Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Int J Biol Macromol ; 262(Pt 2): 129986, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38360231

RESUMO

Until now, many efficient catalysts have been reported that are used for the reduction of nitroarenes. However, a catalyst reusability is a challenge that is often faced in practical environment. In this report, we designed a hydrogel composite (CMC-LDH), which act as support and making it possible to address this challenge. In this research work, zinc/aluminum based layered double hydroxides (Zn/Al LDH) have been assembled with carboxymethyl cellulose (CMC) to prepare CMC/LDH hydrogel beads. The CMC/LDH hydrogel beads were prepared by the ionotropic gelation method. For CMC/LDH/Au preparation, the already prepared CMC/LDH beads were kept in gold ion (Au3+) solution, and their subsequent reduction with sodium borohydride (NaBH4). For the characterization of the prepared samples different instrumental techniques, such as Fourier transform infrared spectroscopy (FTIR), X-ray diffraction (XRD), energy-dispersive X-ray spectroscopy, and scanning electron microscopy (SEM) were adopted. For the catalytic evaluation of CMC/LDH/Au, it was utilized as a catalyst in 4-NP and 4-NA reduction reactions. The continuity of the reaction was monitored by a UV-visible spectrophotometer. Rate constant (kapp) of 0.48474 min-1 and 0.7486 min-1 were obtained for 4-NP and 4-NA reduction, respectively. The hydrogel beads were recycled and reused for up to five successive cycles without significantly changing their catalytic efficiency.


Assuntos
Carboximetilcelulose Sódica , Nanopartículas Metálicas , Compostos de Zinco , Carboximetilcelulose Sódica/química , Ouro , Nanopartículas Metálicas/química , Hidrogéis/química , Zinco , Compostos Orgânicos , Hidróxidos/química
2.
Gels ; 10(1)2024 Jan 20.
Artigo em Inglês | MEDLINE | ID: mdl-38275850

RESUMO

Carbon nanotube-glue composite gel-based surface-type elastic sensors with a cylindrical shape deformable (flexible) metallic body were fabricated for tactile pressure and compressive displacement sensing. The fabrication of the sensors was performed using the rubbing-in technique. The effect of the pressure and the compressive displacement on the capacitance and the impedance of the sensors were investigated at various frequencies (in the range of 1 kHz to 200 kHz). It was found that under the effect of pressure from 0 to 9 g/cm2, the capacitance increased by 1.86 and 1.78 times, while the impedance decreased by 1.84 and 1.71 times at the frequencies of 1 kHz to 200 kHz, respectively. The effect of displacement on the impedance and the capacitance of the device was also investigated at various frequencies from 1 kHz to 200 kHz. The results showed that under the effect of compressive displacement up to 25 µm, the impedance of the sensors decreased on average by 1.19 times, while the capacitance increased by 1.09 times, accordingly. The frequency response of the displacement sensor showed that it matched with the low-pass filter. The obtained results are explained based on changes in the shape and geometrical parameters of the cylindrical-shaped conductive body. These results have also been explained on the basis of the distance between the conductive plates of the capacitive sensors during compression, which takes place under the effect of applied pressure or displacement. Moreover, the design of the sensors is simple and easy to fabricate, and their use is also earthy. The fabricated sensors have great potential for commercialization.

3.
Gels ; 9(9)2023 Sep 05.
Artigo em Inglês | MEDLINE | ID: mdl-37754402

RESUMO

Optimized surface-type impedimetric and capacitive proximity sensors have been fabricated on paper substrates by using rubbing-in technology. The orange dye (OD) and silicone glue (SG) composite-gel films were deposited on the zig-zag gap between two aluminum electrodes fixed on a paper (dielectric) substrate. The effect of proximity of various objects (receivers) on the impedance and the capacitance of the sensors was investigated. These objects were semi-cylindrical aluminum (metallic) foil, a cylindrical plastic tube filled with water, a kopeck-shaped plastic tube filled with carbon nanotubes and a human finger. The mechanism of sensing was based on the change in impedance and/or the capacitance of the sensors with variation of proximity between the surfaces of the sensor and the object. On decreasing proximity, the impedance of the sensors increased while the capacitance decreased. The impedimetric proximity sensitivities of CNT, water, metal-based receivers and the finger were up to 60 × 103 Ω/mm, 35 × 103 Ω/mm, 44 × 103 Ω/mm and 6.2 × 103 Ω/mm, respectively, while their capacitive sensitivities were -19.0 × 10-2 pF/mm, -16.0 × 10-2 pF/mm, -16.4 × 10-2 pF/mm and -1.8 × 10-2 pF/mm. If needed for practical application, the sensors can be built in to the Wheatstone bridge, which can also increase the sensitivity of the measurement. Moreover, the sensor's materials are low cost, while the fabrication technique is easy and ecologically friendly. The sensor can also be used for demonstrative purposes in school and college laboratories.

4.
Polymers (Basel) ; 15(12)2023 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-37376337

RESUMO

Polymeric rubber and organic semiconductor H2Pc-CNT-composite-based surface- and sandwich-type shockproof deformable infrared radiation (IR) sensors were fabricated using a rubbing-in technique. CNT and CNT-H2Pc (30:70 wt.%) composite layers were deposited on a polymeric rubber substrate as electrodes and active layers, respectively. Under the effect of IR irradiation (0 to 3700 W/m2), the resistance and the impedance of the surface-type sensors decreased up to 1.49 and 1.36 times, respectively. In the same conditions, the resistance and the impedance of the sandwich-type sensors decreased up to 1.46 and 1.35 times, respectively. The temperature coefficients of resistance (TCR) of the surface- and sandwich-type sensors are 1.2 and 1.1, respectively. The novel ratio of the H2Pc-CNT composite ingredients and comparably high value of the TCR make the devices attractive for bolometric applications meant to measure the intensity of infrared radiation. Moreover, given their easy fabrication and low-cost materials, the fabricated devices have great potential for commercialization.

5.
Nanoscale Horiz ; 8(6): 759-766, 2023 May 30.
Artigo em Inglês | MEDLINE | ID: mdl-37128758

RESUMO

Wearable displays or head-mounted displays (HMDs) have the ability to create a virtual image in the field of view of one or both eyes. Such displays constitute the main platform for numerous virtual reality (VR)- and augmented reality (AR)-based applications. Meta-holographic displays integrated with AR technology have potential applications in the advertising, media, and healthcare sectors. In the previous decade, dielectric metasurfaces emerged as a suitable choice for designing compact devices for highly efficient displays. However, the small conversion efficiency, narrow bandwidth, and costly fabrication procedures limit the device's functionalities. Here, we proposed a spin-isolated dielectric multi-functional metasurface operating at broadband optical wavelengths with high transmission efficiency in the ultraviolet (UV) and visible (Vis) regimes. The proposed metasurface comprised silicon nitride (Si3N4)-based meta-atoms with high bandgap, i.e., ∼ 5.9 eV, and encoded two holographic phase profiles. Previously, the multiple pieces of holographic information incorporated in the metasurfaces using interleaved and layer stacking techniques resulted in noisy and low-efficiency outputs. A single planar metasurface integrated with a liquid crystal was demonstrated numerically and experimentally in the current work to validate the spin-isolated dynamic UV-Vis holographic information at broadband wavelengths. In our opinion, the proposed metasurface can have promising applications in healthcare, optical security encryption, anti-counterfeiting, and UV-Vis nanophotonics.

6.
Gels ; 8(4)2022 Apr 07.
Artigo em Inglês | MEDLINE | ID: mdl-35448127

RESUMO

Here, we present the design, fabrication and characterization of shockproof rubber-jelly (NiPc-CNT-oil) composite-based resistors. To fabricate the resistors, gels of CNT and NiPc with edible oil were prepared and deposited on a flexible rubber substrate using rubbing-in technique. The devices' resistance and impedance were investigated under the effect of pressure, displacement, humidity, temperature and mechanical vibrations. The resistance and the impedance decreased, on average, by 1.08 times under the effect of pressure (up to 850 gf/cm2) and by 1.04 times under the effect of displacement (up to 50 µm). Accordingly, upon increasing the humidity from 60% to 90% RH, the resistance and impedance decreased by up to 1.04 times, while upon increasing the temperature from 25 °C to 43 °C, the resistance and impedances also decreased by up to 1.05 times. Moreover, under the effect of vibration, a decrease in resistance and impedance, by up to 1.03 times, was observed. The investigated samples can potentially be used as prototypes for the development of shockproof jelly electronic-based devices in particular resistors. The technological achievement in the fabrication of these devices is the use of edible organic oil, which allows for the fabrication of uniform jelly films of organic materials that cannot be realized simply by mixing "dry" ingredients. Especially, we highlight that edible organic oil is environmentally friendly, unlike some other inorganic oils that are used in practice.

7.
Int J Biol Macromol ; 206: 917-926, 2022 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-35304202

RESUMO

This study reports the synthesis of bacterial cellulose (BC) hydrogel sheets and their utilization as a support for silver­nickel oxide nanocomposites (Ag/NiO). A two-step facile hydrothermal method was employed for the preparation of Ag/NiO, followed by impregnation into BC hydrogel sheets. A 20% Ag/NiO composition was revealed by dry weight analysis. The stability of nanocomposites-Hydrogel was confirmed by Ag+ and Ni2+ ion release study. The catalytic activity of the BC-Ag/NiO was evaluated against chemical reduction of congo red, methyl orange and methylene blue. The reduction reaction followed pseudo first order kinetics and kapp values of 0.1147 min-1, 0.1323 min-1 and 0.12989 min-1 were obtained for CR, MO, and MB dyes, respectively. The BC-Ag/NiO catalyst could be easily recovered and re-used in another reaction without centrifugation. The synthesized nanocomposites hydrogel was also tested for its antibacterial activity against Gram-negative bacteria, Escherichia coli (E.coli) and Gram-positive bacteria, Staphylococcus aureus (S.aureus).


Assuntos
Nanopartículas Metálicas , Nanocompostos , Antibacterianos/química , Antibacterianos/farmacologia , Bactérias , Celulose/química , Escherichia coli , Hidrogéis/farmacologia , Nanopartículas Metálicas/química , Nanocompostos/química , Prata/química , Prata/farmacologia , Staphylococcus aureus
8.
Gels ; 8(2)2022 Jan 24.
Artigo em Inglês | MEDLINE | ID: mdl-35200455

RESUMO

Here we present the fabrication of graphene and jelly (superabsorbent polymer) electrolyte composite-based shockproof flexible electrochemical sensors (Al/Gr-Jelly/Cu) and their properties under the effect of humidity and temperature. A layer of graphene mixed in jelly electrolyte was drop-casted onto porous rubber substrates between preliminary fixed aluminum (Al) and copper (Cu) electrodes followed by rubbing-in. It was observed that the graphene and jelly mixture was mechanically soft and flexible, similar to jelly. Electrically, this mixture (graphene and jelly) behaved as a flexible electrolyte. It was observed that under the effect of humidity ranging from 47 to 98%, the impedances of the sensors decreased by 2.0 times on average. Under the effect of temperatures ranging from 21 to 41 °C the impedances decreased by 2.4 times. The average temperature coefficient of impedances was equal to -0.03 °C-1. The electrochemical voltage generated by the flexible jelly electrolyte sensors was also investigated. It was found that the initial open-circuit voltages were equal to 201 mV and increased slightly, by 5-10% under the effect of humidity and temperature as well. The short-circuit currents under the effect of humidity and temperature increased by 2-3 times. The Al/Gr-Jelly/Cu electrochemical sensors may be used as prototypes for the development of the jelly electronic-based devices.

9.
Gels ; 8(2)2022 Jan 28.
Artigo em Inglês | MEDLINE | ID: mdl-35200464

RESUMO

The flexible and shockproof rubber-based Al/OD-Gel/Cu electrochemical cell was designed, fabricated, and investigated for the detection of IR and UV irradiations. For this purpose, the transparent gel-orange dye composite was deposited on the porous rubber substrate between aluminum and copper electrodes. It was observed that the gel-orange dye composite was mechanically like a gel: soft and flexible. Electrically, this composite (gel-orange dye) forms a flexible electrolyte. It was found that the impedance of the samples under the effect of infrared irradiation decreased by 2.02 to 2.19 times on changing frequency from 100 Hz to 200 kHz. Accordingly, under the effect of ultraviolet irradiation, the impedance of the samples decreased by 1.23 to 1.45 times on increasing frequency from 100 Hz to 200 kHz. Under the effect of infrared irradiation up to 4000 W/m2, the cell's open-circuit voltage increased by 1.59 times. The cell's open-circuit voltage also increased by 1.06 times under the effect of ultraviolet irradiation up to 200 uW/cm2. The mechanism of the absorption of the infrared and ultraviolet irradiations by the OD-Gel composite has been discussed in detail. The fabricated flexible rubber substrate-based Al/OD-Gel/Cu electrochemical cells can be used as a prototype for the development of gel electronics-based devices.

10.
Gels ; 8(2)2022 Jan 30.
Artigo em Inglês | MEDLINE | ID: mdl-35200469

RESUMO

The current study was aimed at developing BC-Cactus (BCC) composite hydrogels with impressive mechanical features for their potential applications in medical and environmental sectors. BCC composites hydrogels were developed through cactus gel coating on a never dried BC matrix. The FE-SEM micrographs confirmed the saturation of BC fibrils with cactus gel. Additionally, the presence of various functional groups and alteration in crystalline behavior was confirmed through FTIR and XRD analysis. Mechanical testing illustrated a three-times increase in the strain failure and an increase of 1.6 times in the tensile strength of BCC composite. Absorption capabilities of BCC were much higher than pure BC and it retained water for a longer period of time. Additionally, the rewetting and absorption potentials of composites were also higher than pure BC. The composite efficiently adsorbed Pb, Zn, Cu, and Co metals. Biocompatibility studies against human HaCat cell line indicated much better cell adhesion and proliferation of BCC compared to BC. These findings advocate that the BCC composite could find applications in medical, pharmaceutical and environmental fields.

11.
Int J Biol Macromol ; 194: 377-383, 2022 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-34800523

RESUMO

Nanocomposites of chitosan and cerium oxide­cadmium oxide (CeO2-CdO) nanopowder were developed to fabricate impedimetric humidity sensors. The low temperature-stirring was used to synthesize CeO2-CdO nanopowder. Average particle size of synthesized nanopowder was 100 ± 20 nm. Various composition of chitosan-CeO2-CdO nanocomposites were developed using echo-friendly (mechanical mixing) technique. Pellets of 13.0 mm diameter and 1.0 ± 0.1 mm thickness were prepared using hydraulic press under the pressure of 375 MPa. Silver paste was used to deposit the electrodes; the length of each electrode was 12.0 mm and the gap between two electrodes was 2.0 ± 0.5 mm. The mechanism of sensing is based on impedimetric change in response to humidity variation. Fabricated sensors showed high sensitivities ranging from -930.0 kΩ/%RH to -2091.1 kΩ/%RH. Response and recovery times are up to 1 s, while the humidity sensing range is 5 to 95%RH. The fabricated sensors are very attractive to use in several devices for environmental monitoring and biomedical applications.


Assuntos
Compostos de Cádmio/química , Cério/química , Quitosana/química , Umidade , Nanocompostos/química , Óxidos/química , Fenômenos Químicos , Técnicas de Química Sintética , Nanocompostos/ultraestrutura , Análise Espectral
12.
Carbohydr Polym ; 148: 153-60, 2016 09 05.
Artigo em Inglês | MEDLINE | ID: mdl-27185126

RESUMO

A new kind of titanium oxide dispersed in chitosan (TiO2/CS) nanocomposite adsorbent was prepared and adhered to high surface area substrate, cellulose microfibers mat (CMM). CS-CMM and TiO2/CS-CMM were used for the thymol violet (TV) dye removal from wastewater. Characterization of materials was carried out by X-ray diffraction, scanning electron microscope and energy dispersive X-ray spectroscopy. The adsorption properties of both the CS-CMM and TiO2/CS-CMM were investigated as a function of adsorbent dosage, solution pH, and contact time. It was revealed that the composites pretreated in the solution with higher pH value exhibited larger adsorption capacities. Kinetic studies showed that the composites could adsorb TV dye rapidly and reached the equilibrium in 90min. The adsorption process followed pseudo-second order kinetics and involved particle diffusion mechanism. The calculated maximum adsorption capacities of CS-CMM and TiO2/CS-CMM were 84.32 and 97.51mgg(-1), respectively. Compare to CS, the TiO2/CS nanocomposite coated CMM showed higher antibacterial characteristics as tested against Escherichia coli.


Assuntos
Antibacterianos/farmacologia , Quitosana/farmacologia , Corantes/metabolismo , Escherichia coli/efeitos dos fármacos , Nanocompostos/química , Titânio/farmacologia , Adsorção , Quitosana/química , Quitosana/metabolismo , Concentração de Íons de Hidrogênio , Cinética , Titânio/química , Titânio/metabolismo
13.
PLoS One ; 9(4): e95287, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24748375

RESUMO

This work presents the fabrication and investigation of thermoelectric cells based on composite of carbon nanotubes (CNT) and silicone adhesive. The composite contains CNT and silicon adhesive 1∶1 by weight. The current-voltage characteristics and dependences of voltage, current and Seebeck coefficient on the temperature gradient of cell were studied. It was observed that with increase in temperature gradient the open circuit voltage, short circuit current and the Seebeck coefficient of the cells increase. Approximately 7 times increase in temperature gradient increases the open circuit voltage and short circuit current up to 40 and 5 times, respectively. The simulation of experimental results is also carried out; the simulated results are well matched with experimental results.


Assuntos
Adesivos , Silicones , Temperatura , Microscopia Eletrônica de Varredura , Nanotubos de Carbono
14.
Talanta ; 120: 443-9, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24468394

RESUMO

Smart and professional humidity and temperature sensors have been fabricated by utilizing copper oxide-Si-adhesive composite and pure copper oxide nanosheets. Copper oxide nanosheets are synthesized by low temperature stirring method and characterized by field emission scanning electron microscopy, which reveals that synthesized product is composed of randomly oriented nanosheets, which are grown in high density with an average thickness of~80±10 nm. X-ray diffraction confirms that the grown nanosheets consist of well crystalline monoclinic CuO. X-ray photoelectron spectroscopy and Fourier transform infrared (FTIR) spectroscopy also confirm that the synthesized nanomaterial is pure CuO without any impurity. The fabricated sensors exhibit good temperature sensitivity of -4.0%/°C and -5.2%/°C and humidity sensitivity of -2.9%/%RH and -4.88%/%RH, respectively for copper oxide-Si-adhesive composite and pure copper oxide nanosheets. The average initial resistance of the sensors is equal to 250 MΩ and 55 MΩ for the composite and pure copper oxide based sensors, respectively.


Assuntos
Adesivos/química , Cobre/química , Nanocompostos/química , Silício/química , Umidade , Espectroscopia Fotoeletrônica , Temperatura , Difração de Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...