J Appl Clin Med Phys ; 16(6): 23-29, 2015 11 08.
Artigo em Inglês | MEDLINE | ID: mdl-26699551

RESUMO

The purpose of this study was to evaluate the dosimetric profiles and delivery accuracy of running-start-stop (RSS) delivery in tomotherapy and to present initial quality assurance (QA) results on the accuracy of the dynamic jaw motion, dosimetric penumbrae of the RSS dynamic jaw and the static jaw were measured by radiographic films. Delivery accuracy of the RSS was evaluated by gamma analysis on film measurements of 12 phantom plans. Consistency in the performance of RSS was evaluated by QA procedures over the first nine months after the installation of the feature. These QA were devised to check: 1) positional accuracy of moving jaws; 2) consistency of relative radiation output collimated by discrete and continuously sweeping jaws; 3) consistency of field widths and profiles. In the longitudinal direction, the dose penumbra in RSS delivery was reduced from 17.3mm to 10.2 mm for 2.5 cm jaw, and from 33.2 mm to 9.6 mm for 5 cm jaw. Gamma analysis on the twelve plans revealed that over 90% of the voxels in the proximity of the penumbra region satisfied the gamma criteria of 2% dose difference and 2 mm distance-to-agreement. The initial QA results during the first nine months after installation of the RSS are presented. Jaw motion was shown to be accurate with maximum encoder error less than 0.42 mm. The consistency of relative output for discrete and continuously sweeping jaws was within 1.2%. Longitudinal radiation profiles agreed to the reference profile with maximum gamma < 1 and field width error < 1.8%. With the same jaw width, RSS showed better dose penumbrae compared to those from static jaw delivery. The initial QA results on the accuracy of moving jaws, reproducibility of dosimetric output and profiles were satisfactory.


Assuntos
Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Algoritmos , Humanos , Movimento (Física) , Imagens de Fantasmas , Garantia da Qualidade dos Cuidados de Saúde , Radiometria/métodos , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/normas , Planejamento da Radioterapia Assistida por Computador/estatística & dados numéricos , Radioterapia de Intensidade Modulada/normas , Radioterapia de Intensidade Modulada/estatística & dados numéricos , Reprodutibilidade dos Testes , Filme para Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...