Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
3.
Graefes Arch Clin Exp Ophthalmol ; 260(9): 2991-3000, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35254510

RESUMO

INTRODUCTION: Uveitic glaucoma remains challenging despite medical and surgical advancements and can potentially lead to blindness if left uncontrolled. Conservative alternatives as well as microinvasive surgeries can postpone the necessity of a highly invasive intervention. However, such procedures are still necessary to treat some refractive glaucoma cases. Since previous studies have reported excellent results following the primary implantation of glaucoma drainage devices, it was our study's aim to evaluate long-term results following a Baerveldt 250 implantation in highly complex and surgically burdened uveitic glaucoma eyes (UG) and compare these to a similar population suffering from other forms of glaucoma (OFG). MATERIAL AND METHODS: We performed a retrospective analysis of all eyes (UG vs. OFG) following a Baerveldt 250 implant between 2013 and 2019. Efficacy parameters as well as post-operative complication data were extracted from our electronic data system for statistical analysis. RESULTS: A total of 62 eyes were included in our study (24 UG and 38 OFG). UG baseline mean IOP was 35.04 mmHg (± 11.85 mmHg) with 3.08 (± 1.13) topical agents, and OFG was 32.63 mmHg (± 7.74 mmHg) with 2.68 (± 1.28) topical agents. A majority of eyes also required systemic acetazolamide (UG: 79% OFG: 87%) and had undergone at least one glaucoma-related operation prior to the Baerveldt 250 implant ((UG: 1.21 (± 0.66)), OFG: 1.74 (± 1.33)). At the median follow-up period (UG 592, OFG 764 days), 52.5%/32.5% of UG/OFG cases showed qualified success (IOP below 21 mmHg with either topical or/and systemic medication), 15%/30% no longer required topical medication, and 47.5% /47.5% were free of acetazolamide systemically. Moreover, 75%/72.5% of eyes experienced no further pressure-related surgical event. Although sight-threatening complications such as corneal and macular edema were reported in both groups, most either maintained or improved their visual acuity at the last follow-up (58.33%/57.89%). CONCLUSION: The Baerveldt 250 implant is shown to be both effective and safe for advanced glaucoma cases in uveitis and other forms. No further glaucoma-related surgery is required in the majority of eyes in either group within a follow-up period of almost 2 years. Despite sight-threatening complications such as macular and corneal edema, visual acuity can be either maintained or improved in most eyes.


Assuntos
Implantes para Drenagem de Glaucoma , Glaucoma , Uveíte , Acetazolamida , Seguimentos , Humanos , Pressão Intraocular , Complicações Pós-Operatórias , Implantação de Prótese , Estudos Retrospectivos , Resultado do Tratamento
4.
BMC Ophthalmol ; 21(1): 31, 2021 Jan 12.
Artigo em Inglês | MEDLINE | ID: mdl-33430821

RESUMO

BACKGROUND: Precise optic disc size measurements based on anatomically exact disc margins are fundamental for a correct assessment of glaucoma suspects. Computerized imaging techniques, such as confocal-scanning-laser-tomography (CSLT), which applies operator defined boundaries and optical-coherence-tomography (OCT), which incorporates an alternative detectable landmark (Bruch's-membrane-opening (BMO)), have simplified the planimetry of the optic disc and BMO-area, respectively. This study's objectives are to compare both modalities for area and to define a threshold for macro-BMO using BMO-OCT. METHODS: Retrospectively, patients that simultaneously received CSLT and BMO-OCT scans were included. Their images were correlated and agreement was determined using Bland-Altman-analysis. The diagnostic power of a macro-BMO threshold using OCT was derived after creating a receiver-operating-characteristics-curve using the well-established analogous CSLT threshold (2.43 mm2). RESULTS: Our study included 373 eyes with a median optic disc area by CSLT/ BMO-area by OCT of 2.56 mm2 and 2.19 mm2 respectively. The Bland-Altman-analysis revealed a systematic deviation with a diverging tendency with increasing area, which enabled the creation of the following mathematical relation: disc-area (CSLT)*0.73 + 0.3 = BMO-area (OCT). BMO-area of 2.19 mm2 showed the best diagnostic power for identifying macro-BMOs using OCT (sensitivity: 75%, specificity: 86%). CONCLUSIONS: Area measurements (CSLT optic disc area vs. BMO-area by OCT) showed a systematic deviation with a divergent tendency with increasing size. Our mathematical equation offers an estimated comparison of these anatomically diverse entities. Considering BMO-OCT´ anatomical accuracy, the 2.19 mm2 threshold may improve discernment between glaucoma suspects and norm variants.


Assuntos
Disco Óptico , Tomografia de Coerência Óptica , Lâmina Basilar da Corioide/diagnóstico por imagem , Estudos Transversais , Humanos , Pressão Intraocular , Lasers , Fibras Nervosas , Disco Óptico/diagnóstico por imagem , Células Ganglionares da Retina , Estudos Retrospectivos , Campos Visuais
5.
World J Urol ; 36(3): 449-457, 2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-29307091

RESUMO

PURPOSE: To evaluate long-term efficacy and safety of low-pressure transurethral resection of the prostate for prostates < 70 cc (group 1) vs. > 70 cc (group 2). PATIENTS AND METHODS: In this study patients operated with monopolar TURP between 2009 and 2012 were evaluated retrospectively. During surgery a specially designed trocar (18 Fr) was placed suprapubically and connected to a suction pump to maintain stable low-pressure conditions. After sample size calculations, long-term follow-up was completed for 70 invited patients in each group up to 9/2015. RESULTS: Follow-up period was 57 vs. 56 months for group 1 and 2, respectively (p = 0.56). At baseline there was no significant difference in age, IPSS, peak flow, and post void residual (PVR). Mean prostate volume was 47 cc (15-65) vs. 100 cc (70-163). Mean operating time was 55.4 vs. 82.6 min (p = 0.00). Blood transfusion was necessary in 0.0 vs. 2.9% (p = 0.16), and 0.0 vs. 1.4% developed TUR syndrome (p = 0.32). At follow-up mean relative improvement in IPSS was 63 vs. 57% (p = 0.29), QoL 64 vs. 64% (p = 0.93), peak flow 139 vs. 130% (p = 0.85), and PVR 58 vs. 63% (p = 0.80). Long-term complications included recurring adenoma in 1.4 vs. 4.3% (p = 0.31), and stricture in 7.2 vs. 5.8% (p = 0.73). 1 patient in each group reported worsening incontinence symptoms. CONCLUSIONS: In terms of safety and efficacy, the aforementioned modality of standardized monopolar TURP using suprapubic suction was non-inferior for prostates > 70 cc compared to the same procedure for prostates < 70 cc. This technique is a potential low-cost alternative for clinics that cannot afford modern laser approaches. STUDY REGISTER NUMBER: DRKS00006527.


Assuntos
Eletrocirurgia/métodos , Sintomas do Trato Urinário Inferior/cirurgia , Complicações Pós-Operatórias/epidemiologia , Próstata/cirurgia , Hiperplasia Prostática/cirurgia , Sucção/métodos , Ressecção Transuretral da Próstata/métodos , Obstrução do Colo da Bexiga Urinária/cirurgia , Adenoma/complicações , Adenoma/cirurgia , Idoso , Idoso de 80 Anos ou mais , Seguimentos , Humanos , Sintomas do Trato Urinário Inferior/etiologia , Masculino , Pessoa de Meia-Idade , Recidiva Local de Neoplasia/cirurgia , Duração da Cirurgia , Tamanho do Órgão , Pressão , Estudos Prospectivos , Próstata/patologia , Hiperplasia Prostática/complicações , Neoplasias da Próstata/complicações , Neoplasias da Próstata/cirurgia , Estudos Retrospectivos , Resultado do Tratamento , Obstrução do Colo da Bexiga Urinária/etiologia , Incontinência Urinária/epidemiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...