Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Pak Med Assoc ; 65(6): 669-71, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-26060169

RESUMO

Haemosuccus Pancreaticus is defined as upper gastro intestinal (GI) bleeding from the ampula of vater via the pancreatic duct. It is most commonly associated with pancreatic inflammation, erosion of the pancrease by aneurysm or pseudo-aneurysm of the splenic artery. We report a 69 year old man with previous history of acute pancreatitis who was admitted with recurrent haematemesis. Initial upper GI endocopy was normal, while admitted, he collapse with abdominal pain and hypotension. He was resuscitated with blood and intravenous fluid. Repeat upper GI endocopy showed fresh blood in the duodenum, but no active bleeding site was demonstrated. An urgent coeliac axis CT angiogram was done which showed an splenic artery pseudo-aneurysm, which was successfully embolized. Patient is well 9 months after the procedure. This case highlights the importance of considering coeliac axis CT angiogram as part of investigation for obscure GI bleeding.


Assuntos
Ampola Hepatopancreática , Falso Aneurisma/etiologia , Doenças do Ducto Colédoco/etiologia , Hemorragia Gastrointestinal/etiologia , Pancreatite Alcoólica/complicações , Artéria Esplênica/diagnóstico por imagem , Idoso , Falso Aneurisma/diagnóstico por imagem , Angiografia , Doenças do Ducto Colédoco/diagnóstico por imagem , Hemorragia Gastrointestinal/diagnóstico por imagem , Humanos , Masculino , Tomografia Computadorizada por Raios X
2.
J Vasc Interv Radiol ; 15(11): 1219-30, 2004 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-15525740

RESUMO

PURPOSE: To report the results of a multicenter experience with the Viatorr expanded polytetrafluoroethylene-covered stent-graft for transjugular intrahepatic portosystemic shunt (TIPS) creation in which patency and clinical outcome were evaluated. MATERIALS AND METHODS: One hundred consecutive patients with portal hypertension, with a mean age of 52 years (range, 22-86 years), underwent implantation of the Viatorr TIPS stent-graft at one of three hospital centers. The indications for TIPS creation were variceal bleeding (n = 81) and refractory ascites (n = 19). Twenty patients had Child-Pugh class A disease, 46 had class B disease, and 34 had class C disease. Eighty-seven patients underwent de novo TIPS placements, with 13 treated for recurrent TIPS stenosis. Sixty-two patients were available for follow-up portal venography and portosystemic pressure gradient (PSG) measurement commencing 6 months after Viatorr stent-graft placement. RESULTS: The technical success rate was 100%. TIPS creation resulted in an immediate decrease in mean PSG (+/-SD) from 21 mm Hg +/- 6 to 7 mm Hg +/- 3. Acute repeat intervention (within 30 days) was required for portal vein thrombosis (n = 1), continued bleeding (n = 3), and encephalopathy (n = 1). The all-cause 30-day mortality rate was 12%. Two patients developed acute severe refractory encephalopathy, which led to death in one case. New or worsening encephalopathy was identified in 14% of patients. The incidence of recurrent bleeding was 8%. The cumulative survival rate at 1 year was 65%. Sixty-two patients available for venographic follow-up had a mean PSG of 9 mm Hg +/- 5 at a mean interval of 343 days (range, 56-967 days). There were four stent-graft occlusions (6%) and seven hemodynamically significant stenoses (11%), four within the stent-graft and three in the non-stent-implanted hepatic vein. The primary patency rate at 1 year by Kaplan-Meier analysis was 84%. CONCLUSIONS: This retrospective multicenter experience with the Viatorr stent-graft confirms the preliminary findings of other investigators of good technical results and improved patency compared with bare stents. Early mortality and symptomatic recurrence rates are low by historical standards. The theoretical increase in TIPS-related encephalopathy was not demonstrated. Longer-term follow-up will be required to determine whether the additional cost of the Viatorr stent-graft will be offset by reduced surveillance and repeat intervention.


Assuntos
Politetrafluoretileno , Derivação Portossistêmica Transjugular Intra-Hepática/instrumentação , Stents , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Seguimentos , Oclusão de Enxerto Vascular/etiologia , Encefalopatia Hepática/etiologia , Humanos , Hipertensão Portal/cirurgia , Masculino , Pessoa de Meia-Idade , Flebografia/métodos , Politetrafluoretileno/efeitos adversos , Politetrafluoretileno/uso terapêutico , Derivação Portossistêmica Transjugular Intra-Hepática/efeitos adversos , Derivação Portossistêmica Transjugular Intra-Hepática/estatística & dados numéricos , Complicações Pós-Operatórias/etiologia , Retratamento/métodos , Estudos Retrospectivos , Stents/efeitos adversos , Stents/estatística & dados numéricos , Taxa de Sobrevida , Resultado do Tratamento , Reino Unido , Grau de Desobstrução Vascular/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...