Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 101
Filtrar
1.
J Prosthodont ; 2024 Jul 22.
Artigo em Inglês | MEDLINE | ID: mdl-39034840

RESUMO

3D-printed shell complete dentures generated from a scan of the patient's existing prostheses can simplify and expedite the surgical planning and interim restoration design for complete arch rehabilitations. Three patients were rehabilitated with endosteal implants, and interim restorations were generated from the contours of the 3D-printed shell complete dentures used as diagnostic aids. This case series report presents the recommended protocol and its clinical progression, in addition to clinical and radiographic images of the treatment outcomes.

2.
Res Sq ; 2024 Jun 18.
Artigo em Inglês | MEDLINE | ID: mdl-38947036

RESUMO

The Cystine-xCT transporter-Glutathione (GSH)-GPX4 axis is the canonical pathway to protect against ferroptosis. While not required for ferroptosis-inducing compounds (FINs) targeting GPX4, FINs targeting the xCT transporter require mitochondria and its lipid peroxidation to trigger ferroptosis. However, the mechanism underlying the difference between these FINs is still unknown. Given that cysteine is also required for coenzyme A (CoA) biosynthesis, here we show that CoA supplementation specifically prevents ferroptosis induced by xCT inhibitors but not GPX4 inhibitors. We find that, auranofin, a thioredoxin reductase inhibitor, abolishes the protective effect of CoA. We also find that CoA availability determines the enzymatic activity of thioredoxin reductase, but not thioredoxin. Importantly, the mitochondrial thioredoxin system, but not the cytosolic thioredoxin system, determines CoA-mediated ferroptosis inhibition. Our data show that the CoA regulates the in vitro enzymatic activity of mitochondrial thioredoxin reductase (TXNRD2) by covalently modifying the thiol group of cysteine (CoAlation) on Cys-483. Replacing Cys-483 with alanine on TXNRD2 abolishes its in vitro enzymatic activity and ability to protect cells from ferroptosis. Targeting xCT to limit cysteine import and, therefore, CoA biosynthesis reduced CoAlation on TXNRD2, an effect that was rescued by CoA supplementation. Furthermore, the fibroblasts from patients with disrupted CoA metabolism demonstrate increased mitochondrial lipid peroxidation. In organotypic brain slice cultures, inhibition of CoA biosynthesis leads to an oxidized thioredoxin system, mitochondrial lipid peroxidation, and loss in cell viability, which were all rescued by ferrostatin-1. These findings identify CoA-mediated post-translation modification to regulate the thioredoxin system as an alternative ferroptosis protection pathway with potential clinical relevance for patients with disrupted CoA metabolism.

3.
Heliyon ; 10(11): e32378, 2024 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-38933987

RESUMO

Background: Residual mitral regurgitation (MR) is frequent after transcatheter edge-to-edge repair (TEER). There is controversy regarding the clinical impact of residual MR and its quantitative assessment by transthoracic echocardiography (TTE), which is often challenging with multiple eccentric jets and artifact from the clip. The utility of the velocity time integral (VTI) ratio between the mitral valve (MV) and left ventricular outflow tract (LVOT), (VTIMV/LVOT), a simple Doppler measurement that increases with MR, has not been assessed post TEER. Methods: Baseline characteristics, clinical outcomes, and TTE data from patients who underwent TEER between 2014 and 2021 across three academic centers were retrospectively analyzed. Post-procedure TTEs were evaluated for VTIMV/LVOT in the first three months after TEER. One-year outcomes including all-cause and cardiac mortality, major adverse cardiac events, and MV reintervention were compared between patients with high VTIMV/LVOT (≥2.5) and low (<2.5). Results: In total, 372 patients were included (mean age 78.7 ± 8.8 years, 68 % male, mean pre-TEER ejection fraction of 50.5 ± 14.7 %). Follow up TTEs were performed at a median of 37.5 (IQR 30-48) days post-procedure. Patients with high VTIMV/LVOT had significantly higher all-cause mortality (HR 2.10, p = 0.003), cardiac mortality (HR 3.03, p = 0.004) and heart failure admissions (HR 2.28, p < 0.001) at one-year post-procedure. There was no association between raised VTIMV/LVOT and subsequent MV reintervention. Conclusion: High VTIMV/LVOT has clinically significant prognostic value at one year post TEER. This tool could be used to select patients for consideration of repeat intervention.

4.
Eur J Prev Cardiol ; 2024 Jun 24.
Artigo em Inglês | MEDLINE | ID: mdl-38916491

RESUMO

AIM: Lipoprotein(a) [Lp(a)] has demonstrated its association with atherosclerosis and myocardial infarction. However, its role in the development of in-stent restenosis (ISR) after percutaneous coronary intervention (PCI) is not clearly established. The aim of this study is to investigate the association between Lp(a) and ISR. METHODS: A retrospective study of adult patients who underwent successful PCI between January 2006 and December 2017 at the three Mayo Clinic sites and had a preprocedural Lp(a) measurement was conducted. Patients were divided into two groups according to the serum Lp(a) concentration (high Lp(a) ≥50 mg/dl and low Lp(a) <50 mg/dl). Univariable and multivariable analyses were performed to compare risk of ISR between patients with high Lp(a) versus those with low Lp(a). RESULTS: A total of 1209 patients were included, with mean age 65.9 ±11.7 years and 71.8% were male. Median follow-up after baseline PCI was 8.8 (IQR 7.4) years. Restenosis was observed in 162 (13.4%) patients. Median serum levels of Lp(a) were significantly higher in patients affected by ISR versus non-affected cases: 27 (IQR 73.8) vs. 20 (IQR 57.5) mg/dL, p=0.008. The rate of ISR was significantly higher among patients with high Lp(a) versus patients with low Lp(a) values (17.0% vs 11.6%, p=0.010). High Lp(a) values were independently associated with ISR events (HR 1.67, 95%CI 1.18 to 2.37, p=0.004), and this association was more prominent after the first year following the PCI. CONCLUSION: Lipoprotein(a) is an independent predictor for long-term in-stent restenosis and should be considered in the evaluation of patients undergoing PCI.


The role of Lp(a) in the development of in-stent restenosis is not clearly established. In this study including 1209 patients who underwent successful percutaneous coronary intervention and had a preprocedural Lp(a) measurement between 2006 and 2017, the rates of restenosis were significantly higher among patients with high Lp(a) versus patients with low Lp(a) values and high Lp(a) concentrations were independently associated with restenosis events. Lp(a) should be considered as a risk factor for long term in-stent restenosis in the evaluation of patients undergoing percutaneous coronary intervention and assessed as a potential therapeutic target for reducing residual cardiovascular risk in this population.

5.
J Prosthodont ; 2024 Jun 23.
Artigo em Inglês | MEDLINE | ID: mdl-38923252

RESUMO

PURPOSE: To explore the impact of zirconia types, coloring methods, and surface finishing on the color stability of monolithic multilayered polychromatic zirconia after artificial aging, including thermocycling and simulated toothbrushing. MATERIALS AND METHODS: Eighty square-shaped zirconia samples were divided into 2 types (M3Y-TZP and M6Y-PSZ), further categorized based on coloring methods (precolored and extrinsically colored) and surface finishing techniques (mechanical polishing or glazing). The color stability was assessed using the CIEDE2000 formula. Artificial aging was simulated via thermocycling and toothbrushing. All samples were analyzed with a spectrophotometer to determine the post-aging color changes (ΔE00). The ΔE00 were interpreted and classified using the 50:50% perceptibility threshold (PT) and the 50:50% acceptability threshold (AT). Comparisons between groups for ΔE00 differences were performed using three-way ANOVA, with pairwise comparisons facilitated by Fisher's protected least significant difference test, α = 0.05. RESULTS: The study results indicated significant impacts of zirconia type, coloring method, and surface finishing on color stability. The M6Y groups experienced significantly greater color changes (6.61 ± 1.63) compared to the M3Y groups (3.40 ± 2.24), p < 0.0001. For both types of zirconia, extrinsically colored samples exhibited significantly higher ΔE00 when mechanically polished (p = 0.004). However, surface finishing had no significant effect on ΔE00 in precolored samples of either zirconia material (p = 1.000). The evaluation and categorization of ΔE00 variations indicated that nearly all color changes in the M6Y groups, regardless of being precolored, extrinsically colored, polished, or glazed, were deemed extremely unacceptable (Grade 1). In contrast, the M3Y groups showed more acceptable results, with the majority of color changes classified as moderately unacceptable (Grade 3). CONCLUSIONS: The color stability of multilayered polychromatic zirconia is influenced by the type of material, extrinsic coloring, and the chosen surface treatment post-artificial aging. The translucent 6Y-PSZ exhibited lower color stability, especially with only mechanical polishing. For the fabrication of M3Y-TZP and 6Y-PSZ monolithic multilayered polychromatic zirconia restorations, extrinsic coloring should be paired with glazing to maintain color stability. Conversely, in the absence of extrinsic coloring, both glazing and mechanical polishing are effective in preserving color stability.

6.
J Prosthodont ; 2024 May 14.
Artigo em Inglês | MEDLINE | ID: mdl-38742795

RESUMO

PURPOSE: To examine the color stability of 3D-printed and milled, interim, and definitive, restorative materials after immersion in artificial saliva and wine for 1, 3, and 6 months. MATERIAL AND METHODS: The study used a 2 × 5 factorial design with 10 subgroups, including 2 immersion liquids (artificial saliva and wine) and 5 manufacturing technology and restorative material combinations (n = 10). Color measurements were taken using a contact-type digital spectrophotometer (CM-2600d Spectrophotometer; Konica Minolta Healthcare Americas Inc) before immersion and at 1 month (T1), 3 months (T3), and 6 months (T6) after immersion. The CIE2000 system was used to calculate quantitative measurements of color differences in ΔE00, and comparisons were made to the acceptability threshold (AT) and perceptibility threshold (PT). Repeated measures of ANOVA (α = 0.05) were used to compare differences in color changes between manufacturing technology/restorative material-immersion liquid combinations at T1, T3, and T6. RESULTS: To compare the effect of immersion liquid and time on the manufacturing technology/restorative material groups, the ΔE00 values were compared to the PT of 0.8 and the AT of 1.8. Wine caused significant color changes in ΔE00 values beyond the PT and AT values in all groups at all time intervals, except for the AT value of milled definitive crowns (hybrid nano-ceramic material). Wine immersion caused significant ΔE00 for all manufacturing technology/restorative material groups at all time intervals (1 month, 3 months, and 6 months) when compared to artificial saliva immersion (all p < 0.001). CONCLUSION: Upon exposure to artificial saliva, 80%-100% of samples from all groups remained within the acceptable and perceptible color change thresholds. The wine had significant chromogenic effects on all tested restorative materials, however, the milled definitive crowns (hybrid nano-ceramic material) showed the greatest color stability. For patients with heavy wine consumption, 3D-printed definitive crowns (hybrid ceramic-filled material) may show discoloration exceeding acceptable and perceptible color change limits.

7.
Eur Heart J Digit Health ; 5(3): 295-302, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38774378

RESUMO

Aims: Cardiac amyloidosis (CA) is common in patients with severe aortic stenosis (AS) undergoing transcatheter aortic valve replacement (TAVR). Cardiac amyloidosis has poor outcomes, and its assessment in all TAVR patients is costly and challenging. Electrocardiogram (ECG) artificial intelligence (AI) algorithms that screen for CA may be useful to identify at-risk patients. Methods and results: In this retrospective analysis of our institutional National Cardiovascular Disease Registry (NCDR)-TAVR database, patients undergoing TAVR between January 2012 and December 2018 were included. Pre-TAVR CA probability was analysed by an ECG AI predictive model, with >50% risk defined as high probability for CA. Univariable and propensity score covariate adjustment analyses using Cox regression were performed to compare clinical outcomes between patients with high CA probability vs. those with low probability at 1-year follow-up after TAVR. Of 1426 patients who underwent TAVR (mean age 81.0 ± 8.5 years, 57.6% male), 349 (24.4%) had high CA probability on pre-procedure ECG. Only 17 (1.2%) had a clinical diagnosis of CA. After multivariable adjustment, high probability of CA by ECG AI algorithm was significantly associated with increased all-cause mortality [hazard ratio (HR) 1.40, 95% confidence interval (CI) 1.01-1.96, P = 0.046] and higher rates of major adverse cardiovascular events (transient ischaemic attack (TIA)/stroke, myocardial infarction, and heart failure hospitalizations] (HR 1.36, 95% CI 1.01-1.82, P = 0.041), driven primarily by heart failure hospitalizations (HR 1.58, 95% CI 1.13-2.20, P = 0.008) at 1-year follow-up. There were no significant differences in TIA/stroke or myocardial infarction. Conclusion: Artificial intelligence applied to pre-TAVR ECGs identifies a subgroup at higher risk of clinical events. These targeted patients may benefit from further diagnostic evaluation for CA.

9.
J Prosthodont ; 2024 Apr 10.
Artigo em Inglês | MEDLINE | ID: mdl-38600720

RESUMO

Traditionally, artificial teeth arrangements or the definitive complete dentures are used to establish important prosthodontic parameters such as the occlusal plane orientation, vertical dimension, and the incisal edge position. The relationship of these elements with the underlying bony structures is commonly evaluated using advanced planning protocols such as the dual scan technique. This technique article presents an uncomplicated alternative approach to establish these parameters intraorally using a 3D-printed shell complete denture generated from a 3D scan of the patient's existing complete denture.

10.
Artigo em Inglês | MEDLINE | ID: mdl-38669204

RESUMO

AIMS: Doppler mean gradient (MG) can underestimate aortic stenosis (AS) severity in patients with atrial fibrillation (AF) compared to patients in sinus rhythm (SR), potentially delaying intervention in AF. This study compared outcomes in patients with AF and SR following transcatheter aortic valve replacement (TAVR) and investigated delay in TAVR based on computed tomography aortic valve calcium score (AVCS). METHODS AND RESULTS: Patients who underwent TAVR from 2013 to 2017 for native valve severe AS were identified from an institutional database. Baseline characteristics and overall survival were compared between those in SR and AF. There were 820 patients (mean age 81 years; 41.6% female) included. AF was present in 356 patients. Patients in AF were older (82.2 vs. 80.5, p = 0.003), had lower MG compared to SR patients (42.0 vs. 44.9, p = 0.002) with similar indexed aortic valve area (0.4 vs. 0.4, p = 0.17). Median AVCS was higher in AF (males: AF 2850.0 vs. SR 2561.0, p = 0.044; females: AF 1942.0 vs. SR 1610.5, p = 0.025). Projected AVCS assuming same age of diagnosis was similar between AF and SR. Median survival post-TAVR was worse in AF compared to SR (3.2 vs 5.4 years, log rank p < 0.001). AF, lower MG, higher RVSP, dialysis, diabetes, and significant TR were associated with higher mortality (p < 0.05 for all). CONCLUSION: Older age and higher AVCS in patients with AF compared to SR suggests that AS was both underestimated and more advanced at TAVR referral.

11.
bioRxiv ; 2024 Feb 27.
Artigo em Inglês | MEDLINE | ID: mdl-38464226

RESUMO

Ninjurin-1 (NINJ1), initially identified as a stress-induced protein in neurons, recently emerged as a key mediator of plasma membrane rupture during apoptosis, necrosis, and pyroptosis. However, its involvement in ferroptosis remains unknown. Here, we demonstrate that NINJ1 also plays a crucial role in ferroptosis, but through a distinct mechanism. NINJ1 knockdown significantly protected cancer cells against ferroptosis induced by xCT inhibitors but no other classes of ferroptosis-inducing compounds (FINs). Glycine, known to inhibit canonical NINJ1-mediated membrane rupture in other cell deaths, had no impact on ferroptosis. A compound screen revealed that NINJ1-mediated ferroptosis protection can be abolished by pantothenate kinase inhibitor (PANKi), buthionine sulfoximine (BSO), and diethylmaleate (DEM). These results suggest that this ferroptosis protection is mediated via Coenzyme A (CoA) and glutathione (GSH), both of which were found to be elevated upon NINJ1 knockdown. Furthermore, we discovered that NINJ1 interacts with the xCT antiporter, which is responsible for cystine uptake for the biosynthesis of CoA and GSH. The removal of NINJ1 increased xCT levels and stability, enhanced cystine uptake, and contributed to elevated CoA and GSH levels, collectively contributing to ferroptosis protection. These findings reveal that NINJ1 regulates ferroptosis via a non-canonical mechanism, distinct from other regulated cell deaths.

12.
J Cardiovasc Dev Dis ; 11(3)2024 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-38535118

RESUMO

Cardiac allograft vasculopathy (CAV) is a distinct form of coronary artery disease that represents a major cause of death beyond the first year after heart transplantation. The pathophysiology of CAV is still not completely elucidated; it involves progressive circumferential wall thickening of both the epicardial and intramyocardial coronary arteries. Coronary angiography is still considered the gold-standard test for the diagnosis of CAV, and intravascular ultrasound (IVUS) can detect early intimal thickening with improved sensitivity. However, these tests are invasive and are unable to visualize and evaluate coronary microcirculation. Increasing evidence for non-invasive surveillance techniques assessing both epicardial and microvascular components of CAV may help improve early detection. These include computed tomography coronary angiography (CTCA), single-photon emission computed tomography (SPECT), positron emission tomography (PET), and vasodilator stress myocardial contrast echocardiography perfusion imaging. This review summarizes the current state of diagnostic modalities and their utility and prognostic value for CAV and also evaluates emerging tools that may improve the early detection of this complex disease.

13.
Biomedicines ; 12(3)2024 Mar 19.
Artigo em Inglês | MEDLINE | ID: mdl-38540296

RESUMO

Hypertrophic cardiomyopathy (HCM) is the most common inherited cardiomyopathy. It follows an autosomal dominant inheritance pattern in most cases, with incomplete penetrance and heterogeneity. It is familial in 60% of cases and most of these are caused by pathogenic variants in the core sarcomeric genes (MYH7, MYBPC3, TNNT2, TNNI3, MYL2, MYL3, TPM1, ACTC1). Genetic testing using targeted disease-specific panels that utilize next-generation sequencing (NGS) and include sarcomeric genes with the strongest evidence of association and syndrome-associated genes is highly recommended for every HCM patient to confirm the diagnosis, identify the molecular etiology, and guide screening and management. The yield of genetic testing for a disease-causing variant is 30% in sporadic cases and up to 60% in familial cases and in younger patients with typical asymmetrical septal hypertrophy. Genetic testing remains challenging in the interpretation of results and classification of variants. Therefore, in 2015 the American College of Medical Genetics and Genomics (ACMG) established guidelines to classify and interpret the variants with an emphasis on the necessity of periodic reassessment of variant classification as genetic knowledge rapidly expands. The current guidelines recommend focused cascade genetic testing regardless of age in phenotype-negative first-degree relatives if a variant with decisive evidence of pathogenicity has been identified in the proband. Genetic test results in family members guide longitudinal clinical surveillance. At present, there is emerging evidence for genetic test application in risk stratification and management but its implementation into clinical practice needs further study. Promising fields such as gene therapy and implementation of artificial intelligence in the diagnosis of HCM are emerging and paving the way for more effective screening and management, but many challenges and obstacles need to be overcome before establishing the practical implications of these new methods.

14.
Headache ; 64(4): 400-409, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38525734

RESUMO

OBJECTIVE: To develop a natural language processing (NLP) algorithm that can accurately extract headache frequency from free-text clinical notes. BACKGROUND: Headache frequency, defined as the number of days with any headache in a month (or 4 weeks), remains a key parameter in the evaluation of treatment response to migraine preventive medications. However, due to the variations and inconsistencies in documentation by clinicians, significant challenges exist to accurately extract headache frequency from the electronic health record (EHR) by traditional NLP algorithms. METHODS: This was a retrospective cross-sectional study with patients identified from two tertiary headache referral centers, Mayo Clinic Arizona and Mayo Clinic Rochester. All neurology consultation notes written by 15 specialized clinicians (11 headache specialists and 4 nurse practitioners) between 2012 and 2022 were extracted and 1915 notes were used for model fine-tuning (90%) and testing (10%). We employed four different NLP frameworks: (1) ClinicalBERT (Bidirectional Encoder Representations from Transformers) regression model, (2) Generative Pre-Trained Transformer-2 (GPT-2) Question Answering (QA) model zero-shot, (3) GPT-2 QA model few-shot training fine-tuned on clinical notes, and (4) GPT-2 generative model few-shot training fine-tuned on clinical notes to generate the answer by considering the context of included text. RESULTS: The mean (standard deviation) headache frequency of our training and testing datasets were 13.4 (10.9) and 14.4 (11.2), respectively. The GPT-2 generative model was the best-performing model with an accuracy of 0.92 (0.91, 0.93, 95% confidence interval [CI]) and R2 score of 0.89 (0.87, 0.90, 95% CI), and all GPT-2-based models outperformed the ClinicalBERT model in terms of exact matching accuracy. Although the ClinicalBERT regression model had the lowest accuracy of 0.27 (0.26, 0.28), it demonstrated a high R2 score of 0.88 (0.85, 0.89), suggesting the ClinicalBERT model can reasonably predict the headache frequency within a range of ≤ ± 3 days, and the R2 score was higher than the GPT-2 QA zero-shot model or GPT-2 QA model few-shot training fine-tuned model. CONCLUSION: We developed a robust information extraction model based on a state-of-the-art large language model, a GPT-2 generative model that can extract headache frequency from EHR free-text clinical notes with high accuracy and R2 score. It overcame several challenges related to different ways clinicians document headache frequency that were not easily achieved by traditional NLP models. We also showed that GPT-2-based frameworks outperformed ClinicalBERT in terms of accuracy in extracting headache frequency from clinical notes. To facilitate research in the field, we released the GPT-2 generative model and inference code with open-source license of community use in GitHub. Additional fine-tuning of the algorithm might be required when applied to different health-care systems for various clinical use cases.


Assuntos
Registros Eletrônicos de Saúde , Processamento de Linguagem Natural , Humanos , Estudos Retrospectivos , Estudos Transversais , Masculino , Feminino , Cefaleia , Adulto , Pessoa de Meia-Idade , Algoritmos
15.
Mayo Clin Proc ; 99(6): 940-952, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38530689

RESUMO

OBJECTIVE: To investigate whether hypotensive patients diagnosed with heart failure and reduced ejection fraction (HFrEF) might benefit from angiotensin receptor-neprilysin inhibitors (ARNis) in real-world practice because patients with baseline systolic blood pressure (SBP) of less than 100 mm Hg have been excluded from landmark trials. PATIENTS AND METHODS: In this multicenter study conducted between January 1, 2013, and December 31, 2021, a total of 7562 symptomatic patients with HFrEF were enrolled and grouped by SBP (hypotension was defined as an SBP of less than 100 mm Hg) and ARNi use as follows: group 1, hypotensive/non-ARNi users (n=484); group 2, hypotensive/ARNi users (n=308); group 3, nonhypotensive/non-ARNi users (n=4560); and group 4, nonhypotensive/ARNi users (n=2210). Inverse probability of treatment weighting was used to balance baseline characteristics for survival analysis. RESULTS: Diverse baseline characteristics and lower rates of medication use were found among non-ARNi users compared with ARNi users. Hypotensive/ARNi users had lower ARNi initiation doses than nonhypotensive/ARNi users. We observed significantly lower mortality, composite heart failure hospitalization, and CV death for hypotensive/ARNi and the other 2 nonhypotensive groups (groups 3 and 4) during a median follow-up of 3.43 years (all P<.05), with a similar effect on reverse remodeling for the hypotensive/ARNi group compared with the hypotensive/non-ARNi group. The event-free survival benefits of ARNi vs renin-angiotensin system inhibitors were consistent with the lower boundary of SBP for clinical benefits found until 88 mm Hg (spline curves) after inverse probability of treatment weighting. CONCLUSION: Patients with HFrEF and hypotension may still benefit from ARNi treatment. Patients with hypotensive HFrEF should not be routinely excluded from ARNi use in a real-world setting.


Assuntos
Aminobutiratos , Antagonistas de Receptores de Angiotensina , Compostos de Bifenilo , Combinação de Medicamentos , Insuficiência Cardíaca , Hipotensão , Volume Sistólico , Valsartana , Remodelação Ventricular , Humanos , Valsartana/uso terapêutico , Insuficiência Cardíaca/tratamento farmacológico , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/fisiopatologia , Masculino , Aminobutiratos/uso terapêutico , Compostos de Bifenilo/uso terapêutico , Feminino , Volume Sistólico/efeitos dos fármacos , Idoso , Antagonistas de Receptores de Angiotensina/uso terapêutico , Remodelação Ventricular/efeitos dos fármacos , Hipotensão/tratamento farmacológico , Hipotensão/mortalidade , Pessoa de Meia-Idade , Tetrazóis/uso terapêutico , Neprilisina/antagonistas & inibidores , Resultado do Tratamento
16.
J Imaging ; 10(2)2024 Jan 31.
Artigo em Inglês | MEDLINE | ID: mdl-38392086

RESUMO

Exposure to high altitude results in hypobaric hypoxia, leading to physiological changes in the cardiovascular system that may result in limiting symptoms, including dyspnea, fatigue, and exercise intolerance. However, it is still unclear why some patients are more susceptible to high-altitude symptoms than others. Hypoxic simulation testing (HST) simulates changes in physiology that occur at a specific altitude by asking the patients to breathe a mixture of gases with decreased oxygen content. This study aimed to determine whether the use of transthoracic echocardiography (TTE) during HST can detect the rise in right-sided pressures and the impact of hypoxia on right ventricle (RV) hemodynamics and right to left shunts, thus revealing the underlying causes of high-altitude signs and symptoms. A retrospective study was performed including consecutive patients with unexplained dyspnea at high altitude. HSTs were performed by administrating reduced FiO2 to simulate altitude levels specific to patients' history. Echocardiography images were obtained at baseline and during hypoxia. The study included 27 patients, with a mean age of 65 years, 14 patients (51.9%) were female. RV systolic pressure increased at peak hypoxia, while RV systolic function declined as shown by a significant decrease in the tricuspid annular plane systolic excursion (TAPSE), the maximum velocity achieved by the lateral tricuspid annulus during systole (S' wave), and the RV free wall longitudinal strain. Additionally, right-to-left shunt was present in 19 (70.4%) patients as identified by bubble contrast injections. Among these, the severity of the shunt increased at peak hypoxia in eight cases (42.1%), and the shunt was only evident during hypoxia in seven patients (36.8%). In conclusion, the use of TTE during HST provides valuable information by revealing the presence of symptomatic, sustained shunts and confirming the decline in RV hemodynamics, thus potentially explaining dyspnea at high altitude. Further studies are needed to establish the optimal clinical role of this physiologic method.

17.
J Prosthodont ; 33(6): 574-583, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38305665

RESUMO

PURPOSE: To evaluate the effects of exposure protocol, voxel sizes, and artifact removal algorithms on the trueness of segmentation in various mandible regions using an artificial intelligence (AI)-based system. MATERIALS AND METHODS: Eleven dry human mandibles were scanned using a cone beam computed tomography (CBCT) scanner under differing exposure protocols (standard and ultra-low), voxel sizes (0.15 mm, 0.3 mm, and 0.45 mm), and with or without artifact removal algorithm. The resulting datasets were segmented using an AI-based system, exported as 3D models, and compared to reference files derived from a white-light laboratory scanner. Deviation measurement was performed using a computer-aided design (CAD) program and recorded as root mean square (RMS). The RMS values were used as a representation of the trueness of the AI-segmented 3D models. A 4-way ANOVA was used to assess the impact of voxel size, exposure protocol, artifact removal algorithm, and location on RMS values (α = 0.05). RESULTS: Significant effects were found with voxel size (p < 0.001) and location (p < 0.001), but not with exposure protocol (p = 0.259) or artifact removal algorithm (p = 0.752). Standard exposure groups had significantly lower RMS values than the ultra-low exposure groups in the mandible body with 0.3 mm (p = 0.014) or 0.45 mm (p < 0.001) voxel sizes, the symphysis with a 0.45 mm voxel size (p = 0.011), and the whole mandible with a 0.45 mm voxel size (p = 0.001). Exposure protocol did not affect RMS values at teeth and alveolar bone (p = 0.544), mandible angles (p = 0.380), condyles (p = 0.114), and coronoids (p = 0.806) locations. CONCLUSION: This study informs optimal exposure protocol and voxel size choices in CBCT imaging for true AI-based automatic segmentation with minimal radiation. The artifact removal algorithm did not influence the trueness of AI segmentation. When using an ultra-low exposure protocol to minimize patient radiation exposure in AI segmentations, a voxel size of 0.15 mm is recommended, while a voxel size of 0.45 mm should be avoided.


Assuntos
Algoritmos , Artefatos , Inteligência Artificial , Tomografia Computadorizada de Feixe Cônico , Mandíbula , Humanos , Tomografia Computadorizada de Feixe Cônico/métodos , Mandíbula/diagnóstico por imagem , Imageamento Tridimensional/métodos , Desenho Assistido por Computador
18.
J Oral Implantol ; 50(2): 111-118, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38400736

RESUMO

Although a smaller size field of view (FOV) of cone-beam computerized tomography (CBCT) reduces radiation exposure, its effect on the accuracy of static computer-aided implant surgery (s-CAIS) remains unknown. This study aimed to evaluate the impact of the size of FOV on the accuracy of s-CAIS and to investigate if the arch affects this effect. A total of 32 implant sites on 8 identical scannable models (maxillae and mandibles) were randomly allocated to 2 FOV sizes: test (5 × 5 cm) and control (10 × 10 cm). All models were scanned with an intraoral scanner (IOS). With the registration of the surface scan and CBCT image, a prosthetic-driven implant position was planned. Following the fabrication of surgical templates, a single-blinded surgeon placed all implants with the fully guided s-CAIS protocol. IOS captured the implant positions with the scan body attached. Implant-planning software measured the angular deviation, 3-dimensional (3D) deviation at the crest, and 3D deviation at the apex between preplanned and actual implant positions. Two-way analysis of variance was used to analyze the effect of FOV and arch on the deviations. The size of FOV did not show a significant effect (P > .198) on angular deviation, 3D deviation at the crest, or 3D deviation at the apex. No significant difference was found when comparing the effect of the size of FOV between the maxillary and mandibular implants. In conclusion, the use of small FOV CBCT demonstrated comparable accuracy of s-CAIS to the use of medium FOV CBCT.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Implantação Dentária Endóssea , Cirurgia Assistida por Computador , Cirurgia Assistida por Computador/métodos , Humanos , Implantação Dentária Endóssea/métodos , Mandíbula/diagnóstico por imagem , Mandíbula/cirurgia , Maxila/diagnóstico por imagem , Maxila/cirurgia , Imageamento Tridimensional/métodos , Implantes Dentários
19.
medRxiv ; 2024 Jan 11.
Artigo em Inglês | MEDLINE | ID: mdl-38260571

RESUMO

Background: To create an opportunistic screening strategy by multitask deep learning methods to stratify prediction for coronary artery calcium (CAC) and associated cardiovascular risk with frontal chest x-rays (CXR) and minimal data from electronic health records (EHR). Methods: In this retrospective study, 2,121 patients with available computed tomography (CT) scans and corresponding CXR images were collected internally (Mayo Enterprise) with calculated CAC scores binned into 3 categories (0, 1-99, and 100+) as ground truths for model training. Results from the internal training were tested on multiple external datasets (domestic (EUH) and foreign (VGHTPE)) with significant racial and ethnic differences and classification performance was compared. Findings: Classification performance between 0, 1-99, and 100+ CAC scores performed moderately on both the internal test and external datasets, reaching average f1-score of 0.66 for Mayo, 0.62 for EUH and 0.61 for VGHTPE. For the clinically relevant binary task of 0 vs 400+ CAC classification, the performance of our model on the internal test and external datasets reached an average AUCROC of 0.84. Interpretation: The fusion model trained on CXR performed better (0.84 average AUROC on internal and external dataset) than existing state-of-the-art models on predicting CAC scores only on internal (0.73 AUROC), with robust performance on external datasets. Thus, our proposed model may be used as a robust, first-pass opportunistic screening method for cardiovascular risk from regular chest radiographs. For community use, trained model and the inference code can be downloaded with an academic open-source license from https://github.com/jeong-jasonji/MTL_CAC_classification . Funding: The study was partially supported by National Institute of Health 1R01HL155410-01A1 award.

20.
Heart ; 110(4): 299-305, 2024 Jan 29.
Artigo em Inglês | MEDLINE | ID: mdl-37643771

RESUMO

OBJECTIVES: Lipoprotein(a) (Lp(a)) is associated with an increased incidence of native aortic stenosis, which shares similar pathological mechanisms with bioprosthetic aortic valve (bAV) degeneration. However, evidence regarding the role of Lp(a) concentrations in bAV degeneration is lacking. This study aims to evaluate the association between Lp(a) concentrations and bAV degeneration. METHODS: In this retrospective multicentre study, patients who underwent a bAV replacement between 1 January 2010 and 31 December 2020 and had a Lp(a) measurement were included. Echocardiography follow-up was performed to determine the presence of bioprosthetic valve degeneration, which was defined as an increase >10 mm Hg in mean gradient from baseline with concomitant decrease in effective orifice area and Doppler Velocity Index, or new moderate/severe prosthetic regurgitation. Levels of Lp(a) were compared between patients with and without degeneration and Cox regression analysis was performed to investigate the association between Lp(a) levels and bioprosthetic valve degeneration. RESULTS: In total, 210 cases were included (mean age 74.1±9.4 years, 72.4% males). Median time between baseline and follow-up echocardiography was 4.4 (IQR 3.7) years. Bioprostheses degeneration was observed in 33 (15.7%) patients at follow-up. Median serum levels of Lp(a) were significantly higher in patients affected by degeneration versus non-affected cases: 50.0 (IQR 72.0) vs 15.6 (IQR 48.6) mg/dL, p=0.002. In the regression analysis, high Lp(a) levels (≥30 mg/dL) were associated with degeneration both in a univariable analysis (HR 3.6, 95% CI 1.7 to 7.6, p=0.001) and multivariable analysis adjusted by other risk factors for bioprostheses degeneration (HR 4.4, 95% CI 1.9 to 10.4, p=0.001). CONCLUSIONS: High serum Lp(a) is associated with bAV degeneration. Prospective studies are needed to confirm these findings and to investigate whether lowering Lp(a) levels could slow bioprostheses degradation.


Assuntos
Insuficiência da Valva Aórtica , Estenose da Valva Aórtica , Bioprótese , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Masculino , Humanos , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Feminino , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Valva Aórtica/patologia , Lipoproteína(a) , Estenose da Valva Aórtica/complicações , Ecocardiografia , Insuficiência da Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas/efeitos adversos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Bioprótese/efeitos adversos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...