation, and FA caused severe irritation. Specifically, corneal injury by CY and PF tended to involve the epithelium and anterior stroma, with the mean NDI being 10.4% to 23.8%, while injury with FA involved the epithelium, deep stroma, and at times the endothelium. Interestingly, with FA significantly less injury was observed at 3 hours with a dramatic increase in injury observed at 1 day and thereafter. In conclusion, these results continue to support and extend our hypothesis that ocular irritation is principally defined by the extent of initial injury despite clear differences in the means by which irritants cause tissue damage. We believe this approach can be applied to developing alternative assays based on injury to ex vivo eyes or injury to an in vitro corneal equivalent system.


Assuntos
Acetona/toxicidade , Compostos de Anilina/toxicidade , Doenças da Córnea/induzido quimicamente , Cicloexanóis/toxicidade , Formaldeído/toxicidade , Irritantes/toxicidade , Acetona/administração & dosagem , Administração Tópica , Compostos de Anilina/administração & dosagem , Alternativas aos Testes com Animais , Animais , Morte Celular , Túnica Conjuntiva/efeitos dos fármacos , Túnica Conjuntiva/patologia , Doenças da Córnea/patologia , Substância Própria/efeitos dos fármacos , Substância Própria/patologia , Cicloexanóis/administração & dosagem , Epitélio Corneano/efeitos dos fármacos , Epitélio Corneano/patologia , Pálpebras/efeitos dos fármacos , Pálpebras/patologia , Feminino , Fluoretos/toxicidade , Formaldeído/administração & dosagem , Irritantes/administração & dosagem , Masculino , Microscopia Confocal , Coelhos , Fatores de Tempo , Testes de Toxicidade , Cicatrização
12.
CLAO J ; 27(2): 84-8, 2001 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-11352454

RESUMO

PURPOSE: To determine satisfaction among patients treated with laser-in-situ-keratomileusis (LASIK) for various degrees of myopia (-0.75 D to -16.00 D) and myopic astigmatism (+0.50 D to +4.50 D) and assess factors which may affect satisfaction. METHODS: One-hundred seventy-four consecutive patients treated with LASIK between November 1, 1997 and October 31, 1998 were surveyed. Charts were reviewed to collect refractive data. RESULTS: Eighty-three patients (163 eyes) returned surveys for a response rate of 53%. Of the responders, 55% were female, the average age was 39.6 years (range 21-59), the mean preoperative sphere was -6.36 +/- 0.23 D, cylinder +0.94 +/- 0.07 D, and spherical equivalent-5.89 +/- 0.23 D. Ninety-six percent of eyes enjoyed freedom from corrective lenses following LASIK. Twenty-nine percent reported reduced night vision clarity following LASIK and 27% noted more eye dryness following LASIK. Overall, 84.8% were at least "very pleased" with the results of the procedure and 97% indicated that they would decide again to have LASIK. Uncorrected visual acuity and lower preoperative cylinder correlated positively with satisfaction, while increased postoperative dry eyes correlated negatively with satisfaction. CONCLUSIONS: This study demonstrates a very high level of patient satisfaction following excimer laser treatment for myopia and myopic astigmatism. A great deal of literature has evaluated objective outcomes of LASIK, but this is one of few studies to examine patient satisfaction.


Assuntos
Córnea/cirurgia , Ceratomileuse Assistida por Excimer Laser In Situ , Miopia/cirurgia , Satisfação do Paciente/estatística & dados numéricos , Adulto , Feminino , Ofuscação , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias , Inquéritos e Questionários , Acuidade Visual
13.
J Cataract Refract Surg ; 27(3): 396-403, 2001 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-11255051

RESUMO

PURPOSE: To compare the axis and magnitude of surgically induced refractive astigmatism (SIA) after hyperopic and myopic photorefractive keratectomy (PRK). SETTING: Department of Ophthalmology, University of Texas Southwestern Medical Center, Dallas, Texas, USA. METHODS: In this single-center retrospective study, the VISX Star S2 excimer laser was used to create a peripheral annular ablation profile to correct spherical hyperopia in 23 eyes of 16 consecutive patients. Attempted corrections ranged from +0.50 diopter (D) to +4.25 D with 0 to 1.00 D of astigmatism. The same laser was used to create a central ablation profile to correct spherical myopia in 25 eyes of 17 consecutive patients. Attempted corrections ranged from -2.25 to -6.50 D with 0 to 1.00 D of astigmatism. The absolute change in refractive astigmatism was calculated by taking the difference in magnitudes of astigmatism before and after laser treatment without regard to axis. Axis and magnitude of SIA were analyzed by vector differences. Magnitudes were compared using the Student t test, and axial shifts were compared using the chi-square test. All patients were followed for a minimum of 6 months. RESULTS: The mean changes in absolute astigmatism were 0.29 +/- 0.28 D at 3 months and 0.34 +/- 0.29 D at 6 months after hyperopic PRK and 0.40 +/- 0.35 D at 3 months and 0.39 +/- 0.36 D at 6 months after myopic PRK. The mean vectoral magnitudes were 0.49 +/- 0.29 at 3 months and 0.52 +/- 0.25 at 6 months after hyperopic PRK and 0.48 +/- 0.39 at 3 months and 0.44 +/- 0.38 at 6 months after myopic PRK. The mean values for SIA (the centroid) were 0.10 +/- 0.57 D x 113 degrees at 3 months and 0.15 +/- 0.57 D x 131 degrees at 6 months after hyperopic PRK and 0.04 +/- 0.63 D x 160 degrees at 3 months and 0.08 +/- 0.58 D x 171 degrees at 6 months after myopic PRK. There was no statistically significant difference between the 2 groups in vectoral axis or magnitude of SIA. CONCLUSION: Surgically induced astigmatism after hyperopic PRK was comparable to astigmatism induced by myopic PRK. A peripheral annular ablation for hyperopic correction, similar to a central ablation in myopic PRK, did not appear to result in uneven corneal healing causing astigmatism.


Assuntos
Astigmatismo/etiologia , Córnea/cirurgia , Hiperopia/cirurgia , Miopia/cirurgia , Ceratectomia Fotorrefrativa/efeitos adversos , Astigmatismo/fisiopatologia , Córnea/fisiopatologia , Seguimentos , Humanos , Lasers de Excimer , Estudos Retrospectivos , Fatores de Tempo
14.
Exp Eye Res ; 72(4): 455-66, 2001 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-11273673

RESUMO

Corneal wound healing fibroblasts (myofibroblasts) develop a muscle-like contractile apparatus composed of prominent microfilament bundles (stress fibers) and express alpha-smooth muscle actin (alpha-SMA). In this study, gelsolin, an actin filament-severing protein, was overexpressed in a alpha-SMA-expressing corneal myofibroblast cell line (TRK43) to assess whether intact stress fibers are required for in vitro matrix organization and wound contraction. Stably integrated gelsolin was introduced by electroporation of an expression construct (pREPCG8) into cultured cells. Thirty-seven clones were isolated with half of the clones showing a fibroblastic phenotype while the remaining half appeared epithelioid. One fibroblastic clone, GS56, and one epithelioid clone, GS44, were selected for detailed characterization. The GS56 cells appeared highly elongated and spindle-shaped and had prominent stress fibers and focal adhesions. GS44 cells showed disruption of stress fibers and a cortical f-actin organization as well as the down regulation of alpha-SMA expression by immunocytochemistry and Western blotting. Both phenotypes showed enhanced gelsolin expression; however, fractionation of cell extracts demonstrated differences in the subcellular distribution of gelsolin with GS44 cells having markedly reduced and GS56 cells having markedly increased cytoskeletal gelsolin. In an in vitro wound contraction assay, epithelioid GS44 cells showed a significantly impaired ability to contract a collagen matrix compared to that of TRK43 cells, CT9 or GS56 transfectants. Loss of stress fibers in GS44 cells also correlated with enhanced cell motility. Together, these results demonstrate that the ability to form microfilament bundles or stress fibers is required for matrix organization and contraction by corneal myofibroblasts. Although no clear explanation is available, we suspect that differences in gene insertion of the gelsolin overexpression vector may have led to differential intercellular localization of gelsolin and its effect on stress fiber formation in the two cell lines.


Assuntos
Córnea/fisiologia , Fibroblastos/metabolismo , Fibras de Estresse/fisiologia , Cicatrização/fisiologia , Animais , Western Blotting , Movimento Celular/fisiologia , Células Cultivadas , Córnea/citologia , Citoesqueleto/metabolismo , Regulação para Baixo , Eletroporação , Matriz Extracelular/metabolismo , Gelsolina/metabolismo , Coelhos
15.
Cornea ; 20(1): 73-80, 2001 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-11189009

RESUMO

PURPOSE: To evaluate for the first time cell junctional protein organization in proliferating corneal endothelial cells during in vivo wound healing. METHODS: A total of 16 cats (32 eyes) were used in this study. A single 3-mm diameter (n = 24) or 1- to 2-mm diameter (n = 8) scrape injury was created in the central corneal endothelium of each eye. Twenty-four, 48, 72 hours or 5 days after scrape injury, eyes were collected for in situ double- or triple-labeling with phalloidin, anti-ZO-1, alpha-catenin, beta-catenin, and MIB-1 (monoclonal antibody to Ki67, a marker for actively cycling cells) and were imaged using confocal laser microscopy. RESULTS: In 3-mm diameter injuries, endothelial cells completely resurfaced the wound 48 to 72 hours after scrape injury; smaller wounds resurfaced by 48 hours. Ki67 staining was negative 24 hours after scrape injury in all cases. Ki67-positive cells were observed in the central region of the wounds after 48 and 72 hours, and mitotic figures and pairs of postmitotic cells were observed. On day 5, Ki67-positive cells were rarely detected, and no mitotic figures were observed. In the wound area, a significant increase in cell area and a reduction in hexagonality were observed in cycling cells after 48 and 72 hours. Normal apical, pericellular staining of f-actin, ZO-1, alpha-catenin, and beta-catenin was partially maintained at all times during wound healing of small and large wounds. Double-labeling confirmed that these proteins were also present along the apical cell border in Ki67-positive cells. CONCLUSIONS: After in vivo scrape injury, proliferation is limited temporally and spatially to spreading endothelial cells within the wound. Cell junctional connections appear to be maintained in actively cycling cells during healing.


Assuntos
Actinas/metabolismo , Caderinas/metabolismo , Endotélio Corneano/metabolismo , Traumatismos Oculares/metabolismo , Proteínas de Membrana/metabolismo , Fosfoproteínas/metabolismo , Transativadores , Cicatrização , Animais , Biomarcadores , Gatos , Divisão Celular , Proteínas do Citoesqueleto/metabolismo , Endotélio Corneano/lesões , Endotélio Corneano/ultraestrutura , Traumatismos Oculares/patologia , Antígeno Ki-67/imunologia , Antígeno Ki-67/metabolismo , Microscopia Confocal , Proteína da Zônula de Oclusão-1 , alfa Catenina , beta Catenina
16.
Ophthalmology ; 108(1): 112-20, 2001 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-11150274

RESUMO

PURPOSE: To determine differences of corneal wound healing and haze after photorefractive keratectomy (PRK) using either mechanical epithelial debridement or laser-scrape epithelial removal in human subjects. DESIGN: A 6-month randomized, masked, prospective, paired-eye clinical study. PARTICIPANTS: Twenty eyes in 10 myopic patients treated between March 1999 and May 1999. INTERVENTION: Photorefractive keratectomy treatments with two different epithelial removal techniques. Continuous z-scan of confocal image, termed confocal microscopy through focusing (CMTF), was performed before surgery and at 3 weeks, 6 weeks, 3 months, and 6 months after surgery. MAIN OUTCOMES MEASURES: Epithelial and stromal thickness measurement, achieved stromal ablation depth, and objective assessment of corneal light-backscattering (corneal haze) were obtained from digital image analysis of the CMTF scans. Manifest refraction was also measured. Student's paired t test or two-way repeated-measures analysis of variance after rank transformation were performed to evaluate statistical differences between groups. RESULTS: Comparison of the mean posttreatment spherical equivalent between the two techniques showed no statistically significant difference. In preoperative corneas, mean epithelial thickness was 50.08+/-3.70 microm in the mechanical debridement group and 50.49+/-4.01 microm in laser-scrape group (not significant). For both groups, the epithelium was significantly thinner at 3 weeks, but returned to preoperative values by 6 months, with no difference between groups. Planned stromal ablation depth by PRK was 59.38+/-11.48 microm (39-73 microm; n = 8) in the mechanical group and 57.75 +/- 7.21 microm (48-70 microm; n = 8) in the laser-scrape group. Achieved stromal ablation depth was not significantly different between the two groups. Most importantly, in both groups CMTF-measured corneal haze increased significantly after surgery, peaked at 3 months, and then decreased at 6 months, with no significant difference between groups. (Power = 0.96). CONCLUSIONS: There is no significant difference in the corneal wound healing response between mechanical epithelial debridement versus laser-scrape technique in human myopic eyes undergoing PRK.


Assuntos
Desbridamento/métodos , Epitélio Corneano/cirurgia , Ofuscação , Terapia a Laser/métodos , Miopia/cirurgia , Ceratectomia Fotorrefrativa , Adulto , Substância Própria/patologia , Método Duplo-Cego , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Lasers de Excimer , Masculino , Microscopia Confocal , Estudos Prospectivos , Refração Ocular , Cicatrização
17.
Toxicol Pathol ; 28(5): 668-78, 2000.
Artigo em Inglês | MEDLINE | ID: mdl-11026602

RESUMO

Defining the extent of initial injury has proven to be a useful basis for differentiating the ocular irritation potential of surfactants; however, the applicability of this method to other types of irritants has not been demonstrated. In the following studies we characterized the extent of corneal injury following exposure to different concentrations of acetic acid and sodium hydroxide (NaOH) in the rabbit low-volume eye test. Groups of rabbits received 3% acetic acid, 10% acetic acid, 2% NaOH, or 8% NaOH and were evaluated in vivo by macroscopic and in vivo confocal microscopic examination and postmortem using a live/dead staining kit and scanning laser confocal microscopic examination. Quantitative assessment of macroscopic scores, corneal surface epithelial cell size, corneal epithelial thickness, corneal thickness, depth of stromal injury, corneal light scattering (confocal microscopy through focusing, CMTF), and number of dead cells was conducted at various times, including the following: at 3 hours and at 1, 3, 7, 14, and 35 days. Based on macroscopic scores, the order of ocular irritancy potential was 3% acetic acid < 2% NaOH < 10% acetic acid < 8% NaOH. Evaluation of the quantitative in vivo and postmortem microscopic live/dead data revealed a slight decrease in epithelial thickness and an increase in dead epithelial cell numbers with 3% acetic acid. With 2% NaOH, significant focal changes in epithelial cell size, epithelial thickness, corneal thickness, and number of dead surface epithelial cells occurred at 3 hours and at 1 day, with injury to only a very small number of corneal stromal keratocytes, despite the presence of epithelial denudation. Changes with 10% acetic acid were similar to those noted with 2% NaOH at 3 hours and 1 day, but these changes were more diffuse and included stromal injury to a depth of 7.2 +/- 9.3% of the corneal thickness, with significant numbers of dead keratocytes. Eight percent NaOH, on the other hand, caused focally extensive injury that averaged 26.3 +/- 18.4% of the corneal thickness at 1 day, with significant light scattering from the cornea, which did not return to normal by 35 days postinjury. Overall, these data indicate that ocular irritation as a result of acetic acid and NaOH was associated with changes similar to those observed with surfactants (ie, slight irritants damage the corneal epithelium, mild and moderate irritants damage the corneal epithelium and anterior stromal cells, and severe irritants damage the corneal epithelium and deep stroma). To our knowledge, this is the first time that the ocular irritation potential for different types of materials (acid/alkali, surfactants) has been shown to be primarily dependent on the initial area and depth of injury.


