Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Life (Basel) ; 12(2)2022 Jan 28.
Artigo em Inglês | MEDLINE | ID: mdl-35207484

RESUMO

BACKGROUND: This study aimed to identify the better arc configuration of volumetric modulated arc therapy (VMAT) for high-grade glioma and glioblastoma, focusing on a dose reduction to the hypothalamic-pituitary axis through an analysis of dose-volumetric parameters, as well as a correlation analysis between the planned target volume (PTV) to organs at risk (OAR) distance and the radiation dose. METHOD: Twenty-four patients with 9 high-grade glioma and 15 glioblastomas were included in this study. Identical CT, MRI and structure sets of each patient were used for coplanar VMAT (CO-VMAT), dual planar VMAT (DP-VMAT) and multi-planar VMAT (MP-VMAT) planning. The dose constraints adhered to the RTOG0825 and RTOG9006 protocols. The dose-volumetric parameters of each plan were collected for statistical analysis. Correlation analyses were performed between radiation dose and PTV-OARs distance. RESULTS: The DP-VMAT and MP-VMAT achieved a significant dose reduction to most nearby OARs when compared to CO-VMAT, without compromising the dose to PTV, plan homogeneity and conformity. For centrally located OARs, including the hypothalamus, pituitary, brain stem and optic chiasm, the dose reductions ranged from 2.65 Gy to 3.91 Gy (p < 0.001) in DP-VMAT and from 2.57 Gy to 4 Gy (p < 0.001) in MP-VMAT. Similar dose reduction effects were achieved for contralaterally located OARs, including the hippocampus, optic nerve, lens and retina, ranging from 1.06 Gy to 4.37 Gy in DP-VMAT and from 0.54 Gy to 3.39 Gy in MP-VMAT. For ipsilaterally located OARs, DP-VMAT achieved a significant dose reduction of 1.75 Gy to Dmax for the optic nerve. In the correlation analysis, DP-VMAT and MP-VMAT showed significant dose reductions to centrally located OARs when the PTV-OAR distance was less than 4 cm. In particular, DP-VMAT offered better sparing to the optic chiasm when it was located less than 2 cm from the PTV than that of MP-VMAT and CO-VMAT. DP-VMAT and MP-VMAT also showed better sparing to the contralateral hippocampus and retina when they were located 3-8 cm from the PTV. CONCLUSION: The proposed DP-VMAT and MP-VMAT demonstrated significant dose reductions to centrally located and contralateral OARs and maintained the high plan qualities to PTV with good homogeneity and conformity when compared to CO-VMAT for high-grade glioma and glioblastoma. The benefit in choosing DP-VMAT and MP-VMAT over CO-VMAT was substantial when the PTV was located near the hypothalamus, pituitary, optic chiasm, contralateral hippocampus and contralateral retina.

2.
Life (Basel) ; 11(10)2021 Oct 14.
Artigo em Inglês | MEDLINE | ID: mdl-34685456

RESUMO

OBJECTIVES: This study aimed to find the optimal radiotherapy VMAT plans, that achieved high conformity and homogeneity to the planned target volume (PTV), and minimize the dose to nearby organs at risk including the non-PTV lung, heart and oesophagus for patients with centrally located non-small Cell Lung Cancer. METHODS: A total of 18 patients who were treated for stage III centrally located non-small Cell Lung Cancer were selected retrospectively for this study. Identical CT datasets, 4D CT and structure dataset were used for radiotherapy planning based on single-planar VMAT (SP-VMAT), dual-planar VMAT (DP-VMAT) and Hybrid VMAT (H-VMAT). For SP-VMAT, one full arc and two half arcs were created on single-plane with couch at 0°. For DP-VMAT, one full arc was created with couch at 0°, and two half arcs with couch rotation of 330° or 30°. For H-VMAT, anterior-posterior opposing fixed beam and two half arcs were planned at couch at 0°. Dose constraints were adhered to the RTOG0617. Dose volumetric parameters were collected for statistical analysis. RESULTS: There were no significant differences for the PTV, HI, CI between the SP-VMAT, DP-VMAT and H-VMAT. For the non-PTV lungs, Dmean, V20, V10, V5, D1500 and D1000 were significantly lower (2.05 Gy, 6.47%, 15.89%, 11.66% 4.17 Gy and 5.47 Gy respectively) in H-VMAT than that of SP-VMAT (all p < 0.001). For the oesophagus, Dmax, Dmean, V30 and V18.8 of H-VMAT were 0.08 Gy, 1.73 Gy, 5.54% and 7.17% lower than that of the SP-VMAT plan. For the heart, Dmean, V34, V28, V20 and V10 of DP-VMAT were lower than that of SP-VMAT by 1.45 Gy, 0.65%, 1.74%, 4.8% and 7.11% respectively. CONCLUSION: The proposed H-VMAT showed more favourable plan quality than the SP-VMAT for centrally located stage III NSCLC, in particular for non-PTV lungs and the oesophagus. It will benefit patients, especially those who planned for immunotherapy (Durvalumab) after standard chemo-irradiation. The proposed DP-VMAT plan showed significant dose reduction to the heart when compared to the H-VMAT plan.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...