Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Clin Radiol ; 69(3): 254-62, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24286935

RESUMO

AIM: To investigate the feasibility of assessing vertebral marrow adipose tissue using a magnetic resonance imaging (MRI) chemical shift-based water-fat separation technique at 3 T. MATERIAL AND METHODS: A modified Dixon technique was performed to obtain the vertebral marrow fat fraction (FF) in a study of 58 postmenopausal females (age range 49.2-77.4 years), including 24 normal bone density, 19 osteopaenia, and 15 osteoporosis as documented with dual-energy X-ray absorptiometry. The reliability of FF measurements performed by two radiologists independently was evaluated with the intraclass correlation coefficient (ICC). Ten participants were scanned twice to assess the reproducibility of FF measurements. FF values were compared between each vertebral level and between groups. RESULTS: The mean coefficient of variation of FF measurements was 2.1%. According to the ICC, the measurements were reliable (ICC = 0.900 for normal bone density, ICC = 0.937 for osteopaenia and ICC = 0.909 for osteoporosis, p < 0.001 for all). There was an inverse association between mean FF at L1-L4 vertebrae and lumbar spine BMD (r = -0.459, p = 0.006), which remained significant even after controlling for confounders (age, height, and body weight). FF values at different vertebral levels were significantly correlated to each other (r = 0.703-0.921, p < 0.05 for all). There was a general trend toward increased marrow adiposity for more inferior vertebral bodies. Patients with osteopaenia and osteoporosis had a higher marrow fat content compared with normal bone mass after adjusting for confounders, although no significant differences in each vertebral level and average marrow fat content were found between the osteopaenia and osteoporosis groups. CONCLUSION: Chemical shift-based water-fat separation enables the quantitation of vertebral marrow adiposity with excellent reproducibility, which appears to be a useful method to provide complementary information to osteoporosis-related research fields.


Assuntos
Tecido Adiposo/patologia , Imageamento por Ressonância Magnética/métodos , Coluna Vertebral/patologia , Absorciometria de Fóton , Tecido Adiposo/diagnóstico por imagem , Idoso , Densidade Óssea , Doenças Ósseas Metabólicas/diagnóstico por imagem , Doenças Ósseas Metabólicas/patologia , Estudos de Viabilidade , Feminino , Humanos , Pessoa de Meia-Idade , Osteoporose Pós-Menopausa/diagnóstico por imagem , Osteoporose Pós-Menopausa/patologia , Reprodutibilidade dos Testes , Coluna Vertebral/diagnóstico por imagem
2.
J Environ Qual ; 43(5): 1566-75, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25603242

RESUMO

A soil quality (SQ) assessment and rating framework that is quantitative, iterative, and adaptable, with justifiable weighting for quality scores, is required for evaluating site-specific SQ at land reclamation sites. Such a framework needs to identify the minimum dataset that reflects the current knowledge regarding relationships between SQ indicators and relevant measures of ecosystem performance. Our objective was to develop nonlinear scoring functions for assessing the impact on SQ of peat-mineral mix (PMM) used as a cover soil at land reclamation sites. Soil functional indicators affected by PMM were extracted from existing databases and correlated with soil organic carbon (SOC). Based on defined objectives for SQ assessment, indicators with significant correlation ( < 0.05) to SOC were selected, normalized, and fitted to sigmoid functions using nonlinear regression procedure to establish SQ functions (SQFs) that can analyze changes in field capacity, permanent wilting point, soil nitrogen, and cation exchange capacity of PMM using SOC as input parameter. Application of the SQFs to an independent dataset produced ratings with mean differences similar to the treatment effects of mixing three levels of peat and mineral soil. These results show that derived ratings and weighing factors using SOC reflect the relationship between PMM treatment and other SQ indicators. Applying the developed SQFs to a long-term soil monitoring dataset shows that an increase or decrease in SOC from 10 to 20 g kg causes a significant change in SQ. This identifies the need for further nutrient and moisture management of PMM to support long-term SQ development in land reclamation.

3.
Radiat Res ; 171(3): 332-41, 2009 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-19267560

RESUMO

Monte Carlo simulations are used in the development of a nanotechnology-based multi-pixel beam array small animal microirradiation system. The microirradiation system uses carbon nanotube field emission technology to generate arrays of individually controllable X-ray pixel beams that electronically form irregular irradiation fields having intensity and temporal modulation without any mechanical motion. The microirradiation system, once developed, will be incorporated with the micro-CT system already developed that is based on the same nanotechnology to form an integrated image-guided and intensity-modulated microirradiation system for high-temporal-resolution small animal research. Prospective microirradiation designs were evaluated based on dosimetry calculated using EGSnrc-based Monte Carlo simulations. Design aspects studied included X-ray anode design, collimator design, and dosimetric considerations such as beam energy, dose rate, inhomogeneity correction, and the microirradiation treatment planning strategies. The dosimetric properties of beam energies between 80-400 kVp with varying filtration were studied, producing a pixel beam dose rate per current of 0.35-13 Gy per min per mA at the microirradiation isocenter. Using opposing multi-pixel-beam array pairs reduces the dose inhomogeneity between adjacent pixel beams to negligible levels near the isocenter and 20% near the mouse surface.


Assuntos
Método de Monte Carlo , Terapia por Raios X/métodos , Animais , Eletrodos , Estudos de Viabilidade , Humanos , Camundongos , Nanotubos de Carbono , Neoplasias/patologia , Neoplasias/radioterapia , Imagens de Fantasmas , Radiometria , Dosagem Radioterapêutica , Terapia por Raios X/instrumentação
4.
Calcif Tissue Int ; 71(3): 249-55, 2002 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-12154396

RESUMO

Noncollagenous matrix proteins (NCPs) of dental hard tissues (dentin, cementum) are involved, both temporally and spatially, in the mineralization of their collagen matrices. Two of the NCPs thought to initiate mineral nucleation and control crystal growth in dentin, are dentin phosphoproteins (DPP) and dentin sialoprotein (DSP). Control of crystal growth would depend on the binding capacity of these two molecules, which may be related to the charge domains on the crystals and/or the phosphorylation of the protein. Phosphophoryn (a highly phosphorylated DPP) and DSP were isolated, purified, and characterized from the immature root apicies of human teeth. Dephosphorylation of phosphophoryn was carried out using bovine intestinal alkaline phosphatase. Enamel crystals were prepared from the maturation stage of developing rat incisor enamel. Protein-coated crystals were prepared for viewing in an atomic force microscope fluid cell using tapping mode. Desorption of the proteins was achieved using a phosphate buffer and surface roughness measurements were obtained from all specimens. Time-lapsed images of the crystals showed "nanospheres" of protein distributed along the crystals but only the phosphophoryn-coated crystals showed a distinctive banding pattern, which was still visible after the phosphate desorption experiments. The surface roughness measurements were statistically greater (P <0.01) when compared to the control for only the phosphophoryn-coated specimens. It is hypothesized that the phosphophoryn binding may be associated with charge arrays on the crystal surface and its phosphorylation. Also, based on its affinity for the crystalsurfaces, phosphophoryn seems the most likely candidate for controlling dentin crystal growth and morphology.


Assuntos
Dentina/metabolismo , Microscopia de Força Atômica/métodos , Minerais/metabolismo , Fosfoproteínas/metabolismo , Cristalização , Dentina/química , Dentina/ultraestrutura , Humanos , Minerais/análise , Fosfoproteínas/análise , Ligação Proteica , Propriedades de Superfície
5.
ScientificWorldJournal ; 1 Suppl 2: 407-14, 2001 Oct 23.
Artigo em Inglês | MEDLINE | ID: mdl-12805877

RESUMO

Screening and selecting tree genotypes that are responsive to N additions and that have high nutrient use efficiencies can provide better genetic material for short-rotation plantation establishment. A pot experiment was conducted to test the hypotheses that (1) sweetgum ( Liquidambar styraciflua L.) families have different patterns in biomass production and allocation, N uptake, and N use efficiency (NUE), because of their differences in growth strategies, and (2) sweetgum families that are more responsive to N additions will also have greater nutrient use efficiencies. Seedlings from two half-sib families (F10022 and F10023) that were known to have contrasting responses to fertility and other stress treatments were used for an experiment with two levels of N (0 vs. 100 kg N/ha equivalent) and two levels of P (0 vs. 50 kg P/ha equivalent) in a split-plot design. Sweetgum seedlings responded to N and P treatments rapidly, with increases in both size and biomass production, and those responses were greater with F10023 than with F10022. Growth response to N application was particularly strong. N and P application increased the proportional allocation of biomass to leaves. Under increased N supply, P application increased foliar N concentration and content, as well as total N uptake by the seedlings. However, NUE was decreased by N addition and was higher in F10023 than in F10022 when P was not limiting. A better understanding of genotype by fertility interactions is important in selecting genotypes for specific site conditions and for optimizing nutrient use in forestry production.


Assuntos
Biomassa , Fertilização/fisiologia , Liquidambar/genética , Liquidambar/fisiologia , Nitrogênio/metabolismo , Plântula/genética , Plântula/fisiologia , Fertilidade/fisiologia , Genótipo , Liquidambar/crescimento & desenvolvimento , Liquidambar/metabolismo , Nitrogênio/farmacologia , Fósforo/metabolismo , Fósforo/farmacologia , Estruturas Vegetais/genética , Estruturas Vegetais/crescimento & desenvolvimento , Estruturas Vegetais/metabolismo , Estruturas Vegetais/fisiologia , Estações do Ano , Plântula/crescimento & desenvolvimento , Plântula/metabolismo , Árvores/genética , Árvores/crescimento & desenvolvimento , Árvores/metabolismo , Árvores/fisiologia
6.
Med Phys ; 27(5): 948-59, 2000 May.
Artigo em Inglês | MEDLINE | ID: mdl-10841397

RESUMO

Two intensity modulation radiotherapy (IMRT) delivery systems, the "step & shoot" multileaf collimator (MLC) auto-sequence and the use of an intensity modulator, are compared with emphasis on the dose optimization quality and the treatment irradiation time. The intensity modulation (IM) was created by a dose gradient optimization algorithm which maximizes the target dose uniformity while maintaining dose to critical structures below a set tolerance defined by the user in terms of either a single dose value or a dose volume histogram curve for each critical structure. Two clinical cases were studied with and without dose optimization: a three-field sinus treatment and a six-field nasopharyngeal treatment. The optimization goal of the latter case included the sparing of several nearby normal structures in addition to the target dose uniformity. In both cases, the target dose uniformity initially improved quickly as the IM level increased to 5, then started to approach saturation when the MLC technique was used. In the absence of the both space and intensity discreteness intrinsic to the MLC technique, the modulator technique produced greater tumor dose uniformity and normal structure sparing. The latter showed no systematic improvement with increasing IM level using the MLC technique. For the sinus tumor treatment of 2 Gy the treatment irradiation time of the modulator technique is no more than that of the conventional treatment. For the MLC technique the irradiation time increased rapidly from 4.4 min to 12.4 min as the IM level increased from 2 to 10. Both clinical cases suggested that an IM level of 5 offered a good compromise between the dose optimization quality and treatment irradiation time. We showed that a realistic photon source model is necessary for dose computation accuracy in the MLC-IM treatments.


Assuntos
Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia Conformacional/métodos , Algoritmos , Fenômenos Biofísicos , Biofísica , Seio Etmoidal , Humanos , Neoplasias Nasofaríngeas/radioterapia , Neoplasias dos Seios Paranasais/radioterapia , Controle de Qualidade , Planejamento da Radioterapia Assistida por Computador/normas , Planejamento da Radioterapia Assistida por Computador/estatística & dados numéricos , Radioterapia Conformacional/normas , Radioterapia Conformacional/estatística & dados numéricos , Fatores de Tempo
7.
Int J Radiat Oncol Biol Phys ; 45(5): 1305-14, 1999 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-10613327

RESUMO

PURPOSE: Several intensity modulation (IM) treatment techniques for tangential breast irradiation were evaluated in terms of dose uniformity in the treated breast volume, contralateral breast dose, and treatment irradiation time. METHODS AND MATERIALS: Contralateral breast dose was measured via TLD chips, and the dose uniformity was calculated on two anthropomorphic phantoms. IM was applied to all beams or to the lateral-medial (LM) beam only. The techniques evaluated include (a) IM via "step & shoot" multileaf collimator (MLC), (b) IM via intensity modulator (compensator), (c) virtual wedge, and (d) physical wedge. A dose optimization algorithm was used for the first two techniques. RESULTS: Collimator-generated IM techniques (MLC-IM and the virtual wedge) produced 50% (average) less contralateral breast dose than the conventional two-wedge technique. When the compensator or the physical wedge was used, contralateral breast dose was reduced 30% (average) by leaving the ML beam open. CONCLUSION: The treatments generated by dose optimization algorithm and delivered via the compensator and MLC techniques offered superior dose uniformity. Single-beam IM techniques in general use less irradiation time without significant degradation of dose uniformity. The MLC-IM technique in this study required the longest treatment irradiation time, while the virtual wedge and compensator IM techniques required the least.


Assuntos
Algoritmos , Neoplasias da Mama/radioterapia , Imagens de Fantasmas , Dosagem Radioterapêutica , Mama , Fenômenos Físicos , Física , Planejamento da Radioterapia Assistida por Computador , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...