Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Med J Aust ; 220(10): 510-516, 2024 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-38711337

RESUMO

OBJECTIVES: To quantify the rate of cardiac implantable electronic device (CIED)-related infections and to identify risk factors for such infections. DESIGN: Retrospective cohort study; analysis of linked hospital admissions and mortality data. SETTING, PARTICIPANTS: All adults who underwent CIED procedures in New South Wales between 1 January 2016 and 30 June 2021 (public hospitals) or 30 June 2020 (private hospitals). MAIN OUTCOME MEASURES: Proportions of patients hospitalised with CIED-related infections (identified by hospital record diagnosis codes); risk of CIED-related infection by patient, device, and procedural factors. RESULTS: Of 37 675 CIED procedures (23 194 men, 63.5%), 500 were followed by CIED-related infections (median follow-up, 24.9 months; interquartile range, 11.2-40.8 months), including 397 people (1.1%) within twelve months of their procedures, and 186 of 10 540 people (2.5%) at high risk of such infections (replacement or upgrade procedures; new cardiac resynchronisation therapy with defibrillator, CRT-D). The overall infection rate was 0.50 (95% confidence interval [CI], 0.45-0.54) per 1000 person-months; it was highest during the first month after the procedure (5.60 [95% CI, 4.89-6.42] per 1000 person-months). The risk of CIED-related infection was greater for people under 65 years of age than for those aged 65-74 years (adjusted hazard ratio [aHR], 1.71; 95% CI, 1.32-2.23), for people with CRT-D devices than for those with permanent pacemakers (aHR, 1.46; 95% CI, 1.02-2.08), for people who had previously undergone CIED procedures (two or more v none: aHR, 1.51; 95% CI, 1.02-2.25) or had CIED-related infections (aHR, 11.4; 95% CI, 8.34-15.7), or had undergone concomitant cardiac surgery (aHR, 1.62; 95% CI, 1.10-2.39), and for people with atrial fibrillation (aHR, 1.33; 95% CI, 1.11-1.60), chronic kidney disease (aHR, 1.54; 95% CI, 1.27-1.87), chronic obstructive pulmonary disease (aHR, 1.37; 95% CI, 1.10-1.69), or cardiomyopathy (aHR 1.60; 95% CI, 1.25-2.05). CONCLUSIONS: Knowledge of risk factors for CIED-related infections can help clinicians discuss them with their patients, identify people at particular risk, and inform decisions about device type, upgrades and replacements, and prophylactic interventions.


Assuntos
Desfibriladores Implantáveis , Infecções Relacionadas à Prótese , Humanos , Masculino , Estudos Retrospectivos , Feminino , Idoso , New South Wales/epidemiologia , Desfibriladores Implantáveis/efeitos adversos , Desfibriladores Implantáveis/estatística & dados numéricos , Infecções Relacionadas à Prótese/epidemiologia , Infecções Relacionadas à Prótese/etiologia , Pessoa de Meia-Idade , Fatores de Risco , Idoso de 80 Anos ou mais , Marca-Passo Artificial/efeitos adversos , Marca-Passo Artificial/estatística & dados numéricos , Adulto , Hospitalização/estatística & dados numéricos
2.
Europace ; 25(9)2023 08 02.
Artigo em Inglês | MEDLINE | ID: mdl-37703326

RESUMO

AIMS: An infection following cardiac implantable electronic device (CIED) procedure is a serious complication, but its association with all-cause mortality is inconsistent across observational studies. To quantify the association between CIED infection and all-cause mortality in a large, contemporary cohort from New South Wales, Australia. METHODS AND RESULTS: This retrospective cohort study used linked hospital and mortality data and included all patients aged >18 years who underwent a CIED procedure between July 2017 and September 2022. Cardiac implantable electronic device infection was defined by the presence of relevant diagnosis codes. Cox regression to estimate adjusted hazard ratios (aHRs) with 95% confidence intervals (CIs) for the association of CIED infection with mortality, at 1-year, and at the end of follow-up, with CIED infection included as a time-dependent variable, and other potential risk factors for mortality included as fixed covariates. We followed 37,750 patients with CIED procedures {36% female, mean age [standard deviation (SD)] 75.8 [12.7] years}, and 487 (1.3%) CIED infections were identified. We observed 5771 (15.3%) deaths during an average follow-up of 25.2 (SD 16.8) months. Compared with no infection group, patients with CIED infection had a higher Kaplan-Meier mortality rate (19.4 vs. 6.8%) and adjusted hazard of mortality (aHR 2.73, 95% CI 2.10-3.54) at 12 months post-procedure. These differences were attenuated but still remained significant at the end of follow-up (aHR 1.83, 95% CI 1.52-2.19). CONCLUSION: In a complete, state-wide cohort of CIED patients, infection was associated with higher risks of both short-term and long-term mortality.


Assuntos
Eletrônica , Cardiopatias , Feminino , Humanos , Masculino , Austrália , Hospitais , Estudos Retrospectivos , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais
SELEÇÃO DE REFERÊNCIAS