Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Chromatogr A ; 1685: 463623, 2022 Dec 06.
Artigo em Inglês | MEDLINE | ID: mdl-36347074

RESUMO

Open-Tubular Liquid Chromatography (OTLC) is currently limited by two shortcomings, namely the low ratio of adsorbing area to the channel volume and the large values of the Height Equivalent of the Theoretical Plate (HETP) due to Taylor-Aris dispersion. Previous work focusing on axial dispersion of nonadsorbing solutes showed how it is possible to tame the Taylor-Aris effect by inducing transversal velocity components acting alongside the main pressure-driven axial flow. We here analyze the impact of transversal flow on the separation resolution in OTLC, where simultaneous equilibrium adsorption at the channel walls is superimposed to the analyte transport in the mobile phase. A three-dimensional steady flow generated by the combination of a pressure-driven flow and an electroosmotically-induced transversal flow is used as case study. Flows geometries possessing regular and chaotic streamlines are created by axially-invariant and periodically-alternate arrangements of the electrodes along the channel walls, respectively. By enforcing Brenner's macrotransport approach, we predict the column length achieving a prescribed level of resolution as a function of the Péclet number and of the species affinity towards the stationary adsorbing phase. Results show that the presence of transversal flows can lower sensitively the dependence of the column length on the Péclet number. Flows possessing chaotic streamlines prove the most efficient choice at large eluent velocities and low values of the column adsorption constant.


Assuntos
Cromatografia Líquida , Cromatografia Líquida/métodos , Adsorção
2.
Anal Chem ; 94(46): 15980-15986, 2022 11 22.
Artigo em Inglês | MEDLINE | ID: mdl-36370088

RESUMO

Hydrodynamic chromatography (HDC) is a well-established analytical separation method for the size separation of nano- and microparticles and large molecular weight solutes such as synthetic polymers and proteins. We report on a theoretical study showing that the separation resolution of open-tubular HDC can be significantly enhanced by changing the cross-sectional shape of the separation channel. By enforcing Brenner's macro-transport approach, we provide theoretical/numerical evidence showing how the shape of the cross section influences quantitatively both the selectivity and the axial dispersion of the suspended particles in HDC. The separation performance of square-, triangle-, and star-shaped channel cross sections is compared to that of a cylindrical capillary over three decades of the particle Péclet number in terms of the minimal separation length and time to obtain the unit resolution of a two-particle mixture. Enhancement factors up to 400% are found in the case of triangular shapes, with the best performing case being the 70.6° angle, which can be obtained by KOH etching of bulk silicon.


Assuntos
Cromatografia , Hidrodinâmica , Tamanho da Partícula , Cromatografia/métodos , Polímeros/química , Peso Molecular
3.
Membranes (Basel) ; 12(11)2022 Nov 08.
Artigo em Inglês | MEDLINE | ID: mdl-36363670

RESUMO

Membrane reactors are inherently two-dimensional systems that require complex models for an accurate description of the different transport phenomena involved. However, when their performance is limited by mass transport within the reactor rather than by the selective product permeation across the membrane, the 2D model may be significantly simplified. Here we extend results previously found for methane steam reforming membrane reactors to show that such simplified two-dimensional model admits either a straightforward analytical solution for the cross-section averaged concentration profile, or can be reduced to a 1D model with an enhanced Sherwood number, depending on the stoichiometry of the reaction considered. Interestingly, the stoichiometry does not affect the expression of the enhanced Sherwood number, indicating that a versatile tool has been developed for the determination of membrane reactor performance at an extremely low computational cost and good degree of accuracy.

