Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 59
Filtrar
1.
J Thromb Haemost ; 16(3): 565-570, 2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-29322630

RESUMO

Essentials Tests for direct oral anticoagulants (DOACs) are not widely applied. These tests are perceived to be difficult to run and subjected to large between-lab variation. We carried out proficiency testing surveys for DOAC testing in Italy. Interlab variability was small and similar to that of the international normalised ratio. SUMMARY: Background Tests for direct oral anticoagulants (DOACs) are not widely available. The perception that they are difficult to perform and are subject to large between-laboratory variation makes their implementation difficult. Aims We carried out proficiency-testing surveys for DOACs within the activity of the external quality-assessment scheme of the Italian Federation of Thrombosis Centers. Design Participants were provided with coded freeze-dried plasmas without or with graded concentrations of the three main DOACs, and asked to measure prothrombin time (PT), activated partial thromboplastin time (APTT), thrombin time and DOAC concentrations with dedicated tests. The results were centralized for statistical analysis. Results and conclusions All participants (n = 235) reported results for PT and APTT, and approximately one-third reported results for DOAC concentration. PT and APTT showed variable responsiveness to DOACs: PT was more responsive to rivaroxaban than to dabigatran or apixaban. APTT was more responsive to dabigatran than to rivaroxaban or apixaban. The thrombin time ratio (test/normal) was close to unity for plasmas without dabigatran, and was high (i.e. 7.6-fold or 15.4-fold longer than the plasma free from the drug) for plasmas containing dabigatran at low (i.e. 42 ng mL-1 ) or high (i.e. 182 ng mL-1 ) concentration. Dedicated tests were responsive to the respective drugs, and their interlaboratory variability was relatively small (overall coefficients of variation of 8.7%, 8.4% or 10.3% for dabigatran, rivaroxaban and apixaban, respectively) and was comparable to that observed within the same survey for the International Normalized Ratio (i.e. 11.4%). In conclusion, tests for DOAC measurement performed reasonably well in a national quality-control scheme. Regulatory authorities should urgently issue recommendations on their use, and clinical laboratories should make them available.


Assuntos
Administração Oral , Anticoagulantes/sangue , Serviços de Laboratório Clínico/normas , Antitrombinas/uso terapêutico , Testes de Coagulação Sanguínea/métodos , Testes de Coagulação Sanguínea/normas , Calibragem , Dabigatrana/sangue , Humanos , Coeficiente Internacional Normatizado , Itália , Tempo de Tromboplastina Parcial , Tempo de Protrombina , Pirazóis/sangue , Piridonas/sangue , Controle de Qualidade , Reprodutibilidade dos Testes , Rivaroxabana/sangue , Inquéritos e Questionários , Tempo de Trombina
2.
J Thromb Haemost ; 16(1): 142-149, 2018 01.
Artigo em Inglês | MEDLINE | ID: mdl-29065247

RESUMO

Essentials Two candidate International Standards for thromboplastin (coded RBT/16 and rTF/16) are proposed. International Sensitivity Index (ISI) of proposed standards was assessed in a 20-centre study. The mean ISI for RBT/16 was 1.21 with a between-centre coefficient of variation of 4.6%. The mean ISI for rTF/16 was 1.11 with a between-centre coefficient of variation of 5.7%. SUMMARY: Background The availability of International Standards for thromboplastin is essential for the calibration of routine reagents and hence the calculation of the International Normalized Ratio (INR). Stocks of the current Fourth International Standards are running low. Candidate replacement materials have been prepared. This article describes the calibration of the proposed Fifth International Standards for thromboplastin, rabbit, plain (coded RBT/16) and for thromboplastin, recombinant, human, plain (coded rTF/16). Methods An international collaborative study was carried out for the assignment of International Sensitivity Indexes (ISIs) to the candidate materials, according to the World Health Organization (WHO) guidelines for thromboplastins and plasma used to control oral anticoagulant therapy with vitamin K antagonists. Results Results were obtained from 20 laboratories. In several cases, deviations from the ISI calibration model were observed, but the average INR deviation attributabled to the model was not greater than 10%. Only valid ISI assessments were used to calculate the mean ISI for each candidate. The mean ISI for RBT/16 was 1.21 (between-laboratory coefficient of variation [CV]: 4.6%), and the mean ISI for rTF/16 was 1.11 (between-laboratory CV: 5.7%). Conclusions The between-laboratory variation of the ISI for candidate material RBT/16 was similar to that of the Fourth International Standard (RBT/05), and the between-laboratory variation of the ISI for candidate material rTF/16 was slightly higher than that of the Fourth International Standard (rTF/09). The candidate materials have been accepted by WHO as the Fifth International Standards for thromboplastin, rabbit plain, and thromboplastin, recombinant, human, plain.


Assuntos
Anticoagulantes/uso terapêutico , Coagulação Sanguínea/efeitos dos fármacos , Monitoramento de Medicamentos/normas , Coeficiente Internacional Normatizado/normas , Tempo de Protrombina/normas , Tromboplastina/normas , Animais , Calibragem , Humanos , Ensaio de Proficiência Laboratorial , Variações Dependentes do Observador , Valor Preditivo dos Testes , Coelhos , Proteínas Recombinantes/normas , Padrões de Referência , Reprodutibilidade dos Testes
3.
J Thromb Haemost ; 15(6): 1180-1190, 2017 06.
Artigo em Inglês | MEDLINE | ID: mdl-28316135

RESUMO

Essentials Between-lab variations of cut-off values in lupus anticoagulant detection are unknown. Cut-off values were calculated in 11 labs each testing plasma from 120 donors with 3 platforms. Major variation was observed even within the same platform. Cut-off values determined in different labs are not interchangeable. SUMMARY: Background Cut-off values for interpretation of lupus anticoagulant (LA) detection are poorly investigated. Aims (i) To assess whether results from healthy donors were normally distributed and (ii) the between-laboratories differences in cut-off values for screening, mixing and LA confirmation when calculated as 99th or 95th centiles, and (iii) to assess their impact on the detection rate for LA. Methods Each of 11 laboratories using one of the three widely used commercial platforms for LA detection was asked to collect plasmas from 120 healthy donors and to perform screening, mixing and LA confirmation with two methods (activated partial thromboplastin time [APTT] and dilute Russell viper venom [dRVV]). A common set of LA-positive or LA-negative freeze-dried plasmas was used to assess the LA detection rate. Results were centralized (Milano) for statistical analysis. Results and conclusions (i) Clotting times or ratios for healthy subjects were not normally distributed in the majority of cases. The take-home message is that cut-off values should be determined preferably by the non-parametric method based on centiles. (ii) There were relatively large inter-laboratory cut-off variations even within the same platform and the variability was marginally attenuated when results were expressed as ratios (test-to-normal pooled plasma). The take-home message is that cut-off values should be determined locally. (iii) There were differences between cut-off values calculated as 99th or 95th centiles that translate into a different LA detection rate (the lower the centile the greater the detection rate). The take-home message is that cut-off values determined as the 95th centile allow a better LA detection rate.


Assuntos
Síndrome Antifosfolipídica/sangue , Testes de Coagulação Sanguínea/métodos , Inibidor de Coagulação do Lúpus/sangue , Tempo de Tromboplastina Parcial , Adolescente , Adulto , Idoso , Feminino , Voluntários Saudáveis , Humanos , Masculino , Pessoa de Meia-Idade , Distribuição Normal , Plasma/química , Tempo de Protrombina/métodos , Valores de Referência , Reprodutibilidade dos Testes , Adulto Jovem
4.
Haemophilia ; 22(4): e286-91, 2016 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-27166132

RESUMO

INTRODUCTION: Patients with haemophilia A (HA) have impaired thrombin generation (TG) capacity and TG assay (TGA) values are linearly related to plasma factor VIII (FVIII) levels. AIM: This study carried out in patients with unmeasurable FVIII (<1 IU dL(-1) ) was aimed at unravelling any difference in TG capacity in patients with or without inhibitors. METHODS: Blood samples were collected from patients in a non-bleeding state, after a 5-day wash-out period from last treatment. RESULTS: TGA was performed in 102 patients with severe HA (15% with high-responding inhibitors; 51% with null F8 mutations, that as expected were more prevalent in inhibitor than in non-inhibitor patients). TG capacity was significantly lower in inhibitor than non-inhibitor patients and in those with null mutations than in those with non-null mutations. When the TG capacity was evaluated only in patients with null mutations with and without inhibitors it was lower in the presence of inhibitors. CONCLUSIONS: This study shows a greater TG impairment in inhibitor patients irrespective of FVIII levels, inhibitor titre and F8 mutation type, suggesting a role for the TGA in unravelling functional interferences of anti-FVIII inhibitors on coagulation system activation.


Assuntos
Hemofilia A/sangue , Trombina/análise , Adulto , Anticorpos Neutralizantes/sangue , Testes de Coagulação Sanguínea , Fator VIII/genética , Genótipo , Hemofilia A/patologia , Humanos , Masculino , Pessoa de Meia-Idade , Mutação , Índice de Gravidade de Doença
5.
Haemophilia ; 22(4): e292-300, 2016 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-27197961

RESUMO

INTRODUCTION: In the presence of high-titre inhibitors, haemostatic bypassing agents are used to control bleeding and perform surgery. In this setting, no specific laboratory test is yet available to guide drug choice, monitor treatment efficacy and predict the risk of bleeding. AIM: The aims of this study, carried out in patients candidate to orthopaedic surgery, were to assess the dose-dependent increase in thrombin generation (TG) after infusion of bypassing agents and to evaluate whether or not a correlation existed between the haemostatic efficacy of bypassing therapies and perioperative TG values. METHODS AND RESULTS: TG was measured in 16 inhibitor patients, 10 of whom underwent 11 major orthopaedic procedures. In the non-bleeding state, TG significantly improved 30 min after whichever dose (P < 0.01), with no dose-response relationship when values obtained after different rFVIIa doses were compared. TG significantly improved 30 min after the preoperative bolus (P < 0.05), while during the postoperative period TG values measured before and after dosing did not differ. Moreover, postoperative TG values were similar or even more impaired (P ≤ 0.05) than those measured before preoperative dosing. No difference was found by comparing procedures with and without bleeding complications and yet no bleeding occurred in spite of persistently low TG values in one-third of procedures. CONCLUSION: This study fails to support a definite role for the TG assay as a reliable laboratory tool to monitor the haemostatic efficacy of bypassing therapies and as a predictor of the risk of bleeding in inhibitor patients using these agents during orthopaedic surgery.


Assuntos
Anticorpos Neutralizantes/sangue , Fatores de Coagulação Sanguínea/uso terapêutico , Coagulantes/uso terapêutico , Fator VIIa/uso terapêutico , Hemofilia A/tratamento farmacológico , Trombina/análise , Adolescente , Adulto , Hemofilia A/patologia , Hemorragia/prevenção & controle , Humanos , Masculino , Cuidados Pré-Operatórios , Proteínas Recombinantes/uso terapêutico , Índice de Gravidade de Doença , Procedimentos Cirúrgicos Operatórios , Adulto Jovem
11.
Lupus ; 21(7): 715-7, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-22635210

RESUMO

Results for lupus anticoagulant (LA) are expressed as ratio of patient-to-normal clotting times (LA-ratio) according to the equation LA-ratio = (Patient(Clotting time)/Normal(Clotting time)). However, numerical results vary according to the method used for testing, thus making difficult the between-method and between-laboratory comparison of results. The hypothesis that the standardization model currently employed for the international normalized ratio for patients on warfarin is valid also for LA standardization has been taken into consideration. The model calls for the determination of a LA-sensitivity index (LASI) for each commercial method for LA detection against a common standard method. The LASI is then used to convert the LA-ratio into a scale called standardized LA-ratio (SLA-ratio) according to the equation SLA-ratio = (LA-ratio)(LASI). The model proved effective in minimizing the between-method variability of results for LA detection. If implemented it could be a valuable tool to improve the comparability of results obtained in different laboratories, to quantify the LA potency and thus pave the way to the organization of collaborative clinical trials aimed at assessing whether the potency of LA is a risk factor for clinical events.


Assuntos
Testes de Coagulação Sanguínea/normas , Inibidor de Coagulação do Lúpus/sangue , Humanos , Modelos Biológicos
16.
Biologicals ; 38(4): 430-6, 2010 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-20338779

RESUMO

The Prothrombin Time (PT) test is used for monitoring of treatment with Vitamin K-antagonists (VKA). The result of the PT test should be expressed as the International Normalized Ratio (INR). Calculation of INR is based on the availability of International Standards (IS) for thromboplastin and a calibration model. Calibration of a new PT test system is performed with the appropriate IS and fresh plasma samples of healthy (normal) volunteers and patients treated with VKA. The calibration model is based on the assumption of a linear relationship between the log(PT)'s obtained with the new PT system and the reference IS for both normal and patients' samples. Patients' samples for calibration should be selected by rejecting samples beyond the 1.5-4.5 INR range. Outliers should be rejected defined as points with a perpendicular distance greater than three residual standard deviations from the line of relationship. Selection of patients' samples and rejection of outliers result in a reduction of the between-laboratory variation of calibration. In addition to monitoring of VKA, the PT is used for management of patients with chronic liver disease. Likewise, INR(liver) should be based on calibration with an IS using samples from patients with chronic liver disease.


Assuntos
Coeficiente Internacional Normatizado , Tromboplastina/normas , Calibragem , Humanos , Hepatopatias/sangue , Hepatopatias/diagnóstico , Tempo de Protrombina , Padrões de Referência , Sensibilidade e Especificidade
17.
Thromb Res ; 125(6): 523-8, 2010 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-20117825

RESUMO

International Sensitivity Index (ISI) calibration is based on prothrombin time (PT) determinations in fresh plasma samples of healthy (normal) individuals and patients treated with vitamin K-antagonists (VKA). The ISI is calculated from the slope of the orthogonal regression line of the log(PT) results. The ISI calibration model is based on the assumption that the mean logarithms of the PT's of the normals are found on the orthogonal regression line derived using patients' samples. According to World Health Organization (WHO) guidelines, patients' samples with International Normalized Ratio (INR) beyond the 1.5 to 4.5 interval shall be excluded for ISI calibration. According to the WHO guidelines, outlier samples are defined as those at a perpendicular distance from the orthogonal regression line greater than 3 residual standard deviations, and shall be excluded as well. The purpose of the present study was to assess the effect of sample exclusion on ISI calibration, using the data base of three historic multicenter studies performed in 1990, 1995 and 2005, respectively. Various rules for sample exclusion were tried. In comparison to calibration without any exclusion, between-laboratory variation of the ISI was slightly reduced by sample exclusion using the WHO rule. Furthermore, the adequacy of the ISI calibration model was improved. The effect of the WHO sample exclusion rule on the mean value of the ISI of the current International Standards for thromboplastins was not greater than approximately 1%. It is concluded that the WHO rule for sample exclusion is appropriate for reliable ISI calibration.


Assuntos
Estudos Multicêntricos como Assunto/métodos , Tempo de Protrombina/normas , Calibragem/normas , Fibrinolíticos/uso terapêutico , Humanos , Coeficiente Internacional Normatizado , Estudos Multicêntricos como Assunto/normas , Tempo de Protrombina/métodos , Análise de Regressão , Vitamina K/antagonistas & inibidores , Organização Mundial da Saúde
18.
J Thromb Haemost ; 8(4): 737-43, 2010 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-20102490

RESUMO

BACKGROUND: Patients with severe hemophilia may show very varied bleeding tendencies, and the reasons for this heterogeneous clinical expression are unclear. The factor VIII/FIX genotype is the main determinant of the residual factor activity; however, different bleeding phenotypes have also been reported in patients sharing the same mutation. Such global coagulation tests as thrombin generation assays are tools with which to investigate different coagulation profiles among severe hemophiliacs. OBJECTIVES, PATIENTS AND METHODS: This case-control study was aimed at comprehensively evaluating the role of genotype and endogenous thrombin potential (ETP) as predictors of the clinical phenotype in severe hemophiliacs with an extremely mild bleeding tendency (cases, n = 22), in comparison with those showing a typical bleeding tendency (controls, n = 50). RESULTS: Cases were more frequently affected by hemophilia B than by hemophilia A, and showed a lower incidence of severe FVIII/FIX gene defects (referred to as null mutations), higher FVIII and FIX antigen levels and higher ETP values in platelet-rich plasma than controls (P < 0.05). By multivariate logistic regression, only non-null mutations were confirmed as an independent predictor of a mild clinical phenotype. CONCLUSIONS: These results indicate that non-null mutations represent the main determinant of the bleeding tendency, and that ETP measurement in platelet-rich plasma is able to identify severe hemophiliacs with a mild clinical phenotype.


Assuntos
Coagulação Sanguínea , Hemofilia A/diagnóstico , Hemofilia B/diagnóstico , Hemorragia/etiologia , Adulto , Coagulação Sanguínea/genética , Testes de Coagulação Sanguínea , Estudos de Casos e Controles , Fator IX/genética , Fator IX/metabolismo , Fator VIII/genética , Fator VIII/metabolismo , Frequência do Gene , Predisposição Genética para Doença , Hemofilia A/sangue , Hemofilia A/complicações , Hemofilia A/genética , Hemofilia B/sangue , Hemofilia B/complicações , Hemofilia B/genética , Hemorragia/sangue , Hemorragia/genética , Humanos , Itália , Modelos Logísticos , Pessoa de Meia-Idade , Razão de Chances , Fenótipo , Valor Preditivo dos Testes , Medição de Risco , Fatores de Risco , Índice de Gravidade de Doença , Trombina/metabolismo
20.
J Thromb Haemost ; 6(9): 1534-41, 2008 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-18662260

RESUMO

BACKGROUND: Over the last 4 years ADAMTS-13 measurement underwent dramatic progress with newer and simpler methods. AIMS: Blind evaluation of newer methods for their performance characteristics. DESIGN: The literature was searched for new methods and the authors invited to join the evaluation. Participants were provided with a set of 60 coded frozen plasmas that were prepared centrally by dilutions of one ADAMTS-13-deficient plasma (arbitrarily set at 0%) into one normal-pooled plasma (set at 100%). There were six different test plasmas ranging from 100% to 0%. Each plasma was tested 'blind' 10 times by each method and results expressed as percentage vs. the local and the common standard provided by the organizer. RESULTS: There were eight functional and three antigen assays. Linearity of observed-vs.-expected ADAMTS-13 levels assessed as r2 ranged from 0.931 to 0.998. Between-run reproducibility expressed as the (mean) CV for repeated measurements was below 10% for three methods, 10-15% for five methods and up to 20% for the remaining three. F-values (analysis of variance) calculated to assess the capacity to distinguish between ADAMTS-13 levels (the higher the F-value, the better the capacity) ranged from 3965 to 137. Between-method variability (CV) amounted to 24.8% when calculated vs. the local and to 20.5% when calculated vs. the common standard. Comparative analysis showed that functional assays employing modified von Willebrand factor peptides as substrate for ADAMTS-13 offer the best performance characteristics. CONCLUSIONS: New assays for ADAMTS-13 have the potential to make the investigation/management of patients with thrombotic microangiopathies much easier than in the past.


Assuntos
Proteínas ADAM/sangue , Comportamento Cooperativo , Fator de von Willebrand/metabolismo , Proteína ADAMTS13 , Humanos , Hidrólise , Padrões de Referência , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...