Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
Pediatr Infect Dis J ; 43(3): 217-225, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38134379

RESUMO

BACKGROUND: The clinical spectrum of infant COVID-19 ranges from asymptomatic infection to life-threatening illness, yet epidemiologic surveillance has been limited for infants. METHODS: Using COVID-19 case data (restricted to reporting states) and national mortality data, we calculated incidence, hospitalization, mortality and case fatality rates through March 2022. RESULTS: Reported incidence of COVID-19 was 64.1 new cases per 1000 infant years (95% CI: 63.3-64.9). We estimated that 594,012 infants tested positive for COVID-19 nationwide by March 31, 2022. Viral variant comparisons revealed that incidence was 7× higher during the Omicron (January-March 2022) versus the pre-Delta period (June 2020-May 2021). The cumulative case hospitalization rate was 4.1% (95% CI: 4.0%-4.3%). For every 74 hospitalized infants, one infant death occurred, but overall COVID-19-related infant case fatality was low, with 7.0 deaths per 10,000 cases (95% CI: 5.6-8.7). Nationwide, 333 COVID-19 infant deaths were reported. Only 13 infant deaths (3.9%) were the result of usually lethal congenital anomalies. The majority of infant decedents were non-White (28.2% Black, 26.1% Hispanic, 8.1% Asian, Indigenous or multiracial). CONCLUSIONS: More than half a million US infants contracted COVID-19 by March 2022. Longitudinal assessment of long-term infant SARS-CoV-2 infection sequelae remains a critical research gap. Extremely low infant vaccination rates (<5%), waning adult immunity and continued viral exposure risks suggest that infant COVID-19 will remain a persistent public health problem. Our study underscores the need to increase vaccination rates for mothers and infants, decrease viral exposure risks and improve health equity.


Assuntos
COVID-19 , Lactente , Adulto , Humanos , Estados Unidos/epidemiologia , COVID-19/epidemiologia , Incidência , SARS-CoV-2 , Mortalidade Infantil , Morte do Lactente
2.
Tob Induc Dis ; 17: 44, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31516487

RESUMO

INTRODUCTION: The 2016 US Surgeon General's Report suggests that the use of electronic nicotine delivery systems (ENDS) is a fetal risk factor. However, no previous study has estimated their effect on adverse pregnancy outcomes. We assessed the prevalence of current ENDS use in pregnant women and explored the effect on birth weight and smallness-for-gestational-age (SGA), correcting for misclassification from nondisclosure of smoking status. METHODS: We conducted a cohort study with 248 pregnant women using questionnaire data and biomarkers (salivary cotinine, exhaled carbon monoxide, and hair nicotine). We evaluated the association between birth weight and the risk of SGA by applying multivariate linear and log-binomial regression to reproductive outcome data for 232 participants. Participants who did not disclose their smoking status were excluded from the referent group. Sensitivity analysis corrected for misclassification of smoking/ENDS use status. RESULTS: The prevalence of current ENDS use among pregnant women was 6.8% (95% CI: 4.4-10.2%); most of these (75%) were concurrent smokers. Using self-reports, the estimated risk ratio of SGA for ENDS users was nearly two times the risk in the unexposed (RR=1.9, 95% CI: 0.6-5.5), and over three times that for ENDS-only users versus the unexposed (RR=3.1, 95% CI: 0.8-11.7). Excluding from the referent group smokers who did not disclose their smoking status, the risk of SGA for ENDS-only use was 5 times the risk in the unexposed (RR=5.1, 95% CI: 1.1- 22.2), and almost four times for all types of ENDS users (RR=3.8, 95% CI: 1.3-11.2). SGA risk ratios for ENDS users, corrected for misclassification due to self-report, were 6.5-8.5 times that of the unexposed. CONCLUSIONS: Our data suggest that ENDS use is associated with an increased risk of SGA.