Assuntos
Ácido Acético/toxicidade , Doenças da Córnea/induzido quimicamente , Topografia da Córnea/métodos , Microscopia Confocal/métodos , Hidróxido de Sódio/toxicidade , Ácido Acético/administração & dosagem , Doença Aguda , Animais , Morte Celular , Tamanho Celular , Córnea/efeitos dos fármacos , Córnea/patologia , Doenças da Córnea/patologia , Substância Própria/efeitos dos fármacos , Substância Própria/patologia , Epitélio Corneano/efeitos dos fármacos , Epitélio Corneano/patologia , Olho/efeitos dos fármacos , Olho/patologia , Coelhos , Hidróxido de Sódio/administração & dosagem , Fatores de Tempo
18.
Cornea ; 19(5): 712-22, 2000 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-11009323

RESUMO

PURPOSE: To identify, characterize, and illustrate the most important past and future potential contributions of specular, confocal, and ultrasound biomicroscopy to clinical diagnosis and research applications in the cornea from the past 25 years. METHODS: Specular microscopy, in vivo tandem scanning confocal microscopy (TSCM), scanning slit confocal microscopy (SSCM), and high-frequency ultrasound biomicroscopy are examined. RESULTS AND CONCLUSIONS: This review demonstrates the abilities and limitations of three powerful new in vivo imaging modalities to resolve the cellular and structural layers of the cornea temporally and spatially in three or four dimensions, (x, y, z, t). Clinical pathological processes such as inflammation. infection, wound healing, toxicity, embryonic development, differentiation, and disease, which previously could be studied only under static ex vivo conditions, can now be dynamically evaluated over time. Thus, with continued development and application in vivo, noninvasive microscopic techniques should provide exciting new insights into understanding the structure and function of not only the eye, but also other multicellular organ systems in health and disease. These new imaging paradigms are in the first rank of advances in medical science in the past quarter century.


Assuntos
Córnea/diagnóstico por imagem , Doenças da Córnea/diagnóstico , Técnicas de Diagnóstico Oftalmológico/tendências , Microscopia Confocal/tendências , Córnea/ultraestrutura , Humanos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Ultrassonografia
19.
Invest Ophthalmol Vis Sci ; 41(10): 2945-53, 2000 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-10967049

RESUMO

PURPOSE: In vivo confocal microscopy through focusing (CMTF) can provide a 3-D stack of high-resolution corneal images and allows objective measurements of corneal sublayer thickness and backscattering. However, current systems require time-consuming off-line image processing and analysis on multiple software platforms. Furthermore, there is a trade off between the CMTF speed and measurement precision. The purpose of this study was to develop a novel on-line system for in vivo corneal imaging and analysis that overcomes these limitations. METHODS: A tandem scanning confocal microscope (TSCM) was used for corneal imaging. The TSCM video camera was interfaced directly to a PC image acquisition board to implement real-time digitization. Software was developed to allow in vivo 2-D imaging, CMTF image acquisition, interactive 3-D reconstruction, and analysis of CMTF data to be performed on line in a single user-friendly environment. A procedure was also incorporated to separate the odd/even video fields, thereby doubling the CMTF sampling rate and theoretically improving the precision of CMTF thickness measurements by a factor of two. RESULTS: In vivo corneal examinations of a normal human and a photorefractive keratectomy patient are presented to demonstrate the capabilities of the new system. Improvements in the convenience, speed, and functionality of in vivo CMTF image acquisition, display, and analysis are demonstrated. CONCLUSIONS: This is the first full-featured software package designed for in vivo TSCM imaging of the cornea, which performs both 2-D and 3-D image acquisition, display, and processing as well as CMTF analysis. The use of a PC platform and incorporation of easy to use, on line, and interactive features should help to improve the clinical utility of this technology.


Assuntos
Córnea/citologia , Processamento de Imagem Assistida por Computador/métodos , Microscopia Confocal/métodos , Sistemas On-Line , Humanos
20.
Ophthalmology ; 107(7): 1235-45, 2000 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-10889092

RESUMO

PURPOSE: To evaluate the mechanism(s) producing refractive instability and corneal haze development after photorefractive keratectomy (PRK). DESIGN: Prospective, nonrandomized, comparative case series, self-controlled. PARTICIPANTS: Seventeen eyes of 17 patients with low- to moderate-grade myopia (-2.88 to -9.13 diopters [D]) were included. METHODS: Surgical intervention was a standardized, 6-mm diameter PRK procedure using the Meditec MEL 60 excimer laser (Aesculap-Meditec, Heroldsberg, Germany). The photoablation center was evaluated before surgery and at 1, 3, 6, 9, and 12 months after PRK using rapid, continuous z-scans of confocal images, termed confocal microscopy through focusing (CMTF). MAIN OUTCOME MEASURES: Simultaneous epithelial and stromal thickness analysis and objective assessment of corneal light backscattering were obtained from digital image analysis of the CMTF scans. Corneal reinnervation and anterior stromal keratocyte density and wound healing morphologic features were evaluated on high resolution, in vivo confocal images. Manifest refraction was measured and corneal clarity was graded by slit-lamp biomicroscopy. RESULTS: Epithelial thickness averaged 45+/-10 microm at 1 month, 50+/-8 microm at 3 months, and 52+/-6 microm at 12 months after PRK, as compared with 51+/-4 microm before surgery, demonstrating complete restoration of the preoperative thickness without compensatory hyperplasia. Interestingly, epithelial rethickening had no significant correlation with refractive regression. By contrast, stromal regrowth (from 1-12 months) averaged 6+/-12 microm (range, 27 microm thinning-22 microm rethickening) and correlated closely (r = 0.84, P<0.001) with changes in refraction that averaged 0.84+/-1.23 D, ranging from -1.63 D (hyperopic shift) to +3.38 D (myopic regression). Stromal rethickening increased proportionally with the actual photoablation depth (r = 0.63, P<0.01); linear regression analysis suggested an average regrowth rate of 8% per year for the entire study group. Stromal rethickening was not associated with CMTF haze development over time, suggesting that haze and regression were caused by two independent wound healing mechanisms. In agreement with these findings, all "hazy" corneas showed increased numbers of anterior stromal wound healing keratocytes with increased reflectivity of both nuclei and cell bodies, suggesting that cellular-based reflections, as opposed to extracellular matrix deposition, are the major origin of increased corneal light scattering after PRK. CONCLUSIONS: Taken together, these data indicate that keratocyte-mediated regrowth of the photoablated stroma appears to be the main cause of myopic regression in humans treated with a 6-mm diameter PRK, whereas hyperopic shifts appear to be a direct consequence of stromal thinning. By contrast, the corneal epithelium appeared to restore its preoperative thickness without contributing significantly to the refractive changes after PRK. Finally, this study also provides strong evidence that the development of haze after PRK is directly associated with increased cellular reflectivity from high numbers of wound healing keratocytes.


Assuntos
Substância Própria/patologia , Miopia/etiologia , Ceratectomia Fotorrefrativa/efeitos adversos , Transtornos da Visão/etiologia , Cicatrização , Adulto , Contagem de Células , Córnea/inervação , Substância Própria/cirurgia , Epitélio Corneano/patologia , Feminino , Fibroblastos/patologia , Humanos , Lasers de Excimer , Masculino , Microscopia Confocal , Pessoa de Meia-Idade , Miopia/patologia , Miopia/cirurgia , Regeneração Nervosa/fisiologia , Nervo Oftálmico/fisiologia , Estudos Prospectivos , Recidiva , Transtornos da Visão/patologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...