Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 66
Filtrar
1.
Int J Dermatol ; 63(6): 704-713, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38643368

RESUMO

Acne, a highly prevalent skin disease, can be particularly bothersome for patients of Asian background because of its impact on self-confidence and social interactions. In addition to active acne lesions, some patients may develop sequelae such as scarring, macular/postinflammatory hyperpigmentation, or erythema. The tendency of Asian skin to develop sequelae because of its increased susceptibility to irritation, cultural preferences for lighter skin phototypes, and differences in skincare regimens may all contribute to the increased burden of acne. Moreover, many Asia-Pacific countries do not have their own guidelines for acne management, and those that do often have no schedule in place for regular updates. In this article, we provide a critical review of the published guidance for the management of acne and its sequelae in the Asia-Pacific region, identifying gaps in current recommendations that could be addressed to enhance standards of acne care in Asia-Pacific countries. Along with highlighting the importance of a comprehensive skincare regimen to increase treatment efficacy and adherence, we discuss topical retinoids and retinoid combination options in the acne armamentarium that may be beneficial for sequelae prevention and management, such as adapalene 0.3% ± benzoyl peroxide 2.5%, tretinoin 0.05%, tazarotene 0.1%, and trifarotene 0.005%. In particular, trifarotene 0.005% has been observed to significantly reduce acne scar counts in a Phase 4 study. The recent data highlight the need to establish up-to-date guidance for acne and acne sequelae management in Asia-Pacific countries to provide optimal care to Asian patients.


Assuntos
Acne Vulgar , Fármacos Dermatológicos , Retinoides , Humanos , Acne Vulgar/tratamento farmacológico , Acne Vulgar/complicações , Fármacos Dermatológicos/administração & dosagem , Fármacos Dermatológicos/uso terapêutico , Fármacos Dermatológicos/efeitos adversos , Retinoides/administração & dosagem , Retinoides/uso terapêutico , Retinoides/efeitos adversos , Ásia , Hiperpigmentação/etiologia , Hiperpigmentação/tratamento farmacológico , Administração Cutânea , Cicatriz/etiologia , Cicatriz/tratamento farmacológico , Guias de Prática Clínica como Assunto , Higiene da Pele/métodos , Eritema/tratamento farmacológico , Eritema/etiologia
2.
Lasers Surg Med ; 56(2): 142-149, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38247054

RESUMO

BACKGROUND AND OBJECTIVES: Fractional radiofrequency devices have been demonstrated to improve skin texture, such as smoothness, rhytides, brightness, and atrophic acne scars, by increasing dermal thickness, dermal collagen content, and dermal fibrillin content. The objective of the study is to assess the efficacy and adverse effects of this device on Asian patients of skin type III and IV with skin textural changes. MATERIALS AND METHODS: The study was designed as a prospective, open-labeled single-arm study, which was conducted with 20 Chinese patients aged 21-60 years and having irregularities in their skin texture, rhytides, and acne scars. The patients received six treatments at intervals of 4 weeks. Treatment was initiated with the maximum energy tolerated, which was then adjusted during the course of treatment if the patients felt excessive discomfort. A total of two passes were delivered in each session. Physician assessment results and standardized photographs were collected at the baseline, after all treatment visits, and at 1, 2, and 6 months after the final treatment visit. RESULTS: A total of 17 patients completed the study according to the established protocol. At the 6-month follow-up, 71% of patients were satisfied and 24% of patients were very satisfied with the received treatments, and the treatment physician reported varying degrees of improvement based on the global assessment scale in 60% of the subjects. While the anticipated side effects, such as erythema, edema, pinpoint bleeding, scab formation, and flare of acne, were noted in the patients, no serious adverse effects occurred. CONCLUSION: The use of fractional radiofrequency improves skin texture and is safe for use in Asian patients of skin type III and IV. No long-term serious adverse effects were noted.


Assuntos
Acne Vulgar , Cicatriz , Humanos , Acne Vulgar/radioterapia , Povo Asiático , Cicatriz/terapia , Estudos Prospectivos , Pele/patologia , Resultado do Tratamento , Adulto Jovem , Adulto , Pessoa de Meia-Idade
3.
J Clin Med ; 12(9)2023 Apr 29.
Artigo em Inglês | MEDLINE | ID: mdl-37176650

RESUMO

Myopia control efficacy and long-term safety of the Breath-O-Correct orthokeratology (OK) lens was evaluated in a 2-year randomized, single vision (SV) spectacle lens-controlled, single-blind clinical trial combining clinical and tear proteomics data. A total of 71 children (43 OK, 9.8 ± 1.3 years; 28 SV, 9.5 ± 1.4 years) completed the 2-year study. Axial length (AL), cycloplegic refraction, clinical safety parameters (best-corrected visual acuity, central cornea thickness, corneal endothelial health, ocular surface disease index), and quantitative tear proteomics were evaluated by masked examiners. Mean 2-year-normalized AL elongations in the OK and SV groups differed significantly (p = 0.03) and were 0.37 ± 0.37 mm and 0.60 ± 0.41 mm, respectively. OK-mediated myopia control efficacy was 37.1%. No significant difference was found in clinical safety parameters of both groups (p > 0.10), except for a thinner central corneal thickness in the OK group (p = 0.01). Proteomics revealed modest OK lens-mediated effects on immune response proteins, including an increased abundance of haptoglobin at 6 and 12 months and a decreased abundance of two proteins (neutrophil defensin 3 and histone 4) at 6 months. The changes were further validated using a high-resolution multiple-reaction monitoring (MRMHR) mass spectrometry. In summary, the Breath-O-Correct OK lens significantly reduced AL elongation in schoolchildren without adverse clinical effects or subclinical inflammatory responses.

4.
Sci Rep ; 12(1): 11588, 2022 07 08.
Artigo em Inglês | MEDLINE | ID: mdl-35804049

RESUMO

This study aimed to evaluate the efficacy of 18-month 0.01% atropine in 61 myopic children (aged 7-10) and the relationship with central retinal response (by multifocal electroretinogram [mfERG]) in a double-masked randomized placebo-controlled clinical trial. Global-flash mfERG was measured at baseline, while cycloplegic spherical equivalent refraction (SER) and axial length (AL) were measured at baseline and at 6-month intervals. Annualized change in SER and AL were compared between atropine and control groups, and the relationships with baseline mfERG were evaluated. Changes in SER (-0.70 ± 0.39D vs. -0.66 ± 0.41D, p = 0.63) and AL (0.32 ± 0.16 mm vs. 0.30 ± 0.22 mm, p = 0.52) were similar in atropine and control groups. Interestingly, in the placebo group, mfERG amplitude was negatively correlated with axial elongation (Rp = -0.44, p = 0.03) as in our previous study. However, in the atropine group, an opposite trend was observed that axial elongation was positively correlated with mfERG amplitude (Ra = 0.37, p = 0.04). Annualized myopia progression demonstrated similar opposite effect between atropine and placebo groups but did not reach statistical significance. An ERG screening protocol may be warranted to identify suitable candidates to reduce the likelihood of an unfavorable treatment response by 0.01% atropine.


Assuntos
Atropina , Miopia , Comprimento Axial do Olho , Criança , Progressão da Doença , Humanos , Miopia/tratamento farmacológico , Soluções Oftálmicas , Refração Ocular , Testes Visuais
5.
Int J Dermatol ; 61(2): 184-190, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34553372

RESUMO

BACKGROUND: HLA-B*15:11 is associated with carbamazepine (CBZ)-induced severe cutaneous adverse drug reactions (SCARs) in Japanese and some Asian populations, but such data remains relatively limited in Chinese. Routine HLA-B*15:02 screening is mandatory before CBZ commencement, however, SCARs related to CBZ were still observed in non-HLA*B-15:02 carriers. OBJECTIVE: We aimed to find out the prevalence of HLA-B*15:11 in Chinese patients and its associations with CBZ-induced SCARs. METHOD: We screened 8,328 blood samples collected for HLA allele typing before CBZ commencement during the period of January 2014 to December 2019. In HLA-B*15:02 negative Chinese patients, HLA-B*15:11 status were further screened, and the incidence of SCARs in the CBZ group was compared with the control group without CBZ use. RESULT: In this cohort, 1416 out of 8328 patients (17%) tested HLA-B*15:02 positive and were advised to avoid CBZ, while 80 (0.96%) were found to be HLA-B*15:11 positive. In 6911 (83%) patients who tested HLA-B*15:02 negative, 70 (1.01%) were HLA-B*15:11 positive. Five out of 70 (7.14%) patients had SCARs. The incidence of SCARs in HLA-B*15:11 carriers who received CBZ was significantly higher than those without CBZ (17.4% [4/23] vs. 2.13% [1/47], P = 0.037*). The odds ratio was 9.68 (95% CI 1.02-92.4, P = 0.048*). These included: one Stevens-Johnson syndrome (SJS), two DRESS, and one MPE after CBZ use, while one developed MPE after phenytoin use in control. CONCLUSION: HLA-B*15:11 is a potential risk factor of CBZ-induced SCARs in HLA-B*15:02 negative Chinese patients. Further screening of HLA-B*15:11 status in those HLA-B*15:02 negative patients is recommended to avoid undesirable SCARs.


Assuntos
Anticonvulsivantes , Síndrome de Stevens-Johnson , Carbamazepina , China , Predisposição Genética para Doença , Antígenos HLA-B/genética , Antígeno HLA-B15/genética , Humanos
6.
Transl Vis Sci Technol ; 10(11): 18, 2021 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-34559185

RESUMO

Purpose: This study evaluated the efficacy and ocular surface status of Breath-O Correct, novel orthokeratology (OK) lenses, worn overnight for 3 months. Lens-induced changes in the tear proteome were evaluated. Methods: Thirty-one subjects, aged 19 to 26 years with refractive error from -1.00 to -5.00 D, were randomly assigned 1:1 to the treatment or control group. Refraction, visual acuity, corneal integrity, biomechanics and endothelial health, ocular surface changes, and subjective symptoms were assessed at the baseline, one-month, and three-month visits. The tear proteome was characterized over time using sequential window acquisition of all theoretical ion spectra mass spectrometry. Results: Lenses improved uncorrected visual acuity and reduced spherical powers with similar efficacy to other OK lenses. Significant reductions (P < 0.05) in corneal hysteresis (11.12 ± 1.12 to 10.38 ± 1.36 mm Hg) and corneal resistance factor (11.06 ± 1.32 to 9.90 ± 1.45 mm Hg) were observed in the treatment group after one month of lens wear, whereas other assessed factors remained unchanged. Thirteen and eight differentially expressed proteins were found after one month and three months of lens wear, respectively. Two proteins (proline-rich protein 27 and immunoglobulin V regions) were differentially expressed at both visits. Conclusions: Over a three-month period, Breath-O Correct lenses were overall safe, well tolerated, efficacious in refractive power reduction, and comparable with other OK lenses. Furthermore, their use caused only minor noninflammatory protein expression changes in the tear proteome. Translational Relevance: This study investigated the safety of orthokeratology contact lenses on the ocular surface in molecular aspects and standard clinical parameters.


Assuntos
Miopia , Proteômica , Adulto , Biomarcadores , Topografia da Córnea , Humanos , Miopia/terapia , Refração Ocular , Adulto Jovem
7.
Curr Alzheimer Res ; 18(3): 185-195, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34102976

RESUMO

OBJECTIVE: This study investigated the relationship between neural activities and retinal structures associated with working memory (WM) in older adults with mild cognitive impairment (MCI). METHODS: Eleven older adults with MCI and 29 healthy controls (60 to 73 years old) were tested. All participants underwent an event-related potential (ERP) recording while performing the two-back memory task. The Optical coherence tomography angiography (OCT-A) was administered to examine the perfusion and vessel density in the retina. RESULTS: Results showed that WM performance in the MCI group was negatively associated with ERP latencies in central parietal regions (CP6 and CP8) (ps< 0.05). The left nasal vessel and perfusion densities were negatively correlated with the latencies in these two central parietal regions and positively related to WM performance only in the MCI group (ps< 0.05). CONCLUSION: The findings on WM, central parietal brain activity, and left nasal vessel and perfusion densities in the retina help us gain a better understanding of the neural and retinal underpinnings of WM in relation to MCI.


Assuntos
Potenciais Evocados , Memória de Curto Prazo/fisiologia , Testes Neuropsicológicos , Retina , Idoso , Cognição/fisiologia , Disfunção Cognitiva/psicologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Neurônios , Tomografia de Coerência Óptica
8.
Lasers Surg Med ; 53(8): 1032-1042, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-33544930

RESUMO

BACKGROUND AND OBJECTIVES: Facial melasma is a disfiguring pigmentation and occurs frequently with aging skin. Topical treatment alone was often suboptimal. A recent study showed that fractional picosecond laser has promising result in benign pigmentary lesions. This study aims to investigate the efficacy and safety of 1064 nm picosecond laser in treatment of facial melasma and skin rejuvenation in Asian skin. STUDY DESIGN/MATERIALS AND METHODS: Patients of Asian descent seeking treatment for facial melasma and skin rejuvenation were screened and recruited. Each patient received up to nine laser treatments at 4-6 weeks intervals with a fractionated nonablative 1064 nm picosecond laser. Baseline and posttreatment modified Melasma Area Severity Index (mMASI) and Global Aesthetic Improvement Scale (IGAS) were assessed by blinded investigators based on the clinical photographs. Subject overall satisfaction was assessed by the questionnaires after treatment. All adverse events were documented. RESULTS: Twenty patients were recruited with a median age of 52.7 ± 8.2 years. Three subjects had Fitzpatrick skin type III and 17 had skin type IV. All subjects received nine laser sessions. Over 70% of patients were satisfied with the treatment outcomes. There was a statistically significant improvement in mMASI which reduced from 10.8 at baseline to 2.7 and 3.6 at 6 and 12 weeks post-treatment, respectively (both P < 0.01). For skin rejuvenation, 70% reported at least a moderate improvement at 6 weeks of post-treatment. No major side-effect was reported. Erythema was the most frequent transient response, while some reported edema (1.1%). Both resolved spontaneously. None reported hypo- or hyperpigmentation after treatment. The overall mean pain scare (VAS) was 1.92. CONCLUSION: Fractionated non-ablative 1064 nm picosecond laser was effective in treatment of melasma and skin rejuvenation. It was also safe and well tolerated. Importantly, there was no hypo or hyperpigmentation reported. Lasers Surg. Med. 00:00-00, 2021. © 2021 Wiley Periodicals LLC.