3.
Tob Induc Dis ; 17: 50, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31516493

RESUMO

INTRODUCTION: Public awareness of electronic nicotine delivery systems (ENDS) has increased over time, and the perception that ENDS offer a safer alternative to cigarettes may lead some pregnant women to use them to reduce cigarette smoking during pregnancy. No previous studies have used metabolite levels in hair to measure nicotine exposure for ENDS users during pregnancy. We aimed to measure and compare levels of nicotine, cotinine, and tobacco-specific nitrosamines (TSNAs) in hair samples from pregnant women who were current ENDS users, current smokers, and current non-smokers. We also aimed to estimate the association between ENDS use/smoking and smallness for gestational age (SGA). METHODS: We used hair specimens from pregnant women who were dual users (ENDS and cigarettes), smokers, and non-smokers from a prospective cohort study to estimate exposure to nicotine, cotinine, and TSNAs. The exposure biomarkers and self-reports of smoking and ENDS use were used in log-binomial regression models to estimate risk ratios (RRs) for SGA among offspring. RESULTS: Nicotine concentrations for pregnant dual users were not significantly different from those for smokers (11.0 and 10.6 ng/mg hair, respectively; p=0.58). Similarly, levels of cotinine, and TSNAs for pregnant dual users were not lower than those for smokers. The RR for SGA was similar for dual users and smokers relative to nonsmokers, (RR=3.5, 95% CI: 0.8-14.8) and (RR=3.3, 95% CI: 0.9-11.6), respectively. Using self-reports confirmed by hair nicotine, the RR values for dual ENDS users and smokers were 8.3 (95% CI: 1.0-69.1) and 7.3 (95% CI:1.0-59.0), respectively. CONCLUSIONS: We did not observe lower levels of nicotine, cotinine, and TSNAs for current dual users compared to smokers during pregnancy. The risk of SGA for offspring of pregnant dual users was similar to that for offspring of pregnant smokers. Future studies are needed to further estimate the magnitude of the association between ENDS use and smallness for gestational age.

4.
Birth Defects Res ; 111(16): 1192-1204, 2019 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-31313527

RESUMO

BACKGROUND: With their unique history of exposure to extensive nuclear testing between 1946 and 1958, descendants of Marshall Island residents may have underappreciated genetic abnormalities, increasing their risk of birth defects. METHODS: We conducted a retrospective cohort study of resident women with at least one singleton live birth between 1997 and 2013 in northwest Arkansas using state birth certificate data linked to data from the Arkansas Reproductive Health Monitoring System, a statewide birth defects registry. We calculated unadjusted and adjusted prevalence ratios (PR) and 95% confidence intervals (CI) from modified Poisson regression analyses for non-Hispanic (NH) whites, NH-blacks, Hispanics and Marshallese, using NH-whites as the reference group. RESULTS: Of the 91,662 singleton births during the study period, 2,488 were to Marshallese women. Due to the relatively small number of Marshallese births, we could not calculate prevalence estimates for some defects. Marshallese infants had higher rates of congenital cataracts (PR = 9.3; 95% CI: 3.1, 27.9). Although the number of defects was low, Marshallese infants also had higher rates of truncus arteriosus (PR = 44.0; 95% CI: 2.2, 896.1). CONCLUSIONS: Marshallese infants may have increased risk of specific birth defects, but estimates are unstable because of small sample size so results are inconclusive. Larger population-based studies would allow for further investigation of this potential risk among Marshallese infants.


Assuntos
Anormalidades Induzidas por Radiação/embriologia , Anormalidades Congênitas/epidemiologia , Adulto , Catarata/etiologia , Estudos de Coortes , Anormalidades Congênitas/etiologia , Feminino , Humanos , Recém-Nascido , Nascido Vivo , Micronésia/epidemiologia , Parto , Gravidez , Gravidez Múltipla , Prevalência , Liberação Nociva de Radioativos , Sistema de Registros , Estudos Retrospectivos , Tronco Arterial
5.
Obstet Gynecol Surv ; 73(9): 544-549, 2018 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-30265741

RESUMO

IMPORTANCE: Electronic cigarette (e-cigarette) use in pregnancy has been steadily increasing and has been hyped as being a safe alternative to cigarette smoking during pregnancy. This review discloses what is currently known about e-cigarette use in pregnancy and the effects of its use on pregnancy outcomes. OBJECTIVE: To determine what is currently known about the prevalence of e-cigarette use in pregnancy and the effects of e-cigarette use on pregnancy and perinatal/neonatal outcomes. EVIDENCE ACQUISITION: A PubMed, CINAHL, and EMBASE search was undertaken using the search terms "pregnancy" OR "pregnancy complications" OR "pregnancy outcome" OR "newborn" OR "neonate" OR "birth" AND "electronic cigarettes" OR "e-cigarettes" OR "ecigarettes" OR "vaping" OR "vape." The search was limited to the English language and between 2007 and October 12, 2017. RESULTS: The search identified 91 articles, 40 of which are the basis for this review. The prevalence of e-cigarette use is 0.6% to 15%. The amount of nicotine consumed by e-cigarette users is comparable to that consumed by cigarette smokers. Most of the animal model studies suggest a potential danger to the developing fetus primarily because of the nicotine consumed and that consumption has multiple effects on the immune system, neural development, lung function, and cardiac function. There is a widespread flawed perception that e-cigarettes are safe to use during pregnancy. CONCLUSIONS: The marketing of e-cigarette use as a safer alternative to cigarette smoking has led to an increasing use even in pregnancy. The nicotine consumed by e-cigarettes is similar to that consumed by cigarette smoking. Animal studies confirm the dangers of nicotine to the developing fetus. More research needs to be done specifically assessing e-cigarette use, pregnancy, and pregnancy outcomes. RELEVANCE: The amount of nicotine consumed in cigarette smoking is similar to the amount of nicotine consumed with e-cigarettes. The effects of nicotine exposure during fetal development are well known and include effects on multiple organ systems.


Assuntos
Sistemas Eletrônicos de Liberação de Nicotina , Gestantes , Fumar/efeitos adversos , Feminino , Humanos , Nicotina/efeitos adversos , Gravidez , Efeitos Tardios da Exposição Pré-Natal/induzido quimicamente , Abandono do Hábito de Fumar/métodos
6.
J Agric Saf Health ; 24(4): 213-225, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-32801608

RESUMO

This study applied a text string search algorithm to ascertain suspect farm tractor or agricultural machinery-related injuries in data sources available for 2000-2014 in the state of Arkansas. The occurrences of tractor or other agricultural machinery-related injuries were compared with data available from the Centers for Disease Control and Prevention's National Center for Health Statistics (NCHS) and the Bureau of Labor Statistics' Census of Fatal Occupational Injuries (CFOI). For death certificates that assigned an external cause of death, the authors first collected all those that were coded as related to agricultural machinery, based on search strings for occupation and industry and a description of how the injury occurred. They then inspected each case individually and removed those that were likely unrelated to agricultural machinery. This approach significantly increased (by 7.8 times) the number of suspect agricultural machinery-related fatalities compared to the number reported to CFOI, but there was only a 17% (not statistically significant) increase compared to NCHS. All hospital records with any discharge diagnosis coded as related to agricultural machinery were selected. Descriptive analysis of the fatalities and hospital records showed a significantly increased risk among men above retirement age, peaks during the summer, and an increased risk in the Mississippi delta region. About one-third of the agricultural machinery-related fatalities were due to overturns. The use of the algorithm can improve ascertainment of fatal agricultural machinery-related injuries in Arkansas. The death records were found to be rich in data on the circumstances of the injuries, which can be used to screen for tractor-related fatalities and, if confirmed, translated into action to improve the safety of Arkansas farmers.

7.
Public Health Rep ; 132(2): 210-219, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28147209

RESUMO

OBJECTIVES: As of October 2015, evidence needed to make a recommendation about the use of electronic nicotine delivery systems (ENDS) for smoking cessation was limited. We used the 2014 Arkansas Behavioral Risk Factor Surveillance System with additional state-specific questions to determine the prevalence of ENDS use, the impact of ENDS use on smoking cessation, and beliefs about ENDS use in Arkansas. Our objectives were to determine if (1) ENDS use was associated with lower odds of quitting smoking, (2) ENDS users believed that ENDS use was not harmful to their health, and (3) ENDS users believed that switching to ENDS reduced their tobacco-related health risks. METHODS: We conducted a cross-sectional study of 4465 respondents to the Arkansas Behavioral Risk Factor Surveillance System and used weighted analyses to account for the complex survey design. We used a subset of records formed by (1) formers smokers who quitted smoking in the last 5 years and (2) current smokers to assess the odds of quitting. RESULTS: In 2014, 6.1% (95% confidence interval [CI], 5.0%-7.4%) of Arkansas adults were currently using ENDS. Of the 1083 participants who were current smokers or had quit smoking within the past 5 years, 515 (54.1%) had used ENDS. Of the 515 ENDS users, 404 (80.3%) had continued smoking. ENDS use was significantly associated with reduced odds of quitting smoking (weighted odds ratio = 0.53; 95% CI, 0.34-0.83). Although 2437 of 3808 participants (62.5%) believed that it was harmful for nonsmokers to start using ENDS and 1793 of 3658 participants (47.0%) believed that switching to ENDS did not reduce tobacco-related health risks, only 80 of 165 (41.3%) and 50 of 168 (33.9%) ENDS users shared these same respective beliefs. CONCLUSIONS: Most smokers who indicated smoking in the past 5 years and who tried ENDS did not stop smoking. ENDS use was inversely associated with smoking cessation. Tobacco cessation programs should tell cigarette smokers that ENDS use may not help them quit smoking.


Assuntos
Sistemas Eletrônicos de Liberação de Nicotina , Nebulizadores e Vaporizadores , Nicotina/administração & dosagem , Abandono do Hábito de Fumar , Adolescente , Adulto , Idoso , Arkansas , Estudos Transversais , Feminino , Inquéritos Epidemiológicos , Humanos , Masculino , Pessoa de Meia-Idade , Adulto Jovem
8.
J Empir Res Hum Res Ethics ; 11(3): 250-5, 2016 07.
Artigo em Inglês | MEDLINE | ID: mdl-27534588

RESUMO

There is no standard policy regarding the regulatory or institutional approval of N-of-1 trials in the United States. The objective of this study was to examine whether institutional review boards (IRBs) accredited by the Association for the Accreditation of Human Research Protection Programs (AAHRPP) consider N-of-1 trials as meeting the definition of human subjects research (45CFR46.102) and requiring IRB approval. A questionnaire was distributed via email to 170 AAHRPP-accredited IRBs in the United States. Responses were analyzed using statistical and qualitative methods. Nineteen of 59 respondents reported viewing N-of-1 trials as research. Twelve respondents reported having a policy regarding N-of-1 trials, and in all cases, such policies did not consider N-of-1 trials as meeting the definition of research. This topic deserves wider examination in the IRB literature and community to inform policies and guidance as N-of-1 trials become more common in the pursuit of personalized, precision medicine.


Assuntos
Atitude , Pesquisa Biomédica/ética , Revisão Ética , Comitês de Ética em Pesquisa , Medicina de Precisão , Pesquisa Biomédica/métodos , Ética em Pesquisa , Humanos , Sujeitos da Pesquisa , Inquéritos e Questionários , Estados Unidos
9.
J Am Coll Cardiol ; 64(15): 1580-7, 2014 Oct 14.
Artigo em Inglês | MEDLINE | ID: mdl-25301461

RESUMO

BACKGROUND: Cardiovascular risk factors are associated with left ventricular hypertrophy (LVH), but little is known regarding related impact of longitudinal measures of childhood adiposity and LV hemodynamic variables. OBJECTIVES: The aim of this study was to examine the impact of cumulative long-term burden and trends of excessive adiposity and elevated blood pressure (BP) during childhood on adulthood LVH and LV geometric remodeling patterns. METHODS: This longitudinal study consisted of 1,061 adults, age 24 to 46 years, who had been examined 4 or more times for body mass index (BMI) and BP starting in childhood, with a mean follow-up of 28.0 years. The area under the curve (AUC) was calculated as a measure of long-term burden (total AUC) and trends (incremental AUC) of BMI and BP from childhood to adulthood. Four LV geometric types were defined-normal, concentric remodeling (CR), eccentric hypertrophy (EH), and concentric hypertrophy (CH)-all on the basis of LV mass indexed for body height (m(2.7)) and relative wall thickness. RESULTS: Higher values of BMI and systolic and diastolic BP in childhood and adulthood, as well as total AUC and incremental AUC, were all significantly associated with higher LV mass index and LVH, adjusted for race, sex, and age. In addition, higher values of BMI and BP in childhood and adulthood, total AUC, and incremental AUC were significantly associated with EH and CH but not with CR. Importantly, all of these measures of BMI had a consistently and significantly greater influence on EH than did measures of BP. CONCLUSIONS: These findings indicate that the adverse influence of excessive adiposity and elevated BP levels on LVH begins in childhood.


Assuntos
Adiposidade/fisiologia , Pressão Sanguínea/fisiologia , Previsões , Hipertrofia Ventricular Esquerda/fisiopatologia , Medição de Risco/métodos , Função Ventricular Esquerda , Remodelação Ventricular/fisiologia , Adolescente , Adulto , Criança , Pré-Escolar , China/epidemiologia , Estudos Transversais , Progressão da Doença , Ecocardiografia , Feminino , Seguimentos , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/fisiopatologia , Humanos , Hipertrofia Ventricular Esquerda/diagnóstico por imagem , Hipertrofia Ventricular Esquerda/epidemiologia , Incidência , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Risco , Adulto Jovem
10.
PLoS One ; 7(11): e47767, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-23152759

RESUMO

Multilocus sequence typing (MLST) based on six loci was used to analyze the relationship of 58 Candida tropicalis isolates from individual patients in a general hospital in Beijing, China. A total of 52 diploid sequence types (DSTs) were generated by the MLST, all of which were new to the central database. Unweighted Pair Group Method with Arithmetic Mean (UPGMA) dendrograms were constructed, which showed that the 58 isolates were distributed robustly and 6 main groups were clustered regardless of the specimen source and medical department. The minimum spanning tree (MST) of the 58 isolates (52 DSTs) and all 401 isolates (268 DSTs) in the C. tropicalis central database (http://pubmlst.org/ctropicalis/) indicated that the isolates in this study clustered in three relative pure clonal complexes, and 2 clustered with isolates from Taiwan, Belgium, Brazil, and the US. This study presents the first MLST analysis of C. tropicalis isolates from Mainland China, which may be useful for further studies on the similarity, genetic relationship, and molecular epidemiology of C. tropicalis strains worldwide.


Assuntos
Candida tropicalis/genética , Tipagem de Sequências Multilocus , Candida tropicalis/isolamento & purificação , China , Bases de Dados Genéticas , Genes Fúngicos , Hospitais Gerais , Humanos , Filogenia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...