1.
Echocardiography ; 29(5): 509-12, 2012 May.
Artigo em Inglês | MEDLINE | ID: mdl-22429086

RESUMO

BACKGROUND: This investigation was designed to determine whether transient wall motion abnormalities due to myocardial ischemia induced by walking could be detected by ambulatory echocardiography. METHODS: Two groups were studied. Group 1 consisted of 10 males (mean age 34 years) who had no symptoms of angina. Group 2 consisted of eight selected patients (mean 61 years) with angina and angiographic evidence of coronary artery disease. The 2.5 MHz transducer is spherical in its distal part and mounted in an external housing to permit steering in 360°. The external housing was attached to the chest wall using an adhesive patch. The transducer was placed in the 3rd or 4th intercostal space at the left sternal border to permit imaging of the left ventricle (LV) in its short axis and attached to the chest wall. The transducer was interfaced with an Acuson Cypress echocardiography system which was placed on a mobile cart. To permit portability, the echocardiography system was powered by a capacitor (UPS device). The subjects were asked to walk along the corridor as fast as possible for 10 minutes or until the onset of symptoms while pushing the cart. The short axis of the LV was displayed on a monitor and recorded on optical disks. RESULTS: The heart rate, systolic blood pressure (SBP), and double product of Group 1 at rest were 77 ± 3 beats/min, 119 ± 13 mmHg, and 9,150 ± 868, respectively, and increased to 106 ± 8 beats/min, 129 ± 15 mmHg, and 1,3793 ± 2,176 with walking. The baseline heart rate, SBP, and double product were 71 ± 12 beats/min, 130 ± 14 mmHg, and 8,555 ± 1,928 in Group 2 and increased to 94 ± 14 beats/min, 135 ± 20 mmHg, and 12,480 ± 3,830 with walking. All patients in Group 1 had normal wall motion at rest and during walking. Patients in Group 2 had normal wall motion during rest and new wall motion abnormalities were noted in all subjects during walking (anterior septum and/or anterolateral wall in seven, posterolateral wall in one). The wall motion abnormalities resolved shortly after discontinuation of walking. CONCLUSION: Ambulatory echocardiography permitted the detection of transient wall motion abnormalities in patients with coronary artery disease (CAD). This technique could be potentially useful in evaluating selected patients for myocardial ischemia.


Assuntos
Ecocardiografia/instrumentação , Ecoencefalografia/instrumentação , Monitorização Ambulatorial/instrumentação , Transdutores , Disfunção Ventricular Esquerda/diagnóstico por imagem , Desenho de Equipamento , Análise de Falha de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
2.
Echocardiography ; 26(10): 1211-6, 2009 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-19725859

RESUMO

Coronary vascular responses to the cold pressor test (CPT) have been shown to parallel changes caused by infusion of acetylcholine. Whereas the CPT is a method of assessing endothelial-dependent vasodilation, nitroglycerin produces endothelial-independent vasodilation. We performed histological studies on autopsy specimens of abdominal aorta and demonstrated that it is predominantly muscular artery. To test the hypothesis that vasodilatory responses of the abdominal aorta to interventions would parallel those of peripheral vessels, 33 normal males without hypertension, diabetes, or hyperlipidemia, and 10 younger male smokers had ultrasound imaging of the abdominal aorta conducted in the control state, 2 minutes after immersion of the hand in cold water and 10 minutes after rewarming the hand (i.e., cold pressor test). The internal diameter of the abdominal aorta at the onset of the QRS complex was determined for each intervention by averaging 4 beats. It was found that the cold pressor test and nitroglycerin resulted in similar degrees of dilation of the abdominal aorta in nonsmoking subjects, and that these responses were attenuated in smokers. Thus, both endothelial-dependent and endothelial-independent vascular relaxation were impaired in smokers.


Assuntos
Aorta Abdominal/diagnóstico por imagem , Aorta Abdominal/fisiopatologia , Temperatura Baixa , Endotélio Vascular/efeitos dos fármacos , Endotélio Vascular/fisiopatologia , Nitroglicerina , Fumar/fisiopatologia , Vasodilatação/efeitos dos fármacos , Adulto , Aorta Abdominal/efeitos dos fármacos , Feminino , Humanos , Masculino , Nitroglicerina/administração & dosagem , Ultrassonografia