Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 99
Filtrar
1.
Adv Healthc Mater ; : e2401213, 2024 Jun 10.
Artigo em Inglês | MEDLINE | ID: mdl-38856313

RESUMO

The recent decade has witnessed a remarkable surge in the field of nanoparticles, from their synthesis, characterization, and functionalization to diverse applications. At the nanoscale, these particles exhibit distinct physicochemical properties compared to their bulk counterparts, enabling a multitude of applications spanning energy, catalysis, environmental remediation, biomedicine, and beyond. This review focuses on specific nanoparticle categories, including magnetic, gold, silver, and quantum dots (QDs), as well as hybrid variants, specifically tailored for biomedical applications. A comprehensive review and comparison of prevalent chemical, physical, and biological synthesis methods are presented. To enhance biocompatibility and colloidal stability, and facilitate surface modification and cargo/agent loading, nanoparticle surfaces are coated with different synthetic polymers and very recently, cell membrane coatings. The utilization of polymer- or cell membrane-coated nanoparticles opens a wide variety of biomedical applications such as magnetic resonance imaging (MRI), hyperthermia, photothermia, sample enrichment, bioassays, drug delivery, etc. With this review, the goal is to provide a comprehensive toolbox of insights into polymer or cell membrane-coated nanoparticles and their biomedical applications, while also addressing the challenges involved in translating such nanoparticles from laboratory benchtops to in vitro and in vivo applications. Furthermore, perspectives on future trends and developments in this rapidly evolving domain are provided.

2.
Nanoscale ; 16(14): 7041-7057, 2024 Apr 04.
Artigo em Inglês | MEDLINE | ID: mdl-38444246

RESUMO

Magnetic nanoparticles (MNPs) have recently gained significant attention in various fields, including chemical and biomedical applications, due to their exceptional properties. However, separating MNPs from solution via magnetophoresis is challenging when MNPs are smaller than 50 nm as Brownian forces become on the order of the magnetic forces. In this study, we successfully separated small MNPs (5-30 nm) by utilizing high magnetic fields and gradients generated by economical permanent magnets. In situ small angle X-ray scattering (SAXS) was used to investigate the time-dependent concentration changes in the ferrofluid, and the results validated that only the 30 nm particles experienced particle aggregation or agglomeration, indicating that dipole-dipole interactions did not play a discernable role in the separation process for particles smaller than ∼15 nm. However, numerical simulations have provided further validation that in the absence of particle-particle interactions, even MNPs with diameters less than 15 nm exhibited magnetophoresis that effectively counteracted the effects of Brownian motion.

3.
Electrophoresis ; 2023 Dec 02.
Artigo em Inglês | MEDLINE | ID: mdl-38041407

RESUMO

Precisely and accurately determining the magnetic force and its spatial distribution in microfluidic devices is challenging. Typically, magnetic microfluidic devices are designed in a way to both maximize the force within the separation region and to minimize the necessity for knowing such details-such as designing magnetic geometries that create regions of nearly constant magnetic force or that dictate the behavior of the magnetic force to be highly predictable in a specified region. In this work, we present a method to determine the spatial distribution of the magnetic force field in a magnetic microfluidic device by particle tracking magnetophoresis. Polystyrene microparticles were suspended in a paramagnetic fluid, gadolinium, and this suspension was exposed to various magnetic field geometries. Polystyrene particle motion was tracked using a microscope and images processed using Fiji (ImageJ). From a sample with a large spatial distribution of particle tracks, the magnetic force field distribution was calculated. The force field distribution was fitted to nonlinear spatial distribution models. These experimental models are compared to and supported by 3D simulations of the magnetic force field in COMSOL.

4.
Micromachines (Basel) ; 14(11)2023 Nov 17.
Artigo em Inglês | MEDLINE | ID: mdl-38004965

RESUMO

Superparamagnetic iron oxide nanoparticles (SPIONs) have gathered tremendous scientific interest, especially in the biomedical field, for multiple applications, including bioseparation, drug delivery, etc. Nevertheless, their manipulation and separation with magnetic fields are challenging due to their small size. We recently reported the coupling of cooperative magnetophoresis and sedimentation using quadrupole magnets as a promising strategy to successfully promote SPION recovery from media. However, previous studies involved SPIONs dispersed in organic solvents (non-biocompatible) at high concentrations, which is detrimental to the process economy. In this work, we investigate, for the first time, the magnetic separation of 20 nm and 30 nm SPIONs dispersed in an aqueous medium at relatively low concentrations (as low as 0.5 g·L-1) using our custom, permanent magnet-based quadrupole magnetic sorter (QMS). By monitoring the SPION concentrations along the vessel within the QMS, we estimated the influence of several variables in the separation and analyzed the kinetics of the process. The results obtained can be used to shed light on the dynamics and interplay of variables that govern the fast separation of SPIONs using inexpensive permanent magnets.

5.
Nat Commun ; 14(1): 1975, 2023 04 08.
Artigo em Inglês | MEDLINE | ID: mdl-37031202

RESUMO

Persistent HPV16 infection is a major cause of the global cancer burden. The viral life cycle is dependent on the differentiation program of stratified squamous epithelium, but the landscape of keratinocyte subpopulations which support distinct phases of the viral life cycle has yet to be elucidated. Here, single cell RNA sequencing of HPV16 infected compared to uninfected organoids identifies twelve distinct keratinocyte populations, with a subset mapped to reconstruct their respective 3D geography in stratified squamous epithelium. Instead of conventional terminally differentiated cells, an HPV-reprogrammed keratinocyte subpopulation (HIDDEN cells) forms the surface compartment and requires overexpression of the ELF3/ESE-1 transcription factor. HIDDEN cells are detected throughout stages of human carcinogenesis including primary human cervical intraepithelial neoplasias and HPV positive head and neck cancers, and a possible role in promoting viral carcinogenesis is supported by TCGA analyses. Single cell transcriptome information on HPV-infected versus uninfected epithelium will enable broader studies of the role of individual keratinocyte subpopulations in tumor virus infection and cancer evolution.


Assuntos
Carcinoma de Células Escamosas , Proteínas Oncogênicas Virais , Infecções por Papillomavirus , Feminino , Humanos , Papillomavirus Humano 16/genética , Papillomavirus Humano 16/metabolismo , Transcriptoma , Epitélio/metabolismo , Queratinócitos/metabolismo , Carcinogênese/genética , Carcinoma de Células Escamosas/genética , Proteínas Oncogênicas Virais/genética
6.
IEEE Trans Biomed Eng ; 69(12): 3582-3590, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-35544484

RESUMO

Sickle cell disease (SCD) is an inherited blood disorder that affects millions of people worldwide, especially in low-resource regions of the world, where a rapid and affordable test to properly diagnose the disease would be highly valued. Magnetophoresis is a technique that could simultaneously analyze, quantify, and potentially separate the patient's sickle red blood cells (RBCs) from healthy RBCs, but the magnetic characteristics of sickle RBCs have yet to be reported. In this work, we present the single cell magnetic characterization of RBCs obtained from SCD patients. Sufficient single cells are analyzed from patient samples undergoing transfusion therapy and not yet having transfusion therapy (TP and NTP, respectively), such that means and distributions of these single RBC mobilities are created in the form of histograms which facilitated comparison to RBCs from healthy donors (HD). The magnetic characterization is obtained using a technique known as Cell Tracking Velocimetry (CTV) that quantitatively characterizes the RBC response to magnetic and gravitational fields. The magnetic properties of RBCs containing oxygenated, deoxygenated hemoglobin (Hb) and methemoglobin (oxyHb-RBCs, deoxyHb-RBCs, and metHb-RBCs) are further determined. The NTP samples reported the highest magnetic character, especially when compared to oxyHb-RBCs from HD, which implies impaired oxygen binding capabilities. Also, the oxygen-Hb equilibrium curves are obtained to estimate the magnetic character of the cells under intermediate oxygen levels. Our results confirm higher magnetic moment of SCD blood (NTP) under intermediate oxygen levels. These data demonstrate the potential feasibility of magnetophoresis to identify, quantify and separate sickle RBCs from healthy RBCs.


Assuntos
Anemia Falciforme , Eritrócitos , Humanos , Anemia Falciforme/terapia , Anemia Falciforme/metabolismo , Oxigênio/metabolismo , Fenômenos Magnéticos
7.
Vox Sang ; 117(6): 803-811, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35262216

RESUMO

BACKGROUND AND OBJECTIVES: Red blood cell (RBC) units in hypothermic storage degrade over time, commonly known as the RBC storage lesion. These older RBC units can cause adverse clinical effects when transfused, as older RBCs in the unit lyse and release cell-free haemoglobin (Hb), a potent vasodilator that can elicit vasoconstriction, systemic hypertension and oxidative tissue injury after transfusion. In this study, we examined a novel method of washing ex vivo stored single RBC units to remove accumulated cellular waste, specifically cell-free Hb, using tangential flow filtration (TFF) driven by a centrifugal pump. MATERIALS AND METHODS: The TFF RBC washing system was run under hypothermic conditions at 4°C, at a constant system volume with 0.9 wt% saline as the wash solution. The RBC washing process was conducted on 10 separate RBC units. For this proof-of-concept study, RBC units were expired at the time of washing (60-70 days old). Cell-free Hb was quantified by UV-visible absorbance spectroscopy and analysed via the Winterbourn equations. Pre- and post-wash RBC samples were analysed by Hemox Analyser, Coulter counter and Brookfield rheometer. The RBC volume fraction in solution was measured throughout the wash process by standard haematocrit (HCT) analysis. RESULTS: No substantial decrease in the HCT was observed during the TFF RBC washing process. However, there was a significant decrease in RBC concentration in the first half of the TFF RBC wash process, with no significant change in RBC concentration during the second half of the TFF cell wash process with an 87% overall cell recovery compared with the total number of cells before initiation of cell washing. Utilization of the extinction coefficients and characteristic peaks of each Hb species potentially present in solution was quantified by Winterbourn analysis on retentate and permeate samples for each diacycle to quantify Hb concentration during the washing process. Significant cell-free Hb reduction was observed within the first four diacycles with a starting cell-free Hb concentration in the RBC unit of 0.105 mM, which plateaus to a constant Hb concentration of 0.01 mM or a total extracellular Hb mass of 0.2 g in the resultant washed unit. The oxygen equilibrium curve showed a significant decrease in P50 between the initial and final RBC sample cell wash with an initial P50 of 15.6 ± 1.8 mm Hg and a final P50 of 14 ± 1.62 mm Hg. Cooperativity increased after washing from an initial Hill coefficient of 2.37 ± 0.19 compared with a final value of 2.52 ± 0.12. CONCLUSION: Overall, this study investigated the proof-of-concept use of TFF for washing single RBC units with an emphasis on the removal of cell-free Hb from the unit. Compared with traditional cell washing procedures, the designed system was able to more efficiently remove extracellular Hb but resulted in longer wash times. For a more complete investigation of the TFF RBC washing process, further work should be done to investigate the effects of RBC unit storage after washing. The designed system is lightweight and transportable with the ability to maintain sterility between uses, providing a potential option for bedside ex vivo transfusion in clinical applications.


Assuntos
Preservação de Sangue , Eritrócitos , Preservação de Sangue/métodos , Filtração , Hematócrito , Hemoglobinas/análise , Humanos , Solução Salina
8.
Sci Rep ; 12(1): 1692, 2022 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-35105914

RESUMO

Anemia and iron deficiency continue to be the most prevalent nutritional disorders in the world, affecting billions of people in both developed and developing countries. The initial diagnosis of anemia is typically based on several markers, including red blood cell (RBC) count, hematocrit and total hemoglobin. Using modern hematology analyzers, erythrocyte parameters such as mean corpuscular volume (MCV), mean corpuscular hemoglobin (MCH), etc. are also being used. However, most of these commercially available analyzers pose several disadvantages: they are expensive instruments that require significant bench space and are heavy enough to limit their use to a specific lab and lead to a delay in results, making them less practical as a point-of-care instrument that can be used for swift clinical evaluation. Thus, there is a need for a portable and economical hematology analyzer that can be used at the point of need. In this work, we evaluated the performance of a system referred to as the cell tracking velocimetry (CTV) to measure several hematological parameters from fresh human blood obtained from healthy donors and from sickle cell disease subjects. Our system, based on the paramagnetic behavior that deoxyhemoglobin or methemoglobin containing RBCs experience when suspended in water after applying a magnetic field, uses a combination of magnets and microfluidics and has the ability to track the movement of thousands of red cells in a short period of time. This allows us to measure not only traditional RBC indices but also novel parameters that are only available for analyzers that assess erythrocytes on a cell by cell basis. As such, we report, for the first time, the use of our CTV as a hematology analyzer that is able to measure MCV, MCH, mean corpuscular hemoglobin concentration (MCHC), red cell distribution width (RDW), the percentage of hypochromic cells (which is an indicator of insufficient marrow iron supply that reflects recent iron reduction), and the correlation coefficients between these metrics. Our initial results indicate that most of the parameters measured with CTV are within the normal range for healthy adults. Only the parameters related to the red cell volume (primarily MCV and RDW) were outside the normal range. We observed significant discrepancies between the MCV measured by our technology (and also by an automated cell counter) and the manual method that calculates MCV through the hematocrit obtained by packed cell volume, which are attributed to the artifacts of plasma trapping and cell shrinkage. While there may be limitations for measuring MCV, this device offers a novel point of care instrument to provide rapid RBC parameters such as iron stores that are otherwise not rapidly available to the clinician. Thus, our CTV is a promising technology with the potential to be employed as an accurate, economical, portable and fast hematology analyzer after applying instrument-specific reference ranges or correction factors.


Assuntos
Anemia Falciforme/sangue , Rastreamento de Células/instrumentação , Índices de Eritrócitos , Citometria de Fluxo/instrumentação , Microfluídica/instrumentação , Adulto , Estudos de Casos e Controles , Confiabilidade dos Dados , Contagem de Eritrócitos , Eritrócitos , Feminino , Hematócrito , Hemoglobinas/análise , Humanos , Campos Magnéticos , Masculino , Pessoa de Meia-Idade , Valores de Referência , Adulto Jovem
9.
Sep Purif Technol ; 2802022 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-35035269

RESUMO

Superparamagnetic iron oxide nanoparticles (SPIONs) are currently popular materials experiencing rapid development with potential application value, especially in biomedical and chemical engineering fields. Examples include wastewater management, bio-detection, biological imaging, targeted drug delivery and biosensing. While not exclusive, magnetically driven isolation methods are typically required to separate the desired entity from the media in specific applications and in their manufacture and/or quality control. However, due to the nano-size of SPIONs, their magnetic manipulation is affected by Brownian motion, adding considerable complexities. The two most common methods for SPION magnetic separation are high and low gradient magnetic separation (HGMS and LGMS, respectively). Nevertheless, the effect of specific magnetic energy fields on SPIONs, such as horizontal (perpendicular to gravity), high fields and gradients (higher than LGMS) on the horizontal magnetophoresis and vertical sedimentation of SPIONs has only recently been suggested as a way to separate very small particles (5 nm). In this work, we continue those studies on the magnetic separation of 5-30 nm SPIONs by applying fields and gradients perpendicular to gravity. The magnetic field was generated by permanent magnets arranged in quadrupolar configurations (QMS). Different conditions were studied, and multiple variables were evaluated, including the particle size, the initial SPIONs concentration, the temperature, the magnetic field gradient and the magnetic exposure time. Our experimental data show that particles are subjected to horizontal magnetic forces, to particle agglomeration due to dipole-dipole interactions, and to vertical sedimentation due to gravity. The particle size and the type of separator employed (i.e. different gradient and field distribution acting on the particle suspension) have significant effects on the phenomena involved in the separation, whereas the temperature and particle concentration affect the separation to a lesser extent. Finally, the separation process was observed to occur in less than 3 mins for our experimental conditions, which is encouraging considering the long operation time (up to days) necessary to separate particles of similar sizes in LGMS columns that also employ permanent magnets.

10.
Ind Eng Chem Res ; 60(46): 16780-16790, 2021 Nov 24.
Artigo em Inglês | MEDLINE | ID: mdl-34866775

RESUMO

The design of microdevices in which components with magnetic character must be separated and recovered from reactive media benefits from the advantages of microfluidics and meets the criteria for process intensification; however, there are open questions, such as the design of the most appropriate magnet arrangement, that need further research in order to increase the magnetic gradient exerted on the particles. Herein, we focus on the continuous recovery of magnetic microparticles, that can be used as support to facilitate the recovery of biocatalysts (magnetic microcatalysts, MMCs) from biological fluids. We analyze and compare the performance of two typical magnetophoretic microdevices for addressing bead recovery: (i) annular channels with a quadrupole orientation of the permanent magnets (quadrupole magnetic sorter, QMS) and (ii) the standard design, which consists of rectangular channels with a single permanent magnet to generate the magnetic field. To this end, an experimentally validated computational fluid dynamics (CFD) numerical model has been employed. Our results reveal that for devices with the same width and length, the micro-QMS, in comparison to a rectangular channel, could accomplish the complete particle retrieval while (i) processing more than 4 times higher fluid velocities, treating more than 360 times higher flow rates or (ii) working with smaller particles, thus reducing by 55% the particle mass. Additionally, the parallel performance of ≈300 micro-QMSs fulfills the processing of flow rates as high as 200 L·h-1 while entirely capturing the magnetic beads. Thereby, this work shows the potential of the QMS advanced design in the intensification of the recovery of catalysts supports of magnetic character.

11.
PLoS One ; 16(9): e0257061, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34478473

RESUMO

A new method for hemoglobin (Hb) deoxygenation, in suspension or within red blood cells (RBCs) is described using the commercial enzyme product, EC-Oxyrase®. The enzymatic deoxygenation method has several advantages over established deoxygenation methodologies, such as avoiding side reactions that produce methemoglobin (metHb), thus eliminating the need for an inert deoxygenation gas and airtight vessel, and facilitates easy re-oxygenation of Hb/RBCs by washing with a buffer that contains dissolved oxygen (DO). The UV-visible spectra of deoxyHb and metHb purified from human RBCs using three different preparation methods (sodium dithionite [to produce deoxyHb], sodium nitrite [to produce metHb], and EC-Oxyrase® [to produce deoxyHb]) show the high purity of deoxyHb prepared using EC-Oxyrase® (with little to no metHb or hemichrome production from side reactions). The oxyHb deoxygenation time course of EC-Oxyrase® follows first order reaction kinetics. The paramagnetic characteristics of intracellular Hb in RBCs were compared using Cell Tracking Velocimetry (CTV) for healthy and sickle cell disease (SCD) donors and oxygen equilibrium curves show that the function of healthy RBCs is unchanged after EC-Oxyrase® treatment. The results confirm that this enzymatic approach to deoxygenation produces pure deoxyHb, can be re-oxygenated easily, prepared aerobically and has similar paramagnetic mobility to existing methods of producing deoxyHb and metHb.


Assuntos
Hemoglobinas/análise , Magnetismo , Oxiemoglobinas/análise , Anemia Falciforme , Feminino , Humanos , Masculino , Metemoglobina/análise , Oxigênio/análise , Doadores de Tecidos
12.
Exp Hematol ; 99: 21-31.e5, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-34015390

RESUMO

The presence of iron in circulating monocytes is well known as they play an essential role in iron recycling. It has been demonstrated that the iron content of blood cells can be measured through their magnetic behavior; however, the magnetic properties of different monocyte subtypes remain unknown. In this study we report, for the first time, the magnetic behavior of classical, intermediate and non-classical monocytes, which may be related to their iron storage capacity. The magnetic properties of monocytes were compared with those of other blood cells, such as lymphocytes and red blood cells in the oxyhemoglobin and methemoglobin states, and a cancer cell type. For this analysis, we used an instrument referred to as a Cell Tracking Velocimetry (CTV), which quantitatively characterizes the magnetic behavior of biological entities. Our results revealed that significant fractions of the intermediate and non-classical monocytes (up to 59% and 65% depending on the sample, respectively) have paramagnetic properties, suggesting their higher iron storage capacities. Moreover, our findings have implications for the immunomagnetic separation industry; we propose that negative magnetic isolation techniques for recovering monocytes from blood should be used with caution, as it is possible to lose magnetic monocytes when using this technique.


Assuntos
Eritrócitos/citologia , Citometria de Fluxo , Campos Magnéticos , Monócitos/citologia , Eritrócitos/metabolismo , Humanos , Monócitos/metabolismo
13.
Soft Matter ; 16(41): 9506-9518, 2020 Oct 28.
Artigo em Inglês | MEDLINE | ID: mdl-32966533

RESUMO

We present a numerical model that describes the microfluidic generation and manipulation of ferrofluid droplets under an external magnetic field. We developed a numerical Computational Fluid Dynamics (CFD) analysis for predicting and optimizing continuous flow generation and processing of ferrofluid droplets with and without the presence of a permanent magnet. More specifically, we explore the dynamics of oil-based ferrofluid droplets within an aqueous continuous phase under an external inhomogeneous magnetic field. The developed model determines the effect of the magnetic field on the droplet generation, which is carried out in a flow-focusing geometry, and its sorting in T-junction channels. Three-channel depths (25 µm, 30 µm, and 40 µm) were investigated to study droplet deformation under magnetic forces. Among the three, the 30 µm channel depth showed the most consistent droplet production for the studied range of flow rates. Ferrofluids with different loadings of magnetic nanoparticles were used to observe the behavior for different ratios of magnetic and hydrodynamic forces. Our results show that the effect of these factors on droplet size and generation rate can be tuned and optimized to produce consistent droplet generation and sorting. This approach involves fully coupled magnetic-fluid mechanics models and can predict critical details of the process including droplet size, shape, trajectory, dispensing rate, and the perturbation of the fluid co-flow for different flow rates. The model enables better understanding of the physical phenomena involved in continuous droplet processing and allows efficient parametric analysis and optimization.

14.
Sep Purif Technol ; 2482020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32655283

RESUMO

Superparamagnetic iron oxide nanoparticles (SPIONs) are employed in multiple applications, especially within medical and chemical engineering fields. However, their magnetic separation is very challenging as the magnetophoretic motion is hindered by thermal energy and viscous drag. Recent studies have addressed the recovery of SPIONs by a combination of cooperative magnetophoresis and sedimentation. Nevertheless, the effect of horizontal, high fields and gradients on the vertical sedimentation of SPIONs has not been described. In this work, we report, for the first time, the magnetically facilitated sedimentation of 5 nm particles by applying fields and gradients perpendicular to gravity. The magnetic field was generated by quadrupole magnetic sorters and the process was measured with time by tracking the concentration along the length of a channel contacting the 5 nm SPIONs within the quadrupole field. Our experimental data suggest that aggregates of 60-90 particles are formed in the system; thus, particle agglomeration by dipole-dipole interactions was promoted, and these clusters settled down as a result of gravitational forces. Multiple variables and parameters were evaluated, including the initial SPION concentration, the temperature, the magnetic field and gradient and operation time. It was found that the process was improved by decreasing the initial concentration and the temperature, but the magnitude of the magnetic field and gradient did not significantly affect the sedimentation. Finally, the separation process was rapid, with the systems reaching the equilibrium in approximately 20 minutes, which is a significant advantage in comparison to other systems that require longer times and larger particle sizes.

16.
Oncologist ; 25(8): e1158-e1169, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32452601

RESUMO

BACKGROUND: Poly(ADP-ribose) polymerase inhibitors (PARPis) are U.S. Food and Drug Administration (FDA) approved for treatment of BRCA-mutated metastatic breast cancer. Furthermore, the BROCADE studies demonstrated benefit of adding an oral PARPi, veliparib, to carboplatin and paclitaxel in patients with metastatic breast cancer harboring BRCA mutation. Given multiple possible dosing schedules and the potential benefit of this regimen for patients with defective DNA repair beyond BRCA, we sought to find the recommended phase II dose (RP2D) and schedule of veliparib in combination with carboplatin in patients with advanced breast cancer, either triple-negative (TNBC) or hormone receptor (HR)-positive, human epidermal growth receptor 2 (HER2) negative with defective Fanconi anemia (FA) DNA-repair pathway based on FA triple staining immunofluorescence assay. MATERIALS AND METHODS: Patients received escalating doses of veliparib on a 7-, 14-, or 21-day schedule with carboplatin every 3 weeks. Patients underwent [18]fluoro-3'-deoxythymidine (18 FLT) positron emission tomography (PET) imaging. RESULTS: Forty-four patients (39 TNBC, 5 HR positive/HER2 negative with a defective FA pathway) received a median of 5 cycles (range 1-36). Observed dose-limiting toxicities were grade (G) 4 thrombocytopenia (n = 4), G4 neutropenia (n = 1), and G3 akathisia (n = 1). Common grade 3-4 toxicities included thrombocytopenia, lymphopenia, neutropenia, anemia, and fatigue. Of the 43 patients evaluable for response, 18.6% achieved partial response and 48.8% had stable disease. Median progression-free survival was 18.3 weeks. RP2D of veliparib was established at 250 mg twice daily on days 1-21 along with carboplatin at area under the curve 5. Patients with partial response had a significant drop in maximum standard uptake value (SUVmax ) of target lesions between baseline and early in cycle 1 based on 18 FLT-PET (day 7-21; ptrend = .006). CONCLUSION: The combination of continuous dosing of veliparib and every-3-week carboplatin demonstrated activity and an acceptable toxicity profile. Decrease in SUVmax on 18 FLT-PET scan during the first cycle of this therapy can identify patients who are likely to have a response. IMPLICATIONS FOR PRACTICE: The BROCADE studies suggest that breast cancer patients with BRCA mutation benefit from addition of veliparib to carboplatin plus paclitaxel. This study demonstrates that a higher dose of veliparib is tolerable and active in combination with carboplatin alone. With growing interest in imaging-based early response assessment, the authors demonstrate that decrease in [18]fluoro-3'-deoxythymidine positron emission tomography (FLT-PET) SUVmax during cycle 1 of therapy is associated with response. Collectively, this study established a safety profile of veliparib and carboplatin in advanced breast cancer while also providing additional data on the potential for FLT-PET imaging modality in monitoring therapy response.


Assuntos
Neoplasias da Mama , Protocolos de Quimioterapia Combinada Antineoplásica/efeitos adversos , Benzimidazóis , Biomarcadores , Neoplasias da Mama/tratamento farmacológico , Carboplatina/uso terapêutico , Feminino , Humanos , Tomografia por Emissão de Pósitrons
17.
Sensors (Basel) ; 20(11)2020 May 27.
Artigo em Inglês | MEDLINE | ID: mdl-32471054

RESUMO

The use of functionalized magnetic particles for the detection or separation of multiple chemicals and biomolecules from biofluids continues to attract significant attention. After their incubation with the targeted substances, the beads can be magnetically recovered to perform analysis or diagnostic tests. Particle recovery with permanent magnets in continuous-flow microdevices has gathered great attention in the last decade due to the multiple advantages of microfluidics. As such, great efforts have been made to determine the magnetic and fluidic conditions for achieving complete particle capture; however, less attention has been paid to the effect of the channel geometry on the system performance, although it is key for designing systems that simultaneously provide high particle recovery and flow rates. Herein, we address the optimization of Y-Y-shaped microchannels, where magnetic beads are separated from blood and collected into a buffer stream by applying an external magnetic field. The influence of several geometrical features (namely cross section shape, thickness, length, and volume) on both bead recovery and system throughput is studied. For that purpose, we employ an experimentally validated Computational Fluid Dynamics (CFD) numerical model that considers the dominant forces acting on the beads during separation. Our results indicate that rectangular, long devices display the best performance as they deliver high particle recovery and high throughput. Thus, this methodology could be applied to the rational design of lab-on-a-chip devices for any magnetically driven purification, enrichment or isolation.


Assuntos
Sangue , Magnetismo , Imãs , Humanos , Dispositivos Lab-On-A-Chip , Microfluídica/instrumentação
18.
Anal Chem ; 92(2): 1956-1962, 2020 01 21.
Artigo em Inglês | MEDLINE | ID: mdl-31874030

RESUMO

The current clinical method for detecting anemia focuses on measuring the concentration of hemoglobin (Hb) in blood. However, recent developments in particle tracking algorithms and the understanding of the relationship between Hb and magnetism has enabled the quantitative measurement of the Hb content in a single red blood cell, RBC, based on magnetophoretic mobility. To further explore this relationship, 22 human blood samples obtained from 17 healthy volunteers were analyzed by the cell tracking velocimetry system, and the calculated Hb concentration from these measurements was compared to the values measured by UV-visible spectrophotometry, the standard method for measuring Hb in clinical laboratories. The results show close correlations between the mean of the spectrophotometric and magnetophoretic methods; however, single cell analysis with the magnetophoretic mobility method allows further elucidation of the distribution of Hb concentration within RBCs from a donor sample to be determined. Histograms of these magnetophoretic mobility distributions indicate that the fraction of RBCs that are below the bulk Hb concentration that defines anemia varies not only from donor to donor but also in the same donor over time. Consistent with a variable fraction below the anemic Hb concentration, the distribution around the mean has a large range. Previous studies have indicated that RBCs lose Hb during ex vivo storage; however, it is not known if this variability in the distribution of Hb content is a function of the age of the RBCs in a donor, suggesting a variable rate in RBC production between donors, or variability in available iron at the time of RBC formation. We suggest our cell tracking velocimetry system can reveal more information regarding this matter.


Assuntos
Rastreamento de Células/métodos , Hemoglobinas/análise , Reologia/métodos , Adulto , Anemia/diagnóstico , Eritrócitos/química , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Adulto Jovem
19.
J Mater Chem B ; 8(16): 3534-3541, 2020 04 29.
Artigo em Inglês | MEDLINE | ID: mdl-31868198

RESUMO

Fluorescent and magnetic materials play a significant role in biosensor technology, enabling sensitive quantification and separations with applications in diagnostics, purification, quality control, and therapeutics. Here, we present a magneto-fluorescent biosensor/separations platform consisting of quantum dots (QDs) and superparamagnetic iron oxide nanoparticles (SPIONs) that are separately encapsulated in amphiphilic block co-polymer micelles conjugated to DNA or protein (i.e., single-stranded (ss) DNA derived from the mRNA of the tumor suppressor protein p53 or avidin protein). Analytes were detected via an aggregation sandwich assay upon binding of at least 1 QD and 1 SPION-containing micelle to result in a fluorescent/magnetic composite. Multiplexed isolation of protein and DNA biomolecules was demonstrated by using QDs of varying emission wavelength; QD fluorescence intensity could be correlated with analyte concentration. Sequential or parallel biomolecule separation was achieved by adding appropriately functionalized SPION-containing micelles and applying user-controlled magnetic fields via patterned magnetic disks and wires. QD fluorescence was used to continuously visualize analyte separation during this process. This QD/SPION platform is simple to use, demonstrates ∼10-16 M sensitivity in analyte detection (comparable to competing QD biosensors based on energy transfer) with specificity against 1 and 2 basepair mismatches in DNA detection, molecular separations capability in solutions of ∼10-10 M, and permits simultaneous or parallel, multiplexed separation of protein and DNA. Thus, this versatile platform enables self-assembly-based rapid, sensitive, and specific detection and separation of biomolecules, simultaneously and with real-time visualization. This technology demonstrates potential for nanoscale assembly, biosensing, and bioseparations.


Assuntos
DNA de Neoplasias/análise , Compostos Férricos/química , Nanopartículas de Magnetita/química , Pontos Quânticos/química , Avidina/química , Técnicas Biossensoriais , Humanos , Imagem Óptica , Tamanho da Partícula , Propriedades de Superfície , Proteína Supressora de Tumor p53/química
20.
Cytometry A ; 95(5): 478-487, 2019 05.
Artigo em Inglês | MEDLINE | ID: mdl-30958642

RESUMO

The presence of iron in circulating monocytes is well known as they play essential roles in iron recycling. Also, the storage of this metal as well as its incorrect uptake and/or release are important data to diagnose different pathologies. It has been demonstrated that iron storage in human blood cells can be measured through their magnetic behavior with high accuracy; however, the magnetic characteristics of monocytes have not been reported so far to the best of our knowledge. Therefore, in this work, we report, for the first time, the physical and magnetic properties of human monocytes, along with plasma platelets, oxyhemoglobin red blood cells (oxyHb-RBCs), and methemoglobin red blood cells (metHb-RBCs). The different cell populations were separated by Ficoll-density gradient centrifugation, followed by a flow sorting step to isolate monocytes from peripheral blood mononuclear cells. The different fractions were analyzed by Coulter Counter (for determining the size distribution and concentration) and the sorted monocytes were qualitatively analyzed on ImageStream, a state-of-the-art imaging cytometer. The analysis of the Coulter Counter and ImageStream data suggests that although there exists contamination in the monocyte fraction, the integrity of the sorted monocytes appears to be intact and the concentration was high enough to precisely measure their magnetic velocity by Cell Tracking Velocimetry. Surprisingly, monocytes reported the highest magnetic mobility from the four fractions under analysis, with an average magnetic velocity 7.8 times higher than MetHb-RBCs, which is the only type of cells with positive magnetic velocities. This value is equivalent to a susceptibility 2.5 times higher than the value reported by fresh MetHb-RBCs. It should be noted that this is the first study that reports that a subpopulation of human monocytes is much more magnetic than MetHb-RBCs, opening the door to the possible isolation of human monocytes by label-free magnetic techniques. Further, it is suggested that these magnetic monocytes could "contaminate" positively selected, immunomagnetically labeled blood cells (i.e., during a process using magnetically conjugated antibodies targeting cells, such as CD34 positive cells). Conversely, these magnetic monocytes could be inadvertently removed from a desired blood population when one is using a negative magnetic isolation technique to target cells for removal. © 2019 International Society for Advancement of Cytometry.


Assuntos
Sangue/metabolismo , Fenômenos Magnéticos , Monócitos/citologia , Separação Celular , Tamanho Celular , Rastreamento de Células , Centrifugação com Gradiente de Concentração , Citometria de Fluxo , Humanos , Processamento de Imagem Assistida por Computador
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...