4.
Anal Chem ; 94(27): 9872-9879, 2022 07 12.
Artigo em Inglês | MEDLINE | ID: mdl-35765941

RESUMO

Despite its relatively long history, open-channel hydrodynamic chromatography (OC-HDC) still represents a niche technique for determining the size distribution of particle suspensions. Practical limitations of this separation method ultimately arise from the low eluent velocity that is necessary to contain the adverse increase of analyte bandwidth caused by Taylor-Aris dispersion. Because of the micrometric size of the channel cross section, the low eluent velocity translates into order of pL-per-minute flow rates, which introduce a challenge for both the injection and the detection systems. In this article, we provide theoretical/numerical evidence illustrating how a sizable reduction of the Taylor-Aris effect can be obtained by triggering cross-sectional vortices alongside the main pressure-driven axial flow. As a case study, we consider a square channel geometry where the lateral vortices are created by DC-induced electroosmosis. The analysis of particle separation is based on the classical excluded-volume macrotransport approach, which allows to derive the average particle velocity and the axial dispersion coefficient from the solution of two stationary advection-diffusion problems defined onto the channel cross section. We find that lateral vortices can enhance the separation efficiency quantitatively, e.g., by reducing the separation time of a two-species mixture by a 50-fold factor compared to standard OC-HDC.


Assuntos
Eletro-Osmose , Hidrodinâmica , Cromatografia/métodos , Estudos Transversais , Difusão
5.
J Chromatogr A ; 1673: 463110, 2022 Jun 21.
Artigo em Inglês | MEDLINE | ID: mdl-35537353

RESUMO

Taylor-Aris dispersion represents an undesired phenomenon in pressure-driven liquid chromatography, often responsible for the unchecked increase of the Height Equivalent of the Theoretical Plate (HETP) when high throughput operating conditions are sought. Previous work on the subject showed how it is possible to contain the augmented dispersion in empty microchannels by inducing cross-sectional velocity components yielding an overall helical structure of the flow streamlines. Here, we explore the possibility of further reducing axial dispersion by devising flow conditions that give rise to chaotic streamlines. A three-dimensional steady flow generated by the combination of a pressure-driven Poiseuille flow and an electroosmotically-induced spatially periodic flow is used as a case study. Brenner's macrotransport approach is used to predict the axial dispersion coefficient of a diffusing solute in flows possessing regular, partially chaotic and globally chaotic kinematic features. Accurate Lagrangian-stochastic simulations of particle ensembles are used to validate the predictions obtained through Brenner's paradigm. Our findings suggest that the Taylor-Aris phenomenon can be altogether suppressed in the limit of globally chaotic kinematics. A theoretical interpretation of this outcome is developed by combining macrotransport theory with established results of the spectral approach to mixing in advecting-diffusing chaotic flows.


Assuntos
Estudos Transversais , Difusão , Soluções
6.
J Chromatogr A ; 1659: 462652, 2021 Dec 06.
Artigo em Inglês | MEDLINE | ID: mdl-34742132

RESUMO

In a recent article [Analytical Chemistry, 93(17), 6808-6816 (2021)], an unconventional device configuration enforcing a Brownian sieving mechanism was proposed as proof of concept for the efficient implementation of microcapillary hydrodynamic chromatography (MHDC). In this article, we perform a thorough analysis of the device geometry and of operating conditions, in order to single out the optimal configuration maximizing separation resolution. Brenner's macro-transport theory provides the technical picklock to perform the search for the optimum over a wide choice of device geometries and for a range of values of the particle Péclet number covering most conditions encountered in practical implementations of MHDC. Specifically, effective transport coefficients defining the dynamics of the suspended phase are obtained by the solution of a two-dimensional steady-state advection-diffusion equation defined onto the channel cross-section. The eigenvalue/eigenfunction structure of the associated transient problem is exploited in order to quantify the timescale for reaching the macro-transport regime conditions. Based on this timescale and on the effective transport parameters, an estimate of the column length necessary to achieve a prescribed level of separation resolution is obtained. We identify device geometry and operating conditions where the capillary length is shrunk down by a factor above ten compared to the standard MHDC configuration. Lagrangian stochastic statistics of particle ensembles are used to validate the results obtained through Brenner's macro-transport approach. The method proposed can be readily generalized to other classes of device geometries enforcing the same Brownian sieving mechanism.


Assuntos
Cromatografia , Hidrodinâmica , Difusão
7.
Anal Chem ; 93(17): 6808-6816, 2021 05 04.
Artigo em Inglês | MEDLINE | ID: mdl-33890769

RESUMO

Microcapillary hydrodynamic chromatography (MHDC) is a well-established technique for the size-based separation of suspensions and colloids, where the characteristic size of the dispersed phase ranges from tens of nanometers to micrometers. It is based on hindrance effects which prevent relatively large particles from experiencing the low velocity region near the walls of a pressure-driven laminar flow through an empty microchannel. An improved device design is here proposed, where the relative extent of the low velocity region is made tunable by exploiting a two-channel annular geometry. The geometry is designed so that the core and the annular channel are characterized by different average flow velocities when subject to one and the same pressure drop. The channels communicate through openings of assigned cut-off length, say A. As they move downstream the channel, particles of size bigger than A are confined to the core region, whereas smaller particles can diffuse through the openings and spread throughout the entire cross section, therein attaining a spatially uniform distribution. By using a classical excluded-volume approach for modeling particle transport, we perform Lagrangian-stochastic simulations of particle dynamics and compare the separation performance of the two-channel and the standard (single-channel) MHDC. Results suggest that a quantitative (up to thirtyfold) performance enhancement can be obtained at operating conditions and values of the transport parameters commonly encountered in practical implementations of MHDC. The separation principle can readily be extended to a multistage geometry when the efficient fractionation of an arbitrary size distribution of the suspension is sought.

8.
Biosensors (Basel) ; 10(9)2020 Sep 16.
Artigo em Inglês | MEDLINE | ID: mdl-32947949

RESUMO

Microfluidic separators based on Deterministic Lateral Displacement (DLD) constitute a promising technique for the label-free detection and separation of mesoscopic objects of biological interest, ranging from cells to exosomes. Owing to the simultaneous presence of different forces contributing to particle motion, a feasible theoretical approach for interpreting and anticipating the performance of DLD devices is yet to be developed. By combining the results of a recent study on electrostatic effects in DLD devices with an advection-diffusion model previously developed by our group, we here propose a fully predictive approach (i.e., ideally devoid of adjustable parameters) that includes the main physically relevant effects governing particle transport on the one hand, and that is amenable to numerical treatment at affordable computational expenses on the other. The approach proposed, based on ensemble statistics of stochastic particle trajectories, is validated by comparing/contrasting model predictions to available experimental data encompassing different particle dimensions. The comparison suggests that at low/moderate values of the flowrate the approach can yield an accurate prediction of the separation performance, thus making it a promising tool for designing device geometries and operating conditions in nanoscale applications of the DLD technique.


Assuntos
Dispositivos Lab-On-A-Chip , Técnicas Analíticas Microfluídicas , Microfluídica , Eletricidade Estática
9.
Membranes (Basel) ; 8(2)2018 Jun 19.
Artigo em Inglês | MEDLINE | ID: mdl-29921794

RESUMO

Membrane reactors for hydrogen production have been extensively studied in the past years due to the interest in developing systems that are adequate for the decentralized production of high-purity hydrogen. Research in this field has been both experimental and theoretical. The aim of this work is two-fold. On the one hand, modeling work on membrane reactors that has been carried out in the past is presented and discussed, along with the constitutive equations used to describe the different phenomena characterizing the behavior of the system. On the other hand, an attempt is made to shed some light on the meaning and usefulness of models developed with different degrees of complexity. The motivation has been that, given the different ways and degrees in which transport models can be simplified, the process is not always straightforward and, in some cases, leads to conceptual inconsistencies that are not easily identifiable or identified.

10.
Anal Chem ; 81(19): 8009-14, 2009 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-19739656

RESUMO

This article develops the theoretical analysis of transport and dispersion phenomena in wide-bore chromatography at values of the Peclet number Pe beyond the upper bound of validity of the Taylor-Aris theory. It is shown that for Poiseuille flows in cylindrical capillaries the average residence time grows logarithmically with the Peclet number, while the variance of the outlet chromatogram scales as the power 1/3 of Pe. In the presence of slip boundary conditions, both the mean and the variance of the outlet chromatograms saturate at high Pe, and this phenomenon provides an indirect transport-based way to detect slip flow conditions at the solid walls and, more generally, flow distributions in channel flows.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...