Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
ACS Appl Mater Interfaces ; 15(41): 48277-48286, 2023 Oct 18.
Artigo em Inglês | MEDLINE | ID: mdl-37801021

RESUMO

Mn-based layered oxides have been considered the most promising cathode candidates for cost-effective potassium-ion batteries (PIBs). Herein, equiatomic constituents of Ni, Fe, Mg, and Ti have been introduced into the transition metal layers of Mn-based layered oxide to design a high-entropy K0.6Ni0.05Fe0.05Mg0.05Ti0.05Mn0.0725O2 (HE-KMO, S = 1.17R). Consequently, the experimental results manifest that the layered structure of HE-KMO is more stable than conventional low-entropy K0.6MnO2 (LE-KMO, S = 0.66R) during successive cycling and even upon exposure to moisture. Diffraction and electrochemical measurements reveal that HE-KMO undergoes a solid-solution mechanism, contrary to the multistage phase transition processes typically exemplified in K0.6MnO2. Benefiting from the stabilized high-entropy layered framework and the solid-solution K+ storage mechanism, the entropy-stabilized HE-KMO not only demonstrates exceptional rate capability but also shows excellent cyclic stability. Notably, a capacity retention ratio of 86% after 3000 cycles can still be sustained at a remarkable current density of 5000 mA g-1.

2.
Opt Express ; 17(7): 5279-84, 2009 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-19333293

RESUMO

Emission spectral tomography (EST) has been adopted to test the three-dimensional distribution parameters of fluid fields, such as burning gas, flame and plasma etc. In most cases, emission spectral data received by the video cameras are enormous so that the emission spectral tomography calculation is often time-consuming. Hence, accelerating calculation becomes the chief factor that one must consider for the practical application of EST. To solve the problem, a hardware implementation method was proposed in this paper, which adopted a digital signal processor (DSP) DM642 in an emission spectral tomography test system. The EST algorithm was fulfilled in the DSP, then calculation results were transmitted to the main computer via the user datagram protocol. Compared with purely VC++ software implementations, this new approach can decrease the calculation time significantly.


Assuntos
Algoritmos , Monitoramento Ambiental/instrumentação , Processamento de Sinais Assistido por Computador/instrumentação , Análise Espectral/instrumentação , Tomografia Óptica/instrumentação , Emissões de Veículos/análise , Desenho Assistido por Computador , Desenho de Equipamento , Análise de Falha de Equipamento , Sistemas On-Line , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...