Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 18 de 18
Filtrar
1.
Int J Dermatol ; 48(10): 1091-5, 2009 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-19775402

RESUMO

BACKGROUND: Recently, there has been an increase in the incidence of cutaneous leishmaniasis (CL), which represents an important health problem. This increase may be related to the epidemiologic expansion of the infective agent and the increase in tourism in tropical areas. The difficulty in clinical diagnosis, mainly in areas in which CL is not the first consideration of local physicians, has intensified efforts to describe diagnostic tests, which should be specific, sensitive, and practical. Amongst the new tests described are those including nucleic acid amplification (polymerase chain reaction, PCR) and immunohistochemistry (IHC). METHODS: In this study, we evaluated the sensitivity of a PCR based on small subunit (SSU) ribosomal DNA, in comparison with IHC using Leishmania spp. antibodies, in biopsies embedded in paraffin. RESULT: The results indicated a total sensitivity of 96% (90.9% with PCR and 68.8% with IHC), showing the possibility of using paraffin-embedded biopsies to diagnose CL. CONCLUSION: We propose the use of the two tests together as a routine protocol for diagnosis. This would require the provision of local medical services to perform molecular biology techniques and adequate Leishmania antibodies.


Assuntos
Leishmaniose Cutânea/diagnóstico , Reação em Cadeia da Polimerase , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Brasil , Humanos , Imuno-Histoquímica , Pessoa de Meia-Idade , Inclusão em Parafina , Estudos Prospectivos , Sensibilidade e Especificidade , Adulto Jovem
3.
Bol. Oficina Sanit. Panam ; 113(4): 290-296, 1992.
Artigo em Espanhol | LILACS | ID: lil-370555

RESUMO

Se examino un total de 341 muestras de suero para detectar anticuerpos IgA, IgG e IgM anti-Leishmania mediante pruebas de inmunofluorescencia (IF) y ensayos inmunoenzimaticos (ELISA). En conjunto, 292 de los sueros pertenecian a pacientes con diagnosticos clinicos y parasitologicos de leishmaniasis cutanea (resultados positivos en la impronta de lesiones o en la prueba cutanea de Montenegro) y 49, a controles de la misma poblacion. Los índices de rendimiento diagnostico de los ELISA-IgG e IgM fueron de utilidad diagnostica y el valor predictivo positivo del ELISA-IgG fue de 94,6. . La especificidad de la prueba de IF-IgA fue notablemente alta (100. ), pero su sensibilidad fue muy baja


Assuntos
Ensaio de Imunoadsorção Enzimática , Leishmaniose/diagnóstico , Imunofluorescência/normas , Técnicas Imunoenzimáticas/normas , Brasil , Leishmaniose/epidemiologia , Sensibilidade e Especificidade
4.
Artigo | PAHO-IRIS | ID: phr-16432

RESUMO

Se examinó un total de 341 muestras de suero para detectar anticuerpos IgA, IgG e IgM anti-Leishmania mediante pruebas de inmunofluorescencia (IF) y ensayos inmunoenzimáticos (ELISA). En conjunto, 292 de los sueros pertenecían a pacientes con diagnósticos clínicos y parasitológicos de leishmaniasis cutánea (resultados positivos en la impronta de lesiones o en la prueba cutánea de Montenegro) y 49, a controles de la misma población. Los índices de rendimiento diagnóstico de los ELISA-IgG e IgM fueron de utilidad diagnóstica y el valor predictivo positivo del ELISA-IgG fue de 94,6. La especificidad de la prueba de IF-IgA fue notablemente alta (100), pero su sensibilidad fue muy baja.


Assuntos
Leishmaniose , Imunofluorescência , Técnicas Imunoenzimáticas , Ensaio de Imunoadsorção Enzimática , Sensibilidade e Especificidade , Brasil
5.
Artigo em Espanhol | PAHO | ID: pah-12461

RESUMO

Se examinó un total de 341 muestras de suero para detectar anticuerpos IgA, IgG e IgM anti-Leishmania mediante pruebas de inmunofluorescencia (IF) y ensayos inmunoenzimáticos (ELISA). En conjunto, 292 de los sueros pertenecían a pacientes con diagnósticos clínicos y parasitológicos de leishmaniasis cutánea (resultados positivos en la impronta de lesiones o en la prueba cutánea de Montenegro) y 49, a controles de la misma población. Los índices de rendimiento diagnóstico de los ELISA-IgG e IgM fueron de utilidad diagnóstica y el valor predictivo positivo del ELISA-IgG fue de 94,6


. La especificidad de la prueba de IF-IgA fue notablemente alta (100


), pero su sensibilidad fue muy baja


Assuntos
Leishmaniose/diagnóstico , Imunofluorescência/normas , Técnicas Imunoenzimáticas/normas , Ensaio de Imunoadsorção Enzimática/métodos , Sensibilidade e Especificidade , Leishmaniose/epidemiologia , Brasil
6.
Rev. Inst. Med. Trop. Säo Paulo ; 33(6): 503-8, nov.-dez. 1991. tab
Artigo em Inglês | LILACS | ID: lil-107775

RESUMO

O desempenho de um antigeno de promastigotas de L. major-like para o diagnostico sorologico de leishmaniose mucocutanea pelo teste de imunofluorescencia-IgG foi comparado com o desempenho de um antigeno de L. braziliensis braziliensis. Cada antigeno foi usado para testar 224 soros de etiologias como leishmaniose mucocutanea, micoses profundas, toxoplasmose, malaria, doenca de Chagas, leishmaniose visceral, fator anti-nucleo, esquistossomose mansonica, fator reumatoide e controles normais. A concordancia entre as respostas de cada antigeno foi grande: 77,2 por cento dos soros de leishmaniose mostraram resultado positivo para ambos os antigenos ou negativo, assim como 91,1 por cento dos soros controle negativos. Reacoes cruzadas ficaram restritas a doenca de Chagas, leishmaniose visceral, fator anti-nucleo e paracoccidioidomicose. A resposta quantitativa dos soros de leishmaniose e doenca de Chagas foi avaliada pelo metodo de regressao linear; embora a interseccao com o eixo y e o "slope" fossem diferentes para cada antigeno nenhum deles se mostrou melhor na evidenciacao de anticorpos anti-Leishmania. O antigeno de L. major-like mostrou-se melhor que o de L.b. braziliensis na evidenciacao de anticorpos em soros de doenca de Chagas.


Assuntos
Animais , Humanos , Antígenos de Protozoários/sangue , Imunoglobulina G/sangue , Leishmania braziliensis/imunologia , Leishmania tropica/imunologia , Leishmaniose Cutânea/diagnóstico , Imunofluorescência , Valor Preditivo dos Testes , Análise de Regressão
7.
Rev. Inst. Med. Trop. Säo Paulo ; 33(5): 385-9, set.-out. 1991. tab
Artigo em Inglês | LILACS | ID: lil-107758

RESUMO

Indices de desempenho diagnostico de sensibilidade, especificidade, valor preditivo positivo e eficiencia foram determinados nas reacoes de dot-ELISA e IgG-ELISA em 340 soros de leishmaniose mucocutanea. A sensibilidade do dot-ELISA foi significativamente mais baixa que a da IgG-ELISA e os dois testes tiveram indices de especificidade e de valor de predicao positivo da mesma magnitude. Setenta e oito soros tinham resultado negativo a reacao de dot-ELISA e resultado positivo ao IgG-ELISA. Quando os soros foram examinados de acordo com diferentes criterios de analise, quanto a esta discrepancia a estatistica kappa nao corroborou esta hipotese indicando que os dois testes concordavam substancialmente. Os resultados apresentados indicam que os indices de desempenho diagnostico obtidos em trabalho de campo onde haja boa caracterizacao das variaveis podem ser extrapolados a outros estudos populacionais desde que a doenca se mostre de alta prevalencia (devido a um vies de selecao ou nao) e nestas condicoes se pode esperar que os indices facam o diagnostico de doenca entre os resultados positivos ao teste.


Assuntos
Humanos , Ensaio de Imunoadsorção Enzimática/métodos , Leishmaniose Cutânea/diagnóstico , Leishmaniose Cutânea/epidemiologia , Valor Preditivo dos Testes , Prevalência
8.
Artigo em Inglês | PAHO | ID: pah-7331

RESUMO

A total of 341 sera were screened for anti-Leishmania IgA, IgG, and IgM antibodies by immunofluorescent (IF) tests and enzyme immunoassay (ELISA). Altogether, 292 of the sera originated from patients with clinically as well as parasitologically diagnosed (positive lesion imprint or the Montenegro skin test) cutaneous leishmaniasis; 49 of the sera were from controls from the same base population


In terms of diagnostic performance, the ELISASs for IgG and IgM yielded indices of diagnostic utility, and the positive predictive value for the IgG-ELISA was 94.6 per cent. A remarkably high specificity (100 per cent) was obtained with the IgA-IF test, but its sensitivity was very low(AU)


Assuntos
Leishmaniose/diagnóstico , Leishmaniose/epidemiologia , Imunofluorescência/normas , Técnicas Imunoenzimáticas/normas , Brasil
9.
Artigo em Inglês | PAHO | ID: pah-7362

RESUMO

The sensitivity, specificity, positive predictive value, negative predictive value, and efficiency of immunofluorescence (IF) and enzyme-linked immunoassays (ELISA) for IgG, IgM and IgA antibodies were assessed on sera from mucocutaneous lieshmaniasis patients and controls. The sensitivity of the IgG-ELISA test was 93.3 per cent with 95 per cent confidence interval higher than what could be due to a random test not associated with the disease. The specificity of all tests, except the IgM-ELISA, gave indices that could not have been due to chance. The IgG-ELISA and IgG-IF had the highest positive predictive value and the kappa statistic showed that the strength of agreement between the disease and the test was strongest for IgG-ELISA. The IgG-ELISA had a negative predictive value with 95 per cent confidence limits that were not due to chance alone. Efficiency was highest for IgG-ELISA and IgG-IF. These results were obtained using sera from patients with severe or long-standing disease and from controls in whom the disease was ruled out by a negative Montenegro skin test. In field surveys where the differences between cases and controls are less easy to define the diagnostic indices of these tests may vary with the disease prevalence(AU)


Assuntos
Leishmaniose Mucocutânea/imunologia , Ensaio de Imunoadsorção Enzimática , Imunofluorescência , Imunoglobulina A/análise , Imunoglobulina G/análise , Imunoglobulina M/análise , Valor Preditivo dos Testes
10.
Rev. Inst. Med. Trop. Säo Paulo ; 30(6): 411-4, nov.-dez. 1988. tab
Artigo em Inglês | LILACS | ID: lil-65086

RESUMO

Os parâmetros sorológicos do teste de imunoperoxidase foram comparados aos do teste de imunofluorescência. O teste de imunoperoxidase mostrou ter sensibilidade e valor de prediçäo negativo estatisticamente mais alto que aqueles do teste de imunofluorescência porém, os limites de confiança 95% da especificidade e do valor de prediçäo positivo estavam contidos naqueles encontrados para o teste de imunofluorescência. Tais diferenças se mantiveram quando os cálculos dos índices foram feitos com e sem a inclusäo de soros de doença de Chagas ou leishmaniose visceral. A análise estatística mostrou que os dois testes tinham um grau substancial de concordância mas o teste de imunofluorescência tinha um índice de especificidade e o valor de prediçäo positivo igual a 100,0% quando os soros de Chagas e leishmaniose visceral foram excluídos. Neste caso, o teste positivo se torna o teste diagnóstico da doença em face da näo existência de falso-positivos. O conjugado de peroxidase poderá se constituir em fonte de problemas técnicos na sorologia se a relaçäo enzima/proteína se afastar das quantidades ótimas de marcaçäo


Assuntos
Imunofluorescência , Leishmaniose Mucocutânea/diagnóstico , Técnicas Imunoenzimáticas/métodos
11.
Rev. Inst. Med. Trop. Säo Paulo ; 30(2): 63-7, mar.-abr. 1988. tab
Artigo em Inglês | LILACS | ID: lil-53150

RESUMO

Promastigotas de Leismania braziliensis (MHom/BR/75/M2903) foram cultivadas em meio de Schneider de cultura de drosófilas. em um tipo de experiência as formas promastigotas já haviam sido previamente adaptadas ao meio por passagens consecutivas enquanto que no segundo as promastigotas foram cultivadas em meio bifásico e depois transferidas para o meio líquido. O crescimento foi mais abundante nas células já adaptadas ao meio de cultura; células degeneradas e mortas em pequenos números, estavam presentes desde o dia 5 para promastigotas adaptadas ao meio líqüido e desde o dia 3 para células recentemente adaptadas. A síntese de antígenos de superfície diferiu de acordo com o modo como as células eram cultivadas, como verificado pelo título de 5 soros de leishmaniose mucocutânea. O melhor período para a preparaçäo de antígenos de imunofluorescência foi considerado o dia 5 para promastigotas adaptadas ao meio de cultivo e o dia 3 para células recentemente adaptadas


Assuntos
Meios de Cultura , Leishmania braziliensis/crescimento & desenvolvimento , Antígenos de Superfície/biossíntese , Leishmania braziliensis/imunologia
12.
Artigo em Espanhol | PAHO | ID: pah-16213

RESUMO

Para tratar de detrminar por cuánto tiempo se pueden almacenar los anticuerpos IgG e IgM en muestras de sangre conservadas en papel filtro, se obtuvieron muestras sanguíneas de 23 pacientes con toxoplasmosis. Se procedió a almacenar una porción de cada muestra en papel filtro a -20 °C y se dividió en tercios el suero restante; un tercio se dejó inalterado, un tercio se combinó con un volumen igual de glicerina y un tercio se liofilizó. Una vez hecho esto, todas las muestras se guardaron a -20 °C y se examinó parte de cada grupo para detectar anticuerpos IgG e IgM, practicando técnicas de inmunofluorescencia (IF) y de inmunodifusión radial (RID), después de un período de almacenamiento de 0, 3, 6, 9, 12 y 18 meses


Los resultados demostraron la dificultad de estimar cuál es la dilución de suero equivalente al eluato obtenido de las muestras almacenadas en papel filtro para fines de análisis. Además, dichos resultados indicaron que la IgG se deterioraba más rápidamente en las muestras almacenadas en papel filtro que en otras. Este deterioro relativamente más rápido de las muestras guardadas en papel filtro fue aun más marcado en el caso de la IgM... (AU)


Assuntos
Doenças Parasitárias/epidemiologia , Imunoglobulina G/intoxicação , Imunoglobulina M/intoxicação , Coleta de Amostras Sanguíneas/estatística & dados numéricos , Imunodifusão/estatística & dados numéricos , Imunofluorescência/estatística & dados numéricos
13.
Bol. Oficina Sanit. Panam ; 100(2): 129-44, feb. 1986. tab
Artigo em Espanhol | LILACS | ID: lil-34759

RESUMO

Para tratar de determinar por cuánto tiempo se pueden almacenar los anticuerpos IgG e IgM en muestras de sangre conservadas en papel filtro, se obtuvieron muestras sanguíneas de 23 pacientes con toxoplasmosis. Se procedió a almacenar una porción de cada muestra en papel filtro a - 20-C y se dividió en tercios el suero restante; un tercio se dejó inalterado, un tercio se combinó con un volumen igual de glicerina y un tercio se liofilizó. Una vez hecho esto, todas las muestras se guardaron a - 20-C y se examinó parte de cada grupo para detectar anticuerpos IgG e IgM, practicando pruebas de inmunofluorescencia (IF) y de inmunodifusión radial (RID), después de un período de almacenamiento de 0, 3, 6, 9, 12 y 18 meses. Los resultados demostraron la dificultad de estimar cuál es la dilución de suero equivalente al eluato obtenido de las muestras almacenadas en papel filtro para fines de análisis. Además, dichos resultados indicaron que la IgG se deterioraba más rápidamente en las muestras almacenadas en papel filtro que en otras. Este deterioro relativamente más rápido de las muestras guardadas en papel filtro fue aun más marcado en el caso de la IgM. Sin embargo, a pesar de estas limitaciones, cabe afirmar que el método de toma de muestras sanguíneas por punción en el dedo y almacenamiento de las mismas en papel filtro continúa siendo el mejor para fines seroepidemiológicos, ya que solo requiere una pequeña cantidad de sangre; no necesita de jeringuillas, tubos de ensayo, condiciones estrictamente estériles ni refrigeración; proporciona muestras adecuadas para muchas pruebas serológicas, y permite emplear personal no muy especializado. Además, el deterioro relativamente rápido de la IgM observado en el presente estudio indica que tal vez se podría reducir la interferencia de la IgM en las pruebas de detección de anticuerpos IgG almacenando las muestras objeto de análisis por un período suficientemente largo como para que se produza el deterioro de la IgM


