Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 24
Filtrar
1.
J Adv Nurs ; 2024 Jun 26.
Artigo em Inglês | MEDLINE | ID: mdl-38924169

RESUMO

AIM: To evaluate the effectiveness of utilizing the integrated pulmonary index for capnography implementation during sedation administered by nurses. DESIGN: Cluster-randomized trial. METHODS: Participants were enrolled from the interventional radiology department at an academic hospital in Canada. Nurses were randomized to either enable or disable the Integrated Pulmonary Index feature of the capnography monitor. Procedures were observed by a research assistant to collect information about alarm performance characteristics. The primary outcome was the number of seconds in an alert condition state without an intervention being applied. RESULTS: The number of seconds in an alarm state without intervention was higher in the group that enabled the integrated pulmonary index compared to the group that disabled this feature, but this difference did not reach statistical significance. Likewise, the difference between groups for the total alarm duration, total number of alarms and the total number of appropriate alarms was not statistically significant. The number of inappropriate alarms was higher in the group that enabled the Integrated Pulmonary Index, but this estimate was highly imprecise. There was no difference in the odds of an adverse event (measured by the Tracking and Reporting Outcomes of Procedural Sedation tool) occurring between groups. Desaturation events were uncommon and brief in both groups but the area under the SpO2 90% desaturation curve scores were lower for the group that enabled the integrated pulmonary index. CONCLUSION: Enabling the integrated pulmonary index during nurse-administered procedural sedation did not reduce nurses' response times to alarms. Therefore, integrating multiple physiological parameters related to respiratory assessment into a single index did not lower the threshold for intervention by nurses. IMPLICATIONS FOR THE PROFESSION AND/OR PATIENT CARE: The time it takes to respond to capnography monitor alarms will not be reduced if the integrated pulmonary Iindex feature of capnography monitors is enabled during nurse-administered procedural sedation. IMPACT: Results do not support the routine enabling of the integrated pulmonary index when nurses use capnography to monitor patients during procedural sedation as a strategy to reduce the time it takes to initiate responses to alarms. REPORTING METHOD: CONSORT. PATIENT OR PUBLIC CONTRIBUTION: There was no patient or public contribution. TRIAL REGISTRATION: This study was prospectively registered at ClinicalTrials.gov (ID: NCT05068700).

2.
J Perianesth Nurs ; 2024 May 28.
Artigo em Inglês | MEDLINE | ID: mdl-38819359

RESUMO

PURPOSE: Many patients undergoing surgical and other medical procedures requiring sedation or anesthesia receive standardized "no eating or drinking after midnight" instructions. This "standardized" instruction does not change regardless of potential alterations in scheduling that result in significant delays in procedure start times. As a result, the duration of preprocedure fasting often far exceeds recommended requirements. A technological solution that automates the delivery of preprocedure fasting instructions to patients would likely improve the patient experience. The purpose of this study was to determine design specifications for the delivery of notifications to patients as part of an automated system. DESIGN: A qualitative study was conducted with 14 adult participants using the persona-scenario method. METHODS: Participants worked in groups to create realistic but fictitious personas and scenarios that described how individuals like themselves would interact with an automated preprocedure fasting instruction system. Data generated through the development of the scenarios were analyzed to first identify important themes, which were then interpreted into design specifications. FINDINGS: Seven women and seven men, aged 25 to 75, developed 9 persona-scenarios, which captured outpatient and inpatient preprocedure fasting experiences, as well as perspectives of individuals who were not comfortable with technology, or those for which English was not the primary spoken language. Most scenarios described preprocedure fasting instructions delivered by an automated bidirectional short message service system. Two major themes were identified as patient priorities, including: (1) enhancing communication between patients and healthcare providers; and (2) the importance of using simple technology so that a greater number of patients with varying degrees of comfort and capabilities would be able to use the system confidently. A corresponding set of proposed design specifications was devised. CONCLUSIONS: The results of this study provide actionable ways to operationalize patient-centered ideas in the design of an automated preprocedure fasting instruction system.

3.
Opt Lett ; 49(7): 1684-1687, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38560836

RESUMO

Dual-comb spectroscopy in the ultraviolet (UV) and visible would enable broad bandwidth electronic spectroscopy with unprecedented frequency resolution. However, there are significant challenges in generation, detection, and processing of dual-comb data that have restricted its progress in this spectral region. In this work, we leverage robust 1550 nm few-cycle pulses to generate frequency combs in the UV-visible. We combine these combs with a wavelength multiplexed dual-comb spectrometer and simultaneously retrieve 100 MHz comb-mode-resolved spectra over three distinct harmonics at 386, 500, and 760 nm. The experiments highlight the path to continuous dual-comb coverage spanning 200-750 nm, offering extensive access to electronic transitions in atoms, molecules, and solids.

4.
J Adv Nurs ; 78(7): 2245-2254, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35485238

RESUMO

AIM: To determine if smart alarm-guided treatment of respiratory depression using the Integrated Pulmonary Index is an effective way to implement capnography during nurse-administered sedation. DESIGN: Parallel cluster-randomized trial. METHODS: Nurses will be randomized to use capnography with or without the Integrated Pulmonary Index enabled. Capnography alarm performance will be compared between nurses using capnography alone or with the Integrated Pulmonary Index enabled. The target sample size is 400 adult patients scheduled for elective procedures with nurse-administered sedation. The primary outcome is the number of seconds in an alert condition state without an intervention being applied. Secondary outcomes are alarm burden, number of appropriate alarms, number of inappropriate alarms, total duration of alert conditions, choice of alarm settings and adverse sedation events. This study has been funded since April 2021. DISCUSSION: Implementing capnography into practice for respiratory monitoring during nurse-administered sedation is considered a high priority. The Integrated Pulmonary Index shows promise as a strategy to optimize the implementation of capnography for respiratory monitoring during nurse-administered sedation. If it is found in this study that using the Integrated Pulmonary Index improves the nursing management of physiologically abnormal states during nurse-administered sedation, it would provide the high-level evidence needed to support broader use of this 'smart alarm' strategy for respiratory monitoring in practice. IMPACT: With advances in medical technology continuing to expand the indications for minimally invasive surgical techniques, the use of nurse-administered sedation during medical procedures is likely to expand in the future. The findings may be applied to other populations receiving nurse-administered sedation during medical procedures. Results from this study will help translate the usage of smart alarm-guided treatment of respiratory depression during procedural sedation. TRIAL REGISTRATION: NCT05068700.


Assuntos
Capnografia , Insuficiência Respiratória , Adulto , Capnografia/métodos , Humanos , Monitorização Fisiológica/métodos , Ensaios Clínicos Controlados Aleatórios como Assunto
5.
J Chem Phys ; 156(11): 114304, 2022 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-35317567

RESUMO

The photodissociation dynamics of alkyl iodides along the C-I bond are captured by attosecond extreme-ultraviolet (XUV) transient absorption spectroscopy employing resonant ∼20 fs UV pump pulses. The methodology of previous experiments on CH3I [Chang et al., J. Chem. Phys. 154, 234301 (2021)] is extended to the investigation of a C-I bond-breaking reaction in the dissociative A-band of C2H5I, i-C3H7I, and t-C4H9I. Probing iodine 4d core-to-valence transitions in the XUV enables one to map wave packet bifurcation at a conical intersection in the A-band as well as coherent vibrations in the ground state of the parent molecules. Analysis of spectroscopic bifurcation signatures yields conical intersection crossing times of 15 ± 4 fs for CH3I, 14 ± 5 fs for C2H5I, and 24 ± 4 fs for i-C3H7I and t-C4H9I, respectively. Observations of coherent vibrations, resulting from a projection of A-band structural dynamics onto the ground state by resonant impulsive stimulated Raman scattering, indirectly reveal multimode C-I stretch and CCI bend vibrations in the A-bands of C2H5I, i-C3H7I, and t-C4H9I.

6.
JMIR Perioper Med ; 4(2): e29200, 2021 Oct 05.
Artigo em Inglês | MEDLINE | ID: mdl-34609322

RESUMO

BACKGROUND: Capnography is commonly used for nurse-administered procedural sedation. Distinguishing between capnography waveform abnormalities that signal the need for clinical intervention for an event and those that do not indicate the need for intervention is essential for the successful implementation of this technology into practice. It is possible that capnography alarm management may be improved by using machine learning to create a "smart alarm" that can alert clinicians to apneic events that are predicted to be prolonged. OBJECTIVE: To determine the accuracy of machine learning models for predicting at the 15-second time point if apnea will be prolonged (ie, apnea that persists for >30 seconds). METHODS: A secondary analysis of an observational study was conducted. We selected several candidate models to evaluate, including a random forest model, generalized linear model (logistic regression), least absolute shrinkage and selection operator regression, ridge regression, and the XGBoost model. Out-of-sample accuracy of the models was calculated using 10-fold cross-validation. The net benefit decision analytic measure was used to assist with deciding whether using the models in practice would lead to better outcomes on average than using the current default capnography alarm management strategies. The default strategies are the aggressive approach, in which an alarm is triggered after brief periods of apnea (typically 15 seconds) and the conservative approach, in which an alarm is triggered for only prolonged periods of apnea (typically >30 seconds). RESULTS: A total of 384 apneic events longer than 15 seconds were observed in 61 of the 102 patients (59.8%) who participated in the observational study. Nearly half of the apneic events (180/384, 46.9%) were prolonged. The random forest model performed the best in terms of discrimination (area under the receiver operating characteristic curve 0.66) and calibration. The net benefit associated with the random forest model exceeded that associated with the aggressive strategy but was lower than that associated with the conservative strategy. CONCLUSIONS: Decision curve analysis indicated that using a random forest model would lead to a better outcome for capnography alarm management than using an aggressive strategy in which alarms are triggered after 15 seconds of apnea. The model would not be superior to the conservative strategy in which alarms are only triggered after 30 seconds.

7.
J Chem Phys ; 154(23): 234301, 2021 Jun 21.
Artigo em Inglês | MEDLINE | ID: mdl-34241252

RESUMO

Extreme ultraviolet (XUV) transient absorption spectroscopy has emerged as a sensitive tool for mapping the real-time structural and electronic evolution of molecules. Here, attosecond XUV transient absorption is used to track dynamics in the A-band of methyl iodide (CH3I). Gaseous CH3I molecules are excited to the A-band by a UV pump (277 nm, ∼20 fs) and probed by attosecond XUV pulses targeting iodine I(4d) core-to-valence transitions. Owing to the excellent temporal resolution of the technique, passage through a conical intersection is mapped through spectral signatures of nonadiabatic wave packet bifurcation observed to occur at 15 ± 4 fs following UV photoexcitation. The observed XUV signatures and time dynamics are in agreement with previous simulations [H. Wang, M. Odelius, and D. Prendergast, J. Chem. Phys. 151, 124106 (2019)]. Due to the short duration of the UV pump pulse, coherent vibrational motion in the CH3I ground state along the C-I stretch mode (538 ± 7 cm-1) launched by resonant impulsive stimulated Raman scattering and dynamics in multiphoton excited states of CH3I are also detected.

8.
Intensive Crit Care Nurs ; 67: 103091, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34244028

RESUMO

OBJECTIVE: To summarize the evidence regarding the accuracy of continuous non-invasive arterial pressure measurements in adult critical care patients. RESEARCH METHODOLOGY: Medline, EMBASE, and CINAHL were searched for studies that included adult critical care patients reporting the agreement between continuous non-invasive and invasive arterial pressure measurements. The studies were selected and assessed for risk of bias using the Revised Quality Assessment of Diagnostic Accuracy Studies tool by two independent reviewers. The Grading of Recommendations, Assessment, Development and Evaluations approach was used. Pooled estimates of the mean bias and limits of agreement with outer 95% confidence intervals (termed population limits of agreement) were calculated. RESULTS: Population limits of agreement for systolic blood pressure were wide, spanning from -36.13 mmHg to 28.28 mmHg (18 studies; 785 participants). Accuracy of diastolic blood pressure measurements was highly inconsistent across studies, resulting in imprecise estimates for the population limits of agreement. Population limits of agreement for mean arterial pressure spanned from -39.96 mmHg to 44.36 mmHg (17 studies; 765 participants). The evidence was rated as very low-quality due to very serious concerns about heterogeneity and imprecision. CONCLUSION: Substantial differences in blood pressure were identified between measurements taken from continuous non-invasive and invasive monitoring devices. Clinicians should consider this broad range of uncertainty if using these devices to inform clinical decision-making in critical care.


Assuntos
Pressão Arterial , Cuidados Críticos , Adulto , Pressão Sanguínea , Humanos
9.
Struct Dyn ; 8(3): 034104, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-34169117

RESUMO

Attosecond extreme ultraviolet (XUV) and soft x-ray sources provide powerful new tools for studying ultrafast molecular dynamics with atomic, state, and charge specificity. In this report, we employ attosecond transient absorption spectroscopy (ATAS) to follow strong-field-initiated dynamics in vinyl bromide. Probing the Br M edge allows one to assess the competing processes in neutral and ionized molecular species. Using ab initio non-adiabatic molecular dynamics, we simulate the neutral and cationic dynamics resulting from the interaction of the molecule with the strong field. Based on the dynamics results, the corresponding time-dependent XUV transient absorption spectra are calculated by applying high-level multi-reference methods. The state-resolved analysis obtained through the simulated dynamics and related spectral contributions enables a detailed and quantitative comparison with the experimental data. The main outcome of the interaction with the strong field is unambiguously the population of the first three cationic states, D 1, D 2, and D 3. The first two show exclusively vibrational dynamics while the D 3 state is characterized by an ultrafast dissociation of the molecule via C-Br bond rupture within 100 fs in 50% of the analyzed trajectories. The combination of the three simulated ionic transient absorption spectra is in excellent agreement with the experimental results. This work establishes ATAS in combination with high-level multi-reference simulations as a spectroscopic technique capable of resolving coupled non-adiabatic electronic-nuclear dynamics in photoexcited molecules with sub-femtosecond resolution.

10.
Syst Rev ; 10(1): 69, 2021 03 05.
Artigo em Inglês | MEDLINE | ID: mdl-33673878

RESUMO

BACKGROUND: Midazolam is used for sedation before diagnostic and therapeutic medical procedures by several routes including oral, intravenous, intranasal and intramuscular. This is an update of a Cochrane review published in 2016, which aimed to determine the evidence on the effectiveness of midazolam for sedation when administered before a diagnostic or therapeutic procedure in adults and children. METHODS: We searched CENTRAL, MEDLINE, Embase and two trials registers up to May 2020 together with reference checking to identify additional studies. We imposed no language restrictions. Randomized controlled trials of midazolam in comparison with placebo or other medications used for sedation were included. Two authors independently extracted data and assessed risk of bias for each included study. RESULTS: Eight new trials were included in this update, which resulted in changed conclusions for the intravenous midazolam versus placebo, oral midazolam versus chloral hydrate and oral midazolam versus placebo comparisons. Effect estimates for all outcomes within the intravenous midazolam versus placebo (7 trials; 633 adults and 32 children) are uncertain due to concerns about imprecision and risk of bias. Midazolam resulted in a higher level of sedation than placebo (mean difference (MD) 1.05; 95% confidence interval (95% CI) 0.69 to 1.41; 1 study; 100 adults). There was no difference in anxiety (RR 0.43, 95% CI 0.09 to 1.99; I2 = 75%; 2 studies; 123 adults). Risk of difficulty performing procedures was lower in the midazolam group (RR 0.5; 95% CI 0.29 to 0.86; I2 = 45%; 3 studies; 191 adults and 32 children). There was no difference in discomfort (RR 0.51; 95% CI 0.25 to 1.04; I2 = 0%; 2 studies; 190 adults). Five trials with 336 children were included in the oral midazolam versus chloral hydrate comparison. Midazolam was less likely to result in moderate sedation (RR 0.30, 95% CI 0.11 to 0.82; I2 = 64%; 2 studies, 228 participants). This effect estimate is highly uncertain due to concerns about the risk of bias, imprecision and inconsistency. There was no difference in ratings of anxiety (SMD - 0.26; 95% CI - 0.75 to 0.23; I2 = 0%; 2 studies; 68 participants). Midazolam increased risk of incomplete procedures (RR 4.01; 95% CI 1.92 to 8.40; I2 = 0%; 4 studies, 268 participants). This effect estimate is uncertain due to concerns about the risk of bias. There were four trials with 359 adults and 77 children included in the oral midazolam versus placebo comparison. Midazolam reduced ratings of anxiety (SMD - 1.01; 95% CI - 1.86 to - 0.16; I2 = 92%; 4 studies; 436 participants). It is unclear if midazolam has an effect on difficulty performing procedures. Meta-analysis was not performed because there was only one incomplete procedure in the midazolam group in one of the trials. Midazolam reduced pain in one study with 99 adults (MD - 2; 95% CI - 2.5 to - 1.6; moderate quality). The effect estimate is uncertain due to concerns about the risk of bias. CONCLUSION: The additional evidence arising from inclusion of new studies in this updated review has not produced sufficient high-quality evidence to determine whether midazolam produces more effective sedation than other medications or placebo in any specific population included in this review. For adults, there was low-quality evidence that intravenous midazolam did not reduce the risk of anxiety or discomfort/pain in comparison to placebo, but the sedation level was higher. By combining results from adults and children, there was low-quality evidence of a large reduction in the risk of procedures being difficult to perform with midazolam in comparison to placebo. The effect estimates for this comparison are uncertain because there was concern about risk of bias and imprecision. There is moderate-quality evidence suggesting that oral midazolam produces less-effective sedation than chloral hydrate for completion of procedures for children undergoing non-invasive diagnostic procedures. Ratings of anxiety were not different between oral midazolam and chloral hydrate. The extent to which giving oral midazolam to adults or children decreases anxiety during procedures compared with placebo is uncertain due to concerns about risk of bias and imprecision. There was moderate-quality evidence from one study that oral midazolam reduced the severity of discomfort/pain for adults during a brief diagnostic procedure in comparison with placebo.


Assuntos
Hidrato de Cloral , Midazolam , Administração Intranasal , Adulto , Ansiedade , Criança , Humanos
11.
Nurs Open ; 8(3): 1135-1144, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33507607

RESUMO

AIM: To develop the Nursing Confidence in Managing Sedation Complications Scale. DESIGN: A multi-phased approach was used. METHODS: An initial bank of items was created based on the authors' experience and clinical practice guidelines. An expert panel assessed content validity. Exploratory factor analysis was used for item reduction and regression was used to explore construct validity. Responsiveness was evaluated using a pre-test post-test design. RESULTS: Criteria for content validity was met for 34 items. An 18-item, three-factor solution was identified from exploratory factor analysis performed using Nursing Confidence in Managing Sedation Complications Scale scores from 228 nurses. Subscales accounted for 66% of the variance. Cronbach's alpha for the scale (0.95) and subscales was high (>0.85). There were differences (p < .001) in Nursing Confidence in Managing Sedation Complications Scale scores relative to years of experience and work environment. NC-MSCS scores increased significantly from before to after sedation training (mean difference = 31.8; 95% CI = 24.4-39; N = 31).


Assuntos
Local de Trabalho , Análise Fatorial , Humanos , Psicometria , Reprodutibilidade dos Testes , Inquéritos e Questionários
12.
Eur J Anaesthesiol ; 38(8): 839-849, 2021 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-33492872

RESUMO

BACKGROUND: High flow nasal oxygen may better support the vulnerable respiratory state of patients during procedural sedation. OBJECTIVE: The objective of this study was to investigate the effects of high flow nasal oxygen in comparison to facemask oxygen on ventilation during cardiac implantable electronic device procedures performed with procedural sedation. DESIGN: A randomised controlled trial. SETTING: The study was conducted at one academic hospital in Canada. PARTICIPANTS: Adults undergoing elective cardiac implantable electronic device procedures with sedation administered by an anaesthesia assistant, supervised by an anaesthesiologist from August 2019 to March 2020. INTERVENTIONS: Participants were randomised 1 : 1 to facemask (≥ 8 l ·â€Šmin-1) or high flow nasal oxygen (50 l ·â€Šmin-1 and a 50 : 50 oxygen to air ratio). MAIN OUTCOME MEASURES: The primary outcome was peak transcutaneous carbon dioxide. Outcomes were analysed using Bayesian statistics. RESULTS: The 129 participants who were randomised and received sedation were included. The difference in peak transcutaneous carbon dioxide was 0.0 kPa (95% CI -0.17 to 0.18). Minor adverse sedation events were 6.4 times more likely to occur in the high flow nasal oxygen group. This estimate is imprecise (95% CI 1.34 to 42.99). The odds ratio for oxygen desaturation for the high flow nasal oxygen group compared with the facemask group was 1.2 (95% CI 0.37 to 3.75). The difference in satisfaction with sedation scores between groups was 0.0 (95% CI -0.33 to 0.23). CONCLUSIONS: Ventilation, as measured by TcCO2, is highly unlikely to differ by a clinically important amount between high flow nasal oxygen at 50 l min-1 or facemask oxygen at 8 l min-1. Further research with a larger sample size would be required to determine the optimal oxygen:air ratio when using high flow nasal oxygen during cardiac implantable electronic device procedures performed with sedation. TRIAL REGISTRATION NUMBER: NCT03858257.


Assuntos
Máscaras , Oxigênio , Adulto , Teorema de Bayes , Canadá , Eletrônica , Humanos , Oxigenoterapia
13.
J Clin Monit Comput ; 35(1): 39-49, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-32488679

RESUMO

Zero-heat-flux thermometers provide clinicians with the ability to continuously and non-invasively monitor body temperature. These devices are increasingly being used to substitute for more invasive core temperature measurements during surgery and in critical care. The aim of this review was to determine the accuracy and precision of zero-heat-flux temperature measurements from the 3M™ Bair Hugger™ Temperature Monitoring System. Medline and EMBASE were searched for studies that reported on a measurement of core or peripheral temperature that coincided with a measurement from the zero-heat-flux device. Study selection and quality assessment was performed independently using the Revised Quality Assessment of Diagnostic Accuracy Studies tool (QUADAS-2). The Grading of Recommendations, Assessment, Development and Evaluations (GRADE) approach was used to summarize the strength of the evidence. Pooled estimates of the mean bias and limits of agreement with outer 95% confidence intervals (population limits of agreement) were calculated. Sixteen studies were included. The primary meta-analysis of zero-heat-flux versus core temperature consisted of 22 comparisons from 16 individual studies. Data from 952 participants with 314,137 paired measurements were included. The pooled estimate for the mean bias was 0.03 °C. Population limits of agreement, which take into consideration the between-study heterogeneity and sampling error, were wide, spanning from - 0.93 to 0.98 °C. The GRADE evidence quality rating was downgraded to moderate due to concerns about study limitations. Population limits of agreement for the sensitivity analysis restricted to studies rated as having low risk of bias across all the domains of the QUADAS-2 were similar to the primary analysis. The range of uncertainty in the accuracy of a thermometer should be taken into account when using this device to inform clinical decision-making. Clinicians should therefore consider the potential that a temperature measurement from a 3M™ Bair Hugger™ Temperature Monitoring System could be as much as 1 °C higher or lower than core temperature. Use of this device may not be appropriate in situations where a difference in temperature of less than 1 °C is important to detect.


Assuntos
Temperatura Alta , Termômetros , Temperatura Corporal , Humanos , Monitorização Fisiológica , Temperatura
14.
J Appl Gerontol ; 40(12): 1807-1817, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-33158386

RESUMO

It is widely recognized that the engagement of older adults with multimorbidity and their caregivers as partners in health care research is important and invaluable. The objective of this study was to examine how researchers can best engage and support older adults with multimorbidity and informal friend or family caregivers of older adults with multimorbidity as research partners in health care research teams. The persona-scenario method was used for participants to create fictional stories. These stories were analyzed to shed light on specific strategies that can support older adults and caregivers as partners on health care research teams, such as a patient-centered approach, identifying and addressing barriers to engagement, and clarifying roles and responsibilities on the research team. The results from this study can be used to inform research, policy, and education on supporting older adults with multimorbidity and caregivers of older adults with multimorbidity as research partners.


Assuntos
Cuidadores , Multimorbidade , Idoso , Pesquisa sobre Serviços de Saúde , Humanos , Equipe de Assistência ao Paciente , Pesquisa Qualitativa
15.
Nat Commun ; 11(1): 4042, 2020 Aug 12.
Artigo em Inglês | MEDLINE | ID: mdl-32788648

RESUMO

Conical intersections between electronic states often dictate the chemistry of photoexcited molecules. Recently developed sources of ultrashort extreme ultraviolet (XUV) pulses tuned to element-specific transitions in molecules allow for the unambiguous detection of electronic state-switching at a conical intersection. Here, the fragmentation of photoexcited iso-propyl iodide and tert-butyl iodide molecules (i-C3H7I and t-C4H9I) through a conical intersection between 3Q0/1Q1 spin-orbit states is revealed by ultrafast XUV transient absorption measuring iodine 4d core-to-valence transitions. The electronic state-sensitivity of the technique allows for a complete mapping of molecular dissociation from photoexcitation to photoproducts. In both molecules, the sub-100 fs transfer of a photoexcited wave packet from the 3Q0 state into the 1Q1 state at the conical intersection is captured. The results show how differences in the electronic state-switching of the wave packet in i-C3H7I and t-C4H9I directly lead to differences in the photoproduct branching ratio of the two systems.

17.
J Clin Monit Comput ; 34(5): 1061-1068, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-31571021

RESUMO

Capnography monitoring is recommended for use during procedural sedation. This study examined associations between capnography waveform abnormalities and the onset of apnea. Capnography waveforms from a sample of 102 participants undergoing moderate procedural sedation with bolus doses of midazolam and fentanyl were analyzed using a mixed effects Cox model. Patients were at increased risk of apnea (classified as end-tidal carbon dioxide concentration of zero) while demonstrating a capnography waveform abnormality classified as hypopnea (more than 10% increase or decrease from baseline end-tidal carbon dioxide concentration) (Hazard Ratio 2.14; 95% CI 1.75 to 2.62). Risk of apnea was not increased during capnography waveform abnormalities classified as bradypnea (capnography-derived respiratory rate less than 8 breaths/min) (Hazard Ratio 0.64; 95% CI 0.33 to 1.25). These estimates were similar when apneic episodes were defined as only those that lasted more than 20 s duration. Deciphering which capnography waveform abnormalities should promote intervention (and therefore alarms to signal the event to clinicians) from those that do not is an essential step towards successful implementation of this technology into practice. Our results indicate that using information about the history of previous capnography waveform abnormalities may be a promising solution to assist prediction of apneic episodes.


Assuntos
Analgesia , Capnografia , Apneia/diagnóstico , Sedação Consciente , Humanos , Midazolam/efeitos adversos
18.
Sci Rep ; 9(1): 10214, 2019 07 15.
Artigo em Inglês | MEDLINE | ID: mdl-31308455

RESUMO

Identifying common patterns in capnography waveform abnormalities and the factors that influence these patterns could yield insights to optimize responses to sedation-induced respiratory depression. Respiratory state sequences for 102 patients who had a procedure in a cardiac catheterisation laboratory with procedural sedation and analgesia were developed by classifying each second of procedures into a state of normal breathing or other capnography waveform abnormalities based on pre-specified cut-offs for respiratory rate and end-tidal CO2 concentration. Hierarchical clustering identified four common patterns in respiratory state sequences, which were characterized by a predominance of the state assigned normal breathing (n = 42; 41%), hypopneic hypoventilation (n = 38; 38%), apnea (n = 15; 15%) and bradypneic hypoventilation (n = 7; 7%). A multivariable distance matrix regression model including demographic and clinical variables explained 28% of the variation in inter-individual differences in respiratory state sequences. Obstructive sleep apnea (R2 = 2.4%; p = 0.02), smoking status (R2 = 2.8%; p = 0.01), Charlson comorbidity index score (R2 = 2.5%; p = 0.021), peak transcutaneous carbon dioxide concentration (R2 = 4.1%; p = 0.002) and receiving an intervention to support respiration (R2 = 5.6%; p = 0.001) were significant covariates but each explained only small amounts of the variation in respiratory state sequences. Oxygen desaturation (SpO2 < 90%) was rare (n = 3; 3%) and not associated with respiratory state sequence trajectories.


Assuntos
Anestesia/efeitos adversos , Capnografia/métodos , Dióxido de Carbono/análise , Adulto , Agnosia , Analgesia/métodos , Cateterismo Cardíaco , Sedação Consciente/métodos , Feminino , Humanos , Hipnóticos e Sedativos/farmacologia , Hipoventilação/fisiopatologia , Masculino , Monitorização Fisiológica/métodos , Oximetria/métodos , Dor , Manejo da Dor , Estudos Prospectivos , Respiração , Taxa Respiratória/fisiologia
19.
Science ; 365(6448): 79-83, 2019 07 05.
Artigo em Inglês | MEDLINE | ID: mdl-31273121

RESUMO

The electronic character of photoexcited molecules can abruptly change at avoided crossings and conical intersections. Here, we report direct mapping of the coupled interplay between electrons and nuclei in a prototype molecule, iodine monobromide (IBr), by using attosecond transient absorption spectroscopy. A few-femtosecond visible pulse resonantly excites the [Formula: see text], Y(0+), and Z(0+) states of IBr, and the photodissociation dynamics are tracked with an attosecond extreme-ultraviolet pulse that simultaneously probes the I-4d and Br-3d core-level absorption edges. Direct comparison with quantum mechanical simulations unambiguously identifies the absorption features associated with adiabatic and diabatic channels at the B/Y avoided crossing and concurrent two-photon dissociation processes that involve the Y/Z avoided crossing. The results show clear evidence for rapid switching of valence-electronic character at the avoided crossing.

20.
Phys Rev Lett ; 120(23): 233201, 2018 Jun 08.
Artigo em Inglês | MEDLINE | ID: mdl-29932679

RESUMO

Experiments are presented on real-time probing of coherent electron dynamics in xenon initiated by strong-field double ionization. Attosecond transient absorption measurements allow for characterization of electronic coherences as well as relative ionization timings in multiple electronic states of Xe^{+} and Xe^{2+}. A high degree of coherence g=0.4 is observed between ^{3}P_{2}^{0}-^{3}P_{0}^{0} of Xe^{2+}, whereas for other possible pairs of states the coherences are below the detection limits of the experiments. A comparison of the experimental results with numerical simulations based on an uncorrelated electron-emission model shows that the coherences produced by strong-field double ionization are more selective than predicted. Surprisingly short ionization time delays, 0.85 fs, 0.64 fs, and 0.75 fs relative to Xe^{+} formation, are also measured for the ^{3}P_{2}, ^{3}P_{0}, and ^{3}P_{1} states of Xe^{2+}, respectively. Both the unpredicted selectivity in the formation of coherence and the subfemtosecond time delays of specific states provide new insight into correlated electron dynamics in strong-field double ionization.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...