Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 290
Filtrar
1.
MethodsX ; 13: 102801, 2024 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-39022179

RESUMO

This article introduces a novel method for designing a fast chaotic oscillator using a CCTA (Current Conveyor Transconductance Amplifier) based on Chua's circuit. The proposed method uses innovative configurations and advanced simulation techniques to overcome challenges in high-speed operation, nonlinear dynamics, and Analog Building Block (ABB) selection. The design begins with nonlinear negative resistance, essential for Chua's diode characteristics, including two negative resistances, NR1 and NR2. The circuit integrates one CCTA block, two grounded capacitors, two fixed resistors, one inductor, and one potentiometer. It is simulated using PSPICE with IC (Integrated Circuit) macro-models and 180nm CMOS (Complementary Metal Oxide Semiconductor) technology. Various chaotic waveforms and attractors are produced, validating the theoretical and mathematical predictions. By varying the resistance values (1450Ω, 1650Ω, 1800Ω, 1950Ω), the circuit exhibits different chaotic behaviors, such as large limit cycles, double-scroll attractors, Rossler-type attractors, and I-periodic attractors. FFT (Fast Fourier Transform) analysis confirms the highest dominant operating frequency of 37.5MHz. A Monte Carlo simulation with 100 runs shows maximum voltage variations in the chaotic waveforms of 5.21 % and 4.61 % across the capacitors, demonstrating robustness and reliability. This design offers significant advancements in implementing high-frequency chaotic oscillators, with potential applications in various fields requiring chaotic signal generation.•A novel design of Chua's diode and Chua's chaotic oscillator using only one CCTA block is presented in this paper.•The proposed chaotic oscillator achieves the highest operating frequency of 37.5MHz.•The proposed circuit is simulated using commercially available ICs (MAX435 and AD844) and CMOS 180nm technology in PSPICE to confirm its workability.

2.
Small ; : e2402953, 2024 Jun 24.
Artigo em Inglês | MEDLINE | ID: mdl-38923392

RESUMO

While peptide-based drug development is extensively explored, this strategy has limitations due to rapid excretion from the body (or shorter half-life in the body) and vulnerability to protease-mediated degradation. To overcome these limitations, a novel strategy for the development of a peptide-based anticancer agent is introduced, utilizing the conformation switch property of a chameleon sequence stretch (PEP1) derived from a mycobacterium secretory protein, MPT63. The selected peptide is then loaded into a new porous organic polymer (PG-DFC-POP) synthesized using phloroglucinol and a cresol derivative via a condensation reaction to deliver the peptide selectively to cancer cells. Utilizing ensemble and single-molecule approaches, this peptide undergoes a transition from a disordered to an alpha-helical conformation, triggered by the acidic environment within cancer cells that is demonstrated. This adopted alpha-helical conformation resulted in the formation of proteolysis-resistant oligomers, which showed efficient membrane pore-forming activity selectively for negatively charged phospholipids accumulated in cancer cell membranes. The experimental results demonstrated that the peptide-loaded PG-DFC-POP-PEP1 exhibited significant cytotoxicity in cancer cells, leading to cell death through the Pyroptosis pathway, which is established by monitoring numerous associated events starting from lysosome membrane damage to GSDMD-induced cell membrane demolition. This novel conformational switch-based drug design strategy is believed to have great potential in endogenous environment-responsive cancer therapy and the development of future drug candidates to mitigate cancers.

3.
J Agromedicine ; : 1-11, 2024 Jun 17.
Artigo em Inglês | MEDLINE | ID: mdl-38886993

RESUMO

OBJECTIVE: Despite generating huge employment opportunities and profitable business, fishing is considered a dangerous occupation due to challenging weather conditions and exposure to unhealthy occupational factors and lifestyles, which contribute to various health issues. However, few studies have examined the health status of shrimp cultivators. Consequently, this study aims to estimate the age group-wise burden of non-communicable diseases (NCDs) among shrimp cultivators. METHODS: Simple random sampling was employed for collecting data. The sample size was 357 shrimp cultivators. Disability-adjusted life years (DALY) and relative risk (RR) methods were used to measure the burden of NCDs among shrimp cultivators. This study reported the burden of NCDs per 100,000 shrimp cultivators. RESULTS: The top five prevalence of NCDs per 100,000 shrimp cultivators were mental disorders (85,434), musculoskeletal diseases (26,325), digestive diseases (9,803), diabetes (5,882), and cardiovascular diseases (4,481). DALY per 100,000 shrimp cultivators was 33,407.59, while at the national level, it was 24,775.99 per 100,000 people across all age groups. The RR of NCDs among shrimp cultivators in terms of DALY was 1.35, indicating a 0.35 times higher burden of NCDs among shrimp cultivators than at the national level. The largest RR of NCDs was found among shrimp cultivators aged 15-49 years (1.85), followed by 50-69 years (1.09). The highest percentage changes in the burden of NCDs among shrimp cultivators, resulting from changes in the methods of estimating DALY, was observed in the age group of 70 years and above (-48.36%) followed by 15-49 years (-46.08%) and 50-69 years (-40.33%) when compared to the baseline method of estimating DALY without utilizing age weightage and discount rate. CONCLUSIONS: Focus should be given to improving the lifestyle and occupational factors of shrimp cultivators to mitigate the burden of NCDs.

4.
MethodsX ; 12: 102727, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38746478

RESUMO

A compact 1 × 4 antipodal Vivaldi antenna (AVA) array designed for 5 G applications is introduced in this study. An elliptical-shaped parasitic patch and corrugation are strategically employed to enhance gain and bandwidth, making it well-suited for 5 G applications. The resulting AVA array with corrugation and parasitic patch (AVA-PC) is designed and simulated on ANSYS HFSS, demonstrating a stable gain ranging from 10 dBi to 11.7 dBi over the frequency range of 23.45 GHz to 28.74 GHz. The antenna, with 25.8 mm x 22.4 mm x 0.5 mm dimensions, is implemented on Roger's RT/Duroid substrate 5880. •Design uses an antipodal Vivaldi antenna to build a 1 × 4 AVA.•The array employs corrugations and an elliptical patch as a performance enhancement technique.•Simulated results confirm the designed antenna's practical utility for 5 G applications in a band of 23.45 GHz to 28.74 GHz.

5.
Cureus ; 16(4): e58222, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38745809

RESUMO

INTRODUCTION:  Pain after breast cancer surgery is one of the main reasons for postoperative morbidity and pulmonary complications leading to increased hospital stay. Therefore, effective management of postoperative pain becomes necessary to alleviate patients' suffering and allow early mobilization and hospital discharge. Traditionally, opioids have been used to manage perioperative pain but they are associated with side effects. So, an opioid-sparing multimodal analgesia approach is used nowadays. Ultrasound-guided pectoral type-II (PEC II) block is increasingly being used to address acute postoperative pain after breast cancer surgery. However, to date, not many studies have been done regarding prolonging the duration of analgesia of PEC II blocks for postoperative pain relief in patients undergoing modified radical mastectomy (MRM). So, we undertook this study to compare the analgesic efficacy of PEC II block using dexamethasone as an adjuvant to ropivacaine versus plain ropivacaine in patients undergoing MRM. METHODS:  After obtaining approval from the institute ethics committee and written informed consent from the patients, this prospective, double-blind, parallel group, randomized controlled study was carried out at All India Institute of Medical Sciences (AIIMS) Raipur, from March 2021 to March 2022. Sixty-four female patients, aged 18 years and above, belonging to the American Society of Anesthesiologists, physical status I, II, and III, undergoing unilateral, elective MRM under general anesthesia, were randomly allocated to two groups A and B, with 32 patients in each to receive 30 mL of 0.25% ropivacaine plus 2 mL (8 mg) of dexamethasone and 30 mL of 0.25% ropivacaine plus 2 mL of normal saline, respectively. The primary outcome measure was total opioid consumption till 12 hours postoperatively. Secondary outcome measures were the difference in pain scores based on the numeric rating scale till 12 hours postoperatively, post-operative sedation scores, the incidence of postoperative nausea vomiting (PONV), and other adverse events (if any). RESULTS: The mean (SD) of morphine (mg) consumed intraoperatively was 5.50 (1.05) and 5.95 (0.86) with P = 0.033 and that consumed postoperatively was 1.00 (0.00) and 1.69 (0.93) with P <0.001 in group A and B respectively, with morphine consumption being higher in the group. The difference in the NRS score for pain at rest was statistically significant at 2 h (P=0.030), 4 h (P=0.004), 6 h (P=0.002), and, 12 h (P=0.039) time points with the score being higher in group B. The groups were comparable in terms of postoperative sedation score (P > 0.05) and incidence of postoperative nausea and vomiting. None of the patients in group A and 6.2% of the patients in group B had nausea (P = 0.492). None of the patients in either of the groups had vomiting. No other complication occurred during the entire study in either of the groups. CONCLUSION: In comparison to plain ropivacaine, the addition of dexamethasone as an adjuvant to ropivacaine for PEC II block in patients undergoing MRM significantly reduced perioperative opioid consumption and postoperative NRS scores. No significant change was noted in terms of postoperative sedation score, incidence of PONV, and other side effects between the groups. Therefore, we conclude that the analgesic efficacy of US-guided PEC II block using dexamethasone, as an adjuvant to ropivacaine is superior to that of plain ropivacaine in patients undergoing MRM.

6.
J Assoc Physicians India ; 72(1): 18-21, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38736069

RESUMO

INTRODUCTION: The world has changed tremendously for patients suffering from diabetes mellitus with the development of cutting-edge technologies like continuous glucose monitoring and flash glucose monitoring systems. Now, the details of constant fluctuations of glucose in their blood can be monitored not only by medical professionals but also by patients, and this is called glycemic variability (GV). Traditional metrics of glycemic control measurement, such as glycated hemoglobin (HbA1c), fail to reflect various short-term glycemic changes like postprandial hyperglycemia and hypoglycemic episodes, paving the way to the occurrence of various diabetic complications even in asymptomatic, well-controlled diabetic patients. This need for advanced management of diabetes and effective monitoring of these swings in blood glucose can be met by using a continuous glucose monitoring system (CGMS). AIM AND OBJECTIVE: To evaluate the extent of GV in well-controlled type 2 diabetes mellitus (T2DM) patients using a flash CGMS and to assess the correlation between GV and HbA1c. MATERIALS AND METHODS: A hospital-based prospective observational study was carried out from May 2020 to Oct 2021 at the Department of Medicine, SMS Hospital, Jaipur, Rajasthan (India), after approval from the Ethics Committee of the institution. A total of 30 patients with well-controlled T2DM (HbA1c was ≥6.5, but ≤7.5) were included in the study using simple random techniques after written informed consent from patients. Patients were studied for glycemic excursions over a period of 7 days by using FreeStyle® Libre Pro™, which is a flash glucose monitoring system. The CGM sensor was attached to the left upper arm of the patient on day 0 and removed on day 7. The data recorded in the sensor was then retrieved using pre-installed computer software and analyzed using standard CGM metrics like standard deviation (SD), percentage coefficient of variation (%CV), time above range (TAR), time below range (TBR), and time in range (TIR), out of which %CV was used to quantify GV. %CV has been used to cluster patients into four cohorts from best to worst, namely: best/low CV ≤ 10%, intermediate CV from 10 to 20%, high CV from 20 to 30%, and very high CV of >30%. Scatterplots are used to establish correlations between various parameters. RESULT: Data from a total of 30 patients were analyzed using CGMS and thus used for calculating standard CGM metrics; glucose readings every 15 minutes were recorded consecutively for 7-day periods, making it a total of 672 readings for each patient. Interpreting the CGM data of all 30 patients, the following results were found: the mean blood glucose of all cases is 134.925 ± 22.323 mg/dL, the mean SD of blood glucose of all cases is 35.348 ± 9.388 mg/dL, the mean of %CV of all cases is 26.376 ± 6.193%. CGM parameters of time are used in the form of percentages, and the following results were found: the mean of TAR, TBR, and TIR is 14.425 ± 13.211, 5.771 ± 6.808, and 82.594 ± 12.888%, respectively. Clustering the patients into cohorts, the proportion of patients exhibiting best/low %CV (10%) is 0, intermediate %CV (10-20%) is 16.67% (five out of 30 patients), high %CV (20-30%) is 50% (15 out of 30 patients) and very high %CV (>30%) is 33.33% (10 out of 30 patients). Also, there is no significant correlation found between HbA1c and %CV (ρ = 0.076, p-value = 0.690); a significant negative correlation was found between %CV and TIR (ρ = -0.604, p < 0.001S); a positive correlation of %CV with TAR and TBR is significant (ρ = 0.816, p-value of <0.001). CONCLUSION: Using a flash CGMS device and considering %CV as the parameter and primary measure of GV, the study demonstrated the overall instability of a person's glycemic control, making note of unrecognized events of hypoglycemia and hyperglycemia in asymptomatic well-controlled T2DM patients, revealing the overall volatile glycemic control. The most important finding of this study is that even those diabetics who are considered well-controlled experience a great degree of GV as assessed by CGM-derived metrics. This study also demonstrated that there is no significant correlation between HbA1c and GV, suggesting that patients may not have optimal control of their diabetes despite having "normal HbA1c" values; hence, GV can be considered an HbA1c-independent danger factor, having more harmful effects than sustained hyperglycemia in the growth of diabetic complications. So, by using CGM-derived metrics, the measurement of GV has the potential to complement HbA1c data. In this manner, a more comprehensive assessment of glycemic excursions can be provided for better treatment decisions, thereby facilitating optimal glycemic control, which is essential for reducing overall complications and promoting good quality of life.


Assuntos
Automonitorização da Glicemia , Glicemia , Diabetes Mellitus Tipo 2 , Hemoglobinas Glicadas , Humanos , Diabetes Mellitus Tipo 2/sangue , Automonitorização da Glicemia/métodos , Automonitorização da Glicemia/instrumentação , Glicemia/análise , Hemoglobinas Glicadas/análise , Feminino , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Controle Glicêmico/métodos , Adulto , Idoso , Monitoramento Contínuo da Glicose
7.
Breast Cancer Res Treat ; 206(1): 19-30, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38668856

RESUMO

BACKGROUND: Evaluation of axillary lymph nodes status in cN0 axilla is performed by sentinel lymph node biopsy (SLNB) utilizing a combination of radioactive isotope and blue dye or alternative to isotope like Indocyanine green (ICG). Both are very resource-intensive; which has prompted development of low-cost technique of Fluorescein Sodium (FS)-guided SLNB. This systematic review and meta-analysis evaluate the diagnostic performance of FS-guided SLNB in early breast cancer. OBJECTIVES: The objective was to evaluate the diagnostic performance of FS for sentinel lymph node biopsy. METHODS: Eligibility criteria: Studies where SLNB was performed using FS. INFORMATION SOURCES: PubMed, EMBASE, Cochrane library and online clinical trial registers. Risk of bias: Articles were assessed for risk of bias using the QUADAS-2 tool. SYNTHESIS OF RESULTS: The main summary measures were pooled Sentinel Lymph Node Identification Rate (SLN-IR) and pooled False Negative Rate (FNR) using random-effects model. RESULTS: A total of 45 articles were retrieved by the initial systematic search. 7 out of the 45 studies comprising a total of 332 patients were included in the meta-analysis. The pooled SLN-IR was 93.2% (95% confidence interval [CI], 0.87-0.97; 87% to 97%). Five validation studies were included for pooling the false negative rate and included a total of 211 patients. The pooled FNR was 5.6% (95% confidence interval [CI], 2.9-9.07). CONCLUSION: Fluorescein-guided SLNB is a viable option for detection of lymph node metastases in clinically node negative patients with early breast cancer. It achieves a high pooled Sentinel Lymph Node Identification Rate (SLN-IR) of 93% with a false negative rate of 5.6% for the detection of axillary lymph node metastasis.


Assuntos
Neoplasias da Mama , Fluoresceína , Metástase Linfática , Biópsia de Linfonodo Sentinela , Humanos , Biópsia de Linfonodo Sentinela/métodos , Neoplasias da Mama/patologia , Neoplasias da Mama/diagnóstico , Feminino , Metástase Linfática/diagnóstico , Metástase Linfática/patologia , Linfonodo Sentinela/patologia , Axila , Biópsia Guiada por Imagem/métodos
8.
World J Surg ; 48(6): 1433-1439, 2024 06.
Artigo em Inglês | MEDLINE | ID: mdl-38658165

RESUMO

BACKGROUND: Excess and prolonged axillary drainage is a frequent nuisance following axillary lymph node dissection (ALND) in breast cancer patients. No consensus exists about the best method to prevent this consistently and reliably. Tranexamic acid (TA) has been found to reduce the amount and duration of drainage, but the reduction is not optimal. We hypothesized that systemic administration of TA along with the topical application of hemocoagulase (H) to the axillary dissection bed may decrease the cumulative axillary drain output and shorten the requirement of drainage after ALND as compared to placebo. PATIENT AND METHODS: Seventy women undergoing ALND for breast carcinoma were randomized into two groups, the intervention (TA + H) group and the control (C) group. The cumulative drain output (primary objective), duration of drainage, incidence of seroma formation after drain removal, number of seroma aspirations required, volume of seroma aspirated, and incidence of surgical site infection (SSI) were compared. RESULTS: The mean cumulative output in the TA + H group was significantly lower than the C group (290 ± 200 mL vs. 552 ± 369 mL, p < 0.001). Axillary drains were removed significantly earlier in the TA + H group (6.6 ± 2.2 vs. 11.7 ± 6.0 days, p < 0.001), but the incidence of seroma formation (p = 0.34), number of aspirations required (p = 0.33), volume of seroma aspirated (p = 0.47), and the incidence of SSI (p = 0.07) were similar. CONCLUSIONS: Perioperative systemic administration of tranexamic acid along with topical application of H to the axillary dissection bed is effective in reducing cumulative axillary drain output after ALND. This strategy may also facilitate earlier removal of suction drains.


Assuntos
Administração Tópica , Antifibrinolíticos , Axila , Neoplasias da Mama , Drenagem , Excisão de Linfonodo , Ácido Tranexâmico , Humanos , Feminino , Ácido Tranexâmico/administração & dosagem , Ácido Tranexâmico/uso terapêutico , Neoplasias da Mama/cirurgia , Pessoa de Meia-Idade , Método Duplo-Cego , Antifibrinolíticos/administração & dosagem , Antifibrinolíticos/uso terapêutico , Drenagem/métodos , Adulto , Batroxobina/administração & dosagem , Batroxobina/uso terapêutico , Seroma/prevenção & controle , Seroma/etiologia , Idoso , Resultado do Tratamento , Assistência Perioperatória/métodos , Hemostáticos/administração & dosagem , Hemostáticos/uso terapêutico
9.
Artigo em Inglês | MEDLINE | ID: mdl-38566498

RESUMO

Abnormal cardiac functionality produces irregular heart rhythms which are commonly known as arrhythmias. In some conditions, arrhythmias are treated as very dangerous which may lead to sudden cardiac arrest. The incidence and prevalence of cardiac anomalies seeks early detection of arrhythmias using automated classification techniques. In the past, numerous automated arrhythmia detection techniques have been developed that are based on electrocardiogram (ECG) signal analysis. Focusing on the prospective research in this field, this article reports a comprehensive review of existing techniques that are obtained using search engines such as IEEE explore, Google scholar and science direct. Based on the review, the existing techniques are broadly categorized into two types: machine-learning and deep-learning-based techniques. In this study, it is noticed that the performance of the machine-learning-based arrhythmia detection techniques depend on pre-processing of ECG signal, R-peaks detection, features extraction and classification tools while the deep-learning-based techniques do not require the features extraction step. Generally, the existing techniques utilize Massachusetts Institute of Technology-Beth Israel Hospital arrhythmia database to evaluate the classification performance. The classification performance of automated techniques also depends on ECG data used for training and testing of the classifier. It is expected that the performance should be evaluated using a variety of ECG signals including the cases of inter-patient and intra-patient paradigm. The existing techniques also require to deal with the class-imbalance problem. In addition to this, a specific partition-ratio between training and testing datasets should be maintained for fair comparison of performance of different techniques.

10.
MethodsX ; 12: 102619, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38445176

RESUMO

An analog comb filter is implemented by linking multiple VDCC-based notch filters in a cascading fashion (N in total), eliminating N different pole frequencies. This study focuses on suppressing a fundamental frequency of power-line interference of 50 Hz and its consecutive three odd harmonics at 150 Hz, 250 Hz, and 350 Hz. One significant advantage of this comb filter is the independent control over filters' parameters like quality factor and pole frequency. Additionally, these filters can be electronically tuned by adjusting the transconductance gain of VDCC. The suggested notch filter configuration involves 2 capacitors, 2 resistors, and 1 VDCC element. Extensive simulations were conducted using PSPICE simulator software to validate the effectiveness of these filters. The basic building block, VDCC, is designed and implemented in the simulation using integrated circuits MAX435 and AD844.•Design uses a VDCC-based high Q notch filter as the active building block.•The filter employs fewer active and passive components.•Simulated results using commercially available ICs, MAX435 and AD844, confirm the filter's practical utility.

11.
Int J Gen Med ; 17: 1101-1116, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38529100

RESUMO

Background: The lack of focus on the health status of shrimp cultivators by previous studies while the production of shrimp has been rising over the years after the introduction of the blue revolution in India. The present study estimated the burden of diseases among shrimp cultivators in India. Methods: Primary data were collected by using simple random sampling. The sample size was 357. The classification of diseases were made by using the international classification of diseases, tenth revision (ICD-10), version 2019. Disability-adjusted life years (DALY) were used to measure the health status of shrimp cultivators. DALY is the summation of the burden of disease from mortality and morbidity. Sensitive and uncertainty analysis was used by changing the value of the parameter and method, respectively. Results: The burden of disease among shrimp cultivators in 2020 ranges from 101.03 DALY based on equal age weightage, without discount rate, and potential life expectancy (DALY0,0,PLE) to 84.02 DALY based on unequal age weightage, discount rate, and standardized life expectancy (DALY1,0.03,SLE). The burden of disease per 100,000 shrimp cultivators was 28,477.74 DALY and 23,600.84 DALY when calculated by using DALY0,0,PLE and DALY1,0.03,SLE method, respectively. The higher burden of diseases from non-communicable diseases was followed by injury and communicable diseases for both methods. The disease burden from mortality was more than two-thirds of the total burden of disease and the rest from morbidity. The burden of disease among shrimp cultivators was sensitive to parameter changes because it changes between 92.10 DALY and 63.03 DALY with the change in the parameter. Uncertainty in the burden of disease among them was due to method variation, which ranges from 120.03 DALY to 74.06 DALY. Conclusion: The higher burden of non-communicable diseases, and the lower burden of communicable, and injuries per 100,000 shrimp cultivators compared to the national level in India.

12.
J Clin Microbiol ; 62(3): e0104823, 2024 Mar 13.
Artigo em Inglês | MEDLINE | ID: mdl-38329335

RESUMO

Human granulocytic anaplasmosis (HGA) is an emerging, rickettsial tick-borne disease caused by Anaplasma phagocytophilum. Sero-epidemiological data demonstrate that this pathogen has a worldwide distribution. The diagnosis of HGA requires a high index of clinical suspicion, even in endemic areas. In recent years, HGA has increasingly been reported from Asia and described in China, Japan, and Korea. We serologically and molecularly screened 467 patients with clinical suspicion of Anaplasmosis. The present study describes the epidemiology, clinical, and laboratory details of 6 confirmed and 43 probable cases of human granulocytic anaplasmosis. One of the HGA patients developed secondary invasive opportunistic Aspergillus fumigatus and Acinetobacter baumanii infection during the illness, which resulted in a fatal infection. The HGA patients without severe complications had excellent treatment responses to doxycycline. The emergence of this newly recognized tick-borne zoonotic HGA in North India is a significant concern for public health and is likely underdiagnosed, underreported, and untreated. Hence, it is also essential to establish a well-coordinated system for actively conducting tick surveillance, especially in the forested areas of the country.IMPORTANCEThe results of the present study show the clinical and laboratory evidence of autochthonous cases of Anaplasma phagocytophilum in North India. The results suggest the possibility of underdiagnosis of HGA in this geographical area. One of the HGA patients developed secondary invasive opportunistic Aspergillus fumigatus and Acinetobacter baumanii infection during the illness, which resulted in a fatal infection.


Assuntos
Anaplasma phagocytophilum , Anaplasmose , Doenças Transmitidas por Carrapatos , Animais , Humanos , Anaplasmose/diagnóstico , Anaplasmose/tratamento farmacológico , Anaplasmose/epidemiologia , Doxiciclina/uso terapêutico , China/epidemiologia , Índia
14.
IEEE Trans Biomed Eng ; 71(7): 2033-2041, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38294922

RESUMO

Recent studies have shown that virtual gamified therapy can be a potential adjunct to conventional orthopedic rehabilitation. However, the off-the-shelf gaming consoles used for virtual rehabilitation pose several practical challenges in deploying them in clinical settings. In this article, we present the design of a portable glove-based virtual hand rehabilitation system (RehabRelive Glove) that can be used at both clinics and homes for physiotherapy. We also evaluate the system's efficacy on patients with post-traumatic hand injuries. Thirty patients were randomly categorized into groups A (virtual rehabilitation) and B (conventional physiotherapy). Both groups received fifteen 25-minute sessions of respective therapy over three weeks. The wrist and finger joints' range of motion (ROM) and grip strength were measured every seven sessions to compare the efficacy. Group A showed about 1.5 times greater improvement in flexion/extension ROM of the wrist compared to Group B. While both groups improved finger ROM and grip strength with time, no significant difference was observed between the groups. The results suggest that the proposed virtual rehabilitation system effectively enables patients with hand injuries to recover ROM faster.


Assuntos
Traumatismos da Mão , Força da Mão , Amplitude de Movimento Articular , Humanos , Traumatismos da Mão/reabilitação , Masculino , Adulto , Feminino , Força da Mão/fisiologia , Amplitude de Movimento Articular/fisiologia , Desenho de Equipamento , Pessoa de Meia-Idade , Adulto Jovem , Mãos/fisiopatologia , Modalidades de Fisioterapia/instrumentação , Realidade Virtual
15.
Trop Med Health ; 52(1): 10, 2024 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-38225634

RESUMO

Measles poses a significant global health threat, exacerbated by the COVID-19 pandemic. Despite the efficacy of two vaccine doses, under-5 mortality rates persist, with over 61 million delayed measles vaccinations worldwide. Nepal, striving to eliminate measles by 2023, faces a resurgence, attributing 1013 cases to inadequate vaccination and healthcare accessibility issues. Compounded by disruptions from the COVID-19 pandemic, the outbreak highlights the urgent need for vaccination promotion, improved healthcare access, and misinformation mitigation. This situation underscores the critical role of global collaboration and healthcare infrastructure investment to safeguard children's lives in Nepal and similar vulnerable regions.

18.
Plant Physiol ; 194(3): 1336-1357, 2024 Feb 29.
Artigo em Inglês | MEDLINE | ID: mdl-37930810

RESUMO

Plants must rapidly and dynamically adapt to changes in their environment. Upon sensing environmental signals, plants convert them into cellular signals, which elicit physiological or developmental changes that allow them to respond to various abiotic and biotic cues. Because plants can be simultaneously exposed to multiple environmental cues, signal integration between plant cells, tissues, and organs is necessary to induce specific responses. Recently, CLAVATA3/EMBRYO SURROUNDING REGION-related (CLE) peptides and their cognate CLAVATA-type receptors received increased attention for their roles in plant-environment interactions. CLE peptides are mobile signaling molecules, many of which are induced by a variety of biotic and abiotic stimuli. Secreted CLE peptides are perceived by receptor complexes on the surface of their target cells, which often include the leucine-rich repeat receptor-like kinase CLAVATA1. Receptor activation then results in cell-type and/or environment-specific responses. This review summarizes our current understanding of the diverse roles of environment-regulated CLE peptides in modulating plant responses to environmental cues. We highlight how CLE signals regulate plant physiology by fine-tuning plant-microbe interactions, nutrient homeostasis, and carbon allocation. Finally, we describe the role of CLAVATA receptors in the perception of environment-induced CLE signals and discuss how diverse CLE-CLAVATA signaling modules may integrate environmental signals with plant physiology and development.


Assuntos
Interação Gene-Ambiente , Transdução de Sinais , Transporte Biológico , Carbono , Peptídeos
19.
Chemistry ; 30(13): e202303287, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-37997510

RESUMO

An efficient and short synthesis of fused dihydroisoquinolines, diaryl substituted pyridine derivatives in good to high yields has been established by using an environmentally safe, solvent-metal-oxidant-free tandem approach. In this article, we discuss how the electrocyclic reaction is more pronounced in the solid phase in the presence of urea, whereas the typical aza-Michael addition is more prominent in presence of arylamine in the solution phase for 3-(2-formylcycloalkenyl)acrylic ester derivative substrates. The wide range of substrates and urea-promoted neat synthesis made our approach more significant in medical and also analytical science. Moreover, an isoquinoline alkaloid decumbenine B analogue has been synthesized by using our newly developed neat methodology. We have also investigated the photophysical properties of the synthesized fused dihydroisoquinoline derivatives. One of the synthesized molecules was used as a sensor for the selective detection of toxic picric acid. Therefore, the effective neat synthesis and molecular sensing applications of these compounds made our approach more exciting in the field of heterocyclic chemistry.

20.
Breast Dis ; 42(1): 395-399, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38108339

RESUMO

Lymphedema (LE) in a breast cancer patient usually results from axillary lymph node dissection, sentinel lymph node biopsy, and/or axillary radiotherapy. Although lymphatic obstruction and consequent LE can occur due to axillary lymph node involvement, such presentation in breast cancer patients has rarely been reported. This report describes the case of a 50-year-old lady with right breast carcinoma who presented with right upper limb lymphedema. Surprisingly, she did not have any bulky axillary lymphadenopathy that could have accounted for lymphedema of the upper limb, but a suspicious breast mass was present on clinical examination. Diagnosis of breast cancer on clinical examination can be challenging in such patients due to breast edema and careful imaging of the breast and axilla with appropriate imaging tools (mammogram, ultrasound, MRI, PET mammography) should be resorted to before excluding malignancy. Lymphoscintigraphy confirmed the findings of lymphedema in the right upper limb and revealed uptake in the epitrochlear lymph nodes of the contralateral limb suggesting that she might had pre-existing widespread "subclinical lymphedema" which presented as "clinical lymphedema" in right upper limb after axillary lymph node/lymphatic involvement by right breast carcinoma.


Assuntos
Neoplasias da Mama , Carcinoma , Linfedema , Feminino , Humanos , Pessoa de Meia-Idade , Neoplasias da Mama/complicações , Extremidade Superior , Linfedema/diagnóstico por imagem , Linfedema/etiologia , Mama , Axila
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...