Assuntos
Humanos , Inquéritos Epidemiológicos , Imunoglobulina G/análise , Imunoglobulina M/análise , Imunoglobulina G/intoxicação , Imunoglobulina M/intoxicação , Doenças Parasitárias/diagnóstico , Testes Sorológicos/métodos , Imunodifusão , Coleta de Amostras Sanguíneas , Imunofluorescência
16.
Artigo em Inglês | LILACS | ID: lil-23745

RESUMO

Os Autores descrevem a reacao de IgA ELISA na leishmaniose mucocutanea. Titulos acima do normal foram encontrados no primeiro e segundo anos de infeccao e em soros de micoses profundas acompanhados por envolvimento mucoso ou doenca disseminada


Assuntos
Humanos , Imunoglobulina A , Leishmania , Leishmaniose Mucocutânea , Micoses
17.
Rev. Inst. Med. Trop. Säo Paulo ; 25(3): 108-12, 1983.
Artigo em Inglês | LILACS | ID: lil-14021

RESUMO

A presenca de anticorpos de classe IgM e descrita numa serie de soros de leishmaniose cutanea e de individuos normais do Vale do Ribeira, Estado de Sao Paulo, Brasil. A especificidade do anticorpo foi demonstrada pela absorcao de soros IgM-positivos com gamaglubulina agregada pelo calor. Os anticorpos IgM anti-L. braziliensis estavam presentes em casos nao tratados de leishmaniose cutenea e em 43, 21% dos soros de individuos normais da mesma area. Anticorpos de classe IgG estavam presentes em 86,0% dos casos clinicos de leishmaniose cutanea


Assuntos
Humanos , Ensaio de Imunoadsorção Enzimática , Imunoglobulina G , Imunoglobulina M , Leishmaniose , Brasil
18.
Artigo | PAHO-IRIS | ID: phr-15833

RESUMO

Para tratar de detrminar por cuánto tiempo se pueden almacenar los anticuerpos IgG e IgM en muestras de sangre conservadas en papel filtro, se obtuvieron muestras sanguíneas de 23 pacientes con toxoplasmosis. Se procedió a almacenar una porción de cada muestra en papel filtro a -20 ºC y se dividió en tercios el suero restante; un tercio se dejó inalterado, un tercio se combinó con un volumen igual de glicerina y un tercio se liofilizó. Una vez hecho esto, todas las muestras se guardaron a -20 ºC y se examinó parte de cada grupo para detectar anticuerpos IgG e IgM, practicando técnicas de inmunofluorescencia (IF) y de inmunodifusión radial (RID), después de un período de almacenamiento de 0, 3, 6, 9, 12 y 18 meses


Los resultados demostraron la dificultad de estimar cuál es la dilución de suero equivalente al eluato obtenido de las muestras almacenadas en papel filtro para fines de análisis. Además, dichos resultados indicaron que la IgG se deterioraba más rápidamente en las muestras almacenadas en papel filtro que en otras. Este deterioro relativamente más rápido de las muestras guardadas en papel filtro fue aun más marcado en el caso de la IgM... (AU)


Assuntos
Doenças Parasitárias , Imunodifusão , Imunoglobulina G , Imunoglobulina M , Coleta de Amostras Sanguíneas , Imunofluorescência
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...