1.
Echocardiography ; 29(3): E60-1, 2012 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22098371

RESUMO

Bedside pericardiocentesis is a safe and routinely practiced procedure. We report a case in which echocardiography-guided pericardiocentesis was performed urgently for cardiac tamponade. In this case, there was displacement of the periocardiocentesis needle that was only detected by change in the color of aspirated fluid and confirmed by the use of contrast echocardiography. We prescribe the use of routine echocardiographic monitoring during pericardiocentesis to avoid this type of complication.


Assuntos
Tamponamento Cardíaco/cirurgia , Ecocardiografia/métodos , Migração de Corpo Estranho/diagnóstico por imagem , Migração de Corpo Estranho/etiologia , Agulhas/efeitos adversos , Pericardiocentese/efeitos adversos , Ultrassonografia de Intervenção/métodos , Meios de Contraste , Migração de Corpo Estranho/prevenção & controle , Humanos , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento