Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Am J Cardiol ; 229: 13-21, 2024 Aug 14.
Artigo em Inglês | MEDLINE | ID: mdl-39151818

RESUMO

A single high-sensitivity troponin-T (hs-TnT) measurement may be sufficient to risk-stratify emergency department (ED) patients with possible acute coronary syndrome (ACS) using the recalibrated History, Electrocardiogram, Age, Risk Factors, Troponin (rHEART) score. We sought to validate this approach in a multiethnic population of United States patients and investigate gender-specific differences in performance. We conducted a secondary analysis of a prospective cohort study of adult ED patients with possible ACS at a single, urban, academic hospital. We investigated the diagnostic performance of rHEART for the incidence of type-1 acute myocardial infarction (AMI) and other major adverse cardiac events (MACE) at 30 days, using both single (19 ng/L) and gender-specific (14 ng/L for women, 22 ng/L for men) 99th percentile hs-TnT thresholds. The 821 patients included were 54% women, 57% Hispanic, and 26% Black. Overall, 4.6% of patients had MACE, including 2.4% with AMI. Single-threshold rHEART ≤3 had a sensitivity of 94.4% (95% confidence interval 81% to 99%) and negative predictive values of 99.3% (98% to 100%) for MACE; gender-specific thresholds performed nearly identically. Sensitivity and negative predictive values for AMI were 90.0% (67% to 98%) and 99.3% (97% to 100%). Excluding patients presenting <3 hours from symptom onset improved sensitivity for MACE and AMI to 97.0% (84% to 100%) and 94.1% (71% to 100%). Logistic regression demonstrated odds of MACE increased with higher rHEART scores at a similar rate for men and women. In conclusion, a single initial hs-TnT and rHEART score can be used to risk-stratify male and female ED patients with possible ACS, especially when drawn >3 hours after symptom onset.

2.
Crit Pathw Cardiol ; 22(4): 103-109, 2023 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-37782621

RESUMO

Clinical pathways are useful tools for conveying and reinforcing best practices to standardize care and optimize patient outcomes across myriad conditions. The NewYork-Presbyterian Healthcare System has utilized a clinical chest pain pathway for more than 20 years to facilitate the timely recognition and management of patients presenting with chest pain syndromes and acute coronary syndromes. This chest pain pathway is regularly updated by an expanding group of key stakeholders, which has extended from the Columbia University Irving Medical Center to encompass the entire regional healthcare system, which includes 8 hospitals. In this 2023 update of the NewYork-Presbyterian clinical chest pain pathway, we present the key changes to the healthcare system-wide clinical chest pain pathway.


Assuntos
Síndrome Coronariana Aguda , Humanos , Síndrome Coronariana Aguda/complicações , Síndrome Coronariana Aguda/diagnóstico , Síndrome Coronariana Aguda/terapia , Procedimentos Clínicos , Dor no Peito/diagnóstico , Dor no Peito/etiologia , Dor no Peito/terapia , Atenção à Saúde
3.
Am J Cardiol ; 203: 240-247, 2023 09 15.
Artigo em Inglês | MEDLINE | ID: mdl-37506670

RESUMO

Many algorithms for emergency department (ED) evaluation of acute coronary syndrome (ACS) using high-sensitivity troponin assays rely on the detection of a "delta," the difference in concentration over a predetermined interval, but collecting specimens at specific times can be difficult in the ED. We evaluate the use of troponin "velocity," the rate of change of troponin concentration over a flexible short interval for the prediction of major adverse cardiac events (MACEs) at 30 days. We conducted a prospective, observational study on a convenience sample of 821 patients who underwent ACS evaluation at a high-volume, urban ED. We determined the diagnostic performance of a novel velocity-based algorithm and compared the performance of 1- and 2-hour algorithms adapted from the European Society of Cardiology (ESC) using delta versus velocity. A total of 7 of 332 patients (2.1%) classified as low risk by the velocity-based algorithm experienced a MACE by 30 days compared with 35 of 221 (13.8%) of patients classified as greater than low risk, yielding a sensitivity of 83.3% (95% confidence interval [CI] 68.6% to 93.0%) and negative predictive value (NPV) of 97.9% (95% CI 95.9% to 98.9%). The ESC-derived algorithms using delta or velocity had NPVs ranging from 98.4% (95% CI 96.4% to 99.3%) to 99.6% (95% CI 97.0% to 99.9%) for 30-day MACEs. The NPV of the novel velocity-based algorithm for MACE at 30 days was borderline, but the substitution of troponin velocity for delta in the framework of the ESC algorithms performed well. In conclusion, specimen collection within strict time intervals may not be necessary for rapid evaluation of ACS with high-sensitivity troponin.


Assuntos
Síndrome Coronariana Aguda , Infarto do Miocárdio , Humanos , Troponina , Síndrome Coronariana Aguda/diagnóstico , Infarto do Miocárdio/diagnóstico , Estudos Prospectivos , Valor Preditivo dos Testes , Serviço Hospitalar de Emergência , Troponina T , Biomarcadores , Algoritmos
4.
J Am Coll Emerg Physicians Open ; 3(3): e12739, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35571147

RESUMO

Study Objective: To evaluate whether the introduction of a 1-hour high-sensitivity cardiac troponin-T (hs-TnT) pathway for patients who present to the emergency department (ED) with suspected acute coronary syndrome (ACS) improves ED patient flow without changing the rate of "missed" major adverse cardiac events (MACE), compared to use of conventional cardiac troponin with an associated 3-hour pathway. Methods: This was a prospective, uncontrolled observational study conducted before and after implementation of a 1-hour hs-TnT pathway at a high-volume urban ED. Patients undergoing evaluation for ACS in the ED were enrolled during their initial visit and clinical outcomes were assessed at 30 and 90 days. Throughput markers were extracted from the electronic medical record and compared. The primary outcome was provider-to-disposition decision time. Results: A total of 1892 patients were enrolled, 1071 patients while using conventional troponin and 821 after introduction of hs-TnT. With the new assay and pathway, median interval between troponin tests decreased from 4.7 hours (interquartile range [IQR] 3.9-5.7 hours) to 2.3 hours (IQR 1.5-3.4 hours) (P < 0.001). However, there was no difference in median provider-to-disposition decision time, which measured 4.7 hours (IQR 2.9-7.2) and 4.8 hours (IQR 3.1-7.1) (P = 0.428) respectively. Total 30-day MACE rate in discharged patients was low in both groups, occurring in only 4/472 (0.85%) encounters in the first cohort and 4/381 (1.0%) encounters in the second. Conclusion: Introduction of a 1-hour hs-TnT ACS evaluation pathway reduced the troponin collection interval but did not reduce provider to disposition time. There was no difference in rate of 30-day MACE in patients discharged from the ED.

5.
Emerg Med Clin North Am ; 38(3): 573-587, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32616280

RESUMO

Emergency department crowding is a multifactorial issue with causes intrinsic to the emergency department and to the health care system. Understanding that the causes of emergency department crowding span this continuum allows for a more accurate analysis of its effects and a more global consideration of potential solutions. Within the emergency department, boarding of inpatients is the most appreciable effect of hospital-wide crowding, and leads to further emergency department crowding. We explore the concept of emergency department crowding, and its causes, effects, and potential strategies to overcome this problem.


Assuntos
Aglomeração , Serviço Hospitalar de Emergência/organização & administração , Eficiência Organizacional , Serviço Hospitalar de Emergência/estatística & dados numéricos , Humanos
6.
AMIA Annu Symp Proc ; 2018: 897-906, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30815132

RESUMO

Emergency departments across the U.S. are more congested than ever, and there is a pressing need to create capacity by improving patient flow. The long turnaround time of imaging tests, such as computed tomography (CT) scans, are a major reason for delays in treatment and disposition. Over an eight-month pre-intervention period during which 10,063 CT scans were ordered in our emergency department, the average time from a CT order to the availability of the radiologist's final report was 5.9 hours (median=4.2 hours). We created a multi-disciplinary team of physicians, nurses, technicians, transporters, informaticians, and engineers to identify barriers and implement technical as well as human-factors solutions. In the corresponding eight-month period after the implementation of the intervention bundle, there was a 1.2 hour reduction in CT turnaround time, despite a 13.8% increase in the number of CT scans ordered (p<0.0001).


Assuntos
Serviço Hospitalar de Emergência/organização & administração , Tempo para o Tratamento , Tomografia Computadorizada por Raios X , Análise de Dados , Humanos , Equipe de Assistência ao Paciente , Recursos Humanos em Hospital/educação , Serviço Hospitalar de Radiologia/organização & administração , Fluxo de Trabalho
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA