Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 18 de 18
Filtrar
1.
Sci Rep ; 13(1): 2075, 2023 Feb 06.
Artigo em Inglês | MEDLINE | ID: mdl-36747061

RESUMO

This paper presents the first microwave-sensor-node integrated into a short-range wireless sensor network based on ZigBee technology. The node includes an analog front-end circuit, a Frequency Modulated Continuous Wave generator, an Analog-to-Digital-Converter module, a transceiver, a power unit, a processing unit and a new one-port dielectric permittivity sensor which is able to measuring the separation of structural cracks by the reflection coefficient measured in microwave frequencies. The analog front-end is composed of a pair of power dividers, an isolator and a mixer. The dielectric permittivity sensor is based on a patch antenna of variable length. The processing unit and transceiver are implemented with an Arduino UNO and an XBee module respectively. Additionally, the methodology for data processing is presented and the results of the measurement of a synthetic crack are presented. The results show that the system was successfully implemented with a sensitivity of 0.07 GHz/mm, for an opening range of between 0 and 5 mm and for a frequency range ranging from 2.782 GHz to 3.131 GHz. It is important to mention that the measurement was done remotely, placing the sensor 3 m from the client PC.

2.
Biosensors (Basel) ; 12(5)2022 May 02.
Artigo em Inglês | MEDLINE | ID: mdl-35624593

RESUMO

Cardiovascular diseases (CVDs) are the leading cause of death globally. An effective strategy to mitigate the burden of CVDs has been to monitor patients' biomedical variables during daily activities with wearable technology. Nowadays, technological advance has contributed to wearables technology by reducing the size of the devices, improving the accuracy of sensing biomedical variables to be devices with relatively low energy consumption that can manage security and privacy of the patient's medical information, have adaptability to any data storage system, and have reasonable costs with regard to the traditional scheme where the patient must go to a hospital for an electrocardiogram, thus contributing a serious option in diagnosis and treatment of CVDs. In this work, we review commercial and noncommercial wearable devices used to monitor CVD biomedical variables. Our main findings revealed that commercial wearables usually include smart wristbands, patches, and smartwatches, and they generally monitor variables such as heart rate, blood oxygen saturation, and electrocardiogram data. Noncommercial wearables focus on monitoring electrocardiogram and photoplethysmography data, and they mostly include accelerometers and smartwatches for detecting atrial fibrillation and heart failure. However, using wearable devices without healthy personal habits will cause disappointing results in the patient's health.


Assuntos
Fibrilação Atrial , Dispositivos Eletrônicos Vestíveis , Eletrocardiografia , Coração , Humanos , Monitorização Fisiológica/métodos
3.
Sci Rep ; 12(1): 8675, 2022 05 23.
Artigo em Inglês | MEDLINE | ID: mdl-35606407

RESUMO

In this work, a methodology is presented for the determination of the respiration rate of a person under test (PUT), the detection of movements, as well as the elimination of the spurious effects produced by the movements of the PUT. The methodology is based on Empirical Modal Decomposition (EMD) applied to the phase signal obtained by means of a quadrature Doppler radar operating in S band. The EMD allows to automatically eliminate the continuos component (CC) which is present in the phase signal since one of the main characteristics of the modes generated by the EMD is that its mean is equal to zero. On the other hand, the first mode of the EMD is used for the detection of movements while the sum of the second and third modes are used for the elimination of the CC drift caused by the DC drift and the high frequency components produced by the movements of the PUT. The proposed methodology was successfully tested in a PUT at rest and performing movements of the head, arm and combination of head, arm, and torso. The average respiration rate measured was 20.78 breaths / min with a standard deviation of 2.53 breaths/min.


Assuntos
Radar , Taxa Respiratória , Algoritmos , Humanos , Movimento , Respiração , Processamento de Sinais Assistido por Computador , Ultrassonografia Doppler
4.
Biosensors (Basel) ; 12(2)2022 Jan 27.
Artigo em Inglês | MEDLINE | ID: mdl-35200334

RESUMO

The growth of health care spending on older adults with chronic diseases faces major concerns that require effective measures to be adopted worldwide. Among the main concerns is whether recent technological advances now offer the possibility of providing remote health care for the aging population. The benefits of suitable prevention and adequate monitoring of chronic diseases by using emerging technological paradigms such as wearable devices and the Internet of Things (IoT) can increase the detection rates of health risks to raise the quality of life for the elderly. Specifically, on the subject of remote health monitoring in older adults, a first approach is required to review devices, sensors, and wearables that serve as tools for obtaining and measuring physiological parameters in order to identify progress, limitations, and areas of opportunity in the development of health monitoring schemes. For these reasons, a review of articles on wearable devices was presented in the first instance to identify whether the selected articles addressed the needs of aged adults. Subsequently, the direct review of commercial and prototype wearable devices with the capability to read physiological parameters was presented to identify whether they are optimal or usable for health monitoring in older adults.


Assuntos
Internet das Coisas , Dispositivos Eletrônicos Vestíveis , Idoso , Doença Crônica , Atenção à Saúde , Humanos , Pessoa de Meia-Idade , Qualidade de Vida
5.
Healthcare (Basel) ; 10(2)2022 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-35206905

RESUMO

Among mental health diseases, depression is one of the most severe, as it often leads to suicide; due to this, it is important to identify and summarize existing evidence concerning depression sign detection research on social media using the data provided by users. This review examines aspects of primary studies exploring depression detection from social media submissions (from 2016 to mid-2021). The search for primary studies was conducted in five digital libraries: ACM Digital Library, IEEE Xplore Digital Library, SpringerLink, Science Direct, and PubMed, as well as on the search engine Google Scholar to broaden the results. Extracting and synthesizing the data from each paper was the main activity of this work. Thirty-four primary studies were analyzed and evaluated. Twitter was the most studied social media for depression sign detection. Word embedding was the most prominent linguistic feature extraction method. Support vector machine (SVM) was the most used machine-learning algorithm. Similarly, the most popular computing tool was from Python libraries. Finally, cross-validation (CV) was the most common statistical analysis method used to evaluate the results obtained. Using social media along with computing tools and classification methods contributes to current efforts in public healthcare to detect signs of depression from sources close to patients.

6.
Healthcare (Basel) ; 10(2)2022 Feb 08.
Artigo em Inglês | MEDLINE | ID: mdl-35206936

RESUMO

The use of mHealth apps for the self-management of cardiovascular diseases (CVDs) is an increasing trend in patient-centered care. In this research, we conduct a scoping review of mHealth apps for CVD self-management within the period 2014 to 2021. Our review revolves around six main aspects of the current status of mHealth apps for CVD self-management: main CVDs managed, main app functionalities, disease stages managed, common approaches used for data extraction, analysis, management, common wearables used for CVD detection, monitoring and/or identification, and major challenges to overcome and future work remarks. Our review is based on Arksey and O'Malley's methodological framework for conducting studies. Similarly, we adopted the PRISMA model for reporting systematic reviews and meta-analyses. Of the 442 works initially retrieved, the review comprised 38 primary studies. According to our results, the most common CVDs include arrhythmia (34%), heart failure (32%), and coronary heart disease (18%). Additionally, we found that the majority mHealth apps for CVD self-management can provide medical recommendations, medical appointments, reminders, and notifications for CVD monitoring. Main challenges in the use of mHealth apps for CVD self-management include overcoming patient reluctance to use the technology and achieving the interoperability of mHealth applications with other systems.

7.
Sci Rep ; 12(1): 2205, 2022 Feb 09.
Artigo em Inglês | MEDLINE | ID: mdl-35140306

RESUMO

In this work, a sensor in microstrip technology and a methodology for measuring the real part and the imaginary part of the complex uniaxial permittivity of solid anisotropic samples are presented. The sensor is based on a pair of parallel lines coupled resonators and a cleft arranged in the coupling region which allows to hold the samples under test (SUTs). The proposed methodology relates the change in the even/odd resonance frequency with the real part of the permittivity in the vertical/horizontal direction, and the change in the Q factor of the even/odd mode with the imaginary part of the permittivity in the vertical/horizontal direction. The methodology was successfully verified with the characterization, at 2.43 GHz of anisotropic samples of printed PLA, Diclad 880, and RO4350B using the knowns materials: RT5870, PTFE and RO4003.

8.
Biosensors (Basel) ; 13(1)2022 Dec 31.
Artigo em Inglês | MEDLINE | ID: mdl-36671907

RESUMO

Neurodegenerative diseases (NDDs) are among the 10 causes of death worldwide. The effects of NDDs, including irreversible motor impairments, have an impact not only on patients themselves but also on their families and social environments. One strategy to mitigate the pain of NDDs is to early identify and remotely monitor related motor impairments using wearable devices. Technological progress has contributed to reducing the hardware complexity of mobile devices while simultaneously improving their efficiency in terms of data collection and processing and energy consumption. However, perhaps the greatest challenges of current mobile devices are to successfully manage the security and privacy of patient medical data and maintain reasonable costs with respect to the traditional patient consultation scheme. In this work, we conclude: (1) Falls are most monitored for Parkinson's disease, while tremors predominate in epilepsy and Alzheimer's disease. These findings will provide guidance for wearable device manufacturers to strengthen areas of opportunity that need to be addressed, and (2) Of the total universe of commercial wearables devices that are available on the market, only a few have FDA approval, which means that there is a large number of devices that do not safeguard the integrity of the users who use them.


Assuntos
Transtornos Motores , Doenças Neurodegenerativas , Doença de Parkinson , Dispositivos Eletrônicos Vestíveis , Humanos , Tremor
9.
J Food Sci Technol ; 58(4): 1480-1487, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33746276

RESUMO

The knowledge of the dielectric properties of oils is of great importance for several industrial applications, such as microwave-assisted oil frying for foods and high voltage electric power transmission. In this paper, we present the complex permittivity of vegetable oils (canola, olive, soybean, coconut) at 2.50 GHz using the cavity perturbation technique from 28 to 200 °C (temperature close to the smoking point of oils). The measurements were taken with a cylindrical cavity operating at the TE111 mode with an unloaded Q of 4950. In addition, free fatty acids, peroxide index and color were measured before and after heating.

10.
J Food Sci ; 86(3): 952-959, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33580559

RESUMO

Dielectric properties (DPs) of fresh rabbit meat in the microwave range (0.5 to 20 GHz) were determined. Three different muscles (Biceps femoris, Tensor fasciae latae, and Longissimus thoracis) from California rabbits (male and female) were measured with the open-ended coaxial probe method at temperatures of 20, 40, and 60 °C. To assess the possible effect of age, females of 100 and 180 days old were analyzed. DPs were affected by frequency, muscle type, age, gender, and temperature (p < 0.05). Dielectric constant decreased with increasing frequency. Loss factor decreased from 0.5 to 2.5 GHz due to ionic conduction, followed by an increase up to 20 GHz, dominated by dipolar relaxation. PRACTICAL APPLICATION: These results are key parameters for further quality sensing applications and for heating processes of meat rabbit using microwaves. Longer penetration depths were achieved at 915 MHz; this frequency is recommended for further applications. Besides, dielectric properties have potential to be a tool for identification of gender and age for slaughtered rabbits.


Assuntos
Manipulação de Alimentos/métodos , Carne , Micro-Ondas , Músculo Esquelético/química , Animais , Eletroquímica , Feminino , Masculino , Coelhos , Temperatura
11.
J Food Sci ; 86(1): 112-119, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33368317

RESUMO

The dielectric properties and specifically the complex relative permittivity of foods are key elements for the design of pasteurization processes with high frequency electromagnetic waves. Mexican sauces are recognized worldwide for their flavor and nutritional properties. In this work, the complex permittivity of four of the most representative sauces of Mexican cuisine (chipotle chili, habanero chili, red and green sauce) is presented. The permittivity was measured with the open coaxial probe method at temperatures of 25, 40, 55, 70, 85 °C and in the frequency range of 500 MHz to 6 GHz. Additionally, moisture content, specific heat, viscosity, water activity, density and electrical conductivity are reported, these last three at 25 °C. Dielectric properties were affected by the sauce formulation. The loss factor of each sauce sample at any temperature presents significant changes in relation to the frequency. At 915 and 2,450 MHz, d ε ' ' d T > 0 , which would cause a thermal runaway effect or the uncontrolled rise in temperature in the sauces during the microwave pasteurization. At 5,800 MHz, d ε ' ' d T < 0 , which would give better control for microwave heating than at 915 and 2,450 MHz. At 915 MHz, the loss factor of all sauces is higher than at 2,450 and 5,800 MHz, therefore, more rapid heating can be produced. Moreover, at 915 MHz, microwaves exhibit higher penetration depth than at 2,450 and 5,800 MHz; therefore, at 915 MHz, the greatest uniform microwave dielectric heating would be achieved. Thus, 915 MHz is the frequency recommended for the studied sauces pasteurization. PRACTICAL APPLICATION: This work provides the dielectric properties of Mexican sauces at different temperatures and their penetration depths in the microwave range, which are key information for further microwave-assisted pasteurization process and for getting safer sauces for consumers. Moreover, this research supplies suggestions about what frequency for ISM (Industrial, Scientific and Medical) applications is the best for microwave-assisted pasteurization according to the penetration depth of the electromagnetic wave in the sauces and microwave dielectric heating speed of the sauces.


Assuntos
Condimentos/análise , Análise de Alimentos/métodos , Calefação , Micro-Ondas , Pasteurização/métodos , Temperatura
12.
J Food Sci ; 83(9): 2317-2323, 2018 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-30085360

RESUMO

Dielectric properties (DPs) of two beverages, tamarind and a green drink (based on mix fruits of pineapple, guava, lemon, and nopal), were studied. The DPs were determined using the open-ended coaxial probe method in the frequency range from 0.25 to 25 GHz at 10, 30, 50, and 70 °C. The dielectric constant decreased when both frequency and temperature increased above 1000 MHz. For both beverages, the dielectric loss factor increased with increasing frequency and increasing temperature. In addition, dielectric constant values ranged from 59.7 to 82.5, and the dielectric loss factors were between 5.8 and 31.1. The penetration depth (dp ) of electromagnetic waves in the beverages increased proportionally to temperature at frequencies above 1000 MHz; dp values ranged from 0.2 to 7.5 cm. Because of its complexity and the amount of ingredients and the interactions between them, the green drink showed higher values of dielectric constants in comparison with the tamarind beverage. PRACTICAL APPLICATION: The dielectric properties of the studied beverages, how they behave at different temperatures, and the penetration depth reached by microwave at the allocated frequencies, provide important parameters for further heating treatments, such as heating (microwave-assisted pasteurization) and for modeling/simulation purposes.


Assuntos
Eletricidade , Sucos de Frutas e Vegetais/análise , Frutas , Micro-Ondas , Tamarindus , Ananas , Bebidas , Citrus , Cor , Humanos , Opuntia , Pasteurização , Psidium , Temperatura
13.
J Food Sci Technol ; 55(8): 3119-3126, 2018 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-30065422

RESUMO

For microwave heating pasteurization processes, knowledge of the dielectric characteristics of foods are very important. In this paper, we present the dielectric properties of raw soy milk and commercial packed soy milk of four different flavors (light, natural, chocolate and pecan) from 500 MHz to 20 GHz, covering most of the assigned frequencies by the Federal Communications Commission for heating purposes. Experiments were performed using an open-ended-coaxial probe and a vector network analyzer. This characterization was carried out for temperatures ranging from 20 to 70 °C in steps of 10 °C. The dielectric constant of soy milks decreased with increasing frequency, while increasing temperature resulted in decreasing of the values. The dielectric loss factor presents a U shape behavior, where the loss started decreasing from 500 MHz to about 3 GHz and then, it increased again up to 20 GHz. In addition, higher temperatures decreased the dielectric loss. Applying the higher order Debye´s equation, two relaxation times were calculated for the soymilks, with good agreement with the measured properties. Deeper penetration of microwaves were obtained for raw soy milk at 915 MHz, making it suitable for microwave pasteurization.

14.
PLoS One ; 13(6): e0198621, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29927958

RESUMO

Antimicrobial resistance is an increasing worldwide concern, which poses unique challenges for the effective prevention and treatment of several infections, especially the ones triggered by organisms producing extended-spectrum ß-lactamases (ESBL). Here, we present the surveillance results of the Study for Monitoring Antimicrobial Resistance Trends (SMART) of Gram-negative bacilli isolated from intra-abdominal infections (IAI, n = 1,235) and urinary-tract infections (UTI, n = 2,682), collected in Mexico from 2009 to 2015. Susceptibility and ESBL status were determined according to the Clinical and Laboratory Standards Institute (CLSI) broth microdilution method. Both E. coli (57%) and K. pneumoniae (12%) were the most frequently reported organisms, as well as the ones with the highest prevalence of ESBL-producing isolates (54% and 39%, respectively). The overall prevalence of ESBL-producing organisms was higher in nosocomial infections than in community-acquired infections (21% vs. 27%). The ESBL rates were 36% for IAI (953/2,682) and 37% for UTI (461/1,235). In addition, ertapenem, imipenem and amikacin were the antibiotics that mostly preserved bacterial susceptibility. Our results show consistency with global trends, although higher than the rates observed in Latin America.


Assuntos
Anti-Infecciosos/farmacologia , Bactérias Gram-Negativas/efeitos dos fármacos , Infecções Intra-Abdominais/microbiologia , Infecções Urinárias/microbiologia , Anti-Infecciosos/uso terapêutico , Resistência Microbiana a Medicamentos , Humanos , Infecções Intra-Abdominais/tratamento farmacológico , México , Infecções Urinárias/tratamento farmacológico
15.
J Food Sci Technol ; 52(12): 8403-9, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26604422

RESUMO

Dielectric properties of barley, corn (white and yellow), sorghum, and wheat at microwave frequencies for heating purpose were analyzed. Properties were determined at 915, 2450 and 5800 MHz with the free space transmission method in the cereals at 20, 30, 40, 50 and 60 °C. ε´ and ε"of all the cereals decreased with increasing frequency. ε´ slightly increased with temperature, while ε "remained practically constant for all the cereals in the temperature range from 20 to 60 °C. Penetration depth decreased with increasing frequency for all the samples, and increased with increasing temperature at 915 MHz, except for barley. These results are useful for further microwave heating applications for the studies on cereals.

16.
Curr Med Res Opin ; 29(4): 379-86, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23323877

RESUMO

OBJECTIVE: The most prevalent dyslipidemias in Mexico are low high-density lipoprotein (HDL) and high triglyceride (TG) levels. Hypertriglyceridemia (HTG) has been considered an independent risk factor for cardiovascular disease (CVD). The aim of this study was to evaluate the efficacy of rosuvastatin (RSV) in reducing TG levels in Mexican patients. METHODS: A randomized, double-blind, double-dummy, parallel-group, placebo-controlled, multicenter, phase IV study was conducted. Patients were of both genders, ≥ 18 years old, with basal TG levels between 200 and 800 mg/dl, LDL levels ≤ 190 mg/dl. Patients were randomized to receive rosuvastatin 10 mg (Group 1), 20 mg (Group 2) or placebo (Group 3) once daily for 8 weeks. Primary efficacy was TG level; secondary efficacy was non-HDL; HDL, low-density lipoprotein (LDL), total cholesterol (TC), Apo (apolipoprotein) A1, and ApoB. Safety data were evaluated up to 30 days after the last dose of medication. The Mann-Whitney U-test was performed to contrast each RSV groups against placebo; p < 0.05 was considered significant. Trial registry number is NCT00473655. RESULTS: A total of 334 patients were randomized: Group 1 = 111, Group 2 = 112, and Group 3 = 111. Basal TG median value levels were 278 mg/dl, 266 mg/dl, 279 mg/dl with median reduction (MdR) at 8 weeks of 26.6%, 32.19% and 7.58%, respectively, (Group 1 vs. Group 3 p = 0.002, and Group 2 vs. Group 3 p < 0.0001). Basal non-HDL values were 179 mg/dl, 180 mg/dl and 179 mg/dl with a MdR of 27%, 32% and 8%, respectively (Group 1 vs. Group 3 p < 0.0001, and Group 2 vs. Group 3 p < 0.0001); basal LDL vales were 130 mg/dl, 130 mg/dl and 127 mg/dl with MdR 35%, 44% and -4% (Group 1 vs. Group 3 p < 0.0001, Group 2 vs. Group 3 p < 0.0001); basal ApoB values were 114 mg/dl, 115 mg/dl and 110.5 mg/dl with MdR 25%, 33% and -0.5% (Group 1 vs. Group 3 p < 0.0001, Group 2 vs. Group 3 p < 0.001). CONCLUSION: Rosuvastatin 10 and 20 mg/day significantly reduced triglycerides and improved atherogenic lipid profile in HTG Mexican patients. The main limitation was the short follow-up time period.


Assuntos
Doenças Cardiovasculares/sangue , Doenças Cardiovasculares/tratamento farmacológico , Fluorbenzenos/uso terapêutico , Inibidores de Hidroximetilglutaril-CoA Redutases/uso terapêutico , Pirimidinas/uso terapêutico , Sulfonamidas/uso terapêutico , Apolipoproteína A-I/sangue , Apolipoproteínas B/sangue , Colesterol/sangue , Método Duplo-Cego , Feminino , Humanos , Hipertrigliceridemia/sangue , Hipertrigliceridemia/tratamento farmacológico , Lipoproteínas HDL/sangue , Lipoproteínas LDL/sangue , Masculino , Síndrome Metabólica/sangue , Síndrome Metabólica/tratamento farmacológico , México , Pessoa de Meia-Idade , Rosuvastatina Cálcica , Triglicerídeos/sangue
17.
Inform Health Soc Care ; 37(2): 74-91, 2012 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22462196

RESUMO

Emergency healthcare is one of the emerging application domains for information services, which requires highly multimodal information services. The time of consuming pre-hospital emergency process is critical. Therefore, the minimization of required time for providing primary care and consultation to patients is one of the crucial factors when trying to improve the healthcare delivery in emergency situations. In this sense, dynamic location of medical entities is a complex process that needs time and it can be critical when a person requires medical attention. This work presents a multimodal location-based system for locating and assigning medical entities called ITOHealth. ITOHealth provides a multimodal middleware-oriented integrated architecture using a service-oriented architecture in order to provide information of medical entities in mobile devices and web browsers with enriched interfaces providing multimodality support. ITOHealth's multimodality is based on the use of Microsoft Agent Characters, the integration of natural language voice to the characters, and multi-language and multi-characters support providing an advantage for users with visual impairments.


Assuntos
Informação de Saúde ao Consumidor/métodos , Serviços de Saúde , Sistemas de Informação/organização & administração , Internet , Integração de Sistemas , Canadá , Telefone Celular , Redes de Comunicação de Computadores , Serviços Médicos de Emergência , Humanos , Fatores de Tempo , Interface Usuário-Computador
18.
Arch. Inst. Cardiol. Méx ; 57(5): 363-73, sept.-oct. 1987. tab, ilus
Artigo em Espanhol | LILACS | ID: lil-66302

RESUMO

Con el fin de conocer los resultados tempranos y tardíos de la pericardiectomía en el tratamiento de la pericarditis constrictiva, en el Instituo Nacional de Cardiología Ignaci Chávez de México, revisamos los expedientes de 58 enfermos, que se sometieron a esta investigación entre 1947 y 1986. Los factores etiológiocos más frecuentes fueron la tuberculosis y el origen idiopático (en 68.3% y 24.1% respectivamente). Antes de la intervención quirúrgica el 3.4% de los pacientes estaban en clase funcional I de la New York Heart Association, 31% en clase II, 48,3% en clase III y 16.2% en clase IV. La mortalidad operativa global fue del 6.89% y en la última década fue del 0%. La complicación operatoria más frecuente fue el bajo gasto, que ocurrió en el 15.5% de los pacientes. El desgarro accidental de la aurícula derecha ocurrió en el 8.6% de los casos. El tiempo de seguimiento fue de 5.6 ñ 6.3 años (con un máximo de 25.6 años). La mortalidad por paciente y año fue del 2.04%. La supervivencia a los cinco y diez años, excluida la mortalidad operatoria fue de 82% y 71% respectivamente. Después de la pericardiectomía el 76% de los enfermos estaba en clase funcional I de la New York Heart Association (p <0.001), el 16% en clase II (p <0.001), el 8% en clase III (p <0.001) y el 0% en clase IV (p <0.05). No hubo correlación entre la clase IV funcional preoperatoria ni la duración de los síntomas antes del diagnóstico y la mortalidad temprana y tardía, y la clase funcional postoperatoria. Se concluye que la pericardiectomía es el tratamiento de elección en la pericarditis constrictiva sintomática, al producir una importante y duradera mejoría en los síntomas y en la capacidad funcional, con una baja mortalidad operatoria, sobre todo en la última década


Assuntos
Pré-Escolar , Criança , Adolescente , Adulto , Pessoa de Meia-Idade , Humanos , Masculino , Feminino , Pericardiectomia , Pericardite Constritiva/cirurgia , Seguimentos , Pericardite Constritiva/etiologia , Complicações Pós-Operatórias
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...