Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Radiol Med ; 129(6): 864-878, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38755477

RESUMO

OBJECTIVE: To evaluate the performance of radiomic analysis on contrast-enhanced mammography images to identify different histotypes of breast cancer mainly in order to predict grading, to identify hormone receptors, to discriminate human epidermal growth factor receptor 2 (HER2) and to identify luminal histotype of the breast cancer. METHODS: From four Italian centers were recruited 180 malignant lesions and 68 benign lesions. However, only the malignant lesions were considered for the analysis. All patients underwent contrast-enhanced mammography in cranium caudal (CC) and medium lateral oblique (MLO) view. Considering histological findings as the ground truth, four outcomes were considered: (1) G1 + G2 vs. G3; (2) HER2 + vs. HER2 - ; (3) HR + vs. HR - ; and (4) non-luminal vs. luminal A or HR + /HER2- and luminal B or HR + /HER2 + . For multivariate analysis feature selection, balancing techniques and patter recognition approaches were considered. RESULTS: The univariate findings showed that the diagnostic performance is low for each outcome, while the results of the multivariate analysis showed that better performances can be obtained. In the HER2 + detection, the best performance (73% of accuracy and AUC = 0.77) was obtained using a linear regression model (LRM) with 12 features extracted by MLO view. In the HR + detection, the best performance (77% of accuracy and AUC = 0.80) was obtained using a LRM with 14 features extracted by MLO view. In grading classification, the best performance was obtained by a decision tree trained with three predictors extracted by MLO view reaching an accuracy of 82% on validation set. In the luminal versus non-luminal histotype classification, the best performance was obtained by a bagged tree trained with 15 predictors extracted by CC view reaching an accuracy of 94% on validation set. CONCLUSIONS: The results suggest that radiomics analysis can be effectively applied to design a tool to support physician decision making in breast cancer classification. In particular, the classification of luminal versus non-luminal histotypes can be performed with high accuracy.


Assuntos
Inteligência Artificial , Neoplasias da Mama , Meios de Contraste , Mamografia , Humanos , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/patologia , Feminino , Pessoa de Meia-Idade , Mamografia/métodos , Idoso , Itália , Adulto , Gradação de Tumores , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Receptor ErbB-2 , Sensibilidade e Especificidade , Radiômica
2.
Radiol Med ; 127(7): 733-742, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35579854

RESUMO

OBJECTIVE: To analyze dosimetric data of a single center by a radiation dose index monitoring software evaluating quantitatively the dose reduction obtained with the implementation of the adaptive statistical iterative reconstruction (ASIR) on Computed Tomography in terms of both the value of the dose length product (DLP) and the alerts provided by the dose tool. METHODS: Dosimetric quantities were acquired using Qaelum DOSE tool (QAELUM NV, Leuven-Heverlee, Belgium). Dose data pertaining to CT examinations were performed using a General Electric Healthcare CT tomography with 64 detectors. CT dose data were collected over 4 years (January 1, 2017 to December 31, 2020) and included CT dose length product (DLP). Moreover, all CT examinations that triggered a high radiation dose (twice the median for that study description), termed alerts on Dose tool, were retrieved for the analysis. Two radiologists retrospectively assessed CT examinations in consensus for the images quality and for the causes of the alerts issued. A Chi-square test was used to assess whether there were any statistically significant differences among categorical variable while a Kruskal Wallis test was considered to assess differences statistically significant for continuous variables. RESULTS: Differences statistically significant were found for the DLP median values between the dosimetric data recorded on 2017-2018 versus 2019-2020. The differences were linked to the implementation of ASIR technique at the end of 2018 on the CT scanner. The highest percentage of alerts was reported in the CT study group "COMPLETE ABDOMEN + CHEST + HEAD" (range from 1.26% to 2.14%). A reduction year for year was relieved linked to the CT protocol optimization with a difference statistically significant. The highest percentage of alerts was linked to wrong study label/wrong study protocol selection with a range from 29 to 40%. CONCLUSIONS: Automated methods of radiation dose data collection allowed for detailed radiation dose analysis according to protocol and equipment over time. The use of CT ASIR technique could determine considerable reduction in radiation dose.


Assuntos
Interpretação de Imagem Radiográfica Assistida por Computador , Tomografia Computadorizada por Raios X , Algoritmos , Humanos , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Estudos Retrospectivos , Software , Tomografia Computadorizada por Raios X/métodos
3.
Magn Reson Imaging ; 75: 51-59, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-33080334

RESUMO

PURPOSE: The purpose of this study is to assess Blood oxygenation level dependent Magnetic Resonance Imaging (BOLD-MRI) and Diffusion Weighted Magnetic Resonance Imaging (DW-MRI) in the differentiation of benign and malignant breast lesions. METHODS: Fifty-nine breast lesions (26 benign and 33 malignant lesions) pathologically proven in 59 patients were included in this retrospective study. As BOLD parameters were estimated basal signal S0 and the relaxation rate R2*, diffusion and perfusion parameters were derived by DWI (pseudo-diffusion coefficient (Dp), perfusion fraction (fp) and tissue diffusivity (Dt)). Wilcoxon-Mann-Whitney U test and Receiver operating characteristic (ROC) analyses were calculated and area under ROC curve (AUC) was obtained. Moreover, pattern recognition approaches (linear discrimination analysis (LDA), support vector machine, k-nearest neighbours, decision tree) with least absolute shrinkage and selection operator (LASSO) method and leave one out cross validation approach were considered. RESULTS: A significant discrimination was obtained by the standard deviation value of S0, as BOLD parameter, that reached an AUC of 0.76 with a sensitivity of 65%, a specificity of 85% and an accuracy of 76%. No significant discrimination was obtained considering diffusion and perfusion parameters. Considering LASSO results, the features to use as predictors were all extracted parameters except that the mean value of R2* and the best result was obtained by a LDA that obtained an AUC = 0.83, with a sensitivity of 88%, a specificity of 77% and an accuracy of 83%. CONCLUSIONS: Good performance to discriminate benign and malignant lesions could be obtained using BOLD and DWI derived parameters with a LDA classification approach. However, these findings should be proven on larger and several dataset with different MR scanners.


Assuntos
Neoplasias da Mama/sangue , Neoplasias da Mama/diagnóstico por imagem , Imagem de Difusão por Ressonância Magnética , Oxigênio/sangue , Adulto , Idoso , Neoplasias da Mama/patologia , Diagnóstico Diferencial , Difusão , Feminino , Humanos , Pessoa de Meia-Idade , Curva ROC , Estudos Retrospectivos , Máquina de Vetores de Suporte
4.
Med Lav ; 109(6): 471-477, 2018 Dec 20.
Artigo em Inglês | MEDLINE | ID: mdl-30556537

RESUMO

BACKGROUND: Following recent epidemiological studies, which showed tissue reactions from ionizing radiation at significantly lower doses, the 2013/59 EURATOM Directive of 5th December 2013 lowered the limit on the equivalent dose to the eye lens from 150 mSv to 20 mSv per year. Therefore, as a precautionary measure, it is considered appropriate to perform a timely dose monitoring by using specific dosimeters. OBJECTIVES: Analysis of the current state of the eye lens exposures during interventional procedures. The survey aimed at assessing the degree of information available to the exposed workers as regards lowering the dose limit in Interventional Radiology departments of some hospitals in Campania (Southern Italy). METHODS: The equivalent dose was assessed, over a period of 90 days, using specific Hp dosimeters(3), placed sideways with regard to prescription eye glasses. The level of awareness of the new dose limit among operators was assessed using a questionnaire. RESULTS: The values of the equivalent dose to the lens of the eye for the I and II Operators were found to be <150 mSv/year but for the I Operator a value of 54 mSv/year was obtained, ie higher than 20 mSv/year, that is the new limit of the equivalent dose according to 2013/59 EURATOM. The initial results of the questionnaire from 52 exposed workers, of which 46 (88%) were from exposure category A and 6 (12%) from category B, showed a low level of information (19%). CONCLUSIONS: The results highlight not only the importance of using specific devices for individual protection but also the importance of the level of training and information the exposed medical staff are given concerning the new regulations.


Assuntos
Cristalino , Exposição Ocupacional , Exposição à Radiação , Proteção Radiológica , Humanos , Cristalino/efeitos da radiação , Doses de Radiação , Radiologia Intervencionista
5.
Front Public Health ; 5: 344, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-29326919

RESUMO

Magnetic resonance imaging (MRI) has evolved rapidly over the past few decades as one of the most flexible tools in medical research and diagnostic imaging. MRI facilities are important sources of multiple exposure to electromagnetic fields for both patients and health-care staff, due to the presence of electromagnetic fields of multiple frequency ranges, different temporal variations, and field strengths. Due to the increasing use and technological advancements of MRI systems, clearer insights into exposure assessment and a better understanding of possible harmful effects due to long-term exposures are highly needed. In the present exploratory study, exposure assessment and biomonitoring of MRI workers at the Radio-diagnostics Unit of the National Cancer Institute of Naples "Pascale Foundation" (Naples, Italy) have been carried out. In particular, exposure to the MRI static magnetic field (SMF) has been evaluated by means of personal monitoring, while an application tool has been developed to provide an estimate of motion-induced, time-varying electric fields. Measurement results have highlighted a high day-to-day and worker-to-worker variability of the exposure to the SMF, which strongly depends on the characteristics of the environment and on personal behaviors, and the developed application tool can be adopted as an easy-to-use tool for rapid and qualitative evaluation of motion-induced, time-varying electric field exposure. Regarding biomonitoring, the 24 workers of the Radio-diagnostics Unit were enrolled to evaluate both spontaneous and mitomycin C-induced chromosomal fragility in human peripheral blood lymphocytes, by means of the cytokinesis-block micronucleus assay. The study subjects were 12 MRI workers, representative of different professional categories, as the exposed group, and 12 workers with no MRI exposure history, as the reference group. The results show a high worker-to-worker variability for both field exposure assessment and biomonitoring, as well as several critical issues and practicalities to be faced with in this type of investigations. The procedures for risk assessment and biomonitoring proposed here can be used to inform future research in this field, which will require a refinement of exposure assessment methods and an enlargement of the number of subjects enrolled in the biomonitoring study to gain robust statistics and reliable results.

6.
Free Radic Biol Med ; 46(1): 110-6, 2009 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-18996183

RESUMO

Organisms exposed to ionizing radiation are mainly damaged by free radicals, which are generated by the radiolysis of water contained in the cells. Recently a significant reduction of tissue injury from irradiation damage was demonstrated by using MnSOD-plasmid/liposome treatments in the protection of murine lung. In this study we show that a new active recombinant human MnSOD (rMnSOD), easily administered in vivo, not only exerts the same radioprotective effect on normal cells and organisms as any MnSOD, but it is also radiosensitizing for tumor cells. In addition, we show how healthy animals, exposed to lethal doses of ionizing radiation and daily injections with rMnSOD, were protected from radiodamage and were still alive 30 days after the irradiation, while animals treated with only PBS solution, in the absence of rMnSOD, died after 7-8 days from the radiotreatments. The molecular analysis of all irradiated tissues revealed that the antiapoptotic AVEN gene appeared activated only in the animals treated in the presence of rMnSOD. The data suggest that rMnSOD deserves to be considered as a pharmaceutical tool for making radiotherapy more selective on cancer cells and to prevent and/or cure the accidental damage derived from exposure to ionizing radiation.


Assuntos
Proteínas Adaptadoras de Transdução de Sinal/biossíntese , Proteínas Reguladoras de Apoptose/metabolismo , Fibroblastos/efeitos dos fármacos , Sequestradores de Radicais Livres/administração & dosagem , Proteínas de Membrana/biossíntese , Proteínas Recombinantes/administração & dosagem , Superóxido Dismutase/administração & dosagem , Animais , Apoptose/efeitos dos fármacos , Apoptose/efeitos da radiação , Proteínas Reguladoras de Apoptose/biossíntese , Proteínas Reguladoras de Apoptose/genética , Proteínas Reguladoras de Apoptose/efeitos da radiação , Linhagem Celular Tumoral , Feminino , Fibroblastos/patologia , Fibroblastos/efeitos da radiação , Sequestradores de Radicais Livres/farmacologia , Radicais Livres/toxicidade , Expressão Gênica/efeitos dos fármacos , Expressão Gênica/efeitos da radiação , Humanos , Dose Letal Mediana , Camundongos , Camundongos Endogâmicos C57BL , Neoplasias/tratamento farmacológico , Neoplasias/radioterapia , Lesões por Radiação/prevenção & controle , Tolerância a Radiação/efeitos dos fármacos , Radiação Ionizante , Radiossensibilizantes/uso terapêutico , Proteínas Recombinantes/farmacologia , Superóxido Dismutase/farmacologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...