Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 23
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Int J Mol Sci ; 24(21)2023 Oct 28.
Artigo em Inglês | MEDLINE | ID: mdl-37958673

RESUMO

The endocannabinoid system (ECS) is a new target for the development of retinal disease therapeutics, whose pathophysiology involves neurodegeneration and neuroinflammation. The endocannabinoid 2-arachidonoylglycerol (2-AG) affects neurons and microglia by activating CB1/CB2 cannabinoid receptors (Rs). The aim of this study was to investigate the effects of 2-AG on the CB1R expression/downregulation and retinal neurons/reactive microglia, when administered repeatedly (4 d), in three different paradigms. These involved the 2-AG exogenous administration (a) intraperitoneally (i.p.) and (b) topically and (c) by enhancing the 2-AG endogenous levels via the inhibition (AM11920, i.p.) of its metabolic enzymes (MAGL/ABHD6). Sprague Dawley rats were treated as mentioned above in the presence or absence of CB1/CB2R antagonists and the excitatory amino acid, α-amino-3-hydroxy-5-methyl-4-isoxazolepropionic acid (AMPA). Immunohistochemistry, Western blot and a 2-AG level analyses were performed. The 2-AG repeated treatment (i.p.) induced the CB1R downregulation, abolishing its neuroprotective actions. However, 2-AG attenuated the AMPA-induced activation of microglia via the CB2R, as concurred by the AM630 antagonist effect. Topically administered 2-AG was efficacious as a neuroprotectant/antiapoptotic and anti-inflammatory agent. AM11920 increased the 2-AG levels providing neuroprotection against excitotoxicity and reduced microglial activation without affecting the CB1R expression. Our findings show that 2-AG, in the three paradigms studied, displays differential pharmacological profiles in terms of the downregulation of the CB1R and neuroprotection. All treatments, however, attenuated the activation of microglia via the CB2R activation, supporting the anti-inflammatory role of 2-AG in the retina.


Assuntos
Endocanabinoides , Microglia , Ratos , Animais , Endocanabinoides/farmacologia , Endocanabinoides/metabolismo , Receptores de Canabinoides/metabolismo , Microglia/metabolismo , Ratos Sprague-Dawley , Ácido alfa-Amino-3-hidroxi-5-metil-4-isoxazol Propiônico/metabolismo , Retina/metabolismo , Receptor CB1 de Canabinoide/metabolismo , Receptor CB2 de Canabinoide/metabolismo
2.
Microorganisms ; 11(6)2023 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-37375094

RESUMO

Pseudomonas sp. phDV1 is a polyhydroxyalkanoate (PHA) producer. The presence of the endogenous PHA depolymerase (phaZ) responsible for the degradation of the intracellular PHA is one of the main shortages in the bacterial production of PHA. Further, the production of PHA can be affected by the regulatory protein phaR, which is important in accumulating different PHA-associated proteins. PHA depolymerase phaZ and phaR knockout mutants of Pseudomonas sp. phDV1 were successfully constructed. We investigate the PHA production from 4.25 mM phenol and grape pomace of the mutants and the wild type. The production was screened by fluorescence microscopy, and the PHA production was quantified by HPLC chromatography. The PHA is composed of Polydroxybutyrate (PHB), as confirmed by 1H-nuclear magnetic resonance analysis. The wildtype strain produces approximately 280 µg PHB after 48 h in grape pomace, while the phaZ knockout mutant produces 310 µg PHB after 72 h in the presence of phenol per gram of cells, respectively. The ability of the phaZ mutant to synthesize high levels of PHB in the presence of monocyclic aromatic compounds may open the possibility of reducing the costs of industrial PHB production.

3.
Analyst ; 141(13): 4170-80, 2016 Jun 20.
Artigo em Inglês | MEDLINE | ID: mdl-27170233

RESUMO

In this work we report on the optical properties of specific synthetic carbon nano-dots (CDs) and their suitability for the development of optical biosensors. We examine the photoluminescence behavior of these CDs under different conditions, in their native form, as well as when conjugated to the catalytic protein glucose oxidase (GOx) for the construction of optical glucose biosensors. The effect of pH and hydrogen peroxide on the observed spectra is examined as the basis for the biosensor development. The CDs examined here have inherent surface amino functional groups which allow for easy conjugation to biomolecules via EDC-NHS, providing a well defined platform for biosensing applications. We conclude that the well controlled, stable, and highly efficient fluorescence behavior of the CDs in solution or in conjugate, provides the grounds for this class of materials to be used in a variety of arrangements for the development of optical and optoelectrochemical detection systems.


Assuntos
Técnicas Biossensoriais , Carbono , Nanopartículas , Fluorescência , Glucose , Glucose Oxidase , Peróxido de Hidrogênio
4.
Int J Nanomedicine ; 11: 1-12, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26730187

RESUMO

Dendrimers are large polymeric structures with nanosize dimensions (1-10 nm) and unique physicochemical properties. The major advantage of dendrimers compared with linear polymers is their spherical-shaped structure. During synthesis, the size and shape of the dendrimer can be customized and controlled, so the finished macromolecule will have a specific "architecture" and terminal groups. These characteristics will determine its suitability for drug delivery, diagnostic imaging, and as a genetic material carrier. This review will focus initially on the unique properties of dendrimers and their use in biomedical applications, as antibacterial, antitumor, and diagnostic agents. Subsequently, emphasis will be given to their use in drug delivery for ocular diseases.


Assuntos
Dendrímeros/administração & dosagem , Dendrímeros/farmacologia , Sistemas de Liberação de Medicamentos/métodos , Nanomedicina/métodos , Administração Oral , Antibacterianos/administração & dosagem , Antibacterianos/química , Antineoplásicos/administração & dosagem , Antineoplásicos/química , Dendrímeros/química , Usos Diagnósticos de Compostos Químicos , Interações Medicamentosas , Oftalmopatias/tratamento farmacológico , Técnicas de Transferência de Genes , Humanos , Polímeros/química
5.
Bioelectrochemistry ; 86: 72-7, 2012 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-22421347

RESUMO

We report on the construction of an amperometric biosensor based on the immobilization of the enzyme acetylcholinesterase (AChE) onto gold nanoparticles (Au NPs). The active enzyme is covalently bound directly onto the surface of the Au NPs via a thiol bond. This immobilization provides increased stability and high electron-transfer between the colloidal Au NPs, the catalyst and the transducer surface. To further increase the biosensor stability by protecting the enzyme from denaturation and protease attack, a layer of biosilica was grown around the Au NP enzyme nanocomposite. All steps, i.e., the conjugation of the enzyme to the gold nanoparticles and the encapsulation into biosilica, are monitored and confirmed by ATR-FT-IR spectroscopy. The stabilizing effect of the entrapment was evaluated amperometrically, while the operation of the biosensor was monitored over a period of 4 months. The initial sensitivity of the biosensor was calculated to be 27.58 nA mM(-1) with a linear response to the concentration of the substrate in the range from 0.04 to 0.4 mM. It is thus shown that the biosilica nanocomposites doped with Au NPs-AChE conjugates create a system that provides both signal mediation and significant enzyme stabilization over the existing AChE biosensor. The biosensor had retained all its activity at the end of the 4 months, compared with the normal AChE biosensor whose activity reached 50% after only 42 days of operation.


Assuntos
Acetilcolinesterase/química , Técnicas Biossensoriais/métodos , Nanocompostos/química , Tiocolina/análise , Técnicas Biossensoriais/instrumentação , Técnicas Eletroquímicas/métodos , Enzimas Imobilizadas/química , Ouro/química , Modelos Lineares , Nanopartículas Metálicas/química , Nanocompostos/ultraestrutura , Sensibilidade e Especificidade , Dióxido de Silício/química , Espectroscopia de Infravermelho com Transformada de Fourier , Fatores de Tempo
6.
Anal Chem ; 83(14): 5749-53, 2011 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-21662988

RESUMO

There is currently a need for a reliable solid-state reference electrode, especially in applications such as autonomous sensing or long-term environmental monitoring. We present here for the first time a novel solid-state nanofiber junction reference electrode (NFJRE) incorporating a junction consisting of poly(methyl methacrylate) and carbon graphene stacked nanofibers. The NFJRE operates by using the membrane polymer junction, which has a very high glass transition temperature (T(g)) and small diffusion coefficient, to control the diffusion of ions, and the carbon nanofibers lower the junction resistance and act as ion-to-electron transducers. The fabrication of the NFJRE is detailed, and its behavior is characterized in terms of its impedance, stability, and behavior in comparison with traditional reference electrodes. The NFJRE showed a response of <5-13 mV toward a variety of electrolyte solutions from 10(-5) to 10(-2) M, <10 mV over a pH range of 2-12, and excellent behavior when used with voltammetric methods.

7.
Anal Bioanal Chem ; 398(7-8): 3015-21, 2010 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-20936265

RESUMO

CdSe/ZnS core/shell quantum dots (QDs) are functionalized with mercaptoundecanoic acid (MUA) and subsequently covered with poly-L-lysine (PLL) as the template for the formation of the silica outer shell. This nanocomposite is used as a transduction and stabilization system for optical biosensor development. The covalent immobilization of the enzyme acetylcholinesterase from Drosophila melanogaster (AChE) during the formation of the biomimetically synthesized silica is used here as a model, relatively unstable enzyme, as a proof of principle. The enzyme is successfully immobilized onto the QDs and then stabilized by the PLL capping and the subsequent formation of the outer nanoporous silica thin shell, giving rise to the QD/AChE/PLL/silica biosensor. It is shown that the poly-L-lysine templated silica outer shell does not modify the optical properties of the quantum dots, while it protects the enzyme from unfolding and denaturation. The small pores of the silica shell allow for the free diffusion of the analyte to the active center of the enzyme, while it does not allow for the proteases to reach the enzyme. The response of the QD/AChE/PLL/silica nano-biosensor to its substrate, acetylcholine chloride, is evaluated by monitoring the changes in the QDs' photoluminescence which are related to the changes in pH. These pH changes of the surrounding environment of the QDs are induced by the enzymatic reaction, and are associated with the analyte concentration in the solution. The biodetection system proposed is shown to be stable with a storage lifetime of more than 2 months. The data presented provides the grounds for the application of this nanostructured biosensor for the detection of AChE inhibitors.


Assuntos
Acetilcolinesterase/química , Técnicas Biossensoriais/métodos , Compostos de Cádmio/química , Polilisina/química , Pontos Quânticos , Compostos de Selênio/química , Dióxido de Silício/química , Sulfetos/química , Compostos de Zinco/química , Acetilcolinesterase/metabolismo , Medições Luminescentes/métodos , Microscopia Eletrônica de Transmissão
8.
Biosens Bioelectron ; 25(11): 2408-13, 2010 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-20447820

RESUMO

We demonstrate fabrication of microbiosensors utilizing a simple, rapid biomimetic silicification method catalyzed by poly-L-lysine at ambient temperature to provide a mild and efficient method for entrapment of the enzymes required for a range of analytes. To obtain a robust poly-L-lysine layer for precipitating silica onto the Pt surface, a Pt microelectrode was first functionalized with abundant carboxyl groups by electrochemical deposition of poly(pyrrole-1-propanoic acid). By means of zero length cross-linking reagents N-(3-dimethylaminopropyl)-N'-ethylcarbodiimide hydrochloride (EDC) and N-hydroxysulfosuccinimide sodium salt (NHSS), poly-L-lysine was covalently immobilized onto microelectrode surface. Under mild chemical conditions, three enzymes including adenosine deaminase (AD, EC 3.5.4.4), nucleoside phosphorylase (NP, EC 2.4.2.1) and xanthine oxidase (XO, EC 1.1.3.22) could then be simultaneously entrapped into a continuous silicate layer formed on top of Pt microelectrode from a mixture of enzymes and hydrolyzed silanes in Tris buffer (0.1M, pH 7.2) via the catalytic action of the attached poly-L-lysine. The fabricated adenosine biosensors exhibited good analytical performance with a sensitivity of 153.0+/-2.4 microA mM(-1)cm(-2) (n=4, R.S.D.=2.1%), a lower detection limit of 40 nM and a favourable response time (estimated as 10-90% response rise time) of 25+/-2s (n=4). The good selectivity of the adenosine microbiosensor against coexisting interfering substances such as ascorbic acid, urate and 5-HT was achieved through formation of a screening barrier from electrodeposited poly(diaminobenzene) following the biomimetic deposition process. We found that our methods were adaptable for other enzymes and analytes allowing fabrication of l-glutamate and lactate biosensors.


Assuntos
Adenosina/análise , Materiais Biomiméticos , Técnicas Biossensoriais/instrumentação , Condutometria/instrumentação , Complexos Multienzimáticos/química , Dióxido de Silício/química , Adenosina/química , Desenho de Equipamento , Análise de Falha de Equipamento , Miniaturização , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
9.
IEEE Trans Inf Technol Biomed ; 14(3): 622-33, 2010 May.
Artigo em Inglês | MEDLINE | ID: mdl-20123578

RESUMO

SMARTDIAB is a platform designed to support the monitoring, management, and treatment of patients with type 1 diabetes mellitus (T1DM), by combining state-of-the-art approaches in the fields of database (DB) technologies, communications, simulation algorithms, and data mining. SMARTDIAB consists mainly of two units: 1) the patient unit (PU); and 2) the patient management unit (PMU), which communicate with each other for data exchange. The PMU can be accessed by the PU through the internet using devices, such as PCs/laptops with direct internet access or mobile phones via a Wi-Fi/General Packet Radio Service access network. The PU consists of an insulin pump for subcutaneous insulin infusion to the patient and a continuous glucose measurement system. The aforementioned devices running a user-friendly application gather patient's related information and transmit it to the PMU. The PMU consists of a diabetes data management system (DDMS), a decision support system (DSS) that provides risk assessment for long-term diabetes complications, and an insulin infusion advisory system (IIAS), which reside on a Web server. The DDMS can be accessed from both medical personnel and patients, with appropriate security access rights and front-end interfaces. The DDMS, apart from being used for data storage/retrieval, provides also advanced tools for the intelligent processing of the patient's data, supporting the physician in decision making, regarding the patient's treatment. The IIAS is used to close the loop between the insulin pump and the continuous glucose monitoring system, by providing the pump with the appropriate insulin infusion rate in order to keep the patient's glucose levels within predefined limits. The pilot version of the SMARTDIAB has already been implemented, while the platform's evaluation in clinical environment is being in progress.


Assuntos
Redes de Comunicação de Computadores , Diabetes Mellitus Tipo 1/terapia , Gerenciamento Clínico , Aplicações da Informática Médica , Monitorização Ambulatorial/métodos , Glicemia/análise , Telefone Celular , Mineração de Dados/métodos , Humanos , Infusões Subcutâneas , Sistemas de Infusão de Insulina , Dinâmica não Linear , Análise Espectral Raman , Telemetria/métodos , Interface Usuário-Computador
10.
Anal Bioanal Chem ; 396(1): 229-40, 2010 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-19714321

RESUMO

Quantum dots (QDs) are inorganic semiconductor nanocrystals that have unique optoelectronic properties responsible for bringing together multidisciplinary research to impel their potential bioanalytical applications. In recent years, the many remarkable optical properties of QDs have been combined with the ability to make them increasingly biocompatible and specific to the target. With this great development, QDs hold particular promise as the next generation of fluorescent probes. This review describes the developments in functionalizing QDs making use of different bioconjugation and capping approaches. The progress offered by QDs is evidenced by examples on QD-based biosensing, biolabeling, and delivery of therapeutic agents. In the near future, QD technology still faces some challenges towards the envisioned broad bioanalytical purposes.


Assuntos
Transferência Ressonante de Energia de Fluorescência/métodos , Corantes Fluorescentes/química , Ácidos Nucleicos/análise , Pontos Quânticos , Materiais Biocompatíveis/química , Ácidos Nucleicos/química
11.
Anal Bioanal Chem ; 395(2): 429-35, 2009 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-19644678

RESUMO

The properties of native and oxidised graphene layered carbon nanofibres are compared, and their utilisation in enzyme biosensor systems using different immobilisation methods are evaluated. The efficient oxidation of carbon nanofibres with concentrated H(2)SO(4)/HNO(3) is confirmed by Raman spectroscopy while the introduction of carboxylic acid groups on the surface of the fibres by titration studies. The oxidised fibres show enhanced oxidation efficiency to hydrogen peroxide, while at the same time they exhibit a more efficient and selective interaction with enzymes. The analytical characteristics of biosensor systems based on the adsorption or covalent immobilisation of the enzyme glucose oxidase on carbon nanofibres are compared. The study reveals that carbon nanofibres are excellent substrates for enzyme immobilisation allowing the development of highly stable biosensor systems.


Assuntos
Técnicas Biossensoriais/métodos , Carbono/química , Enzimas Imobilizadas/química , Proteínas Fúngicas/química , Glucose Oxidase/química , Nanoestruturas/química , Adsorção , Aspergillus niger/enzimologia , Eletroquímica/métodos , Estabilidade Enzimática , Enzimas Imobilizadas/metabolismo , Proteínas Fúngicas/metabolismo , Glucose Oxidase/metabolismo , Modelos Moleculares , Nanoestruturas/ultraestrutura , Oxirredução , Conformação Proteica , Análise Espectral Raman , Propriedades de Superfície , Titulometria
12.
Sensors (Basel) ; 9(9): 7266-86, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-22423206

RESUMO

Quantum dots are nanometre-scale semiconductor crystals with unique optical properties that are advantageous for the development of novel chemical sensors and biosensors. The surface chemistry of luminescent quantum dots has encouraged the development of multiple probes based on linked recognition molecules such as peptides, nucleic acids or small-molecule ligands. This review overviews the design of sensitive and selective nanoprobes, ranging from the type of target molecules to the optical transduction scheme. Representative examples of quantum dot-based optical sensors from this fast-moving field have been selected and are discussed towards the most promising directions for future research.

13.
Anal Chem ; 80(15): 5970-5, 2008 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-18593196

RESUMO

Biomimetically synthesized silica and conductive activated carbon nanofibers (CNFs) are used in a synergistic manner for the development of a novel electrochemical biosensor system. Poly(L-lysine) templated silica grows and encapsulates the CNF-immobilized enzyme generating a highly stabilizing nanostructured environment for the underlying protein. Concurrently, CNFs provide both the required surface area for the high-capacity enzyme immobilization required in biosensors as well as direct electron transfer to the inner platinum transducer. As a result, this silica/nanofiber superstructure is an ideal architecture for the development of electrochemical biosensor systems that can withstand exposure to extreme operational conditions, such as high temperatures or the presence of proteases. Acetylcholine esterase is used as the model catalyst and with the aid of spectroscopic data it is shown that the observed high operational stability of the biosensor is due to the direct interaction of the protein with the silica backbone, as well as due to the nanostructured enzyme confinement.


Assuntos
Técnicas Biossensoriais/métodos , Carbono , Enzimas Imobilizadas , Nanofios , Dióxido de Silício , Acetilcolinesterase , Biomimética , Eletroquímica
14.
Analyst ; 133(8): 1072-5, 2008 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-18645649

RESUMO

In this work, C(60) fullerene is used as an electrochemical mediator for the development of an all-solid-state ISE. The unique electrochemical characteristics of the fullerenes allow for the facile ion-to-electron transduction across the ionically active polymeric ion-selective membrane and the electrochemically active glassy carbon transducer. The interfacial ion-to-electron charge transfer was investigated by Electrochemical Impedance Spectroscopy. The study of the analytical characteristics of a model potassium-selective electrode, together with the EIS studies, reveals that, indeed, the interfacial C(60) electrochemically active layer facilitates the ion-to-electron transduction, providing a stable and reversible solid-state ISE system. This finding is a significant contribution to the efforts aiming at overcoming one of the most significant drawbacks of the solid-state ISEs, that is the potential drift observed during continuous measurements, and could lead to the development of both cation- and anion-sensitive systems.

15.
Anal Chim Acta ; 615(1): 1-9, 2008 May 12.
Artigo em Inglês | MEDLINE | ID: mdl-18440357

RESUMO

The aim of this manuscript is to provide a condensed overview of the contribution of certain relatively new semiconductor substrates in the development of chemical and biochemical field effect transistors. The silicon era is initially reviewed providing the background onto which the deployment of the new semiconductor materials for the development of bio-chem-FETs is based on. Subsequently emphasis is given to the selective interaction of novel semiconductor surfaces, including doped conductive diamond, gallium nitride, and indium nitride, with the analyte, and how this interaction can be properly transduced using semiconductor technology. The main advantages and drawbacks of these materials, as well as their future prospects for their applications in the sensor area are also described.


Assuntos
Técnicas Biossensoriais , Diamante/química , Gálio/química , Índio/química , Dióxido de Silício/química , Técnicas Biossensoriais/instrumentação , Técnicas Biossensoriais/tendências , Eletrodos , Semicondutores/tendências , Propriedades de Superfície
16.
Biosens Bioelectron ; 22(12): 2848-53, 2007 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-17223333

RESUMO

Monitoring of the organophosphorus pesticides dichlorvos and paraoxon at very low levels has been achieved with liposome-based nano-biosensors. The enzyme acetylcholinesterase was effectively stabilized within the internal nano-environment of the liposomes. Within the liposomes, the pH sensitive fluorescent indicator pyranine was also immobilized for the optical transduction of the enzymatic activity. Increasing amounts of pesticides lead to the decrease of the enzymatic activity for the hydrolysis of the acetylcholine and thus to a decrease in the fluorescent signal of the pH indicator. The decrease of the liposome biosensors signal is relative to the concentration of dichlorvos and paraoxon down to 10(-10)M levels. This biosensor system has been applied successfully to the detection of total toxicity in drinking water samples. Also a colorimetric screening device for pesticide analysis has been evaluated.


Assuntos
Técnicas Biossensoriais/métodos , Diclorvós/análise , Nanotecnologia/métodos , Paraoxon/análise , Praguicidas/análise , Técnicas Biossensoriais/instrumentação , Corantes Fluorescentes , Lipossomos , Nanotecnologia/instrumentação , Poluentes Químicos da Água/análise
17.
Biosens Bioelectron ; 22(11): 2650-5, 2007 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-17142036

RESUMO

Nanoporous materials with different pore sizes are evaluated as immobilization and stabilization matrices of proteins for the development of highly stable biosensors. It has been proven experimentally that confinement of proteins in cages with a diameter that is 2-6 times larger than their size increases considerably the stability of the biomolecules, as has been shown earlier by theoretical calculations. Porous silica beads with pore sizes of 10nm were utilized for the immobilization of the enzymes HRP and GOx with diameters in the order of 5 and 7 nm, respectively. The sensitivity of the corresponding biosensor systems was monitored for 70 h under continuous operation conditions (+600 mV) and it was found that the stabilization factor of GOx is 1.7 times higher compared to HRP. Also the stabilization efficiency of enzymes against leaching and inactivation in porous polymer beads with pore diameters of 10 and 30 nm was examined. The leaching rate of the enzyme AChE from the 30 nm polymer beads was found to be 1.1 times higher than that from the 10nm beads. At the same time the remaining activity of GOx biosensors after 5 days of continuous operation conditions (+600 mV) was found to be 2.1 times higher when the enzyme had been immobilized in the 10nm beads compared to the 30 nm beads. It is thus evident that the matching between the pore size of nanoporous materials and the molecular size of enzymes is essential for the development of biosensors with extended shelf and operational lifetimes.


Assuntos
Técnicas Biossensoriais/instrumentação , Eletroquímica/instrumentação , Glucose Oxidase/química , Glucose/análise , Peroxidase do Rábano Silvestre/química , Peróxido de Hidrogênio/análise , Nanoestruturas/química , Técnicas Biossensoriais/métodos , Eletroquímica/métodos , Estabilidade Enzimática , Enzimas Imobilizadas/química , Microeletrodos , Nanoestruturas/ultraestrutura , Ligação Proteica , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
18.
Anal Chem ; 78(15): 5538-42, 2006 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-16878893

RESUMO

The use of highly activated carbon nanofibers for the design of catalytic electrochemical biosensors is demonstrated. The direct immobilization of enzymes onto the surface of carbon nanofibers is shown to be a highly efficient method for the development of a new class of very sensitive, stable, and reproducible electrochemical biosensors. These results establish the fact that the carbon nanofiber is the best matrix so far described for the development of biosensors, far superior to carbon nanotubes or graphite powder.


Assuntos
Técnicas Biossensoriais/métodos , Enzimas Imobilizadas/química , Glucose Oxidase/química , Glucose/análise , Grafite/química , Nanotubos de Carbono/química , Eletroquímica , Concentração de Íons de Hidrogênio , Tamanho da Partícula , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Propriedades de Superfície
19.
Biosens Bioelectron ; 21(2): 384-8, 2005 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-16023967

RESUMO

The encapsulation of enzymes in microenvironments and especially in liposomes, has proven to greatly improve enzyme stabilization against unfolding, denaturation and dilution effects. Combining this stabilization effect, with the fact that liposomes are optically translucent, we have designed nano-sized spherical biosensors. In this work liposome-based biosensors are prepared by encapsulating the enzyme acetylcholinesterase (AChE) in L-a phosphatidylcholine liposomes resulting in spherical optical biosensors with an average diameter of 300+/-4 nm. Porins are embedded into the lipid membrane, allowing for the free substrate transport, but not that of the enzyme due to size limitations. The enzyme activity within the liposome is monitored using pyranine, a fluorescent pH indicator. The response of the liposome biosensor to the substrate acetylthiocholine chloride is relatively fast and reproducible, while the system is stable as has been shown by immobilization within sol-gel.


Assuntos
Acetilcolinesterase/química , Técnicas Biossensoriais/instrumentação , Inibidores da Colinesterase/análise , Inibidores da Colinesterase/química , Lipossomos/química , Nanotecnologia/instrumentação , Espectrometria de Fluorescência/instrumentação , Acetilcolinesterase/análise , Técnicas Biossensoriais/métodos , Materiais Revestidos Biocompatíveis/química , Ativação Enzimática , Enzimas Imobilizadas/análise , Enzimas Imobilizadas/química , Desenho de Equipamento , Análise de Falha de Equipamento , Nanotecnologia/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Espectrometria de Fluorescência/métodos
20.
Biomaterials ; 26(33): 6771-9, 2005 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-15955556

RESUMO

The effect of the sol-gel microenvironment on the activity of acetylcholinesterase, an enzyme of high bio-analytical interest, is presented and is correlated to the overall analytical performance of corresponding biosensors. The sol-gel membranes are initially optimized with respect to the catalyst and the TEOS:H2O ratio (r), for mechanical stability, porosity, and hydrophobicity as well as in terms of enzymatic activity. FT-IR and electrochemical impedance spectroscopy (EIS) are used to probe the configuration and rotational mobility of the enzyme within the sol-gel matrices. Overall, it is observed that the rotational mobility of the protein can be correlated with the sensitivity of the biosensor. Optimum biosensor performance is obtained for base-catalyzed sol-gels with r values close to 2. The biosensor has sensitivity of 2.5 microA/mm, a linear range of response between 1 and 3mm, response time of about 30s, and sensor-to-sensor reproducibility (RSD) of 3%. These analytical characteristics are far superior to previously reported sol-gel biosensors.


Assuntos
Acetilcolinesterase/química , Materiais Biocompatíveis , Técnicas Biossensoriais , Calibragem , Catálise , Membrana Celular/metabolismo , Relação Dose-Resposta a Droga , Eletroquímica , Eletrodos , Microscopia Eletrônica de Varredura , Transição de Fase , Espectrofotometria , Espectroscopia de Infravermelho com Transformada de Fourier , Fatores de Tempo , Água/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...