Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Orthop Surg Res ; 14(1): 454, 2019 Dec 19.
Artigo em Inglês | MEDLINE | ID: mdl-31856862

RESUMO

BACKGROUND: The new second-generation computer system BS-II (Bio-Spine-II) based on the National Instruments' development environment has been designed and constructed for evaluating the stability of various surgical fixative methods of the cadaverous lumbar spine (L1-L5). BS-II holds the measured sample using aluminum fixtures and using four computer-controlled stepper motors; it performs a circular movement (warm up of the specimen), programmatically driven extension (back bend), right and left lateral flexion (lateral bend), left and right axial torsion (rotation), and axial compression (pressure). Four strain gauges are used to measure the stiffness of the sample. The movement of individual components (vertebrae) is contactlessly monitored by two CCD (charge couple device) cameras. The obtained data are in digital form continuously stored in the computer memory for further processing. METHODS: The functionality of the equipment was verified on the cadaverous specimen of the human spine. The stiffness of the sample was measured by strain gauges, and the results were processed using linear regression analysis. Movements of vertebrae were determined by circular discs covered with appropriate patterns. The discs have been linked with the respective vertebrae and were contactlessly monitored by two CCD (charge couple device) cameras and evaluated using digital image processing methods and 2D digital FFT (fast Fourier transformation). Direction and displacement of the individual components were determined by the band of the calculated spectrum. The new device BS-II is controlled by a modifiable computer program designed in the National Instruments' development environment which allows statistical processing of the sample, including its warming up. RESULTS: The computer system BS-II for measurement of biomechanical properties of the spine sample was designed. Functionality of the device was verified by implementation of LUMIR XLIF CAGE implant into a cadaver sample of the human spine. Comparison of the rigidity of the intact and stabilized sample is shown in the graphs of article. The achieved results contributed to certification of the implant into the surgical practice. CONCLUSION: The designed computer BS-II system is designed for biomechanical measurements of the lumbar part of the human spine, especially for verification of surgical fixation methods. The system is based on the knowledge and experience with a manually operated measuring device designed by Palacky University Olomouc. The computer programmatic control allows the user to change the conditions and parameters of the measurement procedure in a planned way, which allows the results to be processed in, among other things, a statistical way. If suitable models are used (3D printing), the BS-II system can be used to verify procedures for surgical stabilization of the spine in the training of future doctors. The obtained data of stiffness and image information are stored in digital form and can be used for next offline sophisticated study of biomechanical properties of specimens (accurate vertebral geometry, statistical processing, 3D printing, etc.). The usefulness of the BS-II system is demonstrated in the case of biomechanical analysis of the implantation of LUMIR XLIF CAGE implant to a human cadaver specimen of the spine.


Assuntos
Processamento de Imagem Assistida por Computador , Vértebras Lombares/diagnóstico por imagem , Vértebras Lombares/fisiologia , Fenômenos Biomecânicos , Cadáver , Humanos , Vértebras Lombares/cirurgia , Próteses e Implantes
2.
Cas Lek Cesk ; 155(7): 357-364, 2016.
Artigo em Tcheco | MEDLINE | ID: mdl-27990830

RESUMO

Secular changes in anthropometric parameters reflect the effect of socio-economic conditions in interaction with other factors on individuals in the course of 100-200 years. The main aim of the research was to determine the average body height and weight for the current adult population of men 19 to 94 years old and women 19 to 86 years old in the Czech Republic, and to compare the average values ​​of body height and weight of the monitored group with the reference values ​​for the adult population observed in our country from 1895 to 2001.Body height and weight were measured with standard anthropometry in 973 men aged 19-94 years and 2,606 women aged 19-86 years. The research was carried out from 2013 to 2015. Statistical tests: t-test, one-way analysis of variance (ANOVA). The average body weight and height of the current adult male is 178.58 cm and 80.86 kg, and of adult female 165.99 cm and 65.67 kg. When compared to men, women show significantly lower average height by 12.59 cm and lower weight by 15.19 kg. The results show that men today are about 10.61 cm higher and weigh 9.01 kilograms more than men in 1895. Todays women are about 9.43 centimeters taller, but weigh 0,58 kg less than women of the same age in 1895.Comparison of results from 1895 to 2015 shows that at present there is likely stagnation or decline in the positive secular trend in body height among men and women. The weight of men is increasing while there is stagnation in the body weight of women.


Assuntos
Estatura , Peso Corporal , Adulto , Distribuição por Idade , Idoso , Idoso de 80 Anos ou mais , Antropometria/métodos , República Tcheca , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Distribuição por Sexo , Adulto Jovem
3.
Artigo em Inglês | MEDLINE | ID: mdl-17426808

RESUMO

AIMS: To compare the blood supply of the Peyer's patches in pigs with the already defined rodent one. MATERIALS AND METHODS: Pig tissue was used. Injections of india ink, microscopic examination of the histological preparations stained by a haematoxylin - eosin and scanning electron microscopy of the corrosive casts were used for the depiction of the vessels. RESULTS: A model of the blood microcirculation of PP and its relation to the blood circulation of the small intestine was created. Only the capillaries in the follicles, but not the ascending arterioles as in rats were found.


Assuntos
Nódulos Linfáticos Agregados/irrigação sanguínea , Animais , Feminino , Masculino , Microcirculação , Sus scrofa
SELEÇÃO DE REFERÊNCIAS