Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Appl Ergon ; 36(3): 283-92, 2005 May.
Artigo em Inglês | MEDLINE | ID: mdl-15854571

RESUMO

In this paper a mechanical flexibility test is developed which can be used to assess multi layer body armour systems. This is compared with a subjective manual test, and then with the results of wearer trials conducted using the recently approved ISO body armour standard ISO 14876-1 (2002). A series of trials was conducted on six different ballistic and/or stab resistant body armour types with a variety of protection levels and constructions. These were tested using the mechanical test system in which the armour was forced through a 200 mm hole by a 100 mm hemispherical plunger. The results of this test were then compared to a second set of trials in which flexibility of the same armour was assessed by manual handling and flexing of the armour. Finally an ergonomic wearer trial was conducted with four armours according to ISO 14876-1 (2002) each armour being assessed by four volunteers and the results compared to flexibility data collected in the first two trials. It was shown that the mechanical flexibility test produced results which were in good agreement with a purely subjective flexibility assessment. These results in turn showed reasonable but not exact correlation with the wearer trials. The ISO wearer trials addressed other factors such as overall comfort and fit of the systems and so the results were not purely a function of flexibility.


Assuntos
Ergonomia/normas , Maleabilidade , Roupa de Proteção/normas , Ergonomia/métodos , Experimentação Humana , Humanos , Masculino , Controle de Qualidade , Reino Unido
2.
J Clin Forensic Med ; 10(4): 243-8, 2003 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-15275000

RESUMO

BACKGROUND: Stab attacks generate high loads, and to defeat them, armour needs to be of a certain thickness and stiffness. Slash attacks produce much lower loads and armour designed to defeat them can be far lighter and more flexible. METHODS AND SUBJECTS: Phase 1: Human performance in slash attacks: 87 randomly selected students at the Royal Military College of Science were asked to make one slash attack with an instrumented blade on a vertically mounted target. No instructions on how to slash the target were given. The direction, contact forces and velocity of each attack were recorded. Phase 2: Clinical experience with edged weapon attacks: The location and severity of all penetrating injuries in patients attending the Glasgow Royal Infirmary between 1993 and 1996 were charted on anatomical figures. RESULTS: Phase 1: Two types of human slash behaviour were evident: a 'chop and drag' blow and a 'sweep motion' type of attack. 'Chop and drag' attacks had higher peak forces and velocities than sweep attacks. Shoulder to waist blows (diagonal) accounted for 82% of attacks, 71% of attackers used a long diagonal slash with an average cut length of 34 cm and 11% used short diagonal attacks with an average cut length of 25 cm. Only 18% of attackers slashed across the body (short horizontal); the average measured cut length of this type was 28 cm. The maximum peak force for the total sample population was 212 N; the maximum velocity was 14.88 m s(-1). The 95 percentile force for the total sample population was 181 N and the velocity was 9.89 m s(-1). Phase 2: 431 of the 500 patients had been wounded with edged weapons. The average number of wounds sustained by victims in knife assaults was 2.4. The distribution of wounds by frequency and severity are presented. CONCLUSIONS: Anti-slash protection is required for the arms, neck, shoulders, and thighs. The clinical experience of knife-attack victims provides information on the relative vulnerabilities of different regions of the body. It is anticipated that designing a tunic-type of Police uniform that is inherently stab and slash resistant will eventually replace the current obvious and often bulky extra protective vest. Attempts at making a combined garment will need to be guided by ergonomic considerations and field testing. A similar anatomical regional risk model might also be appropriate in the design of anti-ballistic armour and combined anti-ballistic and knife-resistant armour.

3.
Forensic Sci Int ; 102(2-3): 79-89, 1999 Jun 28.
Artigo em Inglês | MEDLINE | ID: mdl-10464927

RESUMO

Stab-resistant body armour is now becoming a standard item of equipment for police officers in the United Kingdom. In the UK these are usually required to have a stab resistance as specified by the Police Scientific Development Branch KR42 standard [G. Parker, PSDB Stab Resistant Body Armour Test Procedure, Police Scientific Development Branch, Publication No 10/93, 1993]. There are several other test standards, all of which specify that body armour must resist penetration by a specific blade type delivered at a specific energy level or range of levels. However, the actual range of energy levels specified varies over almost an order of magnitude and the basis for these levels is not clearly defined. This paper describes tests to determine the energy range and characteristics of stabbing actions that might be directed against stab resistant body armour by an assailant. The energy and velocity that can be achieved in stabbing actions has been determined for a number of sample populations. Volunteers were asked to stab a target using an instrumented knife that measured the axial force and acceleration during the stabbing. The maximum energy obtained in underarm stabbing actions was 64 J whilst overarm stabbing actions could produce 115 J. The loads produced on contact with the target often approached 1000 N.


Assuntos
Agressão/fisiologia , Braço/fisiologia , Teste de Materiais/instrumentação , Roupa de Proteção/normas , Desempenho Psicomotor , Ferimentos Perfurantes/etiologia , Ferimentos Perfurantes/prevenção & controle , Aceleração , Fenômenos Biomecânicos , Metabolismo Energético , Feminino , Humanos , Masculino , Polícia , Fatores de Risco , Caracteres Sexuais , Fatores de Tempo , Reino Unido
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...