Assuntos
Hiperpigmentação , Lasers de Estado Sólido , Melanose , Envelhecimento da Pele , Adulto , Povo Asiático , Humanos , Lasers de Estado Sólido/uso terapêutico , Melanose/terapia , Pessoa de Meia-Idade , Estudos Prospectivos , Rejuvenescimento , Resultado do Tratamento
9.
Lasers Surg Med ; 53(1): 9-49, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-32282094

RESUMO

BACKGROUND AND OBJECTIVES: The use of picosecond laser in dermatology was originally focused on optimizing the removal of unwanted tattoos. Subsequent advances in this technology have broadened its clinical indications to include treatment of benign pigmented lesions, photodamage, melasma, and scar revision. In this systematic review, evidence-based recommendations are developed for the use of picosecond laser in dermatology. STUDY DESIGN/MATERIALS AND METHODS: A comprehensive search of the English language literature was performed up to and including November 2019. Relevant citations were individually evaluated, synthesized, and categorized based on the Level of Evidence. With the addition of the authors' combined clinical experience, clinical recommendations were developed. RESULTS: After application of inclusion and exclusion criteria, a total of 77 unique studies were evaluated. Treatment of benign pigmented lesions was associated with level I-IV evidence; rejuvenation was associated with level II evidence; melasma was associated with level II evidence; scar revision was associated with level II-III evidence; tattoo removal was associated with level I evidence. CONCLUSION: Picosecond laser is a safe and effective treatment modality for an increasing range of dermatologic indications. Further development of this technology is warranted. Lasers Surg. Med. © 2020 Wiley Periodicals, Inc.


Assuntos
Dermatologia , Lasers de Estado Sólido , Melanose , Tatuagem , Humanos , Lasers de Estado Sólido/uso terapêutico , Rejuvenescimento
10.
Ophthalmic Physiol Opt ; 41(1): 171-178, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-33119966

RESUMO

PURPOSE: To investigate the effect of simultaneous dual-focus (DF) on retinal activities measured by global flash multifocal electroretinogram (mfERG). METHODS: Thirty adults were recruited for mfERG measurement under three conditions: in-focus (i.e., no defocus), +2.50 D DF and +7.50 D DF, administered using single vision contact lenses and DF lenses. The direct component (DC) and the induced component (IC) of the mfERG were pooled into central macular (0-8°), para-macular (8-18°) and peri-macular (18-30°) regions, and then compared across the three conditions using two-way, repeated measures ANOVA. RESULTS: Simultaneous DF had a significant effect on the IC amplitude, which was significantly stronger under +7.50 D DF (p < 0.01) than for the in-focus condition, which was mostly derived from the central and para-macular regions. No significant effect was observed for the +2.50 D DF condition. CONCLUSION: Under the effect of relatively strong simultaneous DF integration, the retina showed an enhanced retinal response, which originated from the inner retina. Compared with the peri-macular region, central and para-macular responses appeared to be enhanced.


Assuntos
Eletrorretinografia , Estimulação Luminosa , Retina/fisiologia , Adulto , Lentes de Contato , Estudos Cross-Over , Feminino , Humanos , Masculino , Adulto Jovem
11.
Laser Ther ; 29(1): 47-52, 2020 Jul 17.
Artigo em Inglês | MEDLINE | ID: mdl-32903983

RESUMO

BACKGROUND AND AIMS: Although, the pulse width should be shorter than the thermal relaxation time of the target, nanosecond laser pulses are not short enough for tattoo removal. Complications are common, such as hyper or hypopigmentation, textural changes, and scarring. Moreover, patients with darker skin types are at a higher risk of complications from tattoo removal using these lasers. Picosecond lasers were developed to overcome the limitation of nanosecond lasers. We did a comparison study of a 532/1064 nm picosecond laser vs a 532/1064 nm nanosecond laser to evaluate the clinical efficacy and complications of multi-color tattoos in Asians. MATERIALS AND METHODS: Eleven Asian patients with 37 professional tattoos were enrolled in the study. Each patient was treated with a 532/1064 nm nanosecond laser and a 532/1064 nm picosecond laser. The spot size that was used with each laser was 3 mm. Four treatments were performed, with four week intervals between each treatment. Patients were examined a week after the first treatment and 3 months after the last treatment. RESULTS AND CONCLUSIONS: All patients tolerated the treatments well. The efficacy of the 1064 nm picosecond laser for black tattoos is significantly better than the other studied lasers. The efficacy of the 532 nm picosecond laser is significantly better than the other studied lasers for red tattoos. The efficacy of the 532 nm picosecond laser is significantly better than the 532 nm nanosecond laser and better than the 1064 nm picosecond laser for green tattoos. Mild to moderate post-inflammatory hyperpigmentation was observed in 35.1%, 24.3% 27.0%, and 21.6% of the tattoos treated with the 532 nm nanosecond laser, the 532 nm picosecond laser, the 1064 nm nanosecond laser, and the 1064 nm pico-second laser, respectively. Paradoxical darkening (5.4%) was observed equally with each type of laser. There was no scar formation in any of the tattoos treated. The 532/1064 nm picosecond laser is more effective than the 532/1064 nm nanosecond laser in the treatment of multi-color tattoos in Asians. The 532 nm picosecond laser is more effective than 1064 nm picosecond laser in every tattoo color, with the exception of black. Paradoxical darkening was observed, even the use of picosecond lasers.

12.
Lasers Surg Med ; 51(1): 14-22, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-30357871

RESUMO

BACKGROUND AND OBJECTIVES: Cutaneous pigmentary disorders are both more common and more difficult to treat in patients with skin color given the higher melanin content in the epidermis. Although Q-switched lasers are widely considered to be the standard treatment for both epidermal and dermal pigmentary conditions, a very high risk of post-inflammatory hyperpigmentation (PIH) of up to 25% is seen in patients with skin of color. Recently, the novel picosecond laser with pulse durations operating at sub-nanosecond domains has been shown to be effective in tattoo removal and in the treatment of acne scars. The objective of this study is to examine the safety and efficacy of the dual wavelength picosecond laser for the treatment of benign pigmented skin lesions in Asian patients. METHODS: Twelve subjects with benign pigmentary disorders and Fitzpatrick skin types III to IV were recruited in a prospective clinical study to examine the safety and efficacy of the dual wavelength picosecond laser. Patients were treated at approximately 2-6 week intervals depending of the type of lesion. The primary efficacy endpoint is the global percent of clearance which was evaluated by blinded observers using post treatment photographs compared to baseline photographs. Safety was evaluated before and after each laser treatment and patients were asked to rate the level of pain according to the Visual Analog Scale after each treatment session. Patient satisfaction was assessed at the completion of treatment with questionnaires. All patients were followed up at 4, 8, and 12 weeks after the last treatment session. RESULTS: The pigmentary conditions treated included melasma, freckles, lentiginies, café au lait macules, and Hori's macules. Three months after treatment, 53.8% of all pigments achieved excellent response (75-94% lightening,) 30.8% of pigments achieved good response (50-74% lightening,) and 7.7% of pigments achieved both fair (25-49% lightening) and poor responses (0-24% lightening), respectively. The average number of treatment sessions required to reach at least 50% clearance was 4.5 for melasma, 1 for freckles, 1.5 for lentigines and 1 for café au lait. The patient with Hori's macules did not reach 50% clearance after a total of six treatments. Sixty three percent of patients reported satisfaction in the subjective assessment, while 27.3% were neutral and 9.1% were very dissatisfied. The post inflammatory hyperpigmentation rate was 4.8% and 6.5% of subjects developed blistering as a side effect of treatment. CONCLUSION: The dual wavelength picosecond laser is a safe and effective treatment of benign pigmentary conditions in patients with skin of color. In particular, superior clinical efficacy is demonstrated for treatment of freckles and lentigines with a low risk of PIH. Lasers Surg. Med. 51:14-22, 2019. © 2018 Wiley Periodicals, Inc.


Assuntos
Face , Hiperpigmentação/radioterapia , Lasers de Estado Sólido/uso terapêutico , Terapia com Luz de Baixa Intensidade/métodos , Adulto , Estética , Feminino , Hong Kong , Humanos , Pessoa de Meia-Idade , Segurança do Paciente , Estudos Prospectivos
13.
Lasers Surg Med ; 50(1): 13-19, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-29154457

RESUMO

BACKGROUND AND OBJECTIVE: Microfocused ultrasound (MFUS) technology has been utilized since 2009 for improvement in mild to moderate skin and soft tissue laxity of the face and neck. Few complications have been previously reported, the majority of which include mild and transient erythema, edema, ecchymosis, and nerve paralysis. Rare yet serious potential complications of MFUS for noninvasive skin tightening of the face and neck are, however, possible. METHODS & MATERIALS: Retrospective multicenter case series of five patients from the authors' practice who developed serious adverse events directly related to MFUS with a commercially available device (Ultherapy; Merz North America, Inc., Raleigh, NC). RESULTS: Five patients developed blistering, erosion/ulceration, cutaneous, or subcutaneous tissue edema with resulting atrophy, and/or cutaneous necrosis following single sessions of MFUS. CONCLUSION: Despite their rarity, serious adverse events secondary to MFUS are nevertheless possible and may be underreported. Early management of complications includes local wound care, patient reassurance, and topical corticosteroids and/or pulsed-dye laser to mitigate inflammatory sequelae. Other cosmetic and surgical therapies should be utilized when conservative measures have failed. Lasers Surg. Med. 50:13-19, 2018. © 2017 Wiley Periodicals, Inc.


Assuntos
Técnicas Cosméticas/efeitos adversos , Ablação por Ultrassom Focalizado de Alta Intensidade/efeitos adversos , Envelhecimento da Pele , Adulto , Técnicas Cosméticas/instrumentação , Face , Feminino , Ablação por Ultrassom Focalizado de Alta Intensidade/instrumentação , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
15.
Laser Ther ; 25(3): 179-184, 2016 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-27853342

RESUMO

Asian skin has a higher epidermal melanin content, making it more likely to develop adverse pigmentary reactions following laser surgery. The nanosecond lasers are the gold standard for the treatment of pigmented lesions, but the risk of complications, such as post-inflammatory hyperpigmentation, is increased in dark-skinned patients. Intense Pulsed Light (IPL) or long-pulsed lasers are available for treating superficial pigmented lesions, and fewer complications are seen when using these devices compared to the nanosecond lasers. Nanosecond lasers are essential in the treatment of dermal melanosis. Recently, picosecond lasers have been investigated. Picosecond lasers will also play an important role in the treatment of pigmented lesions.

16.
PLoS One ; 11(5): e0155071, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27187490

RESUMO

The characteristics of the on- and off-responses in the human diabetic retina by a "long-duration" multifocal electroretinogram (mfERG) paradigm were investigated. Changes in the retinal antagonistic interaction were also evaluated in the early stage of diabetes mellitus (DM). Twenty type II diabetic patients with no or mild non-proliferative diabetic retinopathy (NPDR) and twenty-one age-matched healthy controls were recruited for "long-duration" mfERG measurements. A 61-hexagon mfERG stimulus was displayed under two chromatic conditions (white/black and blue/black) at matched luminance. The amplitudes and implicit times of the on-response components (N1, P1 and N2) and off-response (P2) components were analysed. The blue stimulation generally triggered greater mfERG amplitudes in P1, N2 and P2 (p<0.05) than those from white stimulation in both control and diabetic groups. The diabetic group showed significantly greater N2 amplitude than the controls under white stimulation in mid-retinal regions (Rings 2 and 4) (p<0.05). When the stimulus was changed from white to blue, the diabetic group showed a smaller percentage change in N2 amplitude than the controls in peripheral retinal region (Ring 5) (p<0.02). When a stimulus is changed from white (broad-band spectral stimulation) to blue (narrow-band spectral stimulation), a decrease in the involvement of lateral antagonism would be expected. The larger amplitude of the on-response component (N2) in the diabetic patients suggested an imbalance of lateral antagonism, and the lesser percentage change of N2 amplitude in the diabetic group may indicate an impairment of the cross-talk at the middle retinal level in early stages of DM.


Assuntos
Retinopatia Diabética/fisiopatologia , Retina/fisiopatologia , Adulto , Análise de Variância , Biomarcadores , Glicemia , Diabetes Mellitus Tipo 2/complicações , Retinopatia Diabética/diagnóstico , Eletrorretinografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estimulação Luminosa , Tempo de Reação
17.
Lasers Surg Med ; 48(2): 203-7, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26352171

RESUMO

BACKGROUND AND OBJECTIVE: Several studies have been published on the first generation non-thermal focused ultrasound with an average improvement of 0-3.95 cm reported. We aim to investigate the efficacy of the second-generation non-thermal focused ultrasound device with a combined radiofrequency hand piece. With the addition of radiofrequency energy, the temperature of the adipose tissue is raised before focused ultrasound is applied. This facilitates the mechanical disruption of fat cells by focused ultrasound. STUDY DESIGN AND METHODS: Twenty subjects were recruited and underwent three treatments biweekly. Caliper reading, abdominal circumference, and standardized photographs were taken with the Vectra(®) system at all visits. We aim to have the subjects stand and hold the same position and the photograph taken after exhalation. Caliper and circumference measurements carry uncertainty. It is impossible to eliminate all uncertainties but can be improved by having the same trained physician assistant perform the measurement at the same site and taking an average of three readings. Pain score and satisfaction were recorded by means of the visual analogue scale. The efficacy is defined by a statistically significant improvement in circumferential improvement based on intention-to-treat analysis. RESULTS: Seventeen subjects completed the treatment schedule. Abdominal circumference showed statistically significant improvement at 2 weeks post-second treatment (P = 0.023) and almost all subsequent follow-ups. Caliper readings were statistically significant at 2 weeks post-second treatment (P = 0.013) and almost all follow-ups. The mean pain score reported was 2.3 on the visual analog scale and 6% were unsatisfied with the overall treatments. Six incidents of wheal formation appeared immediately after treatment all of which subsided spontaneously within several hours. CONCLUSION: The combination non-thermal focused ultrasound and radiofrequency device is effective for improving body contour in Asians.


Assuntos
Povo Asiático , Técnicas Cosméticas/instrumentação , Terapia por Radiofrequência , Gordura Subcutânea Abdominal , Terapia por Ultrassom/instrumentação , Adolescente , Adulto , China , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Avaliação de Resultados em Cuidados de Saúde , Satisfação do Paciente/estatística & dados numéricos , Estudos Prospectivos , Terapia por Ultrassom/métodos , Adulto Jovem
18.
PLoS One ; 10(4): e0123480, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25874564

RESUMO

The electrical response of the retina was examined as a function of retinal region, using stimuli of various spatial frequencies in the first experiment. In the second experiment, the regional response of the retina to defocus at high and low spatial frequencies was investigated. Twenty three subjects were recruited for global flash multifocal electroretinogram (mfERG) in experiment 1. Black and white gratings (printed on plastic transparent sheets) of four spatial frequencies (SF), 0.24, 1.2, 2.4 and 4.8 cycle per degree were presented in front of the mfERG stimulation. The amplitudes and implicit times of the direct (DC) and induced (IC) components of mfERG responses were pooled into six concentric rings for analysis. There was low amplitude DC at low SF, which increased with increasing SF, and which decreased with increasing eccentricity. The IC was high in amplitude at all SF and reduced in amplitude with increasing eccentricity. Our findings suggested that outer and inner retina had different characteristics in processing spatial details. In experiment 2, Twenty-three young adults were recruited for mfERG measurement. The retinal electrical responses for low (0.24cpd) and high (4.8cpd) SF under fully corrected conditions of short-term negative defocus (-2D) and short term positive defocus (+2D) conditions were measured. There was a sign-dependent response to defocus in the DC response, mainly in peripheral regions. The sign dependent response at low SF was more obvious than that at high SF, and was located more peripherally. The IC response showed no clear trends for either defocus condition. The human retina seems to have a decoding system for optical defocus, which was tuned for low spatial frequency, and was located in the retinal near periphery.


Assuntos
Eletrorretinografia/métodos , Retina/patologia , Adulto , Potenciais Evocados Visuais , Humanos , Pressão Intraocular , Miopia/patologia , Estimulação Luminosa , Erros de Refração , Reprodutibilidade dos Testes , Processamento de Sinais Assistido por Computador , Adulto Jovem
19.
Cell Transplant ; 24(3): 403-17, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25622224

RESUMO

Our previous results showed that the polysaccharides extracted from Lycium barbarum (LBP) could delay secondary degeneration of retinal ganglion cell bodies and improve the function of the retinas after partial optic nerve transection (PONT). Although the common degeneration mechanisms were believed to be shared by both neuronal bodies and axons, recently published data from slow Wallerian degeneration mutant (Wld(s)) mice supported the divergence in the mechanisms of them. Therefore, we want to determine if LBP could also delay the degeneration of axons after PONT. Microglia/macrophages were thought to be a source of reactive oxygen species after central nervous system (CNS) injury. After PONT, however, oxidative stress was believed to occur prior to the activation of microglia/macrophages in the areas vulnerable to secondary degeneration both in the optic nerves (ONs) and the retinas. But the results did not take into account the morphological changes of microglia/macrophages after their activation. So we examined the morphology in addition to the response magnitude of microglia/macrophages to determine their time point of activation. In addition, the effects of LBP on the activation of microglia/macrophages were investigated. The results showed that (1) LBP reduced the loss of axons in the central ONs and preserved the g-ratio (axon diameter/fiber diameter) in the ventral ONs although no significant effect was detected in the dorsal ONs; (2) microglia/macrophages were activated in the ONs by 12 h after PONT; (3) LBP decreased the response magnitude of microglia/macrophages 4 weeks after PONT. In conclusion, our results showed that LBP could delay secondary degeneration of the axons, and LBP could also inhibit the activation of microglia/macrophages. Therefore, LBP could be a promising herbal medicine to delay secondary degeneration in the CNS via modulating the function of microglia/macrophages.


Assuntos
Axônios/fisiologia , Medicamentos de Ervas Chinesas/farmacologia , Lycium/metabolismo , Degeneração Neural/etiologia , Traumatismos do Nervo Óptico/complicações , Animais , Axônios/efeitos dos fármacos , Comportamento Animal/efeitos dos fármacos , Medicamentos de Ervas Chinesas/uso terapêutico , Feminino , Frutas/química , Frutas/metabolismo , Medicina Herbária , Lycium/química , Macrófagos/efeitos dos fármacos , Macrófagos/imunologia , Macrófagos/fisiologia , Camundongos , Microglia/citologia , Microglia/efeitos dos fármacos , Microglia/fisiologia , Bainha de Mielina/fisiologia , Degeneração Neural/tratamento farmacológico , Fármacos Neuroprotetores/farmacologia , Fármacos Neuroprotetores/uso terapêutico , Nervo Óptico/patologia , Traumatismos do Nervo Óptico/patologia , Traumatismos do Nervo Óptico/terapia , Estresse Oxidativo/efeitos dos fármacos , Ratos , Ratos Sprague-Dawley , Retina/patologia , Degeneração Walleriana/complicações , Degeneração Walleriana/patologia
20.
Lasers Surg Med ; 46(4): 263-9, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24585511

RESUMO

BACKGROUND AND OBJECTIVES: High-intensity focused ultrasound (HIFU) is a noninvasive technology for body contouring. HIFU is focused within the subcutaneous adipose tissue, causing coagulative necrosis and cell death. The objective of this study is to evaluate the effectiveness of a HIFU device for sculpting of the abdomen. MATERIALS AND METHODS: The system has a set focal depth of 1.3 cm. Twelve subjects with adipose thickness no less than 2.5 cm who met the screening criteria were recruited. Each subject received one treatment to the abdomen. The total fluence used per site was 150-165 J/cm(2) with a mean of 161 J/cm(2) . The waist circumference at iliac crest and the point of maximum circumference were recorded at baseline, 4, 8, and 12 weeks post-treatment, as well as their weight and BMI. Subjects' rating on comfort level and satisfaction were collected via questionnaires at every follow-up. Standardized photographs were also taken with the Canfield System® at each visit. RESULTS: Seven out of 12 subjects were satisfied with the outcome and 9 out of 12 would recommend this treatment to their friends and family. There was statistically significant improvement in the waist circumference measured at both the iliac crest (P-value 0.013, 0.002, 0.005) and maximum waistline (P-value 0.003, 0.034, 0.023) at 4, 8, 12 weeks post-treatment. Spearman's rho for correlation of energy level versus improvement showed that at 12 weeks post-treatment follow-up, the improvement significantly correlated with the total fluence per treatment (P-value 0.041). The higher the total fluence delivered, the larger the decrease in waist circumference. CONCLUSIONS: High-intensity focused ultrasound effectively decreases waist circumference in Chinese. The higher the total fluence delivered, the larger the decrease in waist circumference was observed.


Assuntos
Técnicas Cosméticas , Ablação por Ultrassom Focalizado de Alta Intensidade , Gordura Subcutânea Abdominal/diagnóstico por imagem , Adolescente , Adulto , Idoso , Povo Asiático , China , Técnicas Cosméticas/instrumentação , Feminino , Seguimentos , Ablação por Ultrassom Focalizado de Alta Intensidade/instrumentação , Ablação por Ultrassom Focalizado de Alta Intensidade/métodos , Humanos , Masculino , Pessoa de Meia-Idade , Avaliação de Resultados da Assistência ao Paciente , Satisfação do Paciente , Estudos Prospectivos , Ultrassonografia , Circunferência da Cintura , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...