Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
Radiother Oncol ; 174: 101-108, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35839937

RESUMO

PURPOSE: This study aims to investigate the efficiency and the geometric as well as the dosimetric benefit of magnetic-resonance guided beam gating for stereotactic treatments in moving organs. METHOD: Patients treated with MR-guided (MRIdian system) SBRT for lung (n = 10) and liver (n = 10) targets were analyzed. Breath-hold gating was performed based on lesion tracking in sagittal cine MRI images. The target offset from the geometric center of the gating window with and without gating was evaluated. A dose reconstruction workflow based on convolution of these 2D position-probability maps and the daily 3D dose distribution was used to estimate the daily delivered dose including motion. The dose to the clinical target volume (CTV) and to a 2-cm ring structure around the planning target volume were evaluated. RESULTS: The applied gating protocol resulted in a mean (±standard deviation) gating efficiency of 55%±16%. Over all patients, the mean target offset (2D-root-mean-square error) was 8.3 ± 4.3 mm, which reduced to 2.4 ± 0.6 mm during gating. The dose reconstruction showed a mean deviation in CTV coverage (D95) from the static plans of -1.7%±1.8% with gating and -12.0%±8.4% if no gating would have been used. The mean dose (Dmean) in the ring structure, with respect to the static plans, showed mean deviations of -0.1%±0.3% with gating and -1.6%±1.8% without gating. CONCLUSION: The MRIdian system enables gating based on the inner anatomy and the implemented dose reconstruction workflow demonstrated geometric robust delivery of the planned radiation doses.


Assuntos
Radiocirurgia , Radioterapia de Intensidade Modulada , Humanos , Fígado/diagnóstico por imagem , Pulmão , Radiometria , Radiocirurgia/métodos , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos
2.
Radiother Oncol ; 166: 189-194, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34864135

RESUMO

BACKGROUND AND PURPOSE: A potential challenge in single-isocenter multi-lesion lung stereotactic body radiotherapy (SBRT) is that patient positioning is not based on each lesion individually, but on the average position of all lesions. This may lead to larger margins compared to treating with one isocenter per lesion, but increases workflow efficiency. The aim of this study was to investigate whether a single-isocenter technique leads to increased normal lung dose compared to a conventional multiple-isocenters technique. MATERIALS AND METHODS: A cohort of 15 NSCLC patients with two or three lesions previously treated with SBRT was subjected to treatment planning with a multiple-isocenter technique and a single-isocenter technique. For the latter, two margin approaches were evaluated: (1) identical margins for each internal target volume (ITV), assuming an average registration for all lesions in cone-beam CT (CBCT) positioning verification and (2) a smaller margin for the largest lesion, assuming an optimal registration for that lesion. For all 45 treatment plans, mean lung dose (MLD) and lungs-V20Gy were evaluated. The study was performed following RATING guidelines. RESULTS: The MLD was 4.9 ± 1.9 Gy (mean ± SD) for multiple-isocenters and 5.4 ± 2.1 Gy and 5.3 ± 2.2 Gy for single-isocenter approach 1 and 2, respectively. V20Gy was 5.5 ± 3.7%, 5.5 ± 3.2% and 5.4 ± 3.3%. A median [range] increase in MLD of 11.6% [-14.9 - 26.8] was observed when comparing single-isocenter treatment plans to those with multiple isocenters. V20Gy increased by 0.2 [-3.4 - 1.3] percentage points. CONCLUSION: A single-isocenter SBRT technique for lung patients with multiple targets results in clinically acceptable increases in normal lung dose.


Assuntos
Neoplasias Pulmonares , Radiocirurgia , Radioterapia de Intensidade Modulada , Humanos , Pulmão/diagnóstico por imagem , Pulmão/patologia , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/patologia , Neoplasias Pulmonares/radioterapia , Radiocirurgia/métodos , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos
3.
Cancers (Basel) ; 13(21)2021 Oct 28.
Artigo em Inglês | MEDLINE | ID: mdl-34771567

RESUMO

The aim of this study was to quantify anatomical changes of parotids and submandibular glands and evaluate potential dosimetric advantages during weekly adaptive MR-guided radiotherapy (MRgRT) for the definitive treatment of head and neck cancer (HNC). The data and plans of 12 patients treated with bilateral intensity-modulated radiotherapy for HNC using MR-linac, with weekly offline adaptations, were prospectively evaluated. The positional and volumetric changes of the salivary glands were analyzed by manual segmentation in weekly MRI images and the dosimetric impact of these anatomical changes on the adapted treatment plans was assessed. The mean volume change in parotid and submandibular gland volume was -31.9% (p < 0.0001) and -29.7% (p < 0.0001) after five weeks, respectively. The volume change was significantly correlated with the cumulative dose for the respective gland at the time of volume measurement. Inter-parotid distance changed by -5.4% (6.5 mm) on average after five weeks (p = 0.0005). The distance became significantly smaller only in the left-right direction. The inter-submandibular gland distance changed by 0.7 mm (p = 0.38). This study demonstrated significant changes in salivary gland volumes and position following daily MR guidance and weekly plan adaptation. Ongoing clinical trials will provide data on the clinical impact of these changes and novel MR-based adaptation strategies.

4.
Radiat Oncol ; 16(1): 217, 2021 Nov 14.
Artigo em Inglês | MEDLINE | ID: mdl-34775998

RESUMO

BACKGROUND: Main purpose was to describe procedures and identify challenges in the implementation process of adaptive and non-adaptive MR-guided radiotherapy (MRgRT), especially new risks in workflow due to the new technique. We herein report the single center experience for the implementation of (MRgRT) and present an overview on our treatment practice. METHODS: Descriptive statistics were used to summarize clinical and technical characteristics of treatment and patient characteristics including sites treated between April 2019 and end of March 2020 after ethical approval. A risk analysis was performed to identify risks of the online adaptive workflow. RESULTS: A summary of the processes on the MR-Linac including workflows, quality assurance and possible pitfalls is presented. 111 patients with 124 courses were treated during the first year of MR-guided radiotherapy. The most commonly treated site was the abdomen (42% of all treatment courses). 73% of the courses were daily online adapted and a high number of treatment courses (75%) were treated with stereotactic body irradiation. Only 4/382 fractions could not be treated due to a failing online adaptive quality assurance. In the risk analysis for errors, the two risks with the highest risk priority number were both in the contouring category, making it the most critical step in the workflow. CONCLUSION: Although challenging, establishment of MRgRT as a routinely used technique at our department was successful for all sites and daily o-ART was feasible from the first day on. However, ongoing research and reports will have to inform us on the optimal indications for MRgRT because careful patient selection is necessary as it continues to be a time-consuming treatment technique with restricted availability. After risk analysis, the most critical workflow category was the contouring process, which resembles the need of experienced staff and safety check paths.


Assuntos
Implementação de Plano de Saúde , Neoplasias/patologia , Seleção de Pacientes , Garantia da Qualidade dos Cuidados de Saúde/normas , Radiocirurgia/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia Guiada por Imagem/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Terapia Combinada , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Neoplasias/radioterapia , Neoplasias/cirurgia , Órgãos em Risco/efeitos da radiação , Prognóstico , Dosagem Radioterapêutica , Radioterapia de Intensidade Modulada/métodos , Reirradiação , Estudos Retrospectivos , Gestão de Riscos
5.
Phys Imaging Radiat Oncol ; 17: 43-46, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33898777

RESUMO

The optimal approach for magnetic resonance imaging-guided online adaptive radiotherapy is currently unknown and needs to consider patient on-couch time constraints. The aim of this study was to compare two different plan optimization approaches. The comparison was performed in 238 clinically applied online-adapted treatment plans from 55 patients, in which the approach of re-optimization was selected based on the physician's choice. For 33 patients where both optimization approaches were used at least once, the median treatment planning dose metrics of both target and organ at risk differed less than 1%. Therefore, we concluded that beam segment weight optimization was chosen adequately for most patients without compromising plan quality.

6.
Strahlenther Onkol ; 197(12): 1093-1103, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33891126

RESUMO

PURPOSE: Purpose of this study is to evaluate plan quality on the MRIdian (Viewray Inc., Oakwood Village, OH, USA) system for head and neck cancer (HNC) through comparison of planning approaches of several centers. METHODS: A total of 14 planners using the MRIdian planning system participated in this treatment challenge, centrally organized by ViewRay, for one contoured case of oropharyngeal carcinoma with standard constraints for organs at risk (OAR). Homogeneity, conformity, sparing of OARs, and other parameters were evaluated according to The International Commission on Radiation Units and Measurements (ICRU) recommendations anonymously, and then compared between centers. Differences amongst centers were assessed by means of Wilcoxon test. Each plan had to fulfil hard constraints based on dose-volume histogram (DVH) parameters and delivery time. A plan quality metric (PQM) was evaluated. The PQM was defined as the sum of 16 submetrics characterizing different DVH goals. RESULTS: For most dose parameters the median score of all centers was higher than the threshold that results in an ideal score. Six participants achieved the maximum number of points for the OAR dose parameters, and none had an unacceptable performance on any of the metrics. Each planner was able to achieve all the requirements except for one which exceeded delivery time. The number of segments correlated to improved PQM and inversely correlated to brainstem D0.1cc and to Planning Target Volume1 (PTV) D0.1cc. Total planning experience inversely correlated to spinal canal dose. CONCLUSION: Magnetic Resonance Image (MRI) linac-based planning for HNC is already feasible with good quality. Generally, an increased number of segments and increasing planning experience are able to provide better results regarding planning quality without significantly prolonging overall treatment time.


Assuntos
Radioterapia de Intensidade Modulada , Humanos , Órgãos em Risco , Aceleradores de Partículas , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos
7.
Radiat Oncol ; 15(1): 203, 2020 Aug 21.
Artigo em Inglês | MEDLINE | ID: mdl-32825848

RESUMO

BACKGROUND: Online adaptive radiotherapy is intended to prevent plan degradation caused by inter-fractional tumor volume and shape changes, but time limitations make online re-planning challenging. The aim of this study was to compare the quality of online-adapted plans to their respective reference treatment plans. METHODS: Fifty-two patients treated on a ViewRay MRIdian Linac were included in this retrospective study. In total 238 online-adapted plans were analyzed, which were optimized with either changing of the segment weights (n = 85) or full re-optimization (n = 153). Five different treatment sites were evaluated: prostate, abdomen, liver, lung and pelvis. Dosimetric parameters of gross tumor volume (GTV), planning target volume (PTV), 2 cm ring around the PTV and organs at risk (OARs) were considered. The Wilcoxon signed-rank test was used to assess differences between online-adapted and reference treatment plans, p < 0.05 was considered significant. RESULTS: The average duration of the online adaptation, consisting of contour editing, plan optimization and quality assurance (QA), was 24 ± 6 min. The GTV was slightly larger (average ± SD: 1.9% ± 9.0%) in the adapted plans than in the reference plans (p < 0.001). GTV-D95% exhibited no significant changes when considering all plans, but GTV-D2% increased by 0.40% ± 1.5% on average (p < 0.001). There was a very small yet significant decrease in GTV-coverage for the abdomen plans. The ring Dmean increased on average by 1.0% ± 3.6% considering all plans (p < 0.001). There was a significant reduction of the dose to the rectum of 4.7% ± 16% on average (p < 0.001) for prostate plans. CONCLUSIONS: Dosimetric quality of online-adapted plans was comparable to reference treatment plans and OAR dose was either comparable or decreased, depending on treatment site. However, dose spillage was slightly increased.


Assuntos
Neoplasias/radioterapia , Sistemas On-Line/normas , Órgãos em Risco/efeitos da radiação , Garantia da Qualidade dos Cuidados de Saúde , Planejamento da Radioterapia Assistida por Computador/normas , Radioterapia Guiada por Imagem/normas , Radioterapia de Intensidade Modulada/normas , Humanos , Imageamento por Ressonância Magnética/métodos , Prognóstico , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Estudos Retrospectivos
8.
Radiother Oncol ; 152: 203-207, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32067819

RESUMO

PURPOSE: To report the feasibility of magnetic resonance imaging-guided cardiac single fraction radioablation (MRgRA) in a patient with dilated cardiomyopathy and recurrent sustained ventricular tachycardia (VT) leading to electrical storms (ES). MATERIALS/METHODS: A workflow to perform Stereotactic Arrhythmia Radioablation (STAR) on a hybrid MR-Linac with real-time tracking and beam-gating was established. Challenges of the MRgRA approach included: (a) the safety of a non-MR compatible cardiac implantable electronic device (CIED) in the MR-Linac field, (b) artefacts caused by the CIED and (c) respiratory motion management with cine-tracking of the moving heart. The specific absorption rate and slew rate of the MR-Linac were within the specifications of a MR-conditional CIED. Phantom measurements showed CIED distortion artefacts of less than 1.5 mm. During MR simulation, tracking could be established on the upper liver to avoid interference with the moving heart and CIED extinction artefacts. Areas of anatomical scarring and critical substrate were identified using invasive three-dimensional electroanatomical mapping of the clinical VT during electrophysiological studies and cardiac MR imaging/computed tomography to build a volumetric target. RESULTS: A 71-year-old male patient with non-ischemic dilated cardiomyopathy and recurrent therapy-refractory sustained VT with repetitive implantable cardioverter-defibrillator (ICD) shocks was treated with a single fraction of 25 Gy @85% isodose, cine-tracking time was 46 min, beam-on time 24 min. 24 h post intervention the patient developed an aggravation of the clinical VT and prolonged ES. VT ceased following high-dose dexamethasone administration after 48 h. After this point, the patient remained without any episodes of sustained ventricular tachyarrhythmia requiring ICD interventions until the last follow-up at three months. CONCLUSION: Real-time tracking and beam-gating were successfully applied in this first MRgRA to treat sustained VT.


Assuntos
Desfibriladores Implantáveis , Taquicardia Ventricular , Idoso , Arritmias Cardíacas , Seguimentos , Coração , Humanos , Imageamento por Ressonância Magnética , Masculino
9.
Phys Imaging Radiat Oncol ; 16: 109-112, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-33458353

RESUMO

The introduction of real-time imaging by magnetic resonance guided linear accelerators (MR-Linacs) enabled adaptive treatments and gating on the tumor position. Different end-to-end tests monitored the accuracy of our MR-Linac during the first year of clinical operation. We report on the stability of these tests covering a static, adaptive and gating workflow. Film measurements showed gamma passing rates of 96.4% ± 3.4% for the static tests (five measurements) and for the two adaptive tests 98.9% and 99.99%, respectively (criterion 2%/2mm). The gated point dose measurements in the breathing phantom were 2.7% lower than in the static phantom.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...