Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Phys Med Biol ; 64(12): 125023, 2019 06 21.
Artigo em Inglês | MEDLINE | ID: mdl-31071694

RESUMO

Gating response times of monitoring system/LINAC combinations for gated radiotherapy treatments are notoriously difficult to measure. This difficulty may reflect why the incorporation of gating response times is not thoroughly considered when creating treatment margins for gated radiotherapy treatments, however ignoring the effect of gating response time could lead to significant treatment inaccuracies. This study shows a methodology which measured gating response times for AlignRT/Varian Truebeam combination which appears to be applicable to any surface guided monitoring/Linac combination as well as those combinations which incorporate extended lag times (>200 ms). Beam on lag time appears to be measurably greater than beam off lag time. Although these gating response times are slower than other gating systems on the market, the advantages surface guided radiotherapy (SGRT) could potentially provide for treatment accuracy is discussed as well as demonstrating the lack of guidance regarding SGRT with respect to gated treatments.


Assuntos
Movimento , Aceleradores de Partículas/instrumentação , Imagens de Fantasmas , Garantia da Qualidade dos Cuidados de Saúde/normas , Planejamento da Radioterapia Assistida por Computador/métodos , Técnicas de Imagem de Sincronização Respiratória/instrumentação , Técnicas de Imagem de Sincronização Respiratória/métodos , Humanos , Dosagem Radioterapêutica , Tempo de Reação , Respiração
2.
Nucl Med Commun ; 27(12): 939-44, 2006 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-17088678

RESUMO

BACKGROUND: In the semi-quantitative assessment of DaTSCAN images, it has been suggested that the ratio of tracer accumulation in the putamen to that in the caudate nucleus may be helpful and could allow parkinsonian syndromes progression to be assessed. Separation of ratio values has been reported when early Parkinson's disease is compared with essential tremor. The separation is lost, however, when the Parkinson's disease is not early stage. OBJECTIVES: To evaluate whether a two-stage analysis can differentiate between parkinsonian syndromes, of various stages, and essential tremor, and whether such a two-stage analysis can be undertaken in a single step using artificial neural networks (ANNs). METHODS: Data from 18 patients were analysed. Quantification was undertaken by manually drawing irregular regions of interest (ROIs): over each caudate nucleus and putamen and over an occipital cortex area near the posterior edge of the brain. A two-stage analysis was undertaken and was repeated, in a single step, using an ANN. RESULTS: The first stage, of the two-stage analysis, identified 12 patients with non-early parkinsonian syndromes. The remaining six patients were then successfully classified into early parkinsonian syndromes and essential tremor. The ANN analysis successfully discriminated parkinsonian syndromes from essential tremor, in all patients, in a single step. CONCLUSIONS: The two-stage process provides a method for classifying early disease without being compromised by the noise from non-early disease. The results of the single stage ANN analysis were very definite and it may be considered to have potential in the quantification of DaTSCAN images for clinical use.


Assuntos
Tremor Essencial/diagnóstico por imagem , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Redes Neurais de Computação , Doença de Parkinson/diagnóstico por imagem , Reconhecimento Automatizado de Padrão/métodos , Tropanos , Adulto , Idoso , Idoso de 80 Anos ou mais , Análise por Conglomerados , Diagnóstico Diferencial , Feminino , Humanos , Aumento da Imagem/instrumentação , Interpretação de Imagem Assistida por Computador/instrumentação , Masculino , Pessoa de Meia-Idade , Compostos Radiofarmacêuticos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Síndrome , Tomografia Computadorizada de Emissão de Fóton Único/instrumentação , Tomografia Computadorizada de Emissão de Fóton Único/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA