1.
Rev Sci Instrum ; 87(4): 045004, 2016 04.
Artigo em Inglês | MEDLINE | ID: mdl-27131699

RESUMO

The parasitic effects from electromechanical resonance, coupling, and substrate losses were collected to derive a new two-port equivalent-circuit model for Lamb wave resonators, especially for those fabricated on silicon technology. The proposed model is a hybrid π-type Butterworth-Van Dyke (PiBVD) model that accounts for the above mentioned parasitic effects which are commonly observed in Lamb-wave resonators. It is a combination of interdigital capacitor of both plate capacitance and fringe capacitance, interdigital resistance, Ohmic losses in substrate, and the acoustic motional behavior of typical Modified Butterworth-Van Dyke (MBVD) model. In the case studies presented in this paper using two-port Y-parameters, the PiBVD model fitted significantly better than the typical MBVD model, strengthening the capability on characterizing both magnitude and phase of either Y11 or Y21. The accurate modelling on two-port Y-parameters makes the PiBVD model beneficial in the characterization of Lamb-wave resonators, providing accurate simulation to Lamb-wave resonators and oscillators.

2.
Artigo em Inglês | MEDLINE | ID: mdl-21097028

RESUMO

A 1.8-mW, 18.5-mm(2) 64-channel current readout ASIC was implemented in 0.18-µm CMOS together with a new calibration scheme for silicon nanowire biosensor arrays. The ASIC consists of 64 channels of dedicated readout and conditioning circuits which incorporate correlated double sampling scheme to reduce the effect of 1/f noise and offset from the analog front-end. The ASIC provides a 10-bit digital output with a sampling rate of 300 S/s whilst achieving a minimum resolution of 7 pA(rms). A new electrical calibration method was introduced to mitigate the issue of large variations in the nano-scale sensor device parameters and optimize the sensor sensitivity. The experimental results show that the proposed calibration technique improved the sensitivity by 2 to 10 times and reduced the variation between dataset by 9 times.


Assuntos
Conversão Análogo-Digital , Técnicas Biossensoriais/instrumentação , Condutometria/instrumentação , Análise em Microsséries/instrumentação , Nanotubos/química , Processamento de Sinais Assistido por Computador/instrumentação , Técnicas Biossensoriais/normas , Calibragem , Condutometria/normas , Desenho de Equipamento , Análise de Falha de Equipamento , Análise em Microsséries/normas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...