Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Catheter Cardiovasc Interv ; 104(5): 1071-1078, 2024 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-39154247

RESUMO

BACKGROUND: Predictors of permanent pacemaker implantation (PPMI) after self-expanding transcatheter aortic valve implant (TAVI) were described. Is unknown if PPMI predictors remain in the era of high implants using the cusp overlap (COP). METHODS: Single-center, prospective, consecutive case series of patients undergoing self-expanding TAVI with the COP approach. The status of PPMI and other clinical events were ascertained at 30 days. RESULTS: A total of 261 patients were included (84% with Evolut, n = 219). Implant depth >4 mm was infrequent (13.8%). TAVI depth (OR 1.259; p = 0.005), first or second-degree auriculo-ventricular block (OR 3.406; p = 0.033), right-bundle (OR 15.477; p < 0.0001), and incomplete left-bundle branch block (OR 7.964; p = 0.036) were found to be independent predictors of PPMI. The risk of PPMI with deep implant and no electrical disturbances was 3%, and 0% with high implant and no prior electrical disturbances. Those who received PPMI had no statistically significant increased risk of death, myocardial infarction, stroke, bleeding events, or vascular complications at 30 days, but longer hospital stay (mean difference 1.43 days more, p = 0.003). CONCLUSIONS: Implant depth and prior conduction abnormalities remain the main predictors of PPMI using self-expanding TAVI in the COP era. Patients with high implants and no prior conduction abnormalities may be candidates for early discharge after uneventful self-expanding TAVI, while the rest may need inpatient monitoring regardless of achieving a high implant. The need for PPMI was associated with longer hospital stays.


Assuntos
Estenose da Valva Aórtica , Valva Aórtica , Estimulação Cardíaca Artificial , Próteses Valvulares Cardíacas , Marca-Passo Artificial , Desenho de Prótese , Substituição da Valva Aórtica Transcateter , Humanos , Masculino , Feminino , Estudos Prospectivos , Idoso de 80 Anos ou mais , Fatores de Risco , Idoso , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/mortalidade , Resultado do Tratamento , Valva Aórtica/cirurgia , Valva Aórtica/fisiopatologia , Valva Aórtica/diagnóstico por imagem , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/instrumentação , Substituição da Valva Aórtica Transcateter/mortalidade , Fatores de Tempo , Medição de Risco